36C24618Q9692-0001002.pdf

PDF 20 MB Posted

Attached to
Semi-Annual Asbesots Periodic Surveillance
Solicitation number
36C24618Q9692
Issued by

About this file

36C24618Q9692 0001 VA Asbestos 2018 7-3-18.pdf

View the file

Other files

File Type Posted
-14982.docx DOCX document
36C24618Q9692-0001003.docx DOCX document
36C24618Q9692-0001000.docx DOCX document
36C24618Q9692-0001001.pdf PDF
36C24618Q9692-002.pdf PDF
36C24618Q9692-001.docx DOCX document
36C24618Q9692-003.docx DOCX document
36C24618Q9692-000.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

THE SUSPECT MATERIALS SAMPLED AND REPRESENTED WITHIN

THESE INSPECTION DRAWINGS DO NOT NECESSARILY MEET THE

SAMPLING REQUIREMENTS OF A NESHAP INSPECTION.

BUILDING WING FLOOR SHEET NO.

DRAWING INDEX

ABC

ABC

ABC

ABC

ABC

ABC

ABC

ABC

ABC

ABC

ABC

ABC

ABC

D

D

D

D

D

D

E

E

E

E

E

E

F

F

F

F

SITE PLAN

BASEMENT

GROUND

FIRST

SECOND

THIRD

FOURTH

FIFTH

SIXTH

SEVENTH

EIGHTH

NINETH

TENTH

PENTHOUSE

GROUND

FIRST

SECOND

THIRD

FOURTH

FIFTH

BASEMENT

GROUND

FIRST

SECOND

THIRD

FOURTH,PENTHOUSE

GROUND

FIRST

SECOND

THIRD

BASEMENT,FIRST,SECOND

BASEMENT,FIRST

FIRST

FIRST

BASEMENT,FIRST, SECOND

FIRST, SECOND

GROUND

GROUND

FIRST

SECOND

THIRD

C-1

ABC-1

ABC-2

ABC-3

ABC-4

ABC-5

ABC-6

ABC-7

ABC-8

ABC-9

ABC-10

ABC-11

ABC-12

ABC-13

D-1

D-2

D-3

D-4

D-5

D-6

E-1

E-2

E-3

E-4

E-5

E-6

F-1

F-2

F-3

F-4

B3-1

B6-1

B7-1

B9-1

B14-1

B16-1

B18-1

B23-1

B23-2

B23-3

B23-4

FIRST

B5-1

FIRST

B8-1

SECOND

B8-2

FIRST

B24-1

FIRST

B29-1

FIRST B30-1

FIRST

B19-1

FIRST

SECOND

THIRD

FOURTH

B15-1

B15-2

B15-3

B15-4

B15-5

FIFTH

BOOTH

N

GROUND B26-1

- GROUND B33-1

ASBESTOS INSPECTION EXCLUDES

ROOFING AND EXTERIOR MATERIALS.

SAMPLING REQUIREMENTS OF A NESHAP INSPECTION.

BUILDING No. 1 A, B & C WINGS BASEMENT FLOOR

ASBESTOS-CONTAINING MATERIALS

NON-ASBESTOS-CONTAINING MATERIALS

LEGEND

SAMPLE IDENTIFICATION

40'0 20' 60'

SAMPLING REQUIREMENTS OF A NESHAP INSPECTION.

BUILDING No. 1 A, B & C WINGS GROUND FLOOR

ASBESTOS-CONTAINING MATERIALS

NON-ASBESTOS-CONTAINING MATERIALS

LEGEND

SAMPLING REQUIREMENTS OF A NESHAP INSPECTION.

BUILDING No. 1 A, B & C WINGS FIRST FLOOR

SAMPLE IDENTIFICATION

LEGEND

NON-ASBESTOS-CONTAINING MATERIALS

ASBESTOS-CONTAINING MATERIALS

SAMPLING REQUIREMENTS OF A NESHAP INSPECTION.

BUILDING No. 1 A, B & C WINGS/INTERSTITIAL AREA SECOND FLOOR

SAMPLE IDENTIFICATION

LEGEND

NON-ASBESTOS-CONTAINING MATERIALS

SAMPLING REQUIREMENTS OF A NESHAP INSPECTION.

BUILDING No. 1 A, B & C WINGS/INTENSIVE CARE UNIT THIRD FLOOR

SAMPLE IDENTIFICATION

ASBESTOS-CONTAINING MATERIALS

NON-ASBESTOS-CONTAINING MATERIALS

LEGEND

SAMPLING REQUIREMENTS OF A NESHAP INSPECTION.

SAMPLING REQUIREMENTS OF A NESHAP INSPECTION.

GRAPHIC SCALE - IN FEET

20' 40'10'20'

BUILDING No. 1 A, B, & C WINGS/ICU FIFTH FLOOR

SAMPLE IDENTIFICATION

N

O

R

T

H

LEGEND

NON-ASBESTOS-CONTAINING MATERIALS

SAMPLING REQUIREMENTS OF A NESHAP INSPECTION.

ASBESTOS-CONTAINING MATERIALS

NON-ASBESTOS-CONTAINING MATERIALS

SAMPLE IDENTIFICATION

LEGEND

BUILDING No. 1 A, B & C-WINGS EIGHTH FLOOR

SAMPLING REQUIREMENTS OF A NESHAP INSPECTION.

BUILDING No. 1 A, B & C-WINGS NINTH FLOOR SAMPLE IDENTIFICATION

LEGEND

NON-ASBESTOS-CONTAINING MATERIALS

SAMPLING REQUIREMENTS OF A NESHAP INSPECTION.

40'0 20' 60'

SAMPLE IDENTIFICATION

LEGEND

NON-ASBESTOS-CONTAINING MATERIALS

ASBESTOS-CONTAINING MATERIALS

N

O

R

T

H

BUILDING No. 1 A, B & C-WINGS TENTH FLOOR

20'0 10' 30'

E1007

E1015

E1019 E1018

E1017

E1016

E1011

E1010

E1013

E

E1014

E1009

E1008

E1003

E1005

E1006

E1001E1004

E1002

THE SUSPECT MATERIALS SAMPLED AND REPRESENTED WITHIN

THESE INSPECTION DRAWINGS DO NOT NECESSARILY MEET THE

SAMPLING REQUIREMENTS OF A NESHAP INSPECTION.

20'0 10' 30'

N

O

R

T

F

F1471

F1472 F1473

F1474 F1475 F1477 F1478

F1480

F1445

F1446

F1447

F1448

F1449

F1450

F1451

F1470

F1469

F1468

F1467

F1466

F1465

F

F1464

F1463

F1453

F1461

F1460

F

F1459

F

F1455

F1456

F1457

TOILET

F1479

BREAK RMCONFERENCE RM

CLEAN UTILITY

EQUIPMENT STORAGE

OFFICEOFFICE

OFFICE

OFFICE

OFFICE

EXAM

EXAM

EXAM

EXAM

EXAM

EXAM

EXAM

EXAM

EXAM

EXAM

EXAM

EXAM EXAM

EXAM EXAM

EXAM

EXAM

EXAM

EXAM

EXAMEXAM

EXAM

EXAM

NURSE

STATION

KITCHEN TOILET

TOILET

WORKROOM

V E

S T

I B

U L E

SOILED

UTILITY

ER

ER

ER

ER

DECON

SHOWER

VESTIBULE

F1405

TOILET

F1406

TOILET

CONTROL

THE SUSPECT MATERIALS SAMPLED AND REPRESENTED WITHIN

THESE INSPECTION DRAWINGS DO NOT NECESSARILY MEET THE

10'0 5' 15'

SAMPLING REQUIREMENTS OF A NESHAP INSPECTION.

N

O

R

T

SAMPLING REQUIREMENTS OF A NESHAP INSPECTION.

NON-ASBESTOS-CONTAINING MATERIALS

File details come from the government source that posted it.