Questions and Responses - Awning.pdf
PDF 125 KB Posted
- Solicitation number
- 36C24622B0027
About this file
This document contains questions and responses regarding solicitation number 36C24622B0027 from the Department of Veterans Affairs Veterans Health Administration for construction services for an Ambulatory Care Addition awning project. The responses clarify that sheet S301 of the drawings correctly specifies 13 number 8 vertical reinforcing bars and number 3 ties at 12 inches on center, rather than the information listed in sheet S-101. The document also states that the specification section referencing general commissioning requirements is to be omitted from the solicitation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| OF 1419 Bid Abstract AWNING.pdf | ||
| 36C24622B0027 0002.docx | DOCX document | |
| 36C24622B0027 0001.docx | DOCX document | |
| Site Visit Sign-In Sheet.pdf | ||
| Subcontractor Certification VAAR 852.219-77.pdf | ||
| Bid Item Cost Breakdown WS.xlsx | XLSX spreadsheet | |
| Spec - Final.pdf | ||
| Drawings.pdf | ||
| SOW - Final .pdf | ||
| NC WAGE RATES 2.25.2022.pdf | ||
| 36C24622B0027_1.docx | DOCX document | |
| Map of Hospital ACA Awning.jpg | JPG image |
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Questions & Responses
36C24622B0027 – ACA Awning
1. Sheet S-101 – Canopy Foundation Plan notes the column having 16 #8 verticals and #4 ties @ 12” oc and Sheet S-301 – Elevation 1 & Section 2 notes having 13 #8 verticals and #3 Ties @ 12” oc. Please clarify which is correct.
Sheet S301 is the correct reinforcing.
2. The spec section final document referenced "Section 01 91 00 General Commissioning Requirements”, but there is no actual Section 01 91 00. Can one be provided if it is meant to be part of the bid documents?
Omit the requirement for Commissioning.