This is a Sources Sought Notice (Request for Information) issued by the Department of Veterans Affairs Veterans Health Administration, Network Contracting Office 5, for market research purposes only. The VA is seeking information from capable firms regarding the procurement of a Digital Polymerase Chain Reaction (dPCR) System and related components for the Baltimore VA Medical Center. The solicitation number is 36C24526Q0235, with responses due by 12:00 PM EST on January 30th, 2026, submitted via email to Contract Specialist James Ferro at james.ferro@va.gov. The contracting office is located in Martinsburg, WV 25405.
The specific items to be procured include one QS ABS Q dPCR System (Part# A52864), one Primer Express 1-User License (Part# 4363991), one QS ABS Q MAP16 Plate Kit (Part# A52865), one Absolute Q dPCR Starter Kit (Part# A52732), one WiFi Dongle Kit (Part# A26774), and one SmartStart QStudioAbsQ license (Part# A52632). The system must meet minimum specifications including setup in under 10 minutes, completion of 40 cycles of digital PCR in under 90 minutes, detection sensitivity down to 0.1% mutant allele frequency, and utilization of over 95% of loaded samples. The suggested NAICS code is 339112 (Surgical and Medical Instrument Manufacturing) and PSC is 6515 (Medical and Surgical Instruments, Equipment, and Supplies). While SDVOSB and VOSB firms are preferred, all capable firms are welcome to respond. Respondents must provide company information, socioeconomic status, manufacturer/distributor details, current government contracts, service capability for VA locations, and estimated rates. The VA assumes no responsibility for costs incurred in preparing responses.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SUBJECT*
Digital Polymerase Chain Reaction (dPCR) System
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 25405 |
| SOLICITATION NUMBER* |
| 36C24526Q0235 |
| RESPONSE DATE/TIME/ZONE |
| 02-12-2026 12:00 PM EASTERN TIME, NEW YORK, USA |
| ARCHIVE |
| 15 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| 6515 |
| NAICS CODE* |
| 339112 |
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
Martinsburg VA Medical Center
510 Butler Avenue, Building 306A Martinsburg WV 25405
POINT OF CONTACT*
Contract Specialist James Ferro james.ferro@va.gov 202-745-8000
PLACE OF PERFORMANCE
| ADDRESS |
| Department of Veterans Affairs |
Baltimore VA Medical Center
10 North Greene Street
Baltimore MD
| POSTAL CODE |
| 21201 |
| COUNTRY |
| USA |
ADDITIONAL INFORMATION
| AGENCY’S URL |
| https://vaww.washingtondc.va.gov/ |
| URL DESCRIPTION |
| Washington DC VA Homepage |
AGENCY CONTACT’S EMAIL ADDRESS
EMAIL DESCRIPTION
Sources Sought Notice Sources Sought Notice
DESCRIPTION
| *= Required Field |
| Sources Sought Notice |
Sources Sought Notice
DESCRIPTION
This is not a solicitation but rather a Request for Information (RFI/Sources Sought) for market research purposes only. Department of Veterans Affairs, Veterans Health Administration, Network Contracting Office 5, is issuing this Sources Sought in order to identify capable firms and obtain information for planning purposes only.
Responses must be submitted by 12:00 PM EST, January 30th, 2026. Submit responses to this Sources Sought via email to james.ferro@va.gov All SDVOSB and VOSB firms that respond shall include proof of SBA certification via https://veterans.certify.sba.gov/All small business firms that respond shall include proof of small business status via their Representations and Certifications in accordance with (FAR 4.1102 Policy). While SDVOSB/VOSB firms are preferred, all capable firms are welcome to respond to this Sources Sought. All respondents to this Sources Sought shall include as part of their response answers to the below questions and provide any additional pertinent information that supports the answers. If there are any ambiguities in this Sources Sought, please identify them in your response.
The results of this market research will assist in the development of (1) the requirement, and (2) the acquisition strategy (e.g., socioeconomic set-aside, full and open competition, etc.). VA assumes no responsibility for any costs incurred associated with the preparation of responses.
| Suggested NAICS: | 339112 – Surgical and Medical Instrument Manufacturing |
| Suggested PSC: | 6515 – Medical and Surgical Instruments, Equipment, and Supplies |
Open to suggestions from the market as to a more proper NAICS and/or PSC, as well as any potential GSA/FSS Schedule SIN categories.
Items to be Procured:
| Manufacturer Part # |
| Item Description |
| Item Quantity |
| A52864 |
| QS ABS Q DPCR SYSTEM, DKTP |
| 1 |
| 4363991 |
| PRIMER EXPRESS 1-USER |
LICENSE EACH
| A52865 |
| QS ABS Q MAP16 PLATE KIT |
| 1 |
| A52732 |
| ABSOLUTE Q DPCR STARTER KIT |
| 1 |
| A26774 |
| KIT,802.11AC/B/G/N WIFI DONGLE |
EACH
| A52632 |
| SMARTSTART, QSTUDIOABSQ, CS |
EA
Statement of Work:
4. Scope. Minimum specifications that were identified:
· Single instrument set up requiring under 10 minutes of hand time with samples to perform absolute and accurate quantification without the need for standard curves or the use of sample replicates.
· Ability to combine amplification and detection in a single reaction to eliminate post-PCR manipulations.
· Complete 40 cycles of digital PCR using a fluorogenic 5´ nuclease assay in a digital PCR plate in under 90 minutes.
· Ability to detect down to 0.1% mutant allele frequency with a background of at least 10,000 copies of wild type target.
· Ability to detect down to 0.5 template copies/µL with 95% confidence relative to a no-template control
· Utilizes >95% of a loaded sample across >99% of available microchambers.
· Sample utilization exceeds 95%.
Salient Characteristics:
| Optical channels |
| 5 (fixed configuration) |
| Illumination |
| Red, blue, green, high powered LED |
| Multiplexing |
| 4 targets (5 optical channels, ROX dye used for reference) |
| Dynamic range |
| 5 orders of magnitude |
| Sensitivity |
| 1-100,000 copies |
| Precision |
| Plus/minus 10% |
| Sample throughput |
| Up to 16 samples per run |
Arrays can be run in 4 on a single plate
| Microchambers per reaction |
| 20,480 |
| Percentage of sample analyzed |
| 95% |
| Overall Dimensions |
| 24.5 inches long x 23.5 inches wide x 21.2 inches high |
| Weight |
| 132 pounds |
| Connections |
| Power, USB 3.0 (to dedicated PC) |
| Cooling Mode |
| Forced convection |
| Power input |
| 100-240 VAC, 50-60 Hz |
| Power rating |
| 1,200-1,600 W |
| Rated current |
| 12 A (110 V), 8.5 A (230 V) |
| Maximum noise level |
| 70 dB |
Compatible dyes blue, green, yellow, red, deep red
| Color |
| Excitation filter nm |
| Emission filter nm |
| Examples of compatible dyes |
| 1 |
| Blue |
| 466 |
| 520 |
| FAM |
| 2 |
| Green |
| 514 |
| 560 |
| HEX, VIC |
| 3 |
| Yellow |
| 549 |
| 589 |
| ABY |
| 4 |
| Red |
| 589 |
| 625 |
| ROX |
| 5 |
| Deep red |
| 630 |
| 684 |
| JUN, Cy5 |
If you are interested, please e-mail the following information:
1. Company Name:
0. UEI Number:
0. Cage Code:
0. Dun & Bradstreet Number:
1. Person of Contact (including telephone number and email address).
1. Socio-economic status (SDVOSB, VOSB, Woman-Owned, Other… etc.).
1. Are you a distributor or a manufacturer?
3. If you are an authorized distributor, please provide confirmation on Company Letter Head.
3. If you are a distributor, who is the manufacturer?
3. Where is the manufacturer located in the world?
1. Do you currently hold a government contract?
4. Contract Number?
4. Type of contract?
4. Are these particular quoted items under contract?
4. With whom (GSA, SEWP, etc…)?
3. If GSA what Schedule and SIN?
1. Can your company provide the service for the listed Department of Veterans Affairs locations?
1.
Page 1 of Page 1 of Page 1 of Page 1 of Page 1 of
Page 1 of Page 1 of Page 1 of Page 1 of Page 1 of Page 1 of Page 1 of Page 1 of Page 1 of Page 1 of
1. Does your firm utilize the suggested NAICS and PSC per this Sources Sought Notice? If not, please suggest a more appropriate NAICS and/or PSC and explain why it’s more appropriate?”
1. How do you invoice for this service, including rates?
1. What Certifications, State and/or Federal, if any must you have to perform this service?
1. Please list all of your concerns, questions and ambiguities below. Questions will not be addressed directly but will be used by the Government in the event that this Sources Sought would move forward to solicitation.
1. Please provide estimated rates if possible.
Page 1 of Page 1 of Page 1 of Page 1 of Page 1 of