This document provides details on a federal contract opportunity to upgrade fire alarm systems. The solicitation number is 36C24621B0019 and is being issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 6. The project title is Upgrade Fire Alarm System with project number 658-19-105. The opportunity type is a solicitation to upgrade fire alarm systems at a Veterans Affairs medical center. No further specifics on requirements, pricing, or response deadlines are included in this document.

View the file

Other files

File Type Posted
36C24621B0019 0004_1.docx DOCX document
S06 36C24621B0019 0004.pdf PDF
36C24621B0019 0003_1.docx DOCX document
S05 RFI Questions 11-9-2021.pdf PDF
S02 36C24621B0019 0002.pdf PDF
36C24621B0019 0002_1.docx DOCX document
36C24621B0019 0001_1.docx DOCX document
36C24621B0019 0001.pdf PDF
FAR Class Deviation 52.223-99 Clause.pdf PDF
S04 Site Visit Upgrade Fire Alarm Sys. 10-12-21.pdf PDF
S02_36C24621B0019.pdf PDF
Upgade Fire Alarm_Specs 658-19-105.pdf PDF
36C24621B0019_1.docx DOCX document
Upgrade Fire Alarm_Drawings 658-19-105.pdf PDF
Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

5238 VALLEYPOINTE PARKWAY

SUITE 2B, BUILDING C

ROANOKE, VA 24019

800-242-4906 TOLL FREE

540-521-1008 MAIN

www.HandP.com

ENGINEERING • SURVEYING • PLANNING • ENVIRONMENTAL • GIS

HURT & PROFFITT

Inspired | Responsive | Trusted

April 15, 2020

Avetech Design Group 123 Bruton Court, Suite 100 Chesapeake, Virginia 23322

Attention: James Collins, PE Ph: 757-389-5518 / Email: coliins@avetechdg.com

Subject: Asbestos Testing Services Summary Sheet Upgrade Fire Alarm System, Project #658-19-105 Salem VA Medical Center in Salem, Virginia H&P Project 20192002

Mr. Collins, Hurt & Proffitt, Inc. (H&P) was requested to conduct sampling of asbestos containing materials (ACM) in the areas that will be impacted by the work for the Fire Alarm System Upgrade Project. For the surveys, H&P was provided with construction drawings showing the locations where work is planned noting the specific work scope in the respective area. Based on our review of the drawings, sampling was performed on targeted suspect ACM in each work. The targeted sampling was limited to surfaces where components will be mounted and excluded those that could be affected by running of lines since their routing will be determined in the field by the installation contractor. Below is a summary of the materials that were identified as asbestos containing by sampling and analysis listed per building. For a detailed listing of all materials sampled, refer to the respective building’s Asbestos Survey Report.

Building 04

Asbestos containing materials were not identified in the areas and materials sampled during this survey.

Building 05

Asbestos containing materials were not identified in the areas and materials sampled during this survey.

Building 09

Asbestos (3% Chrysotile) was identified in the white mastic on ducting collected on the basement level in Room 2. All similar white duct mastic should be presumed to be asbestos containing.

Building 11

Asbestos (3% Chrysotile) was identified in the white mastic on ducting collected in the 2nd floor hall by Room 223. All similar white duct mastic should be presumed to be asbestos containing.

mailto:coliins@avetechdg.com

A trace (<1%) level of asbestos was detected in the caulking in the brick mortar joints located in the 1st floor exterior open porch area. This level is below the regulatory threshold under EPA regulations for defining a material as regulated and “asbestos containing”. However, OSHA has regulations for the removal and disturbance of trace levels of asbestos; therefore, H&P recommends that the owner assume that all similar caulking in the area is asbestos containing at a trace level.

Building 13

Asbestos containing materials were not identified in the areas and materials sampled during this survey.

Building 14

Asbestos containing materials were not identified in the areas and materials sampled during this survey.

Building15

A trace (<1%) level of asbestos was detected in the plaster skim coat on the wall in the 1st floor hallway.

This level is below the regulatory threshold under EPA regulations for defining a material as regulated and “asbestos containing”. However OSHA has regulations for the removal and disturbance of trace levels of asbestos; therefore, H&P recommends that the owner assume that all skim coat in the area is asbestos containing at a trace level.

Building16

Asbestos containing materials were not identified in the areas and materials sampled during this survey.

Building 75

Asbestos (5% Chrysotile) was identified in the white duct mastic collected in the 2nd floor hall by Room

252. All similar white duct mastic should be presumed to be asbestos containing.

Asbestos (3% Chrysotile) was identified in the white duct mastic collected in the basement level in Room

12. All similar white duct mastic should be presumed to be asbestos containing.

A trace (<1%) level of asbestos was detected in the drywall joint compound collected on the 1st floor hallway area by the stairwell. This level is below the regulatory threshold under EPA regulations for defining a material as regulated and “asbestos containing”. OSHA has regulations for the removal and disturbance of trace levels of asbestos; therefore, H&P recommends that the owner assume that all joint compound in the area is asbestos containing at a trace level.

Building76

Asbestos (2% Chrysotile) was identified in the drywall joint compound collected in the basement level in the Locksmith Room. All similar wall joint compounds should be presumed to be asbestos containing.

Building 145

Asbestos containing materials were not identified in the areas and materials sampled during this survey.

Presumed Asbestos Containing Materials

During the conduct of this survey, sampling was limited to those materials which were within the areas designated by the client, which were safely accessible, and were able to be sampled without damaging systems or structures. Additionally, the facility and multiple rooms were occupied and in use at the time or our survey; which limited our ability to access all areas. As such, other materials not represented in the respective building’s survey should be presumed to be positive, unless sampling is conducted and they are shown to be negative for asbestos. Some components that were not accessible and/or could not be sampled include:

Electrical equipment wiring (i.e. control panels) and switches and panel backer boards;

Fire doors where magnetic locks will be installed. If the scope of work will disturb the inner door core, then this material must be presumed to be asbestos containing and should be treated as such;

unless sampling and analysis is performed and confirms the absence of asbestos in the material.

Thermal systems insulation that may be present in wall cavities or above ceilings and; if the scope of work will disturb the material, then it must be presumed to be asbestos containing and should be treated as such, unless sampling and analysis is performed and confirms the absence of asbestos in the material.

If work is performed that will impact suspect materials that have not been sampled, it is recommended that they be sampled by a Virginia licensed Asbestos Inspector prior to disturbance.

Closing

Should you have any questions please contact Greg Whitt at (540) 521-1008 or via email at g.whitt@handp.com or Mary Beth Wriston at 540-588-0941 or via email at m.wriston@handp.com. We appreciate the opportunity to serve as your environmental consultant.

Sincerely, HURT & PROFFITT, INC

Gregory L. Whitt Roy Wriston Environmental/Industrial Hygiene Manager Environmental/Industrial Hygiene Senior Roanoke Office Roanoke Office mailto:g.whitt@handp.com mailto:m.wriston@handp.com

ROANOKE, VA 24019

800-242-4906 TOLL FREE

540-521-1008 MAIN

www.HandP.com

ENGINEERING • SURVEYING • PLANNING • ENVIRONMENTAL • GIS

February 4, 2020

123 Bruton Court Suite 100 Chesapeake, Virginia 23322

Attention: James Collins, PE Ph: 757-389-5518 / Email: coliins@avetechdg.com

Subject: Building 4 Asbestos Testing Services Upgrade Fire Alarm System, Project #658-19-105

Hurt & Proffitt, Inc. (H&P) was requested to conduct sampling for asbestos containing materials (ACM) that will be impacted by the work for the fire Alarm System Upgrade Project. This survey was conducted in Building 4 at the Salem Veterans Affairs Medical Center in Salem, Virginia. The sampling was performed by H&P representatives Mr. Roy Wriston (Virginia Asbestos Inspector License number is 3303 003648) and Ms. Mary Beth Wriston (Virginia Asbestos Inspector License number is 3303 003466) on December 16-17, 2019 and January 10, 2020. This letter and attachments represent H&P’s report for the above-referenced project.

1.0 Asbestos Survey Procedures and Findings

H&P was provided with construction drawings showing the general locations where work is planned noting the specific work scope in the respective areas. Based on our review of the drawings, sampling was performed to target suspect ACM in each work area based on the work task type. The targeted sampling was limited to surfaces where components will be mounted and excluded materials that could be affected by running of lines since their routing will be determined in the field by the installation contractor. Therefore, the approach of the survey was to sample representative suspect ACM in the locations designated on the drawings in order to provide an understanding of:

Materials that are asbestos containing and require abated prior to disturbance;

Identify those that are not asbestos containing via sampling and analysis.

The survey included the collection and submittal of 50 individual samples of suspect asbestos containing materials (ACM) that were analyzed for a total of 75 layers. The sampling was limited to non-invasive means and was performed in accordance with state and federal regulations.

The suspect asbestos samples were submitted for analysis by EPA Method No. 600/R-93/116 and 600/M4-82-020 polarized light microscopy (PLM). All samples were analyzed by SanAir Technologies

Laboratory of Powhatan, Virginia, a NVLAP accredited laboratory licensed to perform asbestos bulk analysis within the State of Virginia. The sampling results are shown in the following table. Copies of the laboratory Asbestos Analysis Bulk Report and Chain of Custody forms are included as an attachment to this report

Table I –Building 4–Asbestos Sample Analysis Results

Sample # Sample Type Lab Description Sample Location Results Condition

1216RW01-4

2x4 white fissured ceiling tile

White Fibrous 2nd Floor hall by elevator None

Detected Fair

1216RW02-4

2x2 off-white fissured ceiling tile

White Fibrous 2nd Floor hall by elevator None

Detected Fair

1216RW03-4

Plaster-wall Tan Non-Fibrous 2nd Floor stair entry in lobby by elevator

None Detected

Fair

Skim coat-wall White Non-

Fibrous None

Detected Fair

1216RW04-4

2x2 Off-white ceiling tile White Fibrous

2nd Floor Hall by Room 202

None Detected

Fair

1216RW05-4

Drywall-wall White Non-

Fibrous 2nd Floor

Women’s Rest Room

None Detected

Fair

Plaster-wall Beige Non-

Fibrous None

Detected Fair

Skim coat-wall White Non-

Fibrous None

Detected Fair

1216RW06-4

2x2 Off-white ceiling tile White-Fibrous

2nd Floor Hall by Room 215

None Detected

Fair

1216RW07-4

Plaster-wall Tan Non-Fibrous

2nd Floor Hall end by Exit door

None Detected

Fair

Skim coat-wall White Non-

Fibrous None

Detected Fair

1216RW08-4

2x4 Fissured ceiling tile White Fibrous

1st Floor Office of Simulator Center

None Detected

Fair

1216RW09-4

Drywall-ceiling

White Non- Fibrous 1st Floor Lab of

Simulator Center

None Detected

Fair

Texture-ceiling White Non-

Fibrous None

Detected Fair

1216RW10-4

Drywall-wall Brown Non-

Fibrous 1st Floor

Women’s Rest Room by

Simulator Center

None Detected

Fair

Joint Compound-wall

White Non- Fibrous

None Detected

Fair

Sample # Sample Type Lab Description Sample Location Results Condition

1216RW11-4

2x4 White fissured ceiling tile

White Fibrous 1st Floor Hall by

Room 106 None

Detected Fair

1216RW12-4

2x2 Off-white ceiling tile White Fibrous

1st Floor Hall by Room 106

None Detected

Fair

1216RW13-4

Plaster-wall

Brown Non- Fibrous

1st Floor At door to Stairwell by room 107

None Detected

Fair

Skim coat-wall White Non-

Fibrous None

Detected Fair

1216RW14-4 Drywall-wall White Non-

Fibrous 1st Floor Room

None

Detected Fair

1216RW15-4

2x4 Fissured ceiling tile White Fibrous

1st Floor Hall by Room 112

None Detected

Fair

1216RW16-4

Drywall-wall

White Non- Fibrous

1st Floor Kitchen

None Detected

Fair

Tile-wall White Non-

Fibrous None

Detected Fair

1216RW17-4

Drywall-wall White Non-

Fibrous

1st Floor Dry Storage

None Detected

Fair

Drywall-wall Brown Non-

Fibrous None

Detected Fair

Tile-wall White Non-

Fibrous None

Detected Fair

1216RW18-4 2x4 Ceiling Tile Grey Non-

Fibrous

1st Floor Ingredient control area

None Detected

Fair

1217RW19-4 Wall coating Tan Non-Fibrous 2nd Floor locker room None

Detected Fair

1217RW20-4 Wall coating Red Non- Fibrous

2nd Floor Storage room

None Detected

Fair

1217RW21-4 Ceiling coating Tan Non-Fibrous 2nd Floor Elevator room None

Detected Fair

1217RW22-4 Wall coating Brown Non-

Fibrous 2nd Floor

Penthouse None

Detected Fair

1217RW23-4

Plaster ceiling

Beige Non- Fibrous

1st Floor Stairwell lobby by room

None Detected

Fair

Skim coat ceiling White Non-

Fibrous None

Detected Fair

1217RW24-4

Plaster-wall Beige Non-

Fibrous Basement Women’s

Restroom/Wall

None Detected

Fair

Skim Coat-wall White Non-

Fibrous None

1217RW25-4 2x2 Ceiling tile White Fibrous Basement Women’s Restroom

None Detected

Fair

1217RW26-4

Plaster-wall White Non-

Fibrous Basement Post office

None Detected

Fair

Skim coat-wall White Non-

Fibrous None

Detected Fair

1217RW27-4

2x4 Fissured Ceiling tile

White Fibrous Basement Hall by Room Women’s

Restroom

None Detected

Fair

1217RW28-4

2x2 Dotted ceiling tile

White Fibrous Basement By

Building 2 crossover

None Detected

Fair

1217RW29-4

2x2 Fissured ceiling tile White Fibrous

Basement Hall by room 13

None Detected

Fair

1217RW30-4

Plaster-wall Tan Non-Fibrous Basement Canteen storage room

None Detected

Fair

Skim coat-wall White Non-

Fibrous None

Detected Fair

1217RW31-4

Drywall-wall Grey Non-fibrous Basement

Cushman cart charging room

None Detected

Fair

Plaster-wall White Non-

Fibrous None

Detected Fair

Skim coat-wall White Non-

Fibrous None

Detected Fair

1217RW32-4 Wall coating White Non-

Fibrous Basement Room

None

Detected Fair

1217RW33-4

Plaster-wall Grey Non-

Fibrous Basement

Kitchen general storage

None Detected

Fair

Skim coat-wall White non-

Fibrous None

Detected Fair

1217RW34-4

Plaster-wall Grey Non-

Fibrous Basement Dry storage

None Detected

Fair

Skim coat-wall Grey Non-

Fibrous

None Detected

Fair

1217RW35-4

2x4 Dotted ceiling tile

White Fibrous Basement Cafeteria

None Detected

Fair

1217RW36-4

Plaster-wall Grey Non-

Fibrous Basement

Women’s locker room

None Detected

Fair

Skim coat-wall White Non-

Fibrous None

Detected Fair

1217RW37-4 Hard ceiling tile White Non-

Fibrous Basement

Kitchen None

1217RW38-4 2x4 Ceiling tile White Fibrous Basement Retail canteen area None

Detected Fair

1217RW39-4 Wall coating Grey Non-

Fibrous Basement

Dietetic storage None

Detected Fair

1217RW40-4

Plaster-wall Red Non- Fibrous Basement Barber

Shop

None Detected

Fair

Skim coat-wall White Non-

Fibrous None

Detected Fair

1217RW41-4

Black coating-wall Various Non-

Fibrous Basement Room

None

Detected Fair

1217RW42-4 Wall Grey Non-

Fibrous Basement Room

None

Detected Fair

110RW01-4 Duct mastic White Non-

Fibrous Attic-AHU-6

None Detected

Fair

110RW02-4

Duct mastic

White Non- Fibrous

Attic-4-AHU-3

None Detected

Fair

Duct Insulation Yellow Fibrous None

110RW03-4 Duct mastic White Non-

Fibrous Attic-AHU-4-5

None Detected

Fair

110RW04-4

Duct mastic

White Non- Fibrous

Attic-AHU-4-5

None Detected

Fair

Duct insulation Yellow Fibrous None

Detected Fair

110RW05-4 Duct mastic White Non-

Fibrous Attic-Farthest

Back AHU None

Detected Fair

110RW06-4

Duct mastic

White Non- Fibrous Penthouse-4-

AHU-2 Front

None Detected

Fair

Duct insulation Yellow Fibrous None

Detected Fair

110RW07-4

Duct mastic

White Non- Fibrous Penthouse-4-

AHU-2 Back

None Detected

Fair

Duct insulation Yellow Fibrous None

Detected Fair

110RW08-4

Duct mastic

White Non- Fibrous Penthouse-4-

AHU-2 Large

None Detected

Fair

Duct insulation Yellow Fibrous None

Detected

None Detected: No Asbestos Detected

2.0 Analysis Results

Based on the results of sample analysis, asbestos containing materials were not identified in the areaas and materials sampled during this survey.

2.1 Presumed Asbestos Containing Materials

During the conduct of this survey, sampling was limited to those materials which were within the areas designated by the client, which were safely accessible, and were able to be sampled without damaging systems or structures. Additionally, the facility and multiple rooms were occupied and in use at the time or our survey; which limited our ability to access all areas. As such, other materials not represented in this survey should be presumed to be positive, unless sampling is conducted and they are shown to be negative for asbestos. Some components that were not accessible and/or could not be sampled include:

core, then this material must be presumed to be asbestos containing and should be treated as such;

unless sampling and analysis is performed and confirms the absence of asbestos in the material.

Thermal systems insulation that may be present in wall cavities or above ceilings and; if the scope of work will disturb the material, then it must be presumed to be asbestos containing and should be

If work is performed that will impact suspect materials that have not been sampled, it is recommended that they be sampled by a Virginia licensed Asbestos Inspector prior to disturbance. We note that during renovation or demolition activities, it is not uncommon to reveal materials that were not accessible during the survey or their presence could not otherwise be known.

3.0 Applicable Regulations

Following are some applicable regulations pertaining to asbestos containing materials.

3.1 EPA/NESHAP Regulations for Asbestos Containing Materials

The U.S. Environmental Protection Agency promulgated the National Emission Standards for Hazardous Air Pollutants (NESHAP) [40 CFR Part 61], which addresses the application, removal, and disposal of asbestos-containing materials (ACM). Under NESHAP the following categories are defined for asbestos-containing materials:

Friable - When dry, can be crumbled, pulverized, or reduced to powder by hand pressure.

Non-friable - When dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure.

Category I Non-friable ACM - Packings, gaskets, resilient floor coverings, and asphalt roofing products containing more than 1% asbestos.

Category II Non-friable ACM – Any material, excluding Category I Non-friable ACM, which contains more than 1% asbestos.

Regulated Asbestos Containing Material (RACM) – One of the following:

1. Friable ACM

2. Category I Non-friable ACM that has become friable.

3. Category I Non-friable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading.

4. Category II Non-friable ACM that has a high probability of becoming, or has become, friable by the forces expected to act on the material in the course of demolition or renovation operations.

Under NESHAP, the following actions are required:

1. Prior to the commencement of demolition or renovation activities, the building owner must inspect the affected facility or part of the facility where the demolition or renovation activities will occur for the presence of asbestos.

2. Remove all RACM from the facility before any activity begins that would break up, dislodge, or similarly disturb the material or preclude access for subsequent removal.

3. RACM need not be removed if:

a) It is Category I non-friable ACM that is not in poor condition.

b) It is on a facility component that is encased in concrete or other similar material and is adequately wet whenever exposed.

c) It was not accessible for testing and was therefore not discovered until after demolition began and because of the demolition the material cannot be safely removed.

d) It is Category II non-friable ACM and the probability is low that the material will become crumbled, pulverized, or reduced to powder during demolition.

Note: Based on our experience, we recommend that all ACM be removed prior to renovation or demolition due to the fact that disturbance can damage them, create potential exposure to workers and occupants and make them friable. This recommendation is made as a best practice to reduce potential exposure and limit liability.

3.2 OSHA

The Occupational Safety and Health Administration (OSHA) regulates employee exposure to asbestos under 29 CFR 1926.1101 and 29 CFR 1926.1001. Work associated with known or suspect asbestos containing materials (ACM), including trace (<1%) levels of asbestos, must be conducted according to these regulations in addition to the noted EPA regulations where applicable.

If the materials that have been identified as asbestos containing will be disturbed or are in poor condition, it is recommended that the asbestos be removed by an appropriately trained and licensed asbestos abatement contractor in accordance with Virginia, EPA and OSHA regulations.

9.0 Limitations

This report summarizes the results of our sample collection and analysis of the suspect ACM materials at the facility based on our understanding of the requested scope of work. The findings prepared by H&P are based upon our observations and the analytical analysis of the samples collected at the time of our field inspection. The services performed were provided in accordance with generally accepted environmental industry standard practices. No warranty, expressed or implied, is made. Our observations, conclusions and recommendations are based upon conditions readily visible at the site at the time of our visit, the results of testing and analysis and information provided to us by others.

Our conclusions and recommendations are based on the guidelines presented by the EPA, Commonwealth of Virginia and OSHA. Any conditions discovered which deviate from the data contained in this report should be presented to us for our evaluation. This report has been prepared for the exclusive use of the client/or their agents. This service was performed in accordance with generally accepted environmental practices. Our conclusions and recommendations are based, in part, upon information provided to us by others; we have not verified the completeness or accuracy of the information provided by others, unless otherwise noted.

During H&P’s non-invasive inspection, accessible areas were visually surveyed for the presence of ACM.

Areas reviewed were limited to those identified by the Client and that could be readily and safely accessed. Our conclusions and recommendations are based on the results of our testing and cannot be used to form a professional opinion of conditions in other areas beyond those from which the samples were collected. It is possible that inaccessible areas, such as behind walls or above ceilings, may not have been surveyed and therefore conditions in these areas are unknown.

During this study, suspect asbestos samples were submitted for analysis at an NVLAP-accredited laboratory via polarized light microscopy. As with any similar survey of this nature, actual conditions exist only at the precise locations from which samples were collected. Certain inferences are based on the results of this sampling and related testing to form a professional opinion of conditions in areas beyond those from which the samples were collected. It is also understood that this is a limited survey so that it is possible that concealed materials may be present that were not accessible to us. No other warranty, expressed or implied, is made.

H&P assumes no responsibility regarding response actions initiated as a result of our findings; nor liability for the duties and responsibilities of the Client or building owner with respect to compliance with applicable regulations. Compliance with regulations are the responsibility of the Client or building owner in accordance with local, state, and/or federal requirements.

g.whitt@handp.com or Mary Beth Wriston at 540-588-0941 or via email at m.wriston@handp.com. We appreciate the opportunity to serve as your environmental consultant.

Gregory L. Whitt Mary Beth Wriston

Roanoke Office Roanoke Office

Appendices:

Appendix I – Asbestos Laboratory Analysis Report and Chain of Custody Forms

APPENDIX I

Asbestos Analysis Bulk Report

Chain of Custody Forms

SanAir ID#: 19064370

Project #: 20192002

Project Name: Building 4

Report Date: 12/31/2019

Analysis Report prepared for Hurt & Proffitt, Inc.

Dear Roy Wriston, We at SanAir would like to thank you for the work you recently submitted. The 24 sample(s) were received on Thursday, December 19, 2019 via FedEx. The final report(s) is enclosed for the following sample(s): 1217RW19-4, 1217RW20-4, 1217RW21-4, 1217RW22-4, 1217RW23-4, 1217RW24-4, 1217RW25-4, 1217RW26-4, 1217RW27-4, 1217RW28-4, 1217RW29-4, 1217RW30-4, 1217RW31-4, 1217RW32-4, 1217RW33-4, 1217RW34-4, 1217RW35-4, 1217RW36-4, 1217RW37-4, 1217RW38-4, 1217RW39-4, 1217RW40-4, 1217RW41-4, 1217RW42-4.

These results only pertain to this job and should not be used in the interpretation of any other job. This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.

Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory

Final Report Includes:

- Cover Letter

- Analysis Pages

- Disclaimers and Additional Information

Sample conditions:

- 24 samples in Good condition.

1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

20192002Project Number:

20192002P.O. Number:

Project Name: Building 4

12/17/2019Collected Date:

12/19/2019 11:00:00 AMReceived Date:

12/31/2019 2:17:59 PM

19064370 SanAir ID Number

FINAL REPORT

Hurt & Proffitt, Inc.Name:

Address: 2524 Langhorne Road

Lynchburg, VA 24501

434-841-3893 (c)Phone:

Analyst: Moore, Brandi | Upshaw, Zoe

Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers

1217RW19-4 / 19064370-001

Wall

Tan Non-Fibrous

Homogeneous

100% Other None Detected

1217RW20-4 / 19064370-002

Wall

Red Non-Fibrous

Homogeneous

100% Other None Detected

1217RW21-4 / 19064370-003

Ceiling

Tan Non-Fibrous

Homogeneous

100% Other None Detected

1217RW22-4 / 19064370-004

Wall

Brown Non-Fibrous

Homogeneous

100% Other None Detected

1217RW23-4 / 19064370-005

Ceiling, Plaster

Beige Non-Fibrous

Homogeneous

100% Other None Detected

1217RW23-4 / 19064370-005

Ceiling, Skim Coat

White Non-Fibrous

Homogeneous

100% Other None Detected

1217RW24-4 / 19064370-006

Wall, Plaster

Beige Non-Fibrous

Homogeneous

100% Other None Detected

1217RW24-4 / 19064370-006

Wall, Skim Coat

White Non-Fibrous

Homogeneous

100% Other None Detected

1217RW25-4 / 19064370-007

Ceiling Tile

White Fibrous

Homogeneous

65% Cellulose 20% Glass

15% Other None Detected

1217RW26-4 / 19064370-008

Wall, Plaster

White Non-Fibrous

Homogeneous

100% Other None Detected

Analyst:

Analysis Date: 12/31/2019 Date: 12/31/2019

Approved Signatory:

20192002Project Number:

20192002P.O. Number:

Project Name: Building 4

12/17/2019Collected Date:

12/19/2019 11:00:00 AMReceived Date:

12/31/2019 2:17:59 PM

19064370 SanAir ID Number

FINAL REPORT

Hurt & Proffitt, Inc.Name:

Address: 2524 Langhorne Road

Lynchburg, VA 24501

Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers

1217RW26-4 / 19064370-008

Wall, Skim Coat

White Non-Fibrous

Homogeneous

100% Other None Detected

1217RW27-4 / 19064370-009

Ceiling Tile

White Fibrous

Homogeneous

65% Cellulose 20% Glass

15% Other None Detected

1217RW28-4 / 19064370-010

Ceiling Tile

White Fibrous

Homogeneous

65% Cellulose 20% Glass

15% Other None Detected

1217RW29-4 / 19064370-011

Ceiling Tile

White Fibrous

Homogeneous

50% Cellulose 40% Glass

10% Other None Detected

1217RW30-4 / 19064370-012

Wall, Plaster

Tan Non-Fibrous

Homogeneous

100% Other None Detected

1217RW30-4 / 19064370-012

Wall, Skim Coat

White Non-Fibrous

Homogeneous

100% Other None Detected

1217RW31-4 / 19064370-013

Wall, Drywall

Grey Non-Fibrous

Homogeneous

100% Other None Detected

1217RW31-4 / 19064370-013

Wall, Plaster

White Non-Fibrous

Homogeneous

100% Other None Detected

1217RW31-4 / 19064370-013

Wall, Skim Coat

White Non-Fibrous

Homogeneous

100% Other None Detected

1217RW32-4 / 19064370-014

Wall

White Non-Fibrous

Homogeneous

100% Other None Detected

Analyst:

Analysis Date: 12/31/2019 Date: 12/31/2019

Approved Signatory:

1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

20192002Project Number:

20192002P.O. Number:

Project Name: Building 4

12/17/2019Collected Date:

12/19/2019 11:00:00 AMReceived Date:

12/31/2019 2:17:59 PM

19064370 SanAir ID Number

FINAL REPORT

Hurt & Proffitt, Inc.Name:

Address: 2524 Langhorne Road

Lynchburg, VA 24501

Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers

1217RW33-4 / 19064370-015

Wall, Plaster

Grey Non-Fibrous

Homogeneous

100% Other None Detected

1217RW33-4 / 19064370-015

Wall, Skim Coat

White Non-Fibrous

Homogeneous

100% Other None Detected

1217RW34-4 / 19064370-016

Wall, Plaster

Grey Non-Fibrous

Homogeneous

100% Other None Detected

1217RW34-4 / 19064370-016

Wall, Skim Coat

Grey Non-Fibrous

Homogeneous

100% Other None Detected

1217RW35-4 / 19064370-017

Ceiling Tile

White Fibrous

Homogeneous

40% Cellulose 40% Glass

20% Other None Detected

1217RW36-4 / 19064370-018

Wall, Plaster

Grey Non-Fibrous

Homogeneous

100% Other None Detected

1217RW36-4 / 19064370-018

Wall, Skim Coat

White Non-Fibrous

Homogeneous

100% Other None Detected

1217RW37-4 / 19064370-019

Ceiling Tile

White Non-Fibrous

Homogeneous

5% Cellulose 95% Other None Detected

1217RW38-4 / 19064370-020

Ceiling Tile

White Fibrous

Homogeneous

40% Cellulose 40% Glass

20% Other None Detected

1217RW39-4 / 19064370-021

Wall

Grey Non-Fibrous

Homogeneous

100% Other None Detected

Analyst:

Analysis Date: 12/31/2019 Date: 12/31/2019

Approved Signatory:

1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

20192002Project Number:

20192002P.O. Number:

Project Name: Building 4

12/17/2019Collected Date:

12/19/2019 11:00:00 AMReceived Date:

12/31/2019 2:17:59 PM

19064370 SanAir ID Number

FINAL REPORT

Hurt & Proffitt, Inc.Name:

Address: 2524 Langhorne Road

Lynchburg, VA 24501

Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers

1217RW40-4 / 19064370-022

Wall, Plaster

Red Non-Fibrous

Heterogeneous

100% Other None Detected

1217RW40-4 / 19064370-022

Wall, Skim Coat

White Non-Fibrous

Homogeneous

100% Other None Detected

1217RW41-4 / 19064370-023

Coating

Various Non-Fibrous

Heterogeneous

100% Other None Detected

1217RW42-4 / 19064370-024

Wall

Grey Non-Fibrous

Heterogeneous

100% Other None Detected

Analyst:

Analysis Date: 12/31/2019 Date: 12/31/2019

Approved Signatory:

1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

20192002Project Number:

20192002P.O. Number:

Project Name: Building 4

12/17/2019Collected Date:

12/19/2019 11:00:00 AMReceived Date:

12/31/2019 2:17:59 PM

19064370 SanAir ID Number

FINAL REPORT

Hurt & Proffitt, Inc.Name:

Address: 2524 Langhorne Road

Lynchburg, VA 24501

Disclaimer

The final report cannot be reproduced, except in full, without written authorization from SanAir.

Fibers smaller than 5 microns cannot be seen with this method due to scope limitations. The accuracy of the results is dependent upon the client’s sampling procedure and information provided to the laboratory by the client. SanAir assumes no responsibility for the sampling procedure and will provide evaluation reports based solely on the sample and information provided by the client. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Samples are held for a period of 60 days.

For NY state samples, method EPA 600/M4-82-020 is performed.

Polarized- light microscopy is not consistently reliable in detecting asbestos in floor covering and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos containing.

Asbestos Certifications NVLAP lab code 200870 City of Philadelphia: ALL-460 PA Department of Environmental Protection Number: 68-05397 California License Number: 2915 Colorado License Number: AL-23143 Connecticut License Number: PH-0105 Massachusetts License Number: AA000222 Maine License Number: LB-0075 New York ELAP lab ID: 11983 Rhode Island License Number: AAL-126 Texas Department of State Health Services License Number: 300440 Commonwealth of Virginia 3333000323 Washington State License Number: C989 West Virginia License Number: LT000566 Vermont License: AL166318

Revision Date: 11/30/2017

ROANOKE, VA 24019

800-242-4906 TOLL FREE

540-521-1008 MAIN

www.HandP.com

ENGINEERING • SURVEYING • PLANNING • ENVIRONMENTAL • GIS

123 Bruton Court Suite 100 Chesapeake, Virginia 23322

Attention: James Collins, PE Ph: 757-389-5518 / Email: coliins@avetechdg.com

Subject: Building 5 Asbestos Testing Services Upgrade Fire Alarm System, Project #658-19-105

Hurt & Proffitt, Inc. (H&P) was requested to conduct sampling for asbestos containing materials (ACM) that will be impacted by the work for the Fire Alarm System Upgrade Project. This survey was conducted in Building 5 at the Salem Veterans Affairs Medical Center in Salem, Virginia. The sampling was performed by H&P representatives Mr. Roy Wriston (Virginia Asbestos Inspector License number is 3303 003648) and Ms. Mary Beth Wriston (Virginia Asbestos Inspector License number is 3303 003466) on December 17-18, 2019. This letter and attachments represent H&P’s report for the above-referenced project.

1.0 Asbestos Survey Procedures and Findings

H&P was provided with construction drawings showing the general locations where work is planned noting the specific work scope in the respective areas. Based on our review of the drawings, sampling was performed to target suspect ACM in each work area based on the work task type. The targeted sampling was limited to surfaces where components will be mounted and excluded materials that could be affected by running of lines since their routing will be determined in the field by the installation

The survey included the collection and submittal of 26 individual samples of suspect asbestos containing materials (ACM) that were analyzed for a total of 37 layers. The sampling was limited to non-invasive means and was performed in accordance with state and federal regulations.

The suspect asbestos samples were submitted for analysis by EPA Method No. 600/R-93/116 and 600/M4-82-020 polarized light microscopy (PLM). All samples were analyzed by SanAir Technologies analysis within the State of Virginia. The sampling results are shown in the following table. Copies of the laboratory Asbestos Analysis Bulk Report and Chain of Custody forms are included as an attachment to this report

Table I –Building 5–Asbestos Sample Analysis Results

Sample # Sample Type Lab Description. Sample Location Results Condition

1217RW01-5

Plaster-wall Tan Non-Fibrous

Basement

None Detected

Fair

Skim Coat-wall White Non-

Fibrous None

Detected Fair

1217RW02-5 Wall coating White Non-

Fibrous Basement

None Detected

Fair

1217RW03-5

2x2 Dotted ceiling tile

White Fibrous Basement Hall at elevator None

Detected Fair

1217RW04-5

2x2 Fissured ceiling tile White Fibrous

Basement Hall at elevator

None Detected

Fair

1217RW05-5

2x2 Dotted Ceiling Tile

White Fibrous Basement Med student bedroom None

Detected Fair

1217RW06-5

Drywall-wall White Non-

Fibrous Basement

Women’s Clinic Rest Room/Wall

None Detected

Fair

Plaster-wall Cream Non-

Fibrous None

Detected Fair

Skim coat-wall White Non-

Fibrous None

Detected Fair

1217RW07-5

2x2 Dotted ceiling tile

White Fibrous Basement Room

1M None

Detected Fair

1217RW08-5

2x2 Fissured ceiling tile White Fibrous

Basement Hall by Room 10

None Detected

Fair

1217RW09-5

Drywall-wall White Non-

Fibrous Basement Hall by Break Room

None Detected

Fair

Plaster-wall Gray Non-

Fibrous None

Detected Fair

1217RW10-5

2x2 Fissured ceiling tile White Fibrous

Basement Break Room

None Detected

Fair

1217RW11-5 Wall White Non-

Fibrous PACT Exam Room

Rest Room None

Detected Fair

1217RW12-5

2x4 Fissured ceiling tile White Fibrous

1st Floor Elevator Lobby

None Detected

Fair

1217RW13-5 Wall White Non-

Fibrous 1st Floor Elevator

Lobby None

Detected Fair

1217RW14-5 Wall White Non-

Fibrous 1st Floor Women’s

Rest Room None

Detected Fair

1217RW15-5 Plaster-wall Gray Non-

Fibrous Rest Room By 2nd Floor Call Center

None

Sample # Sample Type Lab Description. Sample Location Results Condition

Skim coat-wall White Non-

Fibrous None

Detected Fair

1217RW16-5 Wall Gray Non-

Fibrous 2nd Floor Office

Vestibule None

Detected Fair

1217RW17-5

Plaster-wall Tan Non-Fibrous 2nd Floor Break

Room

None Detected

Fair

Skim coat-wall White Non-

Fibrous None

Detected Fair

1217RW18-5 Wall White Fibrous Column in 2nd Floor corridor

None Detected

Fair

1217RW19-5

2x2 Fissured Ceiling Tile

White Fibrous 2nd Floor Elevator

Lobby None

Detected Fair

1217RW20-5

Insulation-wall panel

Yellow Fibrous 1st Floor

Auditorium

None Detected

Fair

Wrap-wall panel

Blue Fibrous None

Detected Fair

1217RW21-5

Fiber Board-wall

Tan Fibrous

1st Floor Auditorium by

Window

None Detected

Fair

Mastic-wall Tan Fibrous None

Detected Fair

Joint Compound-wall

White Non- Fibrous

None Detected

Fair

1217RW22-5

Plaster-wall Tan Non-Fibrous 1st Floor Kitchen

None Detected

Fair

Skim coat-wall White Non-

Fibrous None

Detected Fair

1217RW23-5

Plaster-wall Tan Non-Fibrous 2nd Floor Storage

Room

None Detected

Fair

Skim coat-wall White Non-

Fibrous None

Detected Fair

1217RW24-5 Mortar-wall Tan Non-Fibrous 1st Floor Enclosed

Porch None

Detected Fair

1217RW25-5

Plaster-wall Tan Non-Fibrous 1st Floor By Stage

Exit Door

None Detected

Fair

Skim Coat-wall Red Non- Fibrous

None Detected

Fair

1217RW26-5

Plaster-wall Cream Non-

Fibrous 1st Floor Enclosed Porch

None Detected

Fair

Skim coat-wall White Non-

Fibrous None

Detected

Based on the results of sample analysis, asbestos containing materials were not identified in the areas and materials sampled during this survey.

2.1 Presumed Asbestos Containing Materials

During the conduct of this survey, sampling was limited to those materials which were within the areas designated by the client, which were safely accessible, and were able to be sampled without damaging systems or structures. Additionally, the facility and multiple rooms were occupied and in use at the time or our survey; which limited our ability to access all areas. As such, other materials not represented in negative for asbestos. Some components that were not accessible and/or could not be sampled include:

core then this material must be presumed to be asbestos containing and should be treated as such;

unless sampling and analysis is performed and confirms the absence of asbestos in the material.

Thermal systems insulation that may be present in wall cavities or above ceilings and; if the scope of work will disturb the material, then it must be presumed to be asbestos containing and should be

If work is performed that will impact suspect materials that have not been sampled, it is recommended that they be sampled by a Virginia licensed Asbestos Inspector prior to disturbance. We note that during renovation or demolition activities, it is not uncommon to reveal materials that were not accessible during

3.1 EPA/NESHAP Regulations for Asbestos Containing Materials

The U.S. Environmental Protection Agency promulgated the National Emission Standards for Hazardous Air Pollutants (NESHAP) [40 CFR Part 61], which addresses the application, removal, and disposal of asbestos-containing materials (ACM). Under NESHAP the following categories are defined for asbestos-containing materials:

Friable - When dry, can be crumbled, pulverized, or reduced to powder by hand pressure.

Non-friable - When dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure.

Category I Non-friable ACM - Packings, gaskets, resilient floor coverings, and asphalt roofing products containing more than 1% asbestos.

Category II Non-friable ACM – Any material, excluding Category I Non-friable ACM, which contains more than 1% asbestos.

Regulated Asbestos Containing Material (RACM) – One of the following:

1. Friable ACM

2. Category I Non-friable ACM that has become friable.

3. Category I Non-friable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading.

4. Category II Non-friable ACM that has a high probability of becoming, or has become, friable by the inspect the affected facility or part of the facility where the demolition or renovation activities will

3. RACM need not be removed if:

a) It is Category I non-friable ACM that is not in poor condition.

b) It is on a facility component that is encased in concrete or other similar material and is adequately wet whenever exposed.

c) It was not accessible for testing and was therefore not discovered until after demolition began and because of the demolition the material cannot be safely removed.

demolition due to the fact that disturbance can damage them, create potential exposure to workers and occupants and make them friable. This recommendation is made as a best practice to reduce potential exposure and limit liability.

3.2 OSHA

The Occupational Safety and Health Administration (OSHA) regulates employee exposure to asbestos under 29 CFR 1926.1101 and 29 CFR 1926.1001. Work associated with known or suspect asbestos these regulations in addition to the noted EPA regulations where applicable.

If the materials that have been identified as asbestos containing will be disturbed or are in poor condition, it is recommended that the asbestos be removed by an appropriately trained and licensed asbestos abatement contractor in accordance with Virginia, EPA and OSHA regulations.

9.0 Limitations

This report summarizes the results of our sample collection and analysis of the suspect ACM materials at the facility based on our understanding of the requested scope of work. The findings prepared by H&P are based upon our observations and the analytical analysis of the samples collected at the time of our field inspection. The services performed were provided in accordance with generally accepted environmental industry standard practices. No warranty, expressed or implied, is made. Our observations, conclusions and recommendations are based upon conditions readily visible at the site at the time of our visit, the results of testing and analysis and information provided to us by others.

Our conclusions and recommendations are based on the guidelines presented by the EPA, Commonwealth of Virginia and OSHA. Any conditions discovered which deviate from the data contained in this report should be presented to us for our evaluation. This report has been prepared for the exclusive use of the client/or their agents. This service was performed in accordance with generally accepted environmental practices. Our conclusions and recommendations are based, in part, upon information provided to us by others; we have not verified the completeness or accuracy of the information provided by others, unless otherwise noted.

During H&P’s non-invasive inspection, accessible areas were visually surveyed for the presence of ACM.

Areas reviewed were limited to those identified by the Client and that could be readily and safely accessed. Our conclusions and recommendations are based on the results of our testing and cannot be used to form a professional opinion of conditions in other areas beyond those from which the samples were collected. It is possible that inaccessible areas, such as behind walls or above ceilings, may not have been surveyed and therefore conditions in these areas are unknown.

During this study, suspect asbestos samples were submitted for analysis at an NVLAP-accredited laboratory via polarized light microscopy. As with any similar survey of this nature, actual conditions exist only at the precise locations from which samples were collected. Certain inferences are based on the results of this sampling and related testing to form a professional opinion of conditions in areas beyond those from which the samples were collected. It is also understood that this is a limited survey so that it is possible that concealed materials may be present that were not accessible to us. No other warranty, expressed or implied, is made.

H&P assumes no responsibility regarding response actions initiated as a result of our findings; nor liability for the duties and responsibilities of the Client or building owner with respect to compliance with applicable regulations. Compliance with regulations are the responsibility of the Client or building owner g.whitt@handp.com or Mary Beth Wriston at 540-588-0941 or via email at m.wriston@handp.com. We appreciate the opportunity to serve as your environmental consultant.

Roanoke Office Roanoke Office

SanAir ID#: 19064373

Project Name: Building 5

Report Date: 12/31/2019

Analysis Report prepared for

We at SanAir would like to thank you for the work you recently submitted. The 26 sample(s) were received on Thursday, December 19, 2019 via FedEx. The final report(s) is enclosed for the following sample(s): 1217RW01-5, 1217RW02-5, 1217RW03-5, 1217RW04-5, 1217RW05-5, 1217RW06-5, 1217RW07-5, 1217RW08-5, 1217RW09-5, 1217RW10-5, 1217RW11-5, 1217RW12-5, 1217RW13-5, 1217RW14-5, 1217RW15-5, 1217RW16-5, 1217RW17-5, 1217RW18-5, 1217RW19-5, 1217RW20-5, 1217RW21-5, 1217RW22-5, 1217RW23-5, 1217RW24-5, 1217RW25-5, 1217RW26-5.

These results only pertain to this job and should not be used in the interpretation of any other job. This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.

Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory

Final Report Includes:

- Cover Letter

- Analysis Pages

- Disclaimers and Additional Information

Sample conditions:

- 26 samples in Good condition.

1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

20192002Project Number:

20192002P.O. Number:

Project Name: Building 5

12/17/2019 - 12/18/2019Collected Date:

12/19/2019 11:00:00 AMReceived Date:

12/31/2019 12:37:34 PM

19064373 SanAir ID Number

FINAL REPORT

Hurt & Proffitt, Inc.Name:

Address: 2524 Langhorne Road

Lynchburg, VA 24501

Analyst: Li, Elizabeth | Hogrefe, Sarah

Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers

1217RW01-5 / 19064373-001

Wall, Plaster

Tan Non-Fibrous

Homogeneous

100% Other None Detected

1217RW01-5 / 19064373-001

Wall, Skim Coat

White Non-Fibrous

Homogeneous

100% Other None Detected

1217RW02-5 / 19064373-002

Wall

White Non-Fibrous

Homogeneous

100% Other None Detected

1217RW03-5 / 19064373-003

Ceiling Tile

White Fibrous

Homogeneous

70% Cellulose 5% Glass

25% Other None Detected

1217RW04-5 / 19064373-004

Ceiling Tile

White Fibrous

Homogeneous

40% Cellulose 30% Glass

30% Other None Detected

1217RW05-5 / 19064373-005

Ceiling Tile

White Fibrous

Homogeneous

70% Cellulose 30% Other None Detected

1217RW06-5 / 19064373-006

Wall, Drywall

White Non-Fibrous

Homogeneous

5% Cellulose 95% Other None Detected

1217RW06-5 / 19064373-006

Wall, Plaster

Cream Non-Fibrous

Homogeneous

100% Other None Detected

1217RW06-5 / 19064373-006

Wall, Skim Coat

White Non-Fibrous

Homogeneous

100% Other None Detected

1217RW07-5 / 19064373-007

Ceiling Tile

White Fibrous

Homogeneous

40% Cellulose 30% Glass

30% Other None Detected

Analyst:

Analysis Date: 12/31/2019 Date: 12/31/2019

Approved Signatory:

20192002Project Number:

20192002P.O. Number:

Project Name: Building 5

12/17/2019 - 12/18/2019Collected Date:

12/19/2019 11:00:00 AMReceived Date:

12/31/2019 12:37:34 PM

19064373 SanAir ID Number

FINAL REPORT

Hurt & Proffitt, Inc.Name:

Address: 2524 Langhorne Road

Lynchburg, VA 24501

Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers

1217RW08-5 / 19064373-008

Ceiling Tile

White Fibrous

Homogeneous

40% Cellulose 30% Glass

30% Other None Detected

1217RW09-5 / 19064373-009

Wall, Drywall

White Non-Fibrous

Homogeneous

5% Cellulose 95% Other None Detected

1217RW09-5 / 19064373-009

Wall, Plaster

Gray Non-Fibrous

Homogeneous

100% Other None Detected

1217RW10-5 / 19064373-010

Ceiling Tile

White Fibrous

Homogeneous

50% Cellulose 20% Glass

30% Other None Detected

1217RW11-5 / 19064373-011

Wall

White Non-Fibrous

Homogeneous

100% Other None Detected

1217RW12-5 / 19064373-012

Ceiling Tile

White Fibrous

Homogeneous

40% Cellulose 30% Glass

30% Other None Detected

1217RW13-5 / 19064373-013

Wall

White Non-Fibrous

Homogeneous

100% Other None Detected

1217RW14-5 / 19064373-014

Wall

White Non-Fibrous

Homogeneous

100% Other None Detected

1217RW15-5 / 19064373-015

Wall, Plaster

Gray Non-Fibrous

Homogeneous

100% Other None Detected

1217RW15-5 / 19064373-015

Wall, Skim Coat

White Non-Fibrous

Homogeneous

100% Other None Detected

Analyst:

Analysis Date: 12/31/2019 Date: 12/31/2019

Approved Signatory:

1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

20192002Project Number:

20192002P.O. Number:

Project Name: Building 5

12/17/2019 - 12/18/2019Collected Date:

12/19/2019 11:00:00 AMReceived Date:

12/31/2019 12:37:34 PM

19064373 SanAir ID Number

FINAL REPORT

Hurt & Proffitt, Inc.Name:

Address: 2524 Langhorne Road

Lynchburg, VA 24501

Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers

1217RW16-5 / 19064373-016

Wall

Gray Non-Fibrous

Homogeneous

100% Other None Detected

1217RW17-5 / 19064373-017

Wall, Plaster

Tan Non-Fibrous

Homogeneous

100% Other None Detected

1217RW17-5 / 19064373-017

Wall, Skim Coat

White Non-Fibrous

Homogeneous

100% Other None Detected

1217RW18-5 / 19064373-018

Wall

White Non-Fibrous

Homogeneous

100% Other None Detected

1217RW19-5 / 19064373-019

Ceiling Tile

White Fibrous

Homogeneous

40% Cellulose 30% Glass

30% Other None Detected

1217RW20-5 / 19064373-020

Wall, Insulation

Yellow Fibrous

Homogeneous

98% Glass 2% Other None Detected

1217RW20-5 / 19064373-020

Wall, Wrap

Blue Fibrous

Homogeneous

98% Synthetic 2% Other None Detected

1217RW21-5 / 19064373-021

Wall, Fiberboard

Tan Fibrous

Homogeneous

90% Cellulose 10% Other None Detected

1217RW21-5 / 19064373-021

Wall, Mastic

Tan Non-Fibrous

Homogeneous

100% Other None Detected

1217RW21-5 / 19064373-021

Wall, Joint Compound

White Non-Fibrous

Homogeneous

100% Other None Detected

Analyst:

Analysis Date: 12/31/2019 Date: 12/31/2019

Approved Signatory:

1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

20192002Project Number:

20192002P.O. Number:

Project Name: Building 5

12/17/2019 - 12/18/2019Collected Date:

12/19/2019 11:00:00 AMReceived Date:

12/31/2019 12:37:34 PM

19064373 SanAir ID Number

FINAL REPORT

Hurt & Proffitt, Inc.Name:

Address: 2524 Langhorne Road

Lynchburg, VA 24501

Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers

1217RW22-5 / 19064373-022

Wall, Plaster

Tan Non-Fibrous

Homogeneous

100% Other None Detected

1217RW22-5 / 19064373-022

Wall, Skim Coat

White Non-Fibrous

Homogeneous

100% Other None Detected

1217RW23-5 / 19064373-023

Wall, Plaster

Tan Non-Fibrous

Homogeneous

100% Other None Detected

1217RW23-5 / 19064373-023

Wall, Skim Coat

White Non-Fibrous

Homogeneous

100% Other None Detected

1217RW24-5 / 19064373-024

Wall

Tan Non-Fibrous

Homogeneou…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .