About this file

This sources sought notice requests information from contractors for the refurbishment of a 2004 Pierce fire truck for the Martinsburg VA Medical Center. Key details include a request for complete refurbishment and upgrade of all applicable equipment on the truck in accordance with NFPA 1912 standards, with specific tasks listed such as inspection and replacement of parts for the engine, transmission, braking and electrical systems, as well as body work and replacement of ladders, lights, pumps, valves and other components. Respondents are asked to provide company information and details on pricing, scheduling, warranties and confirmation of whether all work will be done in-house or subcontracted. The response deadline is July 17, 2023. The notice indicates this request for information will not directly result in an award but will be used to determine market availability and procurement strategy.

View the file

Other files

File Type Posted
NFPA 1912 FIRETRUCK REFURBISHMENT PACKAGE.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sources Sought Notice

Sources Sought Notice

SOLICATION #: 36C24523Q0726

SUBJECT*
REQUEST FOR INFORMATION ONLY | FIRE TRUCK REFURBISHMENT | MARTINSBURG VA MEDICAL CENTER

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
21201
SOLICITATION NUMBER*
36C24523Q0726
RESPONSE DATE/TIME/ZONE
07-17-2023 1:00 PM EASTERN TIME, NEW YORK, USA
ARCHIVE
60 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N

SET-ASIDE

PRODUCT SERVICE CODE*
J012
NAICS CODE*
336120
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

MARTINSBURG VAMC

500 BUTLER AVENUE

MARTINSBURG WV 25405

POINT OF CONTACT*

CONTRACTING OFFICER

AMY.WALTER1@VA.GOV

PLACE OF PERFORMANCE

ADDRESS
Department of Veterans Affairs

MARTINSBURG VAMC

500 BUTLER AVENUE

MARTINSBURG WV

POSTAL CODE
25405

COUNTRY

ADDITIONAL INFORMATION

AGENCY’S URL

URL DESCRIPTION

AGENCY CONTACT’S EMAIL ADDRESS

EMAIL DESCRIPTION

DESCRIPTION

REQUEST FOR INFORMATION

STATEMENT OF WORK (SOW)

PROJECT NAME: Firefighting Apparatus Refurbishment Background: To remain in compliance with NFPA 1901(2016) we need to refurbish our 2004 Pierce Pumper Apparatus.

Scope: A complete refurbish and upgrade in accordance with NFPA 1912 (2016) of all applicable equipment on a 2004 Pierce Pumper Apparatus with a 1,500 GPM Pump Capacity with a 1,000-gallon booster tank. A fire apparatus is an emergency vehicle that must be relied on to transport fire fighters safely to and from an incident and to operate reliably and properly to support the mission of the fire department. A piece of fire apparatus that breaks down at any time during an emergency operation not only compromises the success of the operations but might jeopardize the safety of the fire fighters relying on that apparatus to support their role in the operations. An old, worn out, or poorly maintained fire apparatus has no role in providing emergency services to a community.

Specific Tasks.

Contractor will honor the provided bid price for 120 days. Contractor will provide an approval drawing for all body, decals and striping and paint modifications. A parts, service and operations manuals shall be provided.

Contractor will complete a thorough inspection of the following items and will replace and/or repair as needed.

Engine, Transmission, Traction Control System, Anti-lock Braking System, Drive Shafts, Front Axle, Rear Axle, Braking System, Auxiliary Braking System, Parking Brakes, Suspension, Wheels, Tires, Cooling System, Engine Speed Control, Lubrication System, Air Intake System, Fuel System, Fuel Tank, Exhaust System, Steering, Tow Hooks/Eyes, Traffic Horn, Air Horns, Load Manager, Low Voltage Alarm, Entire Body to include repairing any damage, Door Stays, Compartment Floors, Pump Enclosures, Steps/ Walkways/ Handrails/ Hose Beds/ Equipment Storage/ Suction Hose Storage/ Powered Equipment Racks, SCBA Storage, SCBA Bottle Storage, Receivers and Anchors, Water Tank, Baffles.

Contractor will replace all applicable suction hoses and the 24 ft extension ladder, 14 ft roof ladder and 10 ft attic ladder, Alternator, Alternator Wiring, Batteries, Battery Wiring, Starter, Starter Wiring, Chassis Wiring Harness, Body Wiring Harness, Warning Lights (LED), Scene Lighting (LED), Head Lights (LED), Stop, Taillights (LED), Turn Signal Lights (LED), Sirens, Hazard Light (LED), Pump Panel Lighting (LED), Backup Alarm, Battery Charger/Conditioner, Personnel Enclosure, Seat Belts, Seats, Cab Tilt, Instrumentation, Intercom System, Heating, Air Conditioning, Steps or Handrails.

Steering Wheel/Column, Doorlatches/Locks, Hose Bed Covers, Pump Panels, Pump, Valves, Valve Controls, Intake Relief System, Pressure Control System, Priming System, Gauges, Flowmeters, Tank Level Gauge, Tank to Pump Line, Tank to Fill Line, Direct Tank Fill, Tank Fill/Vent, Foam System, Line Voltage System, Power Source, Instrumentation, Panelboard, Transfer Switch, Wiring, Receptacles, Cord Reels.

Contractor will upgrade or replace the following items:

Automatic Tire Chains, Electronic Siren (Power call), Ground Lighting (LED), Hose Bed Lighting (LED), Surface Lighting (LED), Interior Lighting (LED), Compartment Lighting (LED), (2) Mars Lights (LED), (1) Roto Ray Warning Device (LED), Jersey Type Cab Doors, Mirrors, Lap Type Compartment Doors, Computer Equipment Provisions, Contractor shall install a 2.5-inch discharge in the hose bed (Location to be determined in drawing), Paint, Striping, and Decals will be replaced with details provided by the Veterans Affairs Fire Dept Fire Chief.

A warranty will be provided for a yet unspecified period. The refurbished apparatus is to be inspected by employees of the Martinsburg VAMC Fire Department to ensure completion and that all specifications are adhered to and in proper working order before accepted.

6. Risk Control: There are no risk factors we are concerned with.

We do not have special safety issues. Project will not be completed at our facility.

7. Place of Performance: The place of performance will be at the selected contractor’s facility.

8. Period of Performance: Required start date for the service: January 1st, 2024

9. Delivery Schedule: TBD

10. Contract Administration Data: The Contracting Officer is the only person authorized to approve changes or modify any of the requirements of this contract. The Contractor shall communicate with the Contracting Officer on all matters pertaining to contract administration. Only the Contracting Officer is authorized to make commitments or issue changes that shall affect the price, quantity, or quality of performance of this contract.

In the event the Contractor effects any such change at the direction of any person other than the Contracting Officer without authority, no adjustment shall be made in the contract price to cover any increase in costs incurred as a result thereof.

11. Hours of Work: Work being performed at Contractor’s facility.

**Required** ALL RESPONDENTS SHALL INCLUDE and SUBMIT THE FOLLOWING:

Responses to this Request for Information (RFI) shall include company name, address, point of contact, phone number, point of contact e-mail, DUNS Number, Cage Code, size of business pursuant to North American Industrial Classification System (NAICS) 336120, (size standard of 1,500 EMPLOYEES, per SBA Table of Small Business Size Standards JANUARY 1, 2022) AND whether your company is a special socio-economic status (i.e., SDVOSB, VOSB, Small Business, HUBZone, etc.)

Respondents shall answer the following questions:

1. Size, status, and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Small Business (SB), Large Business, etc.

2. Is your company considered small under the NAICS code identified under this RFI? (Size standard of = or < $30M, per SBA Table of Small Business Size Standards August 19, 2019)

3. Is your company a large business?

4. Does your company have an FSS contract with GSA or the VA NAC or a GWAC contract holder with any other federal agency? If so, please provide the contract number.

5. If your company holds a FSS GSA/VA NAC contract other federal GWAC contract holder, are the services requested available on your schedule/contract?

6. General pricing of your products is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.

Information provided by potential sources will be utilized by the Government to determine market availability and procurement strategy. **A contract award will not result from this RFI Notice.

Vendors who can meet the requirements listed above shall provide the following information:

• Business Name

• Business Address

• Business Point of Contact, including phone number and email address

• Business size

• Business Socioeconomic Status

• Federal Supply Scheduling (FSS) number, if the items required by the Government are available for purchase on an FSS contract.

• Any other pertinent capability information that relates to the above stated requirement.

7. ***WILL YOUR COMPANY BE DOING ALL OF THE WORK? IF NOT, WILL YOUR COMPANY BE SUB-CONTRACTING OUT THE WORK?***MUST ANSWER***

SUBMIT ALL Questions FOR INFORMATION TO AMY.WALTER1@VA.GOV NO LATER THAN Monday, JULY 17, 2023 1:00 PM EST.

See attached document: NFPA 1912 FIRETRUCK REFURBISHMENT PACKAGE.

*= Required Field
Sources Sought Notice

Sources Sought Notice

File details come from the government source that posted it. Updated .