36C24521Q0602_1.docx

DOCX document 14 KB Posted

Attached to
6630--VIRTUO A-Clinical Blood Culture Analyzer including the MYLA software.
Solicitation number
36C24521Q0602
Issued by

View the file

Other files

File Type Posted
S02 RFQ 36C24521Q0602.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Combined Synopsis/Solicitation Notice Combined Synopsis/Solicitation Notice

SUBJECT*
VIRTUO A-Clinical Blood Culture Analyzer including the MYLA software.

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
21902
SOLICITATION NUMBER*
36C24521Q0602
RESPONSE DATE/TIME/ZONE
07-09-2021 10AM EASTERN TIME, NEW YORK, USA
ARCHIVE
10 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N

SET-ASIDE

PRODUCT SERVICE CODE*
6630
NAICS CODE*
334516
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

VA Maryland Health Care System Theresa Thomas, Contract Specialist P.O. Box 1000, Bldg. 101B Perry Point MD 21902

POINT OF CONTACT*

Theresa Thomas Contract Specialist theresa.thomas7@va.gov

PLACE OF PERFORMANCE

ADDRESS
Martinsburg VA Medical Center

510 Butler Ave

Martinsburg, WV. 25405

POSTAL CODE

COUNTRY
USA

ADDITIONAL INFORMATION

AGENCY’S URL

URL DESCRIPTION

AGENCY CONTACT’S EMAIL ADDRESS

EMAIL DESCRIPTION

DESCRIPTION

Blood Culture Analyzer

The Martinsburg VAMC has a requirement for a blood culture analyzer for detection of positive blood cultures. The analyzer procurement shall include Myla software in order to provide the facility’s existing Vitek 2 Compact 60 microbiology analyzer and the new blood culture analyzer with a supported data management platform to maximize workflow. The requirement is for a fully automated blood culture analyzer that can automatically load and unload bottles. The unit shall have blood volume level detection and not be a human/manual process. The unit shall have notification alarms for improperly filled bottles, including remote notification. The equipment shall provide scan error alerts instantly. The analyzer shall perform imaging of the bottle to provide instant recognition of barcode labels; it shall read the barcode for lot authentication and expiration date. The equipment shall be able to utilize the Lab’s existing identification and susceptibility testing which utilized Biomerieux culture bottles, identification cards, and susceptibility cards. The analyzer shall have a VA Enterprise Risk Analysis completed for network connection.

See attached document: S02 RFQ 36C24521Q0602.

*= Required Field
Combined Synopsis/Solicitation Notice

Combined Synopsis/Solicitation Notice

File details come from the government source that posted it. Updated .