Contract Opportunity Amendment to a Previous Combined Solicitation

PRODUCT SERVICE CODE

SUBJECT

CONTRACTING OFFICE'S

ZIP-CODE

SOLICITATION NUMBER

BASE NOTICE TYPE

RESPONSE DATE/TIME/ZONE

ARCHIVE

DAYS AFTER THE RESPONSE DATE

RECOVERY ACT FUNDS

SET-ASIDE

NAICS CODE

CONTRACTING OFFICE

ADDRESS

POINT OF CONTACT

(POC Information Automatically Filled from User Profile Unless Entered)

DESCRIPTION

See Attachment

AGENCY'S URL

URL DESCRIPTION

AGENCY CONTACT'S EMAIL

ADDRESS

EMAIL DESCRIPTION

ADDRESS

POSTAL CODE

COUNTRY

ADDITIONAL INFORMATION

GENERAL INFORMATION

PLACE OF PERFORMANCE

* = Required Field Contract Opportunity Amendment to a Previous Combined Solicitation J079 Hobart Dishwasher Repair & Water Softener Replacement 21201 36C24521Q0479 05-24-2021

11:00AM

EASTERN TIME, NEW YORK, USA

N 811310 Department of Veterans Affairs Martinsburg VA Medical Center 510 Butler Ave.

Martinsburg, WV 25405 Contracting Officer Robert Tyler Hallock robert.hallock@va.gov 304-263-0811 * 3222 Department of Veterans Affairs Washington D.C. VA Medical Center 50 Irving St. NW Washington

DC

20422

US

robert.hallock@va.gov Contracting Officer See attached document: S02 - Dishwasher Repair_Solicitation.

Scope: The contract awarded by this solicitation shall provide all labor, equipment and/or parts to perform needed repairs or replacements to return to the dietary kitchen dishwasher to the intended optimal operation functionality. This scope is based on an assessment of the dishwasher by a certified technician representative with Hobart®. The contractor will need to replace floats, steam solenoids, conveyor rollers and bearings and rods—part of the water feed and travelling system to move the dish through the equipment. Other components such as the pump/motors in the processing wells along with their motor starters were found to be damaged to the point of inoperability or failing not allowing the water to be dispersed into the wells. Control starters have been damaged from repetitive resetting. Equipment repairs should be performed by an authorized Hobart service technician familiar with the operation and design of the equipment to ensure repairs are ultimately safe and performs to the listed safety and performance standards.