About this file

36C24520Q0187 36C24520Q0187.docx

View the file

Other files

File Type Posted
36C24520Q0187-001.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Contract Opportunity Special Notice

CLASSIFICATION CODE

SUBJECT

CONTRACTING OFFICE'S

ZIP-CODE

SOLICITATION NUMBER

ARCHIVE

DAYS AFTER THE RESPONSE DATE

RECOVERY ACT FUNDS

NAICS CODE

CONTRACTING OFFICE

ADDRESS

POINT OF CONTACT

(POC Information Automatically Filled from User Profile Unless Entered)

DESCRIPTION

See Attachment

AGENCY'S URL

URL DESCRIPTION

AGENCY CONTACT'S EMAIL

ADDRESS

EMAIL DESCRIPTION

GENERAL INFORMATION

ADDITIONAL INFORMATION

* = Required Field Contract Opportunity Special Notice J099

NOTICE OF INTENT TO SOLE SOURCE THERMOFISHER ION TORRENT

SEQUENCING EQUIPMENT MAINTENANCE SERVICES TO:

LIFE TECHNOLOGIES CORPORATION; CAGE: 1F3R7

EDA: 2/1/2020

26301-4199 36C24520Q0187 N 811219 Department of Veterans Affairs Network Contracting Office 5 (NCO-5) Contracting Office (90C) 513 Rosebud Plaza Clarksburg WV 26301 Darren G. Morris - Contracting Officer darren.morris@va.gov 304-623-3461 ext. 4106 https://www.va.gov/health/ Department of Veterans Affairs - Veterans Health Admin.

darren.morris@va.gov Darren G. Morris - Contracting Officer

STATEMENT OF WORK

SCOPE OF WORK:

The Contractor shall provide all labor, personnel, equipment, tools, materials, parts, supervision and other items and services necessary to perform software service and maintenance to support the Thermo Fisher Scientific ION Reporter Server System, Ion Chef SVC, and the Ion S5 plus sequencer at the Washington DC Veterans Affairs Medical Center, 50 Irving Street NW, Washington, DC 20422. All work completed by the Contractor shall be performed by a certified Thermo-Fisher technician and/or engineer.

The contractor shall provide parts, labor and travel for remedial repair. Planned maintenance visits are included in the service agreement for the two devices. The planned maintenance is to occur once per year for each device. Technical support can be reached by priority telephone and email access. Also, remote monitoring and diagnostic service is available and allows for notification of instrument failures or errors.

1. EQUIPMENT:

The contractor shall provide all tools and equipment necessary to properly and safely perform the services set forth within this statement of work. This shall include, but is not limited, to all Personal Protective Equipment (PPE) which may be required for the work to be completed in a safe manner.

2. AREAS TO BE SERVICED:

Washington DC VAMC
50 Irving Street NW
Washington, DC 20422

2. PERIOD OF PERFORMANCE:

2/1/2020 – 1/31/2021, with 4 subsequent option years.

3. TASK FREQUENCY AND INSTRUCTIONS:

The contractor has a guaranteed priority response time of two business days after a service call is received in Zone 1 or Zone 2. If the contractor fails to arrive within two business days, the company will provide the customer a service plan renewal credit in an amount equivalent to one day’s pro-rated charge for each day the contractors response is late. The contractor has a targeted response time of three days for remedial repairs outside of Zone 1 or Zone 2. A service call must be received by the contractor’s service center by 2:00 pm local time for priority response time service.

Planned maintenance visits are budgeted for an annual visit for each of the two medical devices being supported by the service agreement. The contractor is able to perform more than one annual planned maintenance visit during the contract period, at their discretion, at no additional cost. If the customer requires an additional planned maintenance visit, the customer will be charged for the visit.

Contractor shall submit all removable media to be used on a VA system to Biomedical Engineering for scanning with anti-virus software prior to use on the system. In the case of equipment turn-in, exchange, repair or replacement hard drives used by the VA shall be removed from the equipment and remain in possession of VA this includes loaned or rented equipment.

(End SOW) See attached document: P03 - SingleSourceJustification_MPT-SAT (1) TF ION Torrent Services .