36C24624Q0558.docx
DOCX document 25 KB Posted
- Attached to
- J012--Replace Fire Dampers Bldg. 1
- Solicitation number
- 36C24624Q0558
About this file
This document is a Sources Sought Notice for the procurement of fire damper replacement services at the Fayetteville VAMC in North Carolina. The Department of Veterans Affairs, Network Contracting Office 6 is conducting market research to identify qualified sources, including Service-Disabled Veteran-Owned Small Businesses (SDVOSBs) and Veteran-Owned Small Businesses (VOSBs), for this effort under NAICS code 238220 - Plumbing, Heating, and Air Conditioning Contractors.
The notice provides details on the installation requirements, including conformance to VA master specifications, NFPA recommendations, and Underwriters Laboratories standards. Contractors will be required to perform site visits, submit product information, develop installation schedules, and provide a final report detailing the work performed. Responses to this Sources Sought notice are due by April 19, 2024, and the Government will use the information to make appropriate acquisition decisions, which may lead to a subsequent solicitation announcement.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sources Sought Notice Sources Sought Notice
| SUBJECT* |
| Replace Fire Dampers Bldg. 1 |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 28301 |
| SOLICITATION NUMBER* |
| 36C24624Q0558 |
| RESPONSE DATE/TIME/ZONE |
| 03-18-2024 15:00 EASTERN TIME, NEW YORK, USA |
| ARCHIVE |
| 90 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
| SET-ASIDE |
| SDVOSB |
| PRODUCT SERVICE CODE* |
| J012 |
| NAICS CODE* |
| 238220 |
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs Network Contracting Office 6 201 Hay Street, Suite 304 Fayetteville NC 28301
POINT OF CONTACT*
Contract Specialist Wayne Goodmond wayne.goodmond@va.gov
(910) 824-9189
PLACE OF PERFORMANCE
| ADDRESS |
| Fayetteville VAMC, NC |
2300 Ramsey Street
Fayetteville NC
| POSTAL CODE |
| 28301 |
| COUNTRY |
| USA |
ADDITIONAL INFORMATION
AGENCY’S URL
URL DESCRIPTION
AGENCY CONTACT’S EMAIL ADDRESS
EMAIL DESCRIPTION
DESCRIPTION
Description
THIS IS A SOURCES SOUGHT NOTICE ONLY
The purpose of this Sources Sought is to conduct market research to procure The Repair of Fire Dampers. This notice serves to survey the market to ascertain whether-or-not sources are capable of providing the requested supply/services.
This notice also allows potential contractors/vendors to submit a non-binding statement of interest and documentation demonstrating their capability. Please review the DRAFT Statement of Work (SOW) to compare your supply/service to what is requested. Complete the line-items below and submit any documentation supporting your product/service for consideration. Network Contracting Office 06 (NCO 06) is requesting responses from qualified business concerns; the qualifying NAICS code for this effort is 238220 – Plumbing, Heating, and Air Conditioning Contractors. The Small Business Administration (SBA) Size Standard for this request is $39.5M.
This Sources Sought is to gain knowledge of potential qualified sources and their size classification(s) (Service-Disabled Veteran Owned Small Businesses / Veteran Owned Small Businesses (SDOSB/VOSB)) relative to PSC J012. Responses to this notice, will be used by the Government to make appropriate acquisition decisions. After review of the responses to this notice, a solicitation announcement may be published. Responses to this notice are not considered adequate responses to any corresponding solicitation announcement. All interested offerors are requested to respond to this notice. Only res but are required to respond to the official solicitation announcement in order to be awarded the contract.
The fire dampers are required to be installed in accordance with the following requirements
Installation Requirements
· All work shall be performed in full accordance with applicable local and Federal regulations. All equipment and installation shall conform to the VA master specifications, recommendations of the National Fire Protection Association (NFPA), and Underwriters Laboratories, Inc. The contractor shall use good safety practices during demolition and installation.
· Contractor to perform a site visit to confirm damper locations and sizes.
· Contractor to submit cutsheets for products to be used and a detailed schedule identifying location of work with anticipated durations (coordination with patient care and VA COR is required) before starting work.
· Contractor to remove as much dust and debris on damper and within ductwork utilizing HEPA filtered vacuums before demolition begins. Diffusers within the space will need to be covered during removal and installation of new dampers.
· Contractor to install dampers with required perimeter mounting angles, sleeves, breakaway duct connections, corrosion resistant springs, bearings, bushings and hinges per UL and NFPA.
· Contractor to perform verification and demonstrate of resetting and operation of dampers.
· Contractor to provide a final report listing each damper replaced, a check list showing that all post-installation test functions are complete with pictures of “open”, “closed:, and “reopen” demonstrating the operability of the damper, date of installation, the model, and identification number of the damper.
Responses to this sources sought should be returned to wayne,goodmond@va.gov NLT April 19, 2024
| *= Required Field |
| Sources Sought Notice |
Sources Sought Notice
File details come from the government source that posted it. Updated .