36C24618R0838-002.pdf

PDF 1 MB Posted

Attached to
Project 659-18-202, Replace Roofs Bldg 2 Federal contract opportunity
Solicitation number
36C24618R0838
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 6

About this file

36C24618R0838 CONTRACT ATTACHMENT A - 659-18-202 Drawings.pdf

View the file

Other files for this federal contract opportunity

Other files attached to Project 659-18-202, Replace Roofs Bldg 2, newest first.
File Type Posted
36C24618R0838-0003001.pdf PDF
36C24618R0838-0003000.docx DOCX document
36C24618R0838-0002001.pdf PDF
36C24618R0838-0002000.docx DOCX document
36C24618R0838-0002002.pdf PDF
36C24618R0838-001.docx DOCX document
36C24618R0838-004.docx DOCX document
36C24618R0838-003.pdf PDF
36C24618R0838-005.pdf PDF
36C24618R0838-000.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1. Coordinate with sheet metal work to provide metal cap flashing for base flashing on curbs and walls and penetrations.

2. Use surface mounted type (NRCA manual) on existing walls.

3. Use umbrella type (NRCA manual) on pipes that are not open.

4. Do not terminate base flashing or membrane edge exposed on top of parapet walls or in reglets on horizontal or sloped wash surface. Terminate only under cap flashings or coping covers except gravel stops and for draw bands on pipe boots.

5. Use 203 mm (8 inch) minimum height for base flashing.

6. Do not use "pitch pocket" or "sealant pocket" in lieu of base flashings, liquid applied, and cap flashings.