S05 RFI Question 12 and 13.pdf
PDF 14 MB Posted
- Solicitation number
- 36C24621B0019
About this file
This document provides details on a federal contract opportunity to upgrade fire alarm systems. The solicitation number is 36C24621B0019 and is being issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 6. The project title is Upgrade Fire Alarm System with project number 658-19-105. The opportunity type is a solicitation to upgrade fire alarm systems at a Veterans Affairs medical center. No further specifics on requirements, pricing, or response deadlines are included in this document.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24621B0019 0004_1.docx | DOCX document | |
| S06 36C24621B0019 0004.pdf | ||
| 36C24621B0019 0003_1.docx | DOCX document | |
| S05 RFI Questions 11-9-2021.pdf | ||
| S02 36C24621B0019 0002.pdf | ||
| 36C24621B0019 0002_1.docx | DOCX document | |
| 36C24621B0019 0001_1.docx | DOCX document | |
| 36C24621B0019 0001.pdf | ||
| FAR Class Deviation 52.223-99 Clause.pdf | ||
| S04 Site Visit Upgrade Fire Alarm Sys. 10-12-21.pdf | ||
| S02_36C24621B0019.pdf | ||
| Upgade Fire Alarm_Specs 658-19-105.pdf | ||
| 36C24621B0019_1.docx | DOCX document | |
| Upgrade Fire Alarm_Drawings 658-19-105.pdf |
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
5238 VALLEYPOINTE PARKWAY
SUITE 2B, BUILDING C
ROANOKE, VA 24019
800-242-4906 TOLL FREE
540-521-1008 MAIN
www.HandP.com
ENGINEERING • SURVEYING • PLANNING • ENVIRONMENTAL • GIS
HURT & PROFFITT
Inspired | Responsive | Trusted
April 15, 2020
Avetech Design Group 123 Bruton Court, Suite 100 Chesapeake, Virginia 23322
Attention: James Collins, PE Ph: 757-389-5518 / Email: coliins@avetechdg.com
Subject: Asbestos Testing Services Summary Sheet Upgrade Fire Alarm System, Project #658-19-105 Salem VA Medical Center in Salem, Virginia H&P Project 20192002
Mr. Collins, Hurt & Proffitt, Inc. (H&P) was requested to conduct sampling of asbestos containing materials (ACM) in the areas that will be impacted by the work for the Fire Alarm System Upgrade Project. For the surveys, H&P was provided with construction drawings showing the locations where work is planned noting the specific work scope in the respective area. Based on our review of the drawings, sampling was performed on targeted suspect ACM in each work. The targeted sampling was limited to surfaces where components will be mounted and excluded those that could be affected by running of lines since their routing will be determined in the field by the installation contractor. Below is a summary of the materials that were identified as asbestos containing by sampling and analysis listed per building. For a detailed listing of all materials sampled, refer to the respective building’s Asbestos Survey Report.
Building 04
Asbestos containing materials were not identified in the areas and materials sampled during this survey.
Building 05
Asbestos containing materials were not identified in the areas and materials sampled during this survey.
Building 09
Asbestos (3% Chrysotile) was identified in the white mastic on ducting collected on the basement level in Room 2. All similar white duct mastic should be presumed to be asbestos containing.
Building 11
Asbestos (3% Chrysotile) was identified in the white mastic on ducting collected in the 2nd floor hall by Room 223. All similar white duct mastic should be presumed to be asbestos containing.
mailto:coliins@avetechdg.com
A trace (<1%) level of asbestos was detected in the caulking in the brick mortar joints located in the 1st floor exterior open porch area. This level is below the regulatory threshold under EPA regulations for defining a material as regulated and “asbestos containing”. However, OSHA has regulations for the removal and disturbance of trace levels of asbestos; therefore, H&P recommends that the owner assume that all similar caulking in the area is asbestos containing at a trace level.
Building 13
Asbestos containing materials were not identified in the areas and materials sampled during this survey.
Building 14
Asbestos containing materials were not identified in the areas and materials sampled during this survey.
Building15
A trace (<1%) level of asbestos was detected in the plaster skim coat on the wall in the 1st floor hallway.
This level is below the regulatory threshold under EPA regulations for defining a material as regulated and “asbestos containing”. However OSHA has regulations for the removal and disturbance of trace levels of asbestos; therefore, H&P recommends that the owner assume that all skim coat in the area is asbestos containing at a trace level.
Building16
Asbestos containing materials were not identified in the areas and materials sampled during this survey.
Building 75
Asbestos (5% Chrysotile) was identified in the white duct mastic collected in the 2nd floor hall by Room
252. All similar white duct mastic should be presumed to be asbestos containing.
Asbestos (3% Chrysotile) was identified in the white duct mastic collected in the basement level in Room
12. All similar white duct mastic should be presumed to be asbestos containing.
A trace (<1%) level of asbestos was detected in the drywall joint compound collected on the 1st floor hallway area by the stairwell. This level is below the regulatory threshold under EPA regulations for defining a material as regulated and “asbestos containing”. OSHA has regulations for the removal and disturbance of trace levels of asbestos; therefore, H&P recommends that the owner assume that all joint compound in the area is asbestos containing at a trace level.
Building76
Asbestos (2% Chrysotile) was identified in the drywall joint compound collected in the basement level in the Locksmith Room. All similar wall joint compounds should be presumed to be asbestos containing.
Building 145
Asbestos containing materials were not identified in the areas and materials sampled during this survey.
Presumed Asbestos Containing Materials
During the conduct of this survey, sampling was limited to those materials which were within the areas designated by the client, which were safely accessible, and were able to be sampled without damaging systems or structures. Additionally, the facility and multiple rooms were occupied and in use at the time or our survey; which limited our ability to access all areas. As such, other materials not represented in the respective building’s survey should be presumed to be positive, unless sampling is conducted and they are shown to be negative for asbestos. Some components that were not accessible and/or could not be sampled include:
Electrical equipment wiring (i.e. control panels) and switches and panel backer boards;
Fire doors where magnetic locks will be installed. If the scope of work will disturb the inner door core, then this material must be presumed to be asbestos containing and should be treated as such;
unless sampling and analysis is performed and confirms the absence of asbestos in the material.
Thermal systems insulation that may be present in wall cavities or above ceilings and; if the scope of work will disturb the material, then it must be presumed to be asbestos containing and should be treated as such, unless sampling and analysis is performed and confirms the absence of asbestos in the material.
If work is performed that will impact suspect materials that have not been sampled, it is recommended that they be sampled by a Virginia licensed Asbestos Inspector prior to disturbance.
Closing
Should you have any questions please contact Greg Whitt at (540) 521-1008 or via email at g.whitt@handp.com or Mary Beth Wriston at 540-588-0941 or via email at m.wriston@handp.com. We appreciate the opportunity to serve as your environmental consultant.
Sincerely, HURT & PROFFITT, INC
Gregory L. Whitt Roy Wriston Environmental/Industrial Hygiene Manager Environmental/Industrial Hygiene Senior Roanoke Office Roanoke Office mailto:g.whitt@handp.com mailto:m.wriston@handp.com
ROANOKE, VA 24019
800-242-4906 TOLL FREE
540-521-1008 MAIN
www.HandP.com
ENGINEERING • SURVEYING • PLANNING • ENVIRONMENTAL • GIS
February 4, 2020
123 Bruton Court Suite 100 Chesapeake, Virginia 23322
Attention: James Collins, PE Ph: 757-389-5518 / Email: coliins@avetechdg.com
Subject: Building 4 Asbestos Testing Services Upgrade Fire Alarm System, Project #658-19-105
Hurt & Proffitt, Inc. (H&P) was requested to conduct sampling for asbestos containing materials (ACM) that will be impacted by the work for the fire Alarm System Upgrade Project. This survey was conducted in Building 4 at the Salem Veterans Affairs Medical Center in Salem, Virginia. The sampling was performed by H&P representatives Mr. Roy Wriston (Virginia Asbestos Inspector License number is 3303 003648) and Ms. Mary Beth Wriston (Virginia Asbestos Inspector License number is 3303 003466) on December 16-17, 2019 and January 10, 2020. This letter and attachments represent H&P’s report for the above-referenced project.
1.0 Asbestos Survey Procedures and Findings
H&P was provided with construction drawings showing the general locations where work is planned noting the specific work scope in the respective areas. Based on our review of the drawings, sampling was performed to target suspect ACM in each work area based on the work task type. The targeted sampling was limited to surfaces where components will be mounted and excluded materials that could be affected by running of lines since their routing will be determined in the field by the installation contractor. Therefore, the approach of the survey was to sample representative suspect ACM in the locations designated on the drawings in order to provide an understanding of:
Materials that are asbestos containing and require abated prior to disturbance;
Identify those that are not asbestos containing via sampling and analysis.
The survey included the collection and submittal of 50 individual samples of suspect asbestos containing materials (ACM) that were analyzed for a total of 75 layers. The sampling was limited to non-invasive means and was performed in accordance with state and federal regulations.
The suspect asbestos samples were submitted for analysis by EPA Method No. 600/R-93/116 and 600/M4-82-020 polarized light microscopy (PLM). All samples were analyzed by SanAir Technologies
Laboratory of Powhatan, Virginia, a NVLAP accredited laboratory licensed to perform asbestos bulk analysis within the State of Virginia. The sampling results are shown in the following table. Copies of the laboratory Asbestos Analysis Bulk Report and Chain of Custody forms are included as an attachment to this report
Table I –Building 4–Asbestos Sample Analysis Results
Sample # Sample Type Lab Description Sample Location Results Condition
1216RW01-4
2x4 white fissured ceiling tile
White Fibrous 2nd Floor hall by elevator None
Detected Fair
1216RW02-4
2x2 off-white fissured ceiling tile
White Fibrous 2nd Floor hall by elevator None
Detected Fair
1216RW03-4
Plaster-wall Tan Non-Fibrous 2nd Floor stair entry in lobby by elevator
None Detected
Fair
Skim coat-wall White Non-
Fibrous None
Detected Fair
1216RW04-4
2x2 Off-white ceiling tile White Fibrous
2nd Floor Hall by Room 202
None Detected
Fair
1216RW05-4
Drywall-wall White Non-
Fibrous 2nd Floor
Women’s Rest Room
None Detected
Fair
Plaster-wall Beige Non-
Fibrous None
Detected Fair
Skim coat-wall White Non-
Fibrous None
Detected Fair
1216RW06-4
2x2 Off-white ceiling tile White-Fibrous
2nd Floor Hall by Room 215
None Detected
Fair
1216RW07-4
Plaster-wall Tan Non-Fibrous
2nd Floor Hall end by Exit door
None Detected
Fair
Skim coat-wall White Non-
Fibrous None
Detected Fair
1216RW08-4
2x4 Fissured ceiling tile White Fibrous
1st Floor Office of Simulator Center
None Detected
Fair
1216RW09-4
Drywall-ceiling
White Non- Fibrous 1st Floor Lab of
Simulator Center
None Detected
Fair
Texture-ceiling White Non-
Fibrous None
Detected Fair
1216RW10-4
Drywall-wall Brown Non-
Fibrous 1st Floor
Women’s Rest Room by
Simulator Center
None Detected
Fair
Joint Compound-wall
White Non- Fibrous
None Detected
Fair
Sample # Sample Type Lab Description Sample Location Results Condition
1216RW11-4
2x4 White fissured ceiling tile
White Fibrous 1st Floor Hall by
Room 106 None
Detected Fair
1216RW12-4
2x2 Off-white ceiling tile White Fibrous
1st Floor Hall by Room 106
None Detected
Fair
1216RW13-4
Plaster-wall
Brown Non- Fibrous
1st Floor At door to Stairwell by room 107
None Detected
Fair
Skim coat-wall White Non-
Fibrous None
Detected Fair
1216RW14-4 Drywall-wall White Non-
Fibrous 1st Floor Room
None
Detected Fair
1216RW15-4
2x4 Fissured ceiling tile White Fibrous
1st Floor Hall by Room 112
None Detected
Fair
1216RW16-4
Drywall-wall
White Non- Fibrous
1st Floor Kitchen
None Detected
Fair
Tile-wall White Non-
Fibrous None
Detected Fair
1216RW17-4
Drywall-wall White Non-
Fibrous
1st Floor Dry Storage
None Detected
Fair
Drywall-wall Brown Non-
Fibrous None
Detected Fair
Tile-wall White Non-
Fibrous None
Detected Fair
1216RW18-4 2x4 Ceiling Tile Grey Non-
Fibrous
1st Floor Ingredient control area
None Detected
Fair
1217RW19-4 Wall coating Tan Non-Fibrous 2nd Floor locker room None
Detected Fair
1217RW20-4 Wall coating Red Non- Fibrous
2nd Floor Storage room
None Detected
Fair
1217RW21-4 Ceiling coating Tan Non-Fibrous 2nd Floor Elevator room None
Detected Fair
1217RW22-4 Wall coating Brown Non-
Fibrous 2nd Floor
Penthouse None
Detected Fair
1217RW23-4
Plaster ceiling
Beige Non- Fibrous
1st Floor Stairwell lobby by room
None Detected
Fair
Skim coat ceiling White Non-
Fibrous None
Detected Fair
1217RW24-4
Plaster-wall Beige Non-
Fibrous Basement Women’s
Restroom/Wall
None Detected
Fair
Skim Coat-wall White Non-
Fibrous None
1217RW25-4 2x2 Ceiling tile White Fibrous Basement Women’s Restroom
None Detected
Fair
1217RW26-4
Plaster-wall White Non-
Fibrous Basement Post office
None Detected
Fair
Skim coat-wall White Non-
Fibrous None
Detected Fair
1217RW27-4
2x4 Fissured Ceiling tile
White Fibrous Basement Hall by Room Women’s
Restroom
None Detected
Fair
1217RW28-4
2x2 Dotted ceiling tile
White Fibrous Basement By
Building 2 crossover
None Detected
Fair
1217RW29-4
2x2 Fissured ceiling tile White Fibrous
Basement Hall by room 13
None Detected
Fair
1217RW30-4
Plaster-wall Tan Non-Fibrous Basement Canteen storage room
None Detected
Fair
Skim coat-wall White Non-
Fibrous None
Detected Fair
1217RW31-4
Drywall-wall Grey Non-fibrous Basement
Cushman cart charging room
None Detected
Fair
Plaster-wall White Non-
Fibrous None
Detected Fair
Skim coat-wall White Non-
Fibrous None
Detected Fair
1217RW32-4 Wall coating White Non-
Fibrous Basement Room
None
Detected Fair
1217RW33-4
Plaster-wall Grey Non-
Fibrous Basement
Kitchen general storage
None Detected
Fair
Skim coat-wall White non-
Fibrous None
Detected Fair
1217RW34-4
Plaster-wall Grey Non-
Fibrous Basement Dry storage
None Detected
Fair
Skim coat-wall Grey Non-
Fibrous
None Detected
Fair
1217RW35-4
2x4 Dotted ceiling tile
White Fibrous Basement Cafeteria
None Detected
Fair
1217RW36-4
Plaster-wall Grey Non-
Fibrous Basement
Women’s locker room
None Detected
Fair
Skim coat-wall White Non-
Fibrous None
Detected Fair
1217RW37-4 Hard ceiling tile White Non-
Fibrous Basement
Kitchen None
1217RW38-4 2x4 Ceiling tile White Fibrous Basement Retail canteen area None
Detected Fair
1217RW39-4 Wall coating Grey Non-
Fibrous Basement
Dietetic storage None
Detected Fair
1217RW40-4
Plaster-wall Red Non- Fibrous Basement Barber
Shop
None Detected
Fair
Skim coat-wall White Non-
Fibrous None
Detected Fair
1217RW41-4
Black coating-wall Various Non-
Fibrous Basement Room
None
Detected Fair
1217RW42-4 Wall Grey Non-
Fibrous Basement Room
None
Detected Fair
110RW01-4 Duct mastic White Non-
Fibrous Attic-AHU-6
None Detected
Fair
110RW02-4
Duct mastic
White Non- Fibrous
Attic-4-AHU-3
None Detected
Fair
Duct Insulation Yellow Fibrous None
110RW03-4 Duct mastic White Non-
Fibrous Attic-AHU-4-5
None Detected
Fair
110RW04-4
Duct mastic
White Non- Fibrous
Attic-AHU-4-5
None Detected
Fair
Duct insulation Yellow Fibrous None
Detected Fair
110RW05-4 Duct mastic White Non-
Fibrous Attic-Farthest
Back AHU None
Detected Fair
110RW06-4
Duct mastic
White Non- Fibrous Penthouse-4-
AHU-2 Front
None Detected
Fair
Duct insulation Yellow Fibrous None
Detected Fair
110RW07-4
Duct mastic
White Non- Fibrous Penthouse-4-
AHU-2 Back
None Detected
Fair
Duct insulation Yellow Fibrous None
Detected Fair
110RW08-4
Duct mastic
White Non- Fibrous Penthouse-4-
AHU-2 Large
None Detected
Fair
Duct insulation Yellow Fibrous None
Detected
None Detected: No Asbestos Detected
2.0 Analysis Results
Based on the results of sample analysis, asbestos containing materials were not identified in the areaas and materials sampled during this survey.
2.1 Presumed Asbestos Containing Materials
During the conduct of this survey, sampling was limited to those materials which were within the areas designated by the client, which were safely accessible, and were able to be sampled without damaging systems or structures. Additionally, the facility and multiple rooms were occupied and in use at the time or our survey; which limited our ability to access all areas. As such, other materials not represented in this survey should be presumed to be positive, unless sampling is conducted and they are shown to be negative for asbestos. Some components that were not accessible and/or could not be sampled include:
core, then this material must be presumed to be asbestos containing and should be treated as such;
unless sampling and analysis is performed and confirms the absence of asbestos in the material.
Thermal systems insulation that may be present in wall cavities or above ceilings and; if the scope of work will disturb the material, then it must be presumed to be asbestos containing and should be
If work is performed that will impact suspect materials that have not been sampled, it is recommended that they be sampled by a Virginia licensed Asbestos Inspector prior to disturbance. We note that during renovation or demolition activities, it is not uncommon to reveal materials that were not accessible during the survey or their presence could not otherwise be known.
3.0 Applicable Regulations
Following are some applicable regulations pertaining to asbestos containing materials.
3.1 EPA/NESHAP Regulations for Asbestos Containing Materials
The U.S. Environmental Protection Agency promulgated the National Emission Standards for Hazardous Air Pollutants (NESHAP) [40 CFR Part 61], which addresses the application, removal, and disposal of asbestos-containing materials (ACM). Under NESHAP the following categories are defined for asbestos-containing materials:
Friable - When dry, can be crumbled, pulverized, or reduced to powder by hand pressure.
Non-friable - When dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure.
Category I Non-friable ACM - Packings, gaskets, resilient floor coverings, and asphalt roofing products containing more than 1% asbestos.
Category II Non-friable ACM – Any material, excluding Category I Non-friable ACM, which contains more than 1% asbestos.
Regulated Asbestos Containing Material (RACM) – One of the following:
1. Friable ACM
2. Category I Non-friable ACM that has become friable.
3. Category I Non-friable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading.
4. Category II Non-friable ACM that has a high probability of becoming, or has become, friable by the forces expected to act on the material in the course of demolition or renovation operations.
Under NESHAP, the following actions are required:
1. Prior to the commencement of demolition or renovation activities, the building owner must inspect the affected facility or part of the facility where the demolition or renovation activities will occur for the presence of asbestos.
2. Remove all RACM from the facility before any activity begins that would break up, dislodge, or similarly disturb the material or preclude access for subsequent removal.
3. RACM need not be removed if:
a) It is Category I non-friable ACM that is not in poor condition.
b) It is on a facility component that is encased in concrete or other similar material and is adequately wet whenever exposed.
c) It was not accessible for testing and was therefore not discovered until after demolition began and because of the demolition the material cannot be safely removed.
d) It is Category II non-friable ACM and the probability is low that the material will become crumbled, pulverized, or reduced to powder during demolition.
Note: Based on our experience, we recommend that all ACM be removed prior to renovation or demolition due to the fact that disturbance can damage them, create potential exposure to workers and occupants and make them friable. This recommendation is made as a best practice to reduce potential exposure and limit liability.
3.2 OSHA
The Occupational Safety and Health Administration (OSHA) regulates employee exposure to asbestos under 29 CFR 1926.1101 and 29 CFR 1926.1001. Work associated with known or suspect asbestos containing materials (ACM), including trace (<1%) levels of asbestos, must be conducted according to these regulations in addition to the noted EPA regulations where applicable.
If the materials that have been identified as asbestos containing will be disturbed or are in poor condition, it is recommended that the asbestos be removed by an appropriately trained and licensed asbestos abatement contractor in accordance with Virginia, EPA and OSHA regulations.
9.0 Limitations
This report summarizes the results of our sample collection and analysis of the suspect ACM materials at the facility based on our understanding of the requested scope of work. The findings prepared by H&P are based upon our observations and the analytical analysis of the samples collected at the time of our field inspection. The services performed were provided in accordance with generally accepted environmental industry standard practices. No warranty, expressed or implied, is made. Our observations, conclusions and recommendations are based upon conditions readily visible at the site at the time of our visit, the results of testing and analysis and information provided to us by others.
Our conclusions and recommendations are based on the guidelines presented by the EPA, Commonwealth of Virginia and OSHA. Any conditions discovered which deviate from the data contained in this report should be presented to us for our evaluation. This report has been prepared for the exclusive use of the client/or their agents. This service was performed in accordance with generally accepted environmental practices. Our conclusions and recommendations are based, in part, upon information provided to us by others; we have not verified the completeness or accuracy of the information provided by others, unless otherwise noted.
During H&P’s non-invasive inspection, accessible areas were visually surveyed for the presence of ACM.
Areas reviewed were limited to those identified by the Client and that could be readily and safely accessed. Our conclusions and recommendations are based on the results of our testing and cannot be used to form a professional opinion of conditions in other areas beyond those from which the samples were collected. It is possible that inaccessible areas, such as behind walls or above ceilings, may not have been surveyed and therefore conditions in these areas are unknown.
During this study, suspect asbestos samples were submitted for analysis at an NVLAP-accredited laboratory via polarized light microscopy. As with any similar survey of this nature, actual conditions exist only at the precise locations from which samples were collected. Certain inferences are based on the results of this sampling and related testing to form a professional opinion of conditions in areas beyond those from which the samples were collected. It is also understood that this is a limited survey so that it is possible that concealed materials may be present that were not accessible to us. No other warranty, expressed or implied, is made.
H&P assumes no responsibility regarding response actions initiated as a result of our findings; nor liability for the duties and responsibilities of the Client or building owner with respect to compliance with applicable regulations. Compliance with regulations are the responsibility of the Client or building owner in accordance with local, state, and/or federal requirements.
g.whitt@handp.com or Mary Beth Wriston at 540-588-0941 or via email at m.wriston@handp.com. We appreciate the opportunity to serve as your environmental consultant.
Gregory L. Whitt Mary Beth Wriston
Roanoke Office Roanoke Office
Appendices:
Appendix I – Asbestos Laboratory Analysis Report and Chain of Custody Forms
APPENDIX I
Asbestos Analysis Bulk Report
Chain of Custody Forms
SanAir ID#: 19064370
Project #: 20192002
Project Name: Building 4
Report Date: 12/31/2019
Analysis Report prepared for Hurt & Proffitt, Inc.
Dear Roy Wriston, We at SanAir would like to thank you for the work you recently submitted. The 24 sample(s) were received on Thursday, December 19, 2019 via FedEx. The final report(s) is enclosed for the following sample(s): 1217RW19-4, 1217RW20-4, 1217RW21-4, 1217RW22-4, 1217RW23-4, 1217RW24-4, 1217RW25-4, 1217RW26-4, 1217RW27-4, 1217RW28-4, 1217RW29-4, 1217RW30-4, 1217RW31-4, 1217RW32-4, 1217RW33-4, 1217RW34-4, 1217RW35-4, 1217RW36-4, 1217RW37-4, 1217RW38-4, 1217RW39-4, 1217RW40-4, 1217RW41-4, 1217RW42-4.
These results only pertain to this job and should not be used in the interpretation of any other job. This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.
Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory
Final Report Includes:
- Cover Letter
- Analysis Pages
- Disclaimers and Additional Information
Sample conditions:
- 24 samples in Good condition.
1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com
20192002Project Number:
20192002P.O. Number:
Project Name: Building 4
12/17/2019Collected Date:
12/19/2019 11:00:00 AMReceived Date:
12/31/2019 2:17:59 PM
19064370 SanAir ID Number
FINAL REPORT
Hurt & Proffitt, Inc.Name:
Address: 2524 Langhorne Road
Lynchburg, VA 24501
434-841-3893 (c)Phone:
Analyst: Moore, Brandi | Upshaw, Zoe
Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components
SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers
1217RW19-4 / 19064370-001
Wall
Tan Non-Fibrous
Homogeneous
100% Other None Detected
1217RW20-4 / 19064370-002
Wall
Red Non-Fibrous
Homogeneous
100% Other None Detected
1217RW21-4 / 19064370-003
Ceiling
Tan Non-Fibrous
Homogeneous
100% Other None Detected
1217RW22-4 / 19064370-004
Wall
Brown Non-Fibrous
Homogeneous
100% Other None Detected
1217RW23-4 / 19064370-005
Ceiling, Plaster
Beige Non-Fibrous
Homogeneous
100% Other None Detected
1217RW23-4 / 19064370-005
Ceiling, Skim Coat
White Non-Fibrous
Homogeneous
100% Other None Detected
1217RW24-4 / 19064370-006
Wall, Plaster
Beige Non-Fibrous
Homogeneous
100% Other None Detected
1217RW24-4 / 19064370-006
Wall, Skim Coat
White Non-Fibrous
Homogeneous
100% Other None Detected
1217RW25-4 / 19064370-007
Ceiling Tile
White Fibrous
Homogeneous
65% Cellulose 20% Glass
15% Other None Detected
1217RW26-4 / 19064370-008
Wall, Plaster
White Non-Fibrous
Homogeneous
100% Other None Detected
Analyst:
Analysis Date: 12/31/2019 Date: 12/31/2019
Approved Signatory:
20192002Project Number:
20192002P.O. Number:
Project Name: Building 4
12/17/2019Collected Date:
12/19/2019 11:00:00 AMReceived Date:
12/31/2019 2:17:59 PM
19064370 SanAir ID Number
FINAL REPORT
Hurt & Proffitt, Inc.Name:
Address: 2524 Langhorne Road
Lynchburg, VA 24501
Stereoscopic Components
SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers
1217RW26-4 / 19064370-008
Wall, Skim Coat
White Non-Fibrous
Homogeneous
100% Other None Detected
1217RW27-4 / 19064370-009
Ceiling Tile
White Fibrous
Homogeneous
65% Cellulose 20% Glass
15% Other None Detected
1217RW28-4 / 19064370-010
Ceiling Tile
White Fibrous
Homogeneous
65% Cellulose 20% Glass
15% Other None Detected
1217RW29-4 / 19064370-011
Ceiling Tile
White Fibrous
Homogeneous
50% Cellulose 40% Glass
10% Other None Detected
1217RW30-4 / 19064370-012
Wall, Plaster
Tan Non-Fibrous
Homogeneous
100% Other None Detected
1217RW30-4 / 19064370-012
Wall, Skim Coat
White Non-Fibrous
Homogeneous
100% Other None Detected
1217RW31-4 / 19064370-013
Wall, Drywall
Grey Non-Fibrous
Homogeneous
100% Other None Detected
1217RW31-4 / 19064370-013
Wall, Plaster
White Non-Fibrous
Homogeneous
100% Other None Detected
1217RW31-4 / 19064370-013
Wall, Skim Coat
White Non-Fibrous
Homogeneous
100% Other None Detected
1217RW32-4 / 19064370-014
Wall
White Non-Fibrous
Homogeneous
100% Other None Detected
Analyst:
Analysis Date: 12/31/2019 Date: 12/31/2019
Approved Signatory:
1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com
20192002Project Number:
20192002P.O. Number:
Project Name: Building 4
12/17/2019Collected Date:
12/19/2019 11:00:00 AMReceived Date:
12/31/2019 2:17:59 PM
19064370 SanAir ID Number
FINAL REPORT
Hurt & Proffitt, Inc.Name:
Address: 2524 Langhorne Road
Lynchburg, VA 24501
Stereoscopic Components
SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers
1217RW33-4 / 19064370-015
Wall, Plaster
Grey Non-Fibrous
Homogeneous
100% Other None Detected
1217RW33-4 / 19064370-015
Wall, Skim Coat
White Non-Fibrous
Homogeneous
100% Other None Detected
1217RW34-4 / 19064370-016
Wall, Plaster
Grey Non-Fibrous
Homogeneous
100% Other None Detected
1217RW34-4 / 19064370-016
Wall, Skim Coat
Grey Non-Fibrous
Homogeneous
100% Other None Detected
1217RW35-4 / 19064370-017
Ceiling Tile
White Fibrous
Homogeneous
40% Cellulose 40% Glass
20% Other None Detected
1217RW36-4 / 19064370-018
Wall, Plaster
Grey Non-Fibrous
Homogeneous
100% Other None Detected
1217RW36-4 / 19064370-018
Wall, Skim Coat
White Non-Fibrous
Homogeneous
100% Other None Detected
1217RW37-4 / 19064370-019
Ceiling Tile
White Non-Fibrous
Homogeneous
5% Cellulose 95% Other None Detected
1217RW38-4 / 19064370-020
Ceiling Tile
White Fibrous
Homogeneous
40% Cellulose 40% Glass
20% Other None Detected
1217RW39-4 / 19064370-021
Wall
Grey Non-Fibrous
Homogeneous
100% Other None Detected
Analyst:
Analysis Date: 12/31/2019 Date: 12/31/2019
Approved Signatory:
1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com
20192002Project Number:
20192002P.O. Number:
Project Name: Building 4
12/17/2019Collected Date:
12/19/2019 11:00:00 AMReceived Date:
12/31/2019 2:17:59 PM
19064370 SanAir ID Number
FINAL REPORT
Hurt & Proffitt, Inc.Name:
Address: 2524 Langhorne Road
Lynchburg, VA 24501
Stereoscopic Components
SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers
1217RW40-4 / 19064370-022
Wall, Plaster
Red Non-Fibrous
Heterogeneous
100% Other None Detected
1217RW40-4 / 19064370-022
Wall, Skim Coat
White Non-Fibrous
Homogeneous
100% Other None Detected
1217RW41-4 / 19064370-023
Coating
Various Non-Fibrous
Heterogeneous
100% Other None Detected
1217RW42-4 / 19064370-024
Wall
Grey Non-Fibrous
Heterogeneous
100% Other None Detected
Analyst:
Analysis Date: 12/31/2019 Date: 12/31/2019
Approved Signatory:
1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com
20192002Project Number:
20192002P.O. Number:
Project Name: Building 4
12/17/2019Collected Date:
12/19/2019 11:00:00 AMReceived Date:
12/31/2019 2:17:59 PM
19064370 SanAir ID Number
FINAL REPORT
Hurt & Proffitt, Inc.Name:
Address: 2524 Langhorne Road
Lynchburg, VA 24501
Disclaimer
The final report cannot be reproduced, except in full, without written authorization from SanAir.
Fibers smaller than 5 microns cannot be seen with this method due to scope limitations. The accuracy of the results is dependent upon the client’s sampling procedure and information provided to the laboratory by the client. SanAir assumes no responsibility for the sampling procedure and will provide evaluation reports based solely on the sample and information provided by the client. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Samples are held for a period of 60 days.
For NY state samples, method EPA 600/M4-82-020 is performed.
Polarized- light microscopy is not consistently reliable in detecting asbestos in floor covering and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos containing.
Asbestos Certifications NVLAP lab code 200870 City of Philadelphia: ALL-460 PA Department of Environmental Protection Number: 68-05397 California License Number: 2915 Colorado License Number: AL-23143 Connecticut License Number: PH-0105 Massachusetts License Number: AA000222 Maine License Number: LB-0075 New York ELAP lab ID: 11983 Rhode Island License Number: AAL-126 Texas Department of State Health Services License Number: 300440 Commonwealth of Virginia 3333000323 Washington State License Number: C989 West Virginia License Number: LT000566 Vermont License: AL166318
Revision Date: 11/30/2017
ROANOKE, VA 24019
800-242-4906 TOLL FREE
540-521-1008 MAIN
www.HandP.com
ENGINEERING • SURVEYING • PLANNING • ENVIRONMENTAL • GIS
123 Bruton Court Suite 100 Chesapeake, Virginia 23322
Attention: James Collins, PE Ph: 757-389-5518 / Email: coliins@avetechdg.com
Subject: Building 5 Asbestos Testing Services Upgrade Fire Alarm System, Project #658-19-105
Hurt & Proffitt, Inc. (H&P) was requested to conduct sampling for asbestos containing materials (ACM) that will be impacted by the work for the Fire Alarm System Upgrade Project. This survey was conducted in Building 5 at the Salem Veterans Affairs Medical Center in Salem, Virginia. The sampling was performed by H&P representatives Mr. Roy Wriston (Virginia Asbestos Inspector License number is 3303 003648) and Ms. Mary Beth Wriston (Virginia Asbestos Inspector License number is 3303 003466) on December 17-18, 2019. This letter and attachments represent H&P’s report for the above-referenced project.
1.0 Asbestos Survey Procedures and Findings
H&P was provided with construction drawings showing the general locations where work is planned noting the specific work scope in the respective areas. Based on our review of the drawings, sampling was performed to target suspect ACM in each work area based on the work task type. The targeted sampling was limited to surfaces where components will be mounted and excluded materials that could be affected by running of lines since their routing will be determined in the field by the installation
The survey included the collection and submittal of 26 individual samples of suspect asbestos containing materials (ACM) that were analyzed for a total of 37 layers. The sampling was limited to non-invasive means and was performed in accordance with state and federal regulations.
The suspect asbestos samples were submitted for analysis by EPA Method No. 600/R-93/116 and 600/M4-82-020 polarized light microscopy (PLM). All samples were analyzed by SanAir Technologies analysis within the State of Virginia. The sampling results are shown in the following table. Copies of the laboratory Asbestos Analysis Bulk Report and Chain of Custody forms are included as an attachment to this report
Table I –Building 5–Asbestos Sample Analysis Results
Sample # Sample Type Lab Description. Sample Location Results Condition
1217RW01-5
Plaster-wall Tan Non-Fibrous
Basement
None Detected
Fair
Skim Coat-wall White Non-
Fibrous None
Detected Fair
1217RW02-5 Wall coating White Non-
Fibrous Basement
None Detected
Fair
1217RW03-5
2x2 Dotted ceiling tile
White Fibrous Basement Hall at elevator None
Detected Fair
1217RW04-5
2x2 Fissured ceiling tile White Fibrous
Basement Hall at elevator
None Detected
Fair
1217RW05-5
2x2 Dotted Ceiling Tile
White Fibrous Basement Med student bedroom None
Detected Fair
1217RW06-5
Drywall-wall White Non-
Fibrous Basement
Women’s Clinic Rest Room/Wall
None Detected
Fair
Plaster-wall Cream Non-
Fibrous None
Detected Fair
Skim coat-wall White Non-
Fibrous None
Detected Fair
1217RW07-5
2x2 Dotted ceiling tile
White Fibrous Basement Room
1M None
Detected Fair
1217RW08-5
2x2 Fissured ceiling tile White Fibrous
Basement Hall by Room 10
None Detected
Fair
1217RW09-5
Drywall-wall White Non-
Fibrous Basement Hall by Break Room
None Detected
Fair
Plaster-wall Gray Non-
Fibrous None
Detected Fair
1217RW10-5
2x2 Fissured ceiling tile White Fibrous
Basement Break Room
None Detected
Fair
1217RW11-5 Wall White Non-
Fibrous PACT Exam Room
Rest Room None
Detected Fair
1217RW12-5
2x4 Fissured ceiling tile White Fibrous
1st Floor Elevator Lobby
None Detected
Fair
1217RW13-5 Wall White Non-
Fibrous 1st Floor Elevator
Lobby None
Detected Fair
1217RW14-5 Wall White Non-
Fibrous 1st Floor Women’s
Rest Room None
Detected Fair
1217RW15-5 Plaster-wall Gray Non-
Fibrous Rest Room By 2nd Floor Call Center
None
Sample # Sample Type Lab Description. Sample Location Results Condition
Skim coat-wall White Non-
Fibrous None
Detected Fair
1217RW16-5 Wall Gray Non-
Fibrous 2nd Floor Office
Vestibule None
Detected Fair
1217RW17-5
Plaster-wall Tan Non-Fibrous 2nd Floor Break
Room
None Detected
Fair
Skim coat-wall White Non-
Fibrous None
Detected Fair
1217RW18-5 Wall White Fibrous Column in 2nd Floor corridor
None Detected
Fair
1217RW19-5
2x2 Fissured Ceiling Tile
White Fibrous 2nd Floor Elevator
Lobby None
Detected Fair
1217RW20-5
Insulation-wall panel
Yellow Fibrous 1st Floor
Auditorium
None Detected
Fair
Wrap-wall panel
Blue Fibrous None
Detected Fair
1217RW21-5
Fiber Board-wall
Tan Fibrous
1st Floor Auditorium by
Window
None Detected
Fair
Mastic-wall Tan Fibrous None
Detected Fair
Joint Compound-wall
White Non- Fibrous
None Detected
Fair
1217RW22-5
Plaster-wall Tan Non-Fibrous 1st Floor Kitchen
None Detected
Fair
Skim coat-wall White Non-
Fibrous None
Detected Fair
1217RW23-5
Plaster-wall Tan Non-Fibrous 2nd Floor Storage
Room
None Detected
Fair
Skim coat-wall White Non-
Fibrous None
Detected Fair
1217RW24-5 Mortar-wall Tan Non-Fibrous 1st Floor Enclosed
Porch None
Detected Fair
1217RW25-5
Plaster-wall Tan Non-Fibrous 1st Floor By Stage
Exit Door
None Detected
Fair
Skim Coat-wall Red Non- Fibrous
None Detected
Fair
1217RW26-5
Plaster-wall Cream Non-
Fibrous 1st Floor Enclosed Porch
None Detected
Fair
Skim coat-wall White Non-
Fibrous None
Detected
Based on the results of sample analysis, asbestos containing materials were not identified in the areas and materials sampled during this survey.
2.1 Presumed Asbestos Containing Materials
During the conduct of this survey, sampling was limited to those materials which were within the areas designated by the client, which were safely accessible, and were able to be sampled without damaging systems or structures. Additionally, the facility and multiple rooms were occupied and in use at the time or our survey; which limited our ability to access all areas. As such, other materials not represented in negative for asbestos. Some components that were not accessible and/or could not be sampled include:
core then this material must be presumed to be asbestos containing and should be treated as such;
unless sampling and analysis is performed and confirms the absence of asbestos in the material.
Thermal systems insulation that may be present in wall cavities or above ceilings and; if the scope of work will disturb the material, then it must be presumed to be asbestos containing and should be
If work is performed that will impact suspect materials that have not been sampled, it is recommended that they be sampled by a Virginia licensed Asbestos Inspector prior to disturbance. We note that during renovation or demolition activities, it is not uncommon to reveal materials that were not accessible during
3.1 EPA/NESHAP Regulations for Asbestos Containing Materials
The U.S. Environmental Protection Agency promulgated the National Emission Standards for Hazardous Air Pollutants (NESHAP) [40 CFR Part 61], which addresses the application, removal, and disposal of asbestos-containing materials (ACM). Under NESHAP the following categories are defined for asbestos-containing materials:
Friable - When dry, can be crumbled, pulverized, or reduced to powder by hand pressure.
Non-friable - When dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure.
Category I Non-friable ACM - Packings, gaskets, resilient floor coverings, and asphalt roofing products containing more than 1% asbestos.
Category II Non-friable ACM – Any material, excluding Category I Non-friable ACM, which contains more than 1% asbestos.
Regulated Asbestos Containing Material (RACM) – One of the following:
1. Friable ACM
2. Category I Non-friable ACM that has become friable.
3. Category I Non-friable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading.
4. Category II Non-friable ACM that has a high probability of becoming, or has become, friable by the inspect the affected facility or part of the facility where the demolition or renovation activities will
3. RACM need not be removed if:
a) It is Category I non-friable ACM that is not in poor condition.
b) It is on a facility component that is encased in concrete or other similar material and is adequately wet whenever exposed.
c) It was not accessible for testing and was therefore not discovered until after demolition began and because of the demolition the material cannot be safely removed.
demolition due to the fact that disturbance can damage them, create potential exposure to workers and occupants and make them friable. This recommendation is made as a best practice to reduce potential exposure and limit liability.
3.2 OSHA
The Occupational Safety and Health Administration (OSHA) regulates employee exposure to asbestos under 29 CFR 1926.1101 and 29 CFR 1926.1001. Work associated with known or suspect asbestos these regulations in addition to the noted EPA regulations where applicable.
If the materials that have been identified as asbestos containing will be disturbed or are in poor condition, it is recommended that the asbestos be removed by an appropriately trained and licensed asbestos abatement contractor in accordance with Virginia, EPA and OSHA regulations.
9.0 Limitations
This report summarizes the results of our sample collection and analysis of the suspect ACM materials at the facility based on our understanding of the requested scope of work. The findings prepared by H&P are based upon our observations and the analytical analysis of the samples collected at the time of our field inspection. The services performed were provided in accordance with generally accepted environmental industry standard practices. No warranty, expressed or implied, is made. Our observations, conclusions and recommendations are based upon conditions readily visible at the site at the time of our visit, the results of testing and analysis and information provided to us by others.
Our conclusions and recommendations are based on the guidelines presented by the EPA, Commonwealth of Virginia and OSHA. Any conditions discovered which deviate from the data contained in this report should be presented to us for our evaluation. This report has been prepared for the exclusive use of the client/or their agents. This service was performed in accordance with generally accepted environmental practices. Our conclusions and recommendations are based, in part, upon information provided to us by others; we have not verified the completeness or accuracy of the information provided by others, unless otherwise noted.
During H&P’s non-invasive inspection, accessible areas were visually surveyed for the presence of ACM.
Areas reviewed were limited to those identified by the Client and that could be readily and safely accessed. Our conclusions and recommendations are based on the results of our testing and cannot be used to form a professional opinion of conditions in other areas beyond those from which the samples were collected. It is possible that inaccessible areas, such as behind walls or above ceilings, may not have been surveyed and therefore conditions in these areas are unknown.
During this study, suspect asbestos samples were submitted for analysis at an NVLAP-accredited laboratory via polarized light microscopy. As with any similar survey of this nature, actual conditions exist only at the precise locations from which samples were collected. Certain inferences are based on the results of this sampling and related testing to form a professional opinion of conditions in areas beyond those from which the samples were collected. It is also understood that this is a limited survey so that it is possible that concealed materials may be present that were not accessible to us. No other warranty, expressed or implied, is made.
H&P assumes no responsibility regarding response actions initiated as a result of our findings; nor liability for the duties and responsibilities of the Client or building owner with respect to compliance with applicable regulations. Compliance with regulations are the responsibility of the Client or building owner g.whitt@handp.com or Mary Beth Wriston at 540-588-0941 or via email at m.wriston@handp.com. We appreciate the opportunity to serve as your environmental consultant.
Roanoke Office Roanoke Office
SanAir ID#: 19064373
Project Name: Building 5
Report Date: 12/31/2019
Analysis Report prepared for
We at SanAir would like to thank you for the work you recently submitted. The 26 sample(s) were received on Thursday, December 19, 2019 via FedEx. The final report(s) is enclosed for the following sample(s): 1217RW01-5, 1217RW02-5, 1217RW03-5, 1217RW04-5, 1217RW05-5, 1217RW06-5, 1217RW07-5, 1217RW08-5, 1217RW09-5, 1217RW10-5, 1217RW11-5, 1217RW12-5, 1217RW13-5, 1217RW14-5, 1217RW15-5, 1217RW16-5, 1217RW17-5, 1217RW18-5, 1217RW19-5, 1217RW20-5, 1217RW21-5, 1217RW22-5, 1217RW23-5, 1217RW24-5, 1217RW25-5, 1217RW26-5.
These results only pertain to this job and should not be used in the interpretation of any other job. This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.
Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory
Final Report Includes:
- Cover Letter
- Analysis Pages
- Disclaimers and Additional Information
Sample conditions:
- 26 samples in Good condition.
1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com
20192002Project Number:
20192002P.O. Number:
Project Name: Building 5
12/17/2019 - 12/18/2019Collected Date:
12/19/2019 11:00:00 AMReceived Date:
12/31/2019 12:37:34 PM
19064373 SanAir ID Number
FINAL REPORT
Hurt & Proffitt, Inc.Name:
Address: 2524 Langhorne Road
Lynchburg, VA 24501
Analyst: Li, Elizabeth | Hogrefe, Sarah
Stereoscopic Components
SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers
1217RW01-5 / 19064373-001
Wall, Plaster
Tan Non-Fibrous
Homogeneous
100% Other None Detected
1217RW01-5 / 19064373-001
Wall, Skim Coat
White Non-Fibrous
Homogeneous
100% Other None Detected
1217RW02-5 / 19064373-002
Wall
White Non-Fibrous
Homogeneous
100% Other None Detected
1217RW03-5 / 19064373-003
Ceiling Tile
White Fibrous
Homogeneous
70% Cellulose 5% Glass
25% Other None Detected
1217RW04-5 / 19064373-004
Ceiling Tile
White Fibrous
Homogeneous
40% Cellulose 30% Glass
30% Other None Detected
1217RW05-5 / 19064373-005
Ceiling Tile
White Fibrous
Homogeneous
70% Cellulose 30% Other None Detected
1217RW06-5 / 19064373-006
Wall, Drywall
White Non-Fibrous
Homogeneous
5% Cellulose 95% Other None Detected
1217RW06-5 / 19064373-006
Wall, Plaster
Cream Non-Fibrous
Homogeneous
100% Other None Detected
1217RW06-5 / 19064373-006
Wall, Skim Coat
White Non-Fibrous
Homogeneous
100% Other None Detected
1217RW07-5 / 19064373-007
Ceiling Tile
White Fibrous
Homogeneous
40% Cellulose 30% Glass
30% Other None Detected
Analyst:
Analysis Date: 12/31/2019 Date: 12/31/2019
Approved Signatory:
20192002Project Number:
20192002P.O. Number:
Project Name: Building 5
12/17/2019 - 12/18/2019Collected Date:
12/19/2019 11:00:00 AMReceived Date:
12/31/2019 12:37:34 PM
19064373 SanAir ID Number
FINAL REPORT
Hurt & Proffitt, Inc.Name:
Address: 2524 Langhorne Road
Lynchburg, VA 24501
Stereoscopic Components
SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers
1217RW08-5 / 19064373-008
Ceiling Tile
White Fibrous
Homogeneous
40% Cellulose 30% Glass
30% Other None Detected
1217RW09-5 / 19064373-009
Wall, Drywall
White Non-Fibrous
Homogeneous
5% Cellulose 95% Other None Detected
1217RW09-5 / 19064373-009
Wall, Plaster
Gray Non-Fibrous
Homogeneous
100% Other None Detected
1217RW10-5 / 19064373-010
Ceiling Tile
White Fibrous
Homogeneous
50% Cellulose 20% Glass
30% Other None Detected
1217RW11-5 / 19064373-011
Wall
White Non-Fibrous
Homogeneous
100% Other None Detected
1217RW12-5 / 19064373-012
Ceiling Tile
White Fibrous
Homogeneous
40% Cellulose 30% Glass
30% Other None Detected
1217RW13-5 / 19064373-013
Wall
White Non-Fibrous
Homogeneous
100% Other None Detected
1217RW14-5 / 19064373-014
Wall
White Non-Fibrous
Homogeneous
100% Other None Detected
1217RW15-5 / 19064373-015
Wall, Plaster
Gray Non-Fibrous
Homogeneous
100% Other None Detected
1217RW15-5 / 19064373-015
Wall, Skim Coat
White Non-Fibrous
Homogeneous
100% Other None Detected
Analyst:
Analysis Date: 12/31/2019 Date: 12/31/2019
Approved Signatory:
1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com
20192002Project Number:
20192002P.O. Number:
Project Name: Building 5
12/17/2019 - 12/18/2019Collected Date:
12/19/2019 11:00:00 AMReceived Date:
12/31/2019 12:37:34 PM
19064373 SanAir ID Number
FINAL REPORT
Hurt & Proffitt, Inc.Name:
Address: 2524 Langhorne Road
Lynchburg, VA 24501
Stereoscopic Components
SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers
1217RW16-5 / 19064373-016
Wall
Gray Non-Fibrous
Homogeneous
100% Other None Detected
1217RW17-5 / 19064373-017
Wall, Plaster
Tan Non-Fibrous
Homogeneous
100% Other None Detected
1217RW17-5 / 19064373-017
Wall, Skim Coat
White Non-Fibrous
Homogeneous
100% Other None Detected
1217RW18-5 / 19064373-018
Wall
White Non-Fibrous
Homogeneous
100% Other None Detected
1217RW19-5 / 19064373-019
Ceiling Tile
White Fibrous
Homogeneous
40% Cellulose 30% Glass
30% Other None Detected
1217RW20-5 / 19064373-020
Wall, Insulation
Yellow Fibrous
Homogeneous
98% Glass 2% Other None Detected
1217RW20-5 / 19064373-020
Wall, Wrap
Blue Fibrous
Homogeneous
98% Synthetic 2% Other None Detected
1217RW21-5 / 19064373-021
Wall, Fiberboard
Tan Fibrous
Homogeneous
90% Cellulose 10% Other None Detected
1217RW21-5 / 19064373-021
Wall, Mastic
Tan Non-Fibrous
Homogeneous
100% Other None Detected
1217RW21-5 / 19064373-021
Wall, Joint Compound
White Non-Fibrous
Homogeneous
100% Other None Detected
Analyst:
Analysis Date: 12/31/2019 Date: 12/31/2019
Approved Signatory:
1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com
20192002Project Number:
20192002P.O. Number:
Project Name: Building 5
12/17/2019 - 12/18/2019Collected Date:
12/19/2019 11:00:00 AMReceived Date:
12/31/2019 12:37:34 PM
19064373 SanAir ID Number
FINAL REPORT
Hurt & Proffitt, Inc.Name:
Address: 2524 Langhorne Road
Lynchburg, VA 24501
Stereoscopic Components
SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers
1217RW22-5 / 19064373-022
Wall, Plaster
Tan Non-Fibrous
Homogeneous
100% Other None Detected
1217RW22-5 / 19064373-022
Wall, Skim Coat
White Non-Fibrous
Homogeneous
100% Other None Detected
1217RW23-5 / 19064373-023
Wall, Plaster
Tan Non-Fibrous
Homogeneous
100% Other None Detected
1217RW23-5 / 19064373-023
Wall, Skim Coat
White Non-Fibrous
Homogeneous
100% Other None Detected
1217RW24-5 / 19064373-024
Wall
Tan Non-Fibrous
Homogeneou…