36C24518B0027-00001001.pdf

PDF 9 MB Posted

Attached to
Renovate 305 for Fiscal Proj 613-15-128
Solicitation number
36C24518B0027
Issued by

About this file

36C24518B0027 00001 Architectural1.pdf

View the file

Other files

File Type Posted
36C24518B0027-00003001.pdf PDF
36C24518B0027-00003000.docx DOCX document
36C24518B0027-00002000.docx DOCX document
36C24518B0027-00002001.pdf PDF
36C24518B0027-00001000.docx DOCX document
36C24518B0027-007.zip ZIP file
36C24518B0027-003.pdf PDF
36C24518B0027-004.pdf PDF
36C24518B0027-005.pdf PDF
36C24518B0027-006.zip ZIP file
36C24518B0027-002.docx DOCX document
36C24518B0027-001.docx DOCX document
Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

325 MIGRATION LN., GERRADSTOWN, WV 25420

304-267-2120

PLLC

GROVE & DALL’OLIO

A R C H I T E C T S

ROOM DOOR OPENS INTO

407B-14

Room name

SHEET NUMBER

SHEET NUMBER

DOOR NUMBER

DRAWING NUMBER

A3.1

DRAWING NUMBER

A3.1

A

A2.2

RENOVATION OF BUILDING 305 A&B,

MARTINSBURG VA MEDICAL CENTER

MARTINSBURG, WV

COMPACTED

GRAVEL FILL

CONCRETE

BRICK MASONRY

CERAMIC TILE

MATERIALS LEGEND

UNDISTURBED SOIL ARCHITECTURAL

GI-001

AD-101

AD-102

AD-103

AE-130

AS-101

AS-102

AE-201

AE-202

AS-510

AE-601

AE-602

AE-901

AE-902

STRUCTURAL

S0.1 S0.2 S1.1 S1.2 S1.3 S2.1 S3.1 S3.2 S3.3

MECHANICAL / ELECTRICAL / PLUMBING

MH-1

MH-2

MH-3

MH-4

MH-5

PL-1

PL-2

PL-3

PL-4

PL-5

EL-1

EP-1

EP-2

ET-1

FA-1

COVER SHEET

BASEMENT DEMOLITION NOTES

GROUND FLOOR DEMOLITION PLAN

ATTIC DEMOLITION NOTES

ROOF/SITE PLAN

GROUND FLOOR PLAN - 305A

GROUND FLOOR PLAN - 305B

EXTERIOR ELEVATIONS

BUILDING SECTIONS

REFLECTED CEILING PLAN

INTERIOR ELEVATIONS

INTERIOR ELEVATIONS

DOOR, WINDOW, & FINISH SCHEDULES & PARTITION TYPES

SKYLIGHT TUBES & WINDOW DETAILS

STRUCTURAL NOTES

STRUCTURAL NOTES & SCHEDULES

FOUNDATION PLANS

FIRST FLOOR FRAMING PLANS

ROOF FRAMING PLANS

FOUNDATION DETAILS

LIGHT GAUGE DETAILS

FRAMING DETAILS

FRAMING DETAILS

MECHANICAL HVAC SCOPE, SCHEDULE, & DETAILS

MECHANICAL HVAC FLOOR PLAN

MECHANICAL SCHEDULES

MECHANICAL SCHEDULES & DETAILS

ALTERNATE BID #1 VRF ELECTRICAL & CRONTROL

PLUMBING SCHEDULES & DETAILS

305A PLUMBING WATER PLAN

305B PLUMBING WATER PLAN

PLUMBING SCHEDULES

SITE SANITARY & STORM DRAINS

LIGHTING PLAN

POWER PLAN

ELECTRICAL DETAILS

LOW VOLTAGE PLANS

FIRE ALARM PLANS

FINISHED WOOD

ROUGH WOOD

PLASTER, GYPSUM

BATT INSULATION

RIGID INSULATION

BUILDING SECTION

REFERENCE NO.

DOOR NUMBER

SYMBOLS LEGEND

SPACE LABEL

DETAIL

INDICATOR

ELEVATION

REFERENCE

WINDOW

DESIGNATION

REVISION NUMBER

PARTITION TYPE

NEW DOOR & FRAME

CENTER LINES OR

MATCH LINES

PROJECT LIMIT LINES

OR PROPERTY LINES

HIDDEN LINES

LIST OF DRAWINGS

METAL

PLYWOOD

ABBREVIATIONS

A/C AIR CONDITION

ACT ACOUSTICAL CEILING TILE

ADA AMERICANS WITH DISABILITIES ACT

AFF ABOVE FINISH FLOOR

AHU AIR HANDLING UNIT

ALUM ALUMINUM

AMP AMPERE

APPROX APPROXIMATELY

AVG AVERAGE

BM BEAM OR BENCHMARK

BRG BEARING

CFM CUBIC FEET PER MINUTE

CLG CEILING

CLG HT CEILING HEIGHT

CMU CONCRETE MASONRY UNIT

CONC CONCRETE

CONT CONTNUE/CONTINUOUS

CPT CARPET

CT CERAMIC TILE

EA EACH

ELEC ELECTRIC

EXG EXISTING

EXT EXTERIOR

F FARENHEIT

FDTN FOUNDATION

FFE FINISH FLOOR ELEVATION

CONCRETE MASONRY

HOLLOW CLAY TILE

REMOVE EXISTING

DOOR & FRAME

REMOVE EXISTING WALL

FLR FLOOR

FLUOR FIX FLUORESCENT FIXTURE

FPM FEET PER MINUTE

FTG FOOTING

GAL GALLON

GYP GYPSUM

GWB GYPSUM BOARD

HVAC HEATING, VENTILATION, & AIR CONDITIONING

HWS HOT WATER SUPPLY

HWR HOT WATER RETURN

INSUL INSULATION

LED LIGHT EMITTING DIODE

LT GA LIGHT GAGE

MAX MAXIMUM

MECH MECHANICAL

MFR MANUFACTURER

MIN MINIMUM

MO MASONRY OPENING

MOD MODEL, MODULE

MTD MOUNTED

N NORTH

NA NOT APPLICABLE

NO NUMBER

OC ON CENTER

OF OWNER FURNISHED

PERIM PERIMETER

PLAS PLASTER

PSI POUNDS PER SQUARE INCH

PT PREASSURE TREATED

PTL PORCELAIN TILE

RB RESILIENT BASE

REIN REINFORCED

REQD REQUIRED

RM ROOM

SH SILL HEIGHT

SHTHG SHEATHING

SS SERVICE SINK

STOR STORAGE

SV SHEET VINYL

TEMP TEMPERATURE

TSTAT THERMOSTAT

TYP TYPICAL

UV ULTRAVIOLET

V VOLT

VCT VINYL COMPOSITION TILE

VFAT VINYL FACED ACOUSTICAL TILE

W/ WITH

W/O WITHOUT

WDW WINDOW

AERIAL VIEWS OF SITE AND BUILDING

REMOVE EXISTING

WINDOW & FRAME

EXISTING DOOR & FRAME

305A-11

COVER SHEET

GI-001

11/15/2017 SBP

Comfort Design

Engineers & Electrical

620 Pennsylvania Ave

Winchester, VA 22601

Phone 540-665-2846

Fax 540-667-3284

CD i

100% DOCUMENTS

VA FORM 08-6231

305 A/B

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

510 Butler Ave., Martinsburg, WV

ARCHITECT/ENGINEERS/CONSULTANTS:

Building 305A/B Renovations

Martinsburg, WV VAMC

613-15-128 Office of Construction and Facilities Management

LD

Structural Concepts Inc.

132 West Piccadilly

Street Winchester, VA 22601

EXISTING BRICK COLUMNS (TYP.)

EXISTING STEEL SUPPORTS (TYP.)

325 MIGRATION LN., GERRADSTOWN, WV

25420 304-267-2120

PLLC

GROVE & DALL’OLIO

A R C H I T E C T S

11/15/2017 SBP

Comfort Design

Engineers & Electrical

620 Pennsylvania Ave

Winchester, VA 22601

Phone 540-665-2846

Fax 540-667-3284

CD i

FOR CONSTRUCTION

B

A

C

D

E

F

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

305 A/B

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

510 Butler Ave., Martinsburg, WV

ARCHITECT/ENGINEERS/CONSULTANTS:

Building 305A/B Renovations

Martinsburg, WV VAMC

613-15-128 Office of Construction and Facilities Management

LD

Structural Concepts Inc.

132 West Piccadilly

Street Winchester, VA 22601

PHOTOGRAPHS OF CRAWLSPACE SHOWING BRICK PIERS AND STEEL

SUPPORTS

GENERAL NOTES:

1 - REMOVE ALL RADIATORS (NOT SHOWN), AS WELL AS,

RADIATOR PIPING

2 - GC IS TO STOP WORK AND ALERT THE VA

IF THE GC ENCOUNTERS MOLD OR SUSPECTED ASBESTOS

CONTAINING MATERIALS NOT IDENTIFIED IN THE ASBESTOS WORK

PLAN TO BE ABATED (SEE ASBESTOS ABATEMENT SPECIFICATIONS

AND WORK PLAN IN PROJECT MANUAL.)

3 - REMOVE ALL CONDUIT, DUCTWORK, WIRING AND PIPING ON

INTERIOR AND EXTERIOR THAT WILL NOT BE UTILIZED IN NEW

WORK, ALL CONDUIT IN FINISHED SPACES MUST BE CONCEALED IN

FINISHED WALLS AND CEILINGS

CRAWLSPACE DEMOLITION NOTES:

1 - REMOVE ALL STEAM AND PLUMBING PIPING, SPRINKLERS,

WIRING, DUCTWORK, AND CABLING.

2 - PROTECT EXISTING BATT AND RIGID INSULATION TO REMAIN.

3 - PROTECT ALL HVAC, PLUMBING, DATA, ELECTRICAL, AND

TELECOMMUNICATION SYSTEMS PASSING THROUGH CRAWLSPACE

THAT FEED SPACES OTHER THAN 305A AND 3058B.

4 - CONTRACTOR SHALL VISIT THE SITE AND DETERMINE THE

TOTAL SCOPE OF DEMOLITION WORK THAT INCLUDES ALL

FIXTURES, EQUIPMENT, STEAM/DOMESTIC WATER PIPING, ETC.,

WHETHER SPECIFICALLY SHOWN OR NOT, THAT NEEDS TO BE

REMOVED/CAPPED AND DISPOSED OF, AND INCLUDED IN THE

CONTRACT PRICE.

5 - CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL SPRINKLER

PIPING HEADS EXCEPT FOR THE INCOMING SPRINKLER BACKFLOW

ASSEMBLY. CONTRACTOR SHALL TEST THE SPRINKLER BACKFLOW

ASSEMBLY AND ADVISE THE VA OF THE CONDITION AND PROVIDE

ANY RECOMMENDATIONS FOR REPAIRS OR REPLACEMENT WITH

AN ESTIMATE OF ADDITIONAL COST.

6 - REMOVE BACK TO ORIGIN OF EITHER 4" OF "T" OR "Y" FITTING

AT FLOOR OF CRAWL SPACE FOR ALL DRAINAGE PIPING, THEN

PLUG OR CAP.

7 - SEE DEMOLITION SPECIFICATIONS FOR ADDITIONAL

INFORMATION ESPECIALLY, BUT NOT EXCLUSIVELY, SECTION

230511 PARAGRAPH 3.5

LEAD IN PAINT STATEMENT:

Due to the age of the 305AB buildings, the paint within and on the outside of the building should be considered lead containing.* During the demolition, painted wood, metal, drywall, masonry and other building components may be impacted. If this occurs, the Contractor is required to fully comply with the Occupational Safety and Health Administration (OSHA) Lead in Construction standard (29 CFR 1926.62) which includes, but is not limited to training, exposure monitoring and implementing engineering controls to prevent dust dispersion to the general building environment. The Contractor shall submit documentation of worker training and their proposed dust control strategy to the COTR.

Any surfaces with peeling paint called out to be demolished are to be wet scraped by licensed workers prior to demolition.

To ensure the effectiveness of the engineering controls, the VA may employ an industrial hygienist to collect perimeter air samples for lead outside of the construction area. At the conclusion of the work, a representive samples of the waste stream generated shall be collected in the presence of VAIH and submitted for analysis by the Toxicity Characteristic Leaching Procedure (TCLP) to determine the appropriate disposal method in accordance with the Environmental Protection Agency (EPA) Resource Conservation and Recovery Act (RCRA). All waste generated shall be maintained on site until results of the sample are determined. If sampling indicates waste is hazardous, the Contractor shall turn the waste over to the VA for disposal by the VA contracted hazardous waste contractor.

*Prior to this project, many presumed lead containing materials were coated with a lead encapsulation paint.

ALL REMOVAL NOTES APPLY TO

ALL ITEMS OF THIS TYPE IN

BOTH 305A AND 305B.

3/16" = 1'-0" 2F

BASEMENT DEMO - 305A

3/16" = 1'-0" 2C

BASEMENT DEMO - 305B

CRAWLSPACE DEMOLITION

PLAN

AD-101

DN

REMOVE EXISTING WINDOWS AND

FRAMES

EXISTING SPRINKLER EQUIPMENT BACKFLOW

PREVENTER IN THIS LOCATION (CURRENT CLOSET

AREA) TO REMAIN

(PROTECT DURING CONSTRUCTION)REMOVE ALL FIXTURES, FITTINGS, AND TOILET

PARTITIONS

REMOVE ALL WALL AND FLOOR

CERAMIC TILE

REMOVE ALL EXISTING FIXTURES,

WIRING, AND CONDUIT

REMOVE EXISTING SATELLITE DISHES

AND WIRING/CONDUIT BACK TO AND

INSIDE BUILDING. REMOVE SUPPORTING

POSTS, TO 6" BELOW GRADE.

R E

M O

V E

F O

R D

O O

R

REMOVE CONCRETE

BASES AT BATH

REMOVE ALL REMAINING CEILING

TILES AND ALL CEILING BOARDS AND

FINISHES

REMOVE HVAC SYSTEM,

WIRING, & PIPING FROM ATTIC

REMOVE SECTION OF WALL FOR

NEW DOOR

REMOVE SECTION OF WALL

FOR NEW DRINKING FOUNTAIN

REMOVE WALL REMNANTS & PIPING

REMOVE EXISTING STEPS,

PORCH, AND SLAB. PROTECT

SIDEWALK LEADING TO SLAB

REMOVE EQUIPMENT, BOLLARDS, CONCRETE

PAD, AND GRAVEL

EXISTING SIDEWALK

TO REMAIN

REMOVE PLYWOOD FROM ALL

WALLS AND REMOVE

TELECOMMUNICATION

EQUIPMENT AND WIRING (TYP.)

REMOVE CAGES AT TWO WINDOWS

REMOVE DRAIN BELOW

GRADE, SEAL PIPE

REMOVE EXISTING DOOR,

PROTECT FRAME FOR REUSE

REMOVE AIR

CONDITIONER

REMOVE UNUSED VENT PIPE

PRIOR TO DEMOLITION, RELOCATE

CONDUIT AND DEVICES TO WALLS

THAT WILL REMAIN

REMOVE WOOD INSET FRAME

REMOVE WASHER/DRYER HOOK-UPS & VENT

ABATE ASBESTOS-CONTAINING TILE & MASTIC

UNDER WALL BEHIND TOILETS (ASSUME 12SF)

REMOVE ALL FIXTURES, FITTINGS,

AND TOILET PARTITION FASTENERS

REMOVE HOT WATER HEATER

AND SURROUNDING WALLS

REMOVE ANY REMAINING CEILING

TILES AND ALL CEILING BOARDS

AND FINISHES

REMOVE ANY REMAINING

LIGHT FIXTURES, WIRING,

AND CONDUIT

REMOVE PULL-DOWN

SCREEN

REMOVE EXISTING STEPS,

PORCH, AND SLAB. PROTECT

SIDEWALK LEADING TO SLAB

REMOVE ALL CERAMIC

FLOOR AND WALL TILE

REMOVE ANY

REMAINING DRY WALL &

FURRING (TYP.)

REMOVE CONCRETE

BASES AT HWH

CLOSET & BATH

REMOVE WALL REMNANTS AND

2X10 BASE

REMOVE HVAC SYSTEM,

WIRING, & PIPING FROM ATTIC

EXISTING SIDEWALK

TO REMAIN

REMOVE EQUIPMENT,

BOLLARDS, CONCRETE

PAD, AND GRAVEL

PROTECT EXISTING SPEAKER (TYP.)

REMOVE EXISTING

DRINKING FOUNTAIN

325 MIGRATION LN., GERRADSTOWN, WV

25420 304-267-2120

PLLC

GROVE & DALL’OLIO

A R C H I T E C T S

11/15/2017 SBP

Comfort Design

Engineers & Electrical

620 Pennsylvania Ave

Winchester, VA 22601

Phone 540-665-2846

Fax 540-667-3284

CD i

FOR CONSTRUCTION

B

A

C

D

E

F

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

305 A/B

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

510 Butler Ave., Martinsburg, WV

ARCHITECT/ENGINEERS/CONSULTANTS:

Building 305A/B Renovations

Martinsburg, WV VAMC

613-15-128 Office of Construction and Facilities Management

LD

Structural Concepts Inc.

132 West Piccadilly

Street Winchester, VA 22601

3/16" = 1'-0" 2F

1 - DEMO PLAN 305A

3/16" = 1'-0" 2C

1 - DEMO PLAN 305B

GENERAL NOTES:

1 - REMOVE ALL DASHED PARTITIONS

2 - REMOVE EXISTING INTERIOR AND EXTERIOR WINDOW

TREATMENTS

3 - REMOVE ALL DRYWALL AND FURRING

4 - REMOVE ALL REMAINING RADIATORS (NOT SHOWN), AS WELL

AS, RADIATOR PIPING

5 - GC IS TO STOP WORK AND ALERT THE VA

IF THE GC ENCOUNTERS MOLD OR SUSPECTED ASBESTOS

CONTAINING MATERIALS NOT IDENTIFIED IN THE ASBESTOS

WORK PLAN TO BE ABATED (SEE ASBESTOS ABATEMENT

SPECIFICATIONS AND WORK PLAN IN PROJECT MANUAL.)

6 - REMOVE ALL CONDUIT, WIRING, DUCTWORK AND PIPING ON

INTERIOR AND EXTERIOR THAT WILL NOT BE UTILIZED IN NEW

WORK, ALL CONDUIT IN FINISHED SPACES MUST BE CONCEALED

IN FINISHED WALLS AND CEILINGS

7 - REMOVE GABLE END VENTS AND FRAMES AT BOTH ENDS.

8- REMOVE FOUR SMALL HORIZONTAL WINDOWS AT EXISTING

BATHROOMS. REPAIR MASONRY WALL. INFILL FRAME TO MATCH

EXISTING.

9 - REMOVE HOT WATER HEATER AND ALL HOT AND COLD

WATER PIPING BACK TO TEE BRANCH OF ORIGIN. NEW WORK

TO BEGIN AT THE INCOMING WATER MAIN.

10 - DEMOLITION TO INCLUDE SPECIFICATION SECTIONS 220511

PARAGRAPH 3.6 AND SPECIFICATION SECTION 230511

PARAGRAPH 3.5 AS WELL AS OTHER PROVISIONS IN DEMO

SPECS.

11 - REMOVE SUBFLOOR AND CONCRETE SLAB IN EXISTING

RESTROOM AREA AS NEEDED TO MAKE FLUSH WITH ADJACENT

FLOORING.

12 - REMOVE CONCRETE BASIN AND SLAB AT EXISTING HOT

WATER HEATER. ADD FLOOR JOISTS AND SUBFLOOR AS

NEEDED TO MATCH SURROUNDING FLOOR FRAMING & DETAILS.

GROUND FLOOR DEMOLITION

PLAN

AD-101

ALL REMOVAL NOTES APPLY TO

ALL ITEMS OF THIS TYPE IN

BOTH 305A AND 305B.

AD-102

AREA OF EXISTING HVAC

EQUIPMENT THAT IS TO

BE DEMOLISHED AND

REMOVED

AREA OF EXISTING HVAC

EQUIPMENT THAT IS TO

BE DEMOLISHED AND

REMOVED

EXISTING ATTIC TRUSSES APPROX. 24"

O.C. TO REMAIN AND REPAIRED AS PER

STRUCTURAL DRAWINGS

325 MIGRATION LN., GERRADSTOWN, WV

25420 304-267-2120

PLLC

GROVE & DALL’OLIO

A R C H I T E C T S

11/15/2017 SBP

Comfort Design

Engineers & Electrical

620 Pennsylvania Ave

Winchester, VA 22601

Phone 540-665-2846

Fax 540-667-3284

CD i

FOR CONSTRUCTION

B

A

C

D

E

F

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

305 A/B

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

510 Butler Ave., Martinsburg, WV

ARCHITECT/ENGINEERS/CONSULTANTS:

Building 305A/B Renovations

Martinsburg, WV VAMC

613-15-128 Office of Construction and Facilities Management

LD

Structural Concepts Inc.

132 West Piccadilly

Street Winchester, VA 22601

GENERAL NOTES:

1 - REMOVE ALL CONDUIT, WIRING, DUCTWORK AND PIPING ON

INTERIOR AND EXTERIOR THAT WILL NOT BE UTILIZED IN NEW

WORK, ALL CONDUIT IN FINISHED SPACES MUST BE CONCEALED

IN FINISHED WALLS AND CEILINGS

2 - REMOVE GABLE END VENTS AND FRAMES AT BOTH ENDS.

3 - REMOVE ALL VENTING PIPE (INCLUDING THROUGH ROOF).

EXISTING ROOF PENETRATIONS MAY BE REUSED, PROVIDED

THE ROOF OPENING IS SUFFICIENT IN SIZE TO ACCOMMODATE

VENTS SIZED TO CODE (3" MINIMUM FOR HOAR FROST).

4 - TRUSS MEMBERS TO BE INSTALLED WHERE MISSING AND

REPAIRED WHERE DAMAGED AND CUT.

ATTIC DEMOLITION NOTES:

1 - REMOVE ALL REMAINING EXISTING HVAC EQUIPMENT,

DUCTWORK, WIRING, CONDUIT, AND CABLING

2 - HVAC UNITS IN ATTIC MAY NEED TO BE DISASSEMBLED IN

ORDER TO BE REMOVED

3 - ALL INSULATION AND RADIANT BARRIER TO BE REMOVED

4 - CAT WALK TO REMAIN

5 - PROTECT EXISTING ATTIC LIGHTING

6 - REMOVE REFLECTIVE THERMAL BARRIER FROM ATTIC

3/16" = 1'-0"

ATTIC DEMO - 305A

3/16" = 1'-0"

ATTIC DEMO - 305B

ATTIC DEMOLITION PLAN

AD-103

EXISTING ROOF TO REMAIN

USE OR REMOVE EXISTING VENTS (SEE NOTE

ON SHEET AD-103)

PROTECT EXISTING SAPLING

21" TUBULAR SKYLIGHTS, APPROXIMATE LOCATIONS SHOWN. SEE

DETAIL ON SHEET AE-902

NEW ROOFING TO MATCH EXISTING

NEW GUTTER AND DOWNSPOUTS TO MATCH

EXISTING

INSTALL THREE AMERICAN HOLLY BUSHES

(24" POTS) 4'-0" ON CENTER AT EACH SIDE

OF EACH PORCH. FERTILIZE AND MULCH.

INSTALL 8" TOPSOIL AND RE-SEED.

NEW 6" CONCRETE SLAB, EXTEND 12"

BEYOND HVAC UNITS. SEE MH-5

PLUMBING VENTEXISTING ROOF TO REMAIN

NEW ROOFING TO MATCH EXISTING

NEW GUTTER AND DOWNSPOUTS TO MATCH

EXISTING

INSTALL THREE AMERICAN HOLLY BUSHES

(24" POTS) 4'-0" ON CENTER AT EACH SIDE OF

EACH PORCH. FERTILIZE AND MULCH.

APPROXIMATE LOCATION OF EXISTING

ROOF VENTS. MINIMUM 3" NEEDED FOR

REUSE FOR 2" VENTS. REDUCTION TO 2"

PERMITTED ONCE 12" PAST INSULATION ON

INTERIOR. IF NOT REUSED, CAP AND SEAL.

INSTALL 8" TOPSOIL AND RE-SEED.

NEW 6" CONCRETE SLAB, EXTEND 12"

BEYOND HVAC UNITS. SEE MH-5

325 MIGRATION LN., GERRADSTOWN, WV

25420 304-267-2120

PLLC

GROVE & DALL’OLIO

A R C H I T E C T S

11/15/2017 SBP

Comfort Design

Engineers & Electrical

620 Pennsylvania Ave

Winchester, VA 22601

Phone 540-665-2846

Fax 540-667-3284

CD i

FOR CONSTRUCTION

B

A

C

D

E

F

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

305 A/B

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

510 Butler Ave., Martinsburg, WV

ARCHITECT/ENGINEERS/CONSULTANTS:

Building 305A/B Renovations

Martinsburg, WV VAMC

613-15-128 Office of Construction and Facilities Management

LD

Structural Concepts Inc.

132 West Piccadilly

Street Winchester, VA 22601

3/16" = 1'-0" 2F

ROOF PLAN - 305B

3/16" = 1'-0" 2C

ROOF PLAN - 305A

AE-130

ROOF/SITE PLAN

SITE WORK NOTES:

1 - PREPARE SITE WITHIN CONTRACT LIMITS, INCLUDING

CLEARING, GRUBBING, STRIPPING, AND STOCKPILING

TOPSOIL, AS REQUIRED FOR ALL SITE IMPROVEMENTS. HAUL

FROM SITE EXCESS UNSUITABLE MATERIALS UNLESS

OTHERWISE INSTRUCTED BY VA REPRESENTATIVE.

2 - REMOVE UNSUITABLE FILL FOR BACKFILL.

3 - CLEAN SITE AFTER COMPLETION OF PROJECT.

4 - THE CONTRACTOR SHALL LEAVE A MINIMUM OF 6" TOP

SOIL ON ALL EXPOSED AREAS OF LAND DISTURBED BY

CONSTRUCTION OR REGRADING.

5 - PROVIDE AND INSTALL COMPLETE CISTERN DRAIN SYSTEM.

SEE PL-2.

NOTE: SEED, FERTILIZE, AND SPREAD STRAW ON ALL

EXPOSED DISTURBED FINISH GRADING.

AE-201 7E

8' - 1"

8' - 1"

Floor Finish Legend

12" X 12" VCT

12" X 12"

PORCELAIN TILE

CARPET TILE

EXISTING

LUXURY VINYL TILE

AE-201

1C

AE-201

1F

305A-8

A

A A B

A A A A A A A

AAAAAAA

PAYROLL

305A-12

PAYROLL

305A-11

PAYROLL

305A-10

FILE RM.

305A-9

WORK ROOM

305A-4

PAYROLL

305A-7

WOMEN W.C.

305A-1

MEN W.C.

305A-3

MECH. RM.

305A-5

C O

P Y

A R

E A

WHITE BOARD

PROVIDED BY

VA INSTALLED

BY GC

(1) 55" MONITOR WITH CABLE

RUN TO CLOSET IN 307

MOUNTED WITH BOTTOM OF

MONITOR 40" AFF

VESTIBULE

305A-2

BIOMED CL

305A-14

5' CONTINUOUS

SHELF

5' - 0"

3' - 4"

3A

AE-202

AE-202

305A-12

305A-11

305A-9

305A-10

305A-7

305A-4A

305A-4B

305A-4 305A-2

305A-3

305A-13

/4

2' - 6"

/8

/8

TUBULAR

SKYLIGHTING

DEVICE (TYP)

18" ADJUSTABLE

SHELF

18" ADJUSTABLE

SHELF 3

RECESSED

FIRE CABINET

HALL

305A-8

413 SF

CORRIDOR

305A-13

305A-1

305A-5A

271 SF

ENTRY FOYER

305A

AE-601

5B

AE-601

1D

7D

5D

3D

1B

3B7B

AE-602

1D

6D1F

32 SF

WORK ROOM CL

305A-CL

ACCENT WALL

SPRINKLER

305A-14

BI-LEVEL

DRINKING

FOUNTAIN

TRANSLUCENT GLAZING AT

BATHROOM WINDOWS

P1

P1

P3

P1

P3

P1

P2

P2

P1

P3

17' - 7 1/2"

/8

" 3" CONCRETE

PAD

4' BENCH BOLTED TO SLAB AT

EACH END

NEW CONCRETE PAD ON UNDISTURBED GRAVEL. EXTEND 12"

BEYOND EQUIPMENT IN ALL DIMENSIONS. POUR CONCRETE

RIGHT UP TO BUILDING WALL. PROVIDE POSITIVE DRAINAGE

AWAY FROM BUILDING.

NEW BRUSH FINISH CONCRETE

STEPS AND PORCH WITH BRICK

VENEER

AE-602 5F

305A-5B

EXISTING DOORS

TO REMAIN

EXISTING DOORS

TO REMAIN

6B

23' - 3 9/16"

RECESSED

FIRE CABINET

C

14' - 0"

8' - 11 3/4" 13' - 8 11/16"

/8

/8

A L

IG

N

ALIGN

7' - 3 5/8" 6' - 10 3/4"

1 1

6B

79' - 6"

STAINLESS STEEL NON-SLIP

NOSINGS AT EACH TREAD.

INSTALL NEW

FLOORING AND BASE

AT DRINKING

FOUNTAIN NICHE TO

MATCH EXISTING

HALL FLOORING,

CONCEAL SEAM.

PROVIDE CONTROL

JOINT AT EXTERIOR

8' - 7 5/8"

12' - 2 1/8"

(COORDINATE WITH SPECIFIED TOILET CORNER REQUIREMENTS)

1' - 3 3/4" 8 1/2" CLEAR INTERIOR SPACE

RESET LOOSE BRICKS AND

POINT UP MASONRY

OPENINGS AT WINDOWS

INFILL MASONRY AT ALL

POWER RECEPTACLE

SCARS

INFILL MASONRY TO FULL DEPTH WITH MASONRY

WHERE MISSING AT MULTIPLE LOCATIONS

INFILL FLOOR TO MAKE

IT FLUSH WITH

ADJACENT FLOOR

325 MIGRATION LN., GERRADSTOWN, WV

25420 304-267-2120

PLLC

GROVE & DALL’OLIO

A R C H I T E C T S

11/15/2017 SBP

Comfort Design

Engineers & Electrical

620 Pennsylvania Ave

Winchester, VA 22601

Phone 540-665-2846

Fax 540-667-3284

CD i

FOR CONSTRUCTION

B

A

C

D

E

F

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

305 A/B

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

510 Butler Ave., Martinsburg, WV

ARCHITECT/ENGINEERS/CONSULTANTS:

Building 305A/B Renovations

Martinsburg, WV VAMC

613-15-128 Office of Construction and Facilities Management

LD

Structural Concepts Inc.

132 West Piccadilly

Street Winchester, VA 22601

1/4" = 1'-0" 2F

FLOOR PLAN - 305A

GROUND FLOOR PLAN - 305A

AS-101

GENERAL NOTES: (REFER TO 305A AND 305B)

1 - EXTERIOR BRICK AND TERRA COTTA WALLS ARE TO BE REPAIRED

WHERE DAMAGED. INFILL WHERE MISSING WITH MATCHING BRICK,

BLOCK, TERRA COTTA AND/OR GROUT OR ANY COMBINATION

THEROF TO RESTORE INTEGRITY OF WALL.

2 - REMOVE AND REPLACE WOOD FLOOR AS NECESSARY TO

PROVIDE FLUSH AND LEVEL SURFACE FOR PLYWOOD

UNDERLAYMENT.

R E

F

2480 2480 36803680 6080

24803680 3080 60804880

R C P

R C P

R C P

R C P

R C P

R C P

R C P

R C P

R C P

R C P

R C P

R C P

R C P

R C P

R C P

R C P

ATTEAPATTEAPATTEAPATREAP

ATTEAP ATTEAPATTEAP

BBF

F F

FF

B B F

FF

B B F

FF

B B F

F F

B B F

BBF

F F

FF

B B F

FF

B B F

PRIORITY

P R

IO

R

IT

Y

P R

IO

R

IT

Y

PRIORITY

P R

IO

R

IT

Y

EP

P R

IO

R

IT

Y

EP

P R

IO

R

IT

Y

P R

IO

R

IT

Y

PRIORITY PRIORITY

PRIORITY

P R

IO

R

IT

Y

P R

IO

R

IT

Y

P R

IO

R

IT

Y

PRIORITY PRIORITY

S P

S

P SPSP

P R

IO

R

IT

Y

EPPRIORITY

PRIORITY

60 60

BIF WHIP

BIF WHIP

2460 2460

2460 2460

AE-2017D

AE-201

AE-201

1B

1E

CHIEF OF SERVICE

305B-3

CONFERENCE

305B-4

MECH RM

305B-2

FINANCE CHIEF

305B-5

ACCTG CHIEF

305B-6

K'ETTE

305B-8

VOUCHER EXAM

305B-7E

INTERN

305B-7G

FINAN. TECH.

305B-7H

STORAGE

305B-9

COPY CENTER

TWO

LEKTREIVERS

8' - 1"

BUDGET AN.

305B-7D

ACCT.

305B-7B

ACCTG. TECH.

305B-7A

RECEP.

305B-1A

INTERN

305B-7F

TUBULAR

SKYLIGHTING

DEVICE (TYP)

1A

AE-202

305B-1A

305B-9

305B-6

305B-4 305B-5305B-3

305B-2

305B-1B

RAIN LEADER, TYP.

B

5' WIDE, 5' HIGH

CONTINUOUS

SHELF

BASE CABINETS

C A A A A A A A A A

AAAAAAAAA

684 SF

FISCAL

305B-1

SHELVES

AE-601

2F

4F

AE-6011F

ACCT.

305B-7C

AE-202

NEW CONCRETE PAD ON

UNDISTURBED GRAVEL. EXTEND 36"

BEYOND EQUIPMENT IN ALL

DIMENSIONS. POUR CONCRETE RIGHT

UP TO BUILDING WALL. PROVIDE

POSITIVE DRAINAGE AWAY FROM

BUILDING.

P1

P1

P1 P3 P1

P3

P2

P2

/8

10' - 9 1/2" 11' - 2 1/2"

4' BENCH BOLTED TO SLAB AT

EACH END

Floor Finish Legend

12" X 12" VCT

CARPET TILE

EXISTING

LUXURY VINYL TILE

ACCENT WALL

80" H PANELS

80" H PANELS

30" H PANEL

PROVIDE CONTROL JOINT

AT EXTERIOR WALL GWB

AND AT CEILING

/4

/4

RECESSED

FIRE CABINET

5'-0" MIN.

1 1

1 1

NEW BRUSH FINISH CONCRETE

STEPS AND PORCH WITH BRICK

VENEER

STAINLESS STEEL NON-SLIP

NOSINGS AT EACH TREAD.

A

5' - 0" MIN.

8' - 7 1/2" 8' - 7 1/2"

PROVIDE CONTROL JOINT

AT EXTERIOR WALL GWB

AND AT CLG

RESET LOOSE BRICKS AND POINT UP

MASONRY OPENINGS AT WINDOWS

INFILL MASONRY TO FULL DEPTH WITH

MASONRY WHERE MISSING AT

MULTIPLE LOCATIONS

325 MIGRATION LN., GERRADSTOWN, WV

25420 304-267-2120

PLLC

GROVE & DALL’OLIO

A R C H I T E C T S

11/15/2017 SBP

Comfort Design

Engineers & Electrical

620 Pennsylvania Ave

Winchester, VA 22601

Phone 540-665-2846

Fax 540-667-3284

CD i

FOR CONSTRUCTION

B

A

C

D

E

F

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

305 A/B

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

510 Butler Ave., Martinsburg, WV

ARCHITECT/ENGINEERS/CONSULTANTS:

Building 305A/B Renovations

Martinsburg, WV VAMC

613-15-128 Office of Construction and Facilities Management

LD

Structural Concepts Inc.

132 West Piccadilly

Street Winchester, VA 22601

1/4" = 1'-0"

FLOOR PLAN - 305B

GROUND FLOOR PLAN - 305B

AS-102

ALIGN

GENERAL NOTES: (REFER TO 305A AND 305B)

1 - EXTERIOR BRICK AND TERRA COTTA WALLS ARE TO BE

REPAIRED WHERE DAMAGED. INFILL WHERE MISSING WITH

MATCHING BRICK, BLOCK, TERRA COTTA AND/OR GROUT OR ANY

COMBINATION THEROF TO RESTORE INTEGRITY OF WALL.

2 - REMOVE AND REPLACE WOOD FLOOR AS NECESSARY TO

PROVIDE FLUSH AND LEVEL SURFACE FOR PLYWOOD

UNDERLAYMENT.

2 - ROOF

12' - 0"

1 - LEVEL 1

3' - 0"

GRADE

0' - 0"

ACCESS DOOR

B A A A A A A A AA

REPAIR CONCRETE BASE AT PILASTER

REPLACE BROKEN COMPONENTS OF

DOWNSPOUT AND COLLECTION PIPE

NEW BRICK VENEER TO MATCH

EXISTING AT BOTH PORCHES

2 - ROOF

12' - 0"

1 - LEVEL 1

3' - 0"

GRADE

0' - 0"

/3

DOWNSPOUT, TYP.

ACCESS DOOR

C

A A A A A A A A A

SOLARTUBE SKYLIGHTS

REMOVE SMALL WINDOWS

AND REPAIR WALL

REMOVE VENT AND REPAIR WALL

REPLACE BOTTOM 24" OF DAMAGED

DOWNSPOUT WITH MATCHING

DOWNSPOUT. REPLACE PVC CONNECTOR

REMOVE ALL PIPING CONDUIT, WIRING, AND ELECTRICAL CONNECTION.

REPAIR HOLES IN WALL AND SOFFIT. REPLACE DAMAGED SOFFIT AND

BRICK WITH NEW MATERIALS TO MATCH EXISTING

C

(2) NEW 35" X 22" LOUVERS

WITH 3' MINIMUM BRICKED

SPACE BETWEEN

NEW VENT

NEW GUTTER & DOWNSPOUT

TO A NEW SPLASH BLOCK

NEW ROOF TO MATCH

EXISTING

GALVANIZED STEEL COLUMN

AND HANDRAILS, FIELD

OUCH-UP GALVANIZED

COATING AFTER ASSEMBLY

NEW BRICK VENEER AT

PORCH & STAIR TO MATCH

EXISTING

2 - ROOF

12' - 0"

1 - LEVEL 1

3' - 0"

GRADE

0' - 0"

DEMO VENT, REPAIR WALL.

TOOTH-IN NEW MASONRY

SOLARTUBE SKYLIGHTS

REMOVE CONDENSATE

PIPE, REPAIR MASONRY

INSTALL THREE AMERICAN

HOLLY BUSHES (4" POTS)

4'-0" ON CENTER AT EACH

SIDE OF NEW PORCHES.

FERTILIZE AND MULCH.

NEW SCONCE

NEW CONCRETE STEPS WITH CAST

ALUMINUM, NON-SLIP NOSINGS (TYP). SEE S2.1

2 - ROOF

12' - 0"

1 - LEVEL 1

3' - 0"

GRADE

0' - 0"

DEMO VENT, REPAIR WALL.

TOOTH-IN NEW MASONRY

NEW CONCRETE STEPS WITH CAST ALUMINUM,

NON-SLIP NOSINGS (TYP). SEE S2.1

SOLARTUBE SKYLIGHTS

REMOVE CONDENSATE

PIPE, REPAIR MASONRY

REMOVE LIGHT,

REPLACE MASONRY

INSTALL THREE AMERICAN

HOLLY BUSHES (4" POTS)

4'-0" ON CENTER AT EACH

SIDE OF NEW PORCHES.

FERTILIZE AND MULCH.

REMOVE WOOD PLANK. REPAIR

WALL AS NECESSARY FOR NEW

SCONCE INSTALLATION

2 - ROOF

12' - 0"

1 - LEVEL 1

3' - 0"

GRADE

0' - 0"

ACCESS DOOR

3' - 4"

A A A A A A A A

(2) NEW 35" X 22" LOUVERS WITH 3" MINIMUM BRICKED SPACE BETWEEN

REMOVE VENTS, REPAIR MASONRY

REMOVE SMALL WINDOWS, TOOTH IN NEW MASONRY

PROVIDE AND INSTALL NEW SELF-CLOSING

FOUNDATION VENTS (TYP. AT ALL ELEVATIONS)

CONNECT THREE DOWNSPOUTS ON THIS ELEVATION TO NEW CISTERN. SEE SHEET PL-2

REMOVE EXISTING VENT.

INSTALL NEW

VENT/LOUVER FOR MECH.

ROOM EXHAUST

C

C

DRAIN FOR SPRINKLERS

TO REMAIN

REMOVE FAN

REPOINT JOINTS

WHERE OPEN AT

CRACK. REPLACE 3

CRACKED BRICKS.

NEW GUTTER & DOWNSPOUT

TO A NEW SPLASH BLOCK

NEW ROOF TO MATCH

EXISTING

GALVANIZED STEEL COLUMN

AND HANDRAILS, FIELD

OUCH-UP GALVANIZED

COATING AFTER ASSEMBLY

NEW BRICK VENEER AT

PORCH & STAIR TO MATCH

EXISTING

2 - ROOF

12' - 0"

1 - LEVEL 1

3' - 0"

GRADE

0' - 0"

ACCESS DOOR

A A A A A A A A A B

TRANSLUCENT PRIVACY GLAZING

AT BATHROOMS

REMOVE ALL PIPING CONDUIT, WIRING, AND ELECTRICAL CONNECTIONS. REPAIR HOLES IN WALL AND SOFFIT. REPLACE DAMAGED SOFFIT AND BRICK WITH NEW MATERIALS TO MATCH EXISTING

REPAIR 2 EXISTING HOLES AND HOLE WHERE A/C UNIT HAD BEEN.

INSTALL NEW BRICK TO REPAIR OPENINGS LARGER THAN 3/4".

REPAIR WALL WHERE A/C UNIT HAD BEEN,

TOOTH IN NEW MATCHING BRICK MASONRY

325 MIGRATION LN., GERRADSTOWN, WV

25420 304-267-2120

PLLC

GROVE & DALL’OLIO

A R C H I T E C T S

11/15/2017 SBP

Comfort Design

Engineers & Electrical

620 Pennsylvania Ave

Winchester, VA 22601

Phone 540-665-2846

Fax 540-667-3284

CD i

FOR CONSTRUCTION

B

A

C

D

E

F

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

305 A/B

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

510 Butler Ave., Martinsburg, WV

ARCHITECT/ENGINEERS/CONSULTANTS:

Building 305A/B Renovations

Martinsburg, WV VAMC

613-15-128 Office of Construction and Facilities Management

LD

Structural Concepts Inc.

132 West Piccadilly

Street Winchester, VA 22601

3/16" = 1'-0" 1E

EXTERIOR ELEVATION 305B - SOUTH

3/16" = 1'-0" 1B

EXTERIOR ELEVATION 305B - NORTH

3/16" = 1'-0" 7D

EXTERIOR ELEVATION 305B - EAST

3/16" = 1'-0" 7E

EXTERIOR ELEVATION 305A - WEST

3/16" = 1'-0" 1C

EXTERIOR ELEVATION 305A - NORTH

3/16" = 1'-0" 1F

EXTERIOR ELEVATION 305A - SOUTH

EXTERIOR ELEVATIONS

AE-201

NOTE:

• TOOTH-IN-BRICK AT MODIFIED OPENINGS

• REPLACE ALL DAMAGED DOWNSPOUTS AND/OR

COLLECTION PIPES

0 - SLAB

0' - 5"

2 - ROOF

12' - 0"

1 - LEVEL 1

3' - 0"

GRADE

0' - 0"

CONTINUOUS MAPLE

VENEER SHELF AT 5'-0"

8'-7" WIDE x 8'-0" TALL x 59.75"

DEEP LEKTREIVER UNITS

PROVIDED AND INSTALLED BY VA

EXTEND STUDS AND CLOSED CELL SPRAY

INSULATION TO ROOF PLANE TO CREATE

COMPLETE INSULATED ENVELOPE (TYPICAL BOTH

ENDS) AND INCLUDE ROOF PLANE OVER MAIN

CORRIDOR

MAPLE VENEER WOOD CAP

SEE DETAIL ON SHEET AE-602

0 - SLAB

0' - 5"

2 - ROOF

12' - 0"

1 - LEVEL 1

3' - 0"

GRADE

0' - 0"

ALIGN SOLARTUBES AS CLOSE AS POSSIBLE TO

MATCH LOCATIONS ON REFLECTED CEILING

PLANS, GIVEN EXISTING TRUSS LOCATIONS

EXTEND STUDS AND CLOSED CELL SPRAY

INSULATION TO ROOF PLANE TO CREATE

COMPLETE INSULATED ENVELOPE (TYPICAL BOTH

ENDS) AND INCLUDE ROOF PLANE OVER MAIN

CORRIDOR

2 - ROOF

12' - 0"

1 - LEVEL 1

3' - 0"

GRADE

0' - 0"

AE-202

8A

SOLARTUBE

BEYOND

PROVIDE AND INSTALL EXTENSION

TUBES AND PITCHED ROOF

CONNECTORS AS NEEDED TO AVOID

STRUCTURAL ELEMENTS. COORDINATE

WITH HVAC AND OTHER TRADES.

STRUCTURAL COLUMNS AND SHEAR

WALLS IN CRAWL SPACE. (SEE

STRUCTURAL DRAWINGS)

0 - SLAB

0' - 5"

2 - ROOF

12' - 0"

1 - LEVEL 1

3' - 0"

GRADE

0' - 0"

EXISTING DOUBLE WYTHE

BRICK WALL

PROTECT EXISTING RIGID

INSULATION TO REMAIN. RE-ATTACH

AND/OR REPLACE AS NECESSARY TO

MAINTAIN INTEGRITY

EXISTING 5 1/2" FIBERGLASS BATT

INSULATION TO REMAIN. REPLACE

AS NECESSARY TO MAINTAIN

INTEGRITY

1" HOLD-OFF BETWEEN NEW STUD &

EXISTING WALL

CLOSED CELL SPRAY FOAM

INSULATION

AE-902

Sim

AE-902

Sim

AE-902

Sim

CLOSED CELL SPRAY FOAM

INSULATION ALONG ENTIRE ROOF

PLANE INCLUDING AREA OVER MAIN

CORRIDOR

INSTALL VAPOR BARRIER

UNDER SILL OF THE NEW

WINDOWS (TYP.)

EXISTING SLAB

NEW METAL STUDS (SEE

STRUCTURAL DRAWINGS)

INTUMESCENT COATING ON ALL

EXPOSED SPRAY FOAM INSULATION

AT CEILING, INSTALL MATCHING WOOD

FURRING WHERE MISSING. SCREW

THROUGH FURRING INTO TRUSS MEMBERS

325 MIGRATION LN., GERRADSTOWN, WV

25420 304-267-2120

PLLC

GROVE & DALL’OLIO

A R C H I T E C T S

11/15/2017 SBP

Comfort Design

Engineers & Electrical

620 Pennsylvania Ave

Winchester, VA 22601

Phone 540-665-2846

Fax 540-667-3284

CD i

FOR CONSTRUCTION

B

A

C

D

E

F

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

305 A/B

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

510 Butler Ave., Martinsburg, WV

ARCHITECT/ENGINEERS/CONSULTANTS:

Building 305A/B Renovations

Martinsburg, WV VAMC

613-15-128 Office of Construction and Facilities Management

LD

Structural Concepts Inc.

132 West Piccadilly

Street Winchester, VA 22601

3/16" = 1'-0" 1A

LONG SECTION - 305B NORTH

3/16" = 1'-0"

LONG SECTION - 305A NORTH

3/16" = 1'-0"

SECTION THROUGH WORK ROOM

1" = 1'-0" 8A

EXTERIOR SIDE WALL SECTION

BUILDING SECTIONS

AE-202

TYP AT ALL EXTERIOR

WALL COVES

3' - 0"

3' - 0"

E Q

E Q

2' - 6"2' - 4"

E Q

E Q

EQ EQ

3' - 7 1/16" EQ EQ

" 1' - 6"1' - 6"

E Q

E Q

2' - 10"2' - 10"

EQ EQ

4' - 6" 4' - 6" 5' - 6"

2' - 0"

EQ EQ

2' - 0"

2' - 6 5/32" 10' - 6 5/32"

2' - 0"

2' - 0"

REPLACE SOFFIT WHERE PIPES

AND CONDUIT WERE REMOVED,

MATCH EXISTING

PREFINISHED WHITE

CEMENTITIOUS FIBER

CEMENT PANELS

5/8" TYPE X GYPSUM

BOARD PANELS AT 9'-0"

2' - 0"

5/8" TYPE X GYPSUM BOARD

PANELS AT 9'-0"

2' X 2' GRID ACOUSTICAL

CEILING TILE (TYP.)

CONTROL JOINT IN GWB

WAP

WAP

UNDERSIDE OF ROOF

E Q

E Q

TYP AT ALL EXTERIOR

WALL COVES

1' - 0 1/4"1' - 0 1/4"

E Q

E Q E Q

E Q

E Q

E Q

E Q

E Q

E Q

E Q

EQ EQ

2' - 0"

2' - 0"2' - 0"2' - 0"

2' - 0"

EQ EQ

E Q

E Q

1' - 9"

1' - 3"

E Q

E Q

5' - 0" 5' - 0" 5' - 0" 5' - 0" 5' - 0" 5' - 0" 5' - 0" 5' - 0" 5' - 0" 5' - 0" 5' - 0" 5' - 0" 4' - 4" 2' - 9"

/2

/2

PREFINISHED WHITE

CEMENTITIOUS FIBER

CEMENT PANELS

CONTINUOUS ACT

EDGE TRIM (TYP)

GWB

5/8" TYPE X GYPSUM

BOARD PANELS AT 9'-0"

CONTROL JOINT

AT GWB

2' X 2' GRID ACOUSTICAL

CEILING (TYP.)

CONTROL JOINT AT GWB

REPLACE SOFFIT WHERE PIPES AND

CONDUIT WERE REMOVED. MATCH

EXISTING IN TERMS OF FINISH,

PATTERN, AND COLOR. (TYP.)

WAP = WIRELESS ACCESS POINT

WAP WAP

325 MIGRATION LN., GERRADSTOWN, WV

25420 304-267-2120

PLLC

GROVE & DALL’OLIO

A R C H I T E C T S

11/15/2017 SBP

Comfort Design

Engineers & Electrical

620 Pennsylvania Ave

Winchester, VA 22601

Phone 540-665-2846

Fax 540-667-3284

CD i

FOR CONSTRUCTION

B

A

C

D

E

F

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

305 A/B

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

510 Butler Ave., Martinsburg, WV

ARCHITECT/ENGINEERS/CONSULTANTS:

Building 305A/B Renovations

Martinsburg, WV VAMC

613-15-128 Office of Construction and Facilities Management

LD

Structural Concepts Inc.

132 West Piccadilly

Street Winchester, VA 22601

3/16" = 1'-0" 2F

REFLECTED CEILING PLAN - 305A

3/16" = 1'-0" 2C

REFLECTED CEILING PLAN - 305B

AE-510

REFLECTED CEILING PLAN

ADJUSTABLE LAMINATE

SHELVES AND SHELF

STANDARDS CAPABLE OF

CARRYING 100LBS/FT

(TYP)

/2

/2

/2

T Y

P

TYP

1' - 2"

GWB CEILING BEYOND

S

IL

L H

E

IG

H T

2' - 0" 3' - 0" 2' - 0"

2"

3' - 2 3/8"

2' - 0" 3' - 0" 2' - 0"

WINDOW OPENING

GYP COVE

2' - 0"

SUSPENDED ACOUSTICAL CEILING

4' - 6"

9'-4"

8'-10"

PORCELAIN TILE

WAINSCOT WITH 3"

BULLNOSE CAP

1' - 6"

T

O S

E A

T

PORCELAIN TILE

WAINSCOT WITH 3"

BULLNOSE CAP

T Y

P

S U

S P

E N

D E

D A

C O

U S

T

IC

A L

C E

IL

IN

G

305A-1

PORCELAIN TILE

WAINSCOT WITH 3"

BULLNOSE CAP

VA PROVIDED AND CONTRACTOR

INSTALLED SOAP DISPENSER

AND PAPER TOWEL DISPENSERS

MIRROR

2' - 6"

T Y

P

G Y

P S

U M

C E

IL

IN

G W

IN

D

O W

C O

V E

S A

N D

O T

H E

R H

A R

D C

E

IL

IN

G

A R

E A

S

GYP COVE

2' - 0"

ADA PROTECTION WRAP

(TYP.)

INSTALL FINISHED TRIM TO MATCH

CEILING GRID TO CLOSE EDGE

OF CEILING (TYP.)

PORCELAIN TILE

WAINSCOT WITH 3"

BULLNOSE CAP

MAPLE VENEER SILL,

TYP.

T

O S

E A

T

TP

GRAB BAR (PROVIDE

BLOCKING TYPICAL NOTE

AT ALL GRAB BARS,

FIXTURES, AND

ACCESSORIES)

S

IL

L H

E

IG

H T

7"

B

T M

O F

T P

TRANSLUCENT GLASS

3' - 6" 1' - 0"

PORCELAIN TILE

WAINSCOT WITH 3"

BULLNOSE CAP

PORCELAIN TILE

WAINSCOT WITH 3"

BULLNOSE CAP

305A-3PORCELAIN TILE

WAINSCOT WITH 3"

BULLNOSE CAP

VA PROVIDED AND

CONTRACTOR INSTALLED

SOAP DISPENSER AND TOWEL

DISPENSERS

MIRROR

2' - 6"

GYP COVE

2' - 0"

T Y

P

G Y

P S

U M

C E

IL

IN

G W

IN

D

O W

C O

V E

S

1' - 6" 1

T

O S

E A

T

2' - 0" MIN. 1' - 0" MIN.

ADA PROTECTION WRAP

(TYP.)

GRAB BAR (PROVIDE BLOCKING

TYPICAL NOTE AT ALL GRAB BARS,

FIXTURES, AND ACCESSORIES)

SEE WALL CARRIER

DETAILS ON SHEET

AE-902

PORCELAIN TILE

WAINSCOT WITH 3"

BULLNOSE CAP

TRANSLUCENT GLASS

T Y

P

S U

S P

E N

D E

D A

C O

U S

T

IC

A L

C E

IL

IN

G

MAPLE VENEER SILL,

TYP.

T O

S E

A T

B

T M

O F

T P

7"

S

IL

L H

E

IG

H T

TP

3' - 6"11 1/4"

"GRAB BAR (PROVIDE

BLOCKING TYPICAL NOTE

AT ALL GRAB BARS,

FIXTURES, AND

ACCESSORIES)

325 MIGRATION LN., GERRADSTOWN, WV

25420 304-267-2120

PLLC

GROVE & DALL’OLIO

A R C H I T E C T S

11/15/2017 SBP

Comfort Design

Engineers & Electrical

620 Pennsylvania Ave

Winchester, VA 22601

Phone 540-665-2846

Fax 540-667-3284

CD i

FOR CONSTRUCTION

B

A

C

D

E

F

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

305 A/B

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

510 Butler Ave., Martinsburg, WV

ARCHITECT/ENGINEERS/CONSULTANTS:

Building 305A/B Renovations

Martinsburg, WV VAMC

613-15-128 Office of Construction and Facilities Management

LD

Structural Concepts Inc.

132 West Piccadilly

Street Winchester, VA 22601

1/2" = 1'-0" 4F

STORAGE ROOM 305B-9 SOUTH

1/2" = 1'-0"

2F

STORAGE ROOM 305B-9 NORTH

1/2" = 1'-0" 1F

KITCHENETTE 305B-8 WEST

1/2" = 1'-0" 7D

WOMEN'S W.C. 305A - WEST

1/2" = 1'-0"

1D

WOMEN'S W.C. 305A - NORTH

1/2" = 1'-0" 3D

WOMEN'S W.C. 305A - EAST

1/2" = 1'-0"

5D

WOMEN'S W.C. 305A - SOUTH

1/2" = 1'-0" 7B

MEN'S WC. 305A - WEST

1/2" = 1'-0"

5B

MEN'S WC. 305A - NORTH

1/2" = 1'-0" 3B

MEN'S WC. 305A - EAST

1/2" = 1'-0"

1B

MEN'S WC. 305A - SOUTH

INTERIOR ELEVATIONS

AE-601

RUBBER BASE

MAPLE VENEER SILL,

TYP.

WINDOW EXTENDS UP INTO

GWB RECESS

RUBBER

BASE

CONTINUOUS MAPLE

VENEER SHELF, SEE

DETAIL 8F,ON THIS

SHEET

6' - 0"

MAPLE VENEER WALL CAP

325 MIGRATION LN., GERRADSTOWN, WV

25420 304-267-2120

PLLC

GROVE & DALL’OLIO

A R C H I T E C T S

11/15/2017 SBP

Comfort Design

Engineers & Electrical

620 Pennsylvania Ave

Winchester, VA 22601

Phone 540-665-2846

Fax 540-667-3284

CD i

FOR CONSTRUCTION

B

A

C

D

E

F

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

305 A/B

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

510 Butler Ave., Martinsburg, WV

ARCHITECT/ENGINEERS/CONSULTANTS:

Building 305A/B Renovations

Martinsburg, WV VAMC

613-15-128 Office of Construction and Facilities Management

LD

Structural Concepts Inc.

132 West Piccadilly

Street Winchester, VA 22601

1/2" = 1'-0" 1F

WORK ROOM 305 A-4 WEST1

1/2" = 1'-0" 1D

WORK ROOM 305 A-4 NORTH1

1/2" = 1'-0"

6D

WORK ROOM 305 A-4 EAST1

AE-602

INTERIOR ELEVATIONS

1/2" = 1'-0" 5F

COPY AREA

6" = 1'-0"

8F

DETAIL OF WOOD CAP

5/8" GWB

3-5/8" METAL STUD WALL,

16" O.C., HELD OFF WALL 1"

4-5/8" CLOSED-CELL SPRAY

URETHANE FOAM INSULATION

EXISTING

BRICK VENEER

EXISTING HOLLOW

CLAY TILE

STRUCTURAL SHEATHING (SEE

STRUCTURAL DRAWINGS)

EXTERIOR CORRIDOR

SURFACE

EXISTING WALL MAY BE

INSULATED

EXISTING WALL

SURFACE

7/8" METAL HAT

CHANNELS 16" O.C.

TYPE X GYPSUM

DRYWALL

EXTEND TO UNDERSIDE

OF ROOF DECK IN

CORRIDORS. IF NEEDED,

INSTALL 5/8" DRYWALL

EACH SIDE

5/8" GWB

3-5/8" METAL STUD

WALL, 16" O.C.

5/8" GWB

3-1/2"

ACOUSTICAL

INSULATION

CUBICLE

PARTITION (NIC)

5/8" GWB

3-5/8" METAL STUD

WALL, 16" O.C.

2 LAYERS

WATER & MOLD

RESISTENT GWB

ON BATHROOM

SIDE

3-1/2" ACOUSTICAL

BATT INSULATION

5/8" GWB

5-5/8" METAL STUD

WALL, 16" O.C.

2 LAYERS

WATER & MOLD

RESISTENT GWB

ON BATHROOM

SIDE

5-1/2" ACOUSTICAL

BATT INSULATION

NOTE: ANY NON-METAL

FRAMING AND BLOCKING NEEDS

TO BE FIRE RATED

A B C D E 1

B

4' - 2 1/2" M.O.

M .O

.A

3' - 4" M.O.

M .O

SH: 39" AFF

Double-Hung

SH: 39" AFF

Double-Hung

2' - 11"

C

Louver

MARBLE THRESHOLD

5"

MARBLE

PORCELAIN

TILE1

/4

M A

X

A B

EXG FLOORING

OR NEW VCT

LUXURY VINYL TILE

VCT OR SHEET FLOORING

TO LUXURY VINYL TILE

5/8" GWB 5/8" GWB

METAL STUDS AND

STRUCTURAL

SHEATHING AS PER

DETAIL ON SHEET S2.1

5/8" GWB

3-5/8" METAL STUD

WALL, 16" O.C.

5/8" GWB

3-1/2" SOUND

ATTENUATION

BLANKETS 20 GAUGE 7/8" DRYWALL

FURRING CHANNEL WITH

HEMMED EDGE

STRUCTURAL

SHEATHING. SEE

STRUCTURAL DRAWINGS

AND NOTES

IB-1 SOUND INSULATION

CLIPS WITH 2" #8 MIN. SHANK

TYPE W BUGLE OR HEX HEAD

SCREWS. MINIMUM PULLOUT

108 POUNDS

3 1/2" WIDE

WOOD STUDS @

16" O.C.

5/8" GWB DESIGNED

FOR USE WITH 25

GAUGE STEEL

FRAMING

3-1/2" SOUND

ATTENUATION

BLANKETS FROM

FLOOR TO CEILING

20 GAUGE 7/8" DRYWALL

FURRING CHANNEL WITH

HEMMED EDGE

IB-1 SOUND INSULATION

CLIPS WITH 2" #8 MIN. SHANK

TYPE W BUGLE OR HEX HEAD

SCREWS. MINIMUM PULLOUT

108 POUNDS

5/8" GWB DESIGNED

FOR USE WITH 25

GUAGE STEEL

FRAMING

325 MIGRATION LN., GERRADSTOWN, WV

25420 304-267-2120

PLLC

GROVE & DALL’OLIO

A R C H I T E C T S

11/15/2017 SBP

Comfort Design

Engineers & Electrical

620 Pennsylvania Ave

Winchester, VA 22601

Phone 540-665-2846

Fax 540-667-3284

CD i

FOR CONSTRUCTION

B

A

C

D

E

F

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

305 A/B

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

510 Butler Ave., Martinsburg, WV

ARCHITECT/ENGINEERS/CONSULTANTS:

Building 305A/B Renovations

Martinsburg, WV VAMC

613-15-128 Office of Construction and Facilities Management

LD

Structural Concepts Inc.

132 West Piccadilly

Street Winchester, VA 22601

1 1/2" = 1'-0"

EXTERIOR WALL

1 1/2" = 1'-0"

1 HR FIRE RATED WALL

1 1/2" = 1'-0"

PARTITION

Door Schedule

To Room: Name From Room: Name Door

Number Width Height Door Type Door Material

Frame Type

Frame Material

Fire Rating Saddle HW Comments

FISCAL 305B-1A 3' - 0" 6' - 8" EXG HM EXG HM E-1

HALL 305A-8 3' - 10 1/2" 7' - 0" A Aluminum Clad Wood EXG HM E-1 tinted glazing

FISCAL ENTRY FOYER 305B-1B 3' - 0" 7' - 0" C Maple Veneer 1 HM 45 MIN B SH-4

CONFERENCE FISCAL 305B-4 3' - 0" 7' - 0" B Maple Veneer 1 HM 3E

FINANCE CHIEF FISCAL 305B-5 3' - 0" 7' - 0" B Maple Veneer 1 HM 3E

FISCAL CHIEF OF SERVICE 305B-3 3' - 0" 7' - 0" B Maple Veneer 1 HM 3E

ACCTG CHIEF FISCAL 305B-6 3' - 0" 7' - 0" B Maple Veneer 1 HM 3E

FISCAL STORAGE 305B-9 3' - 0" 7' - 0" B Maple Veneer 1 HM 5

ENTRY FOYER MECH RM 305B-2 3' - 0" 7' - 0" EXG Maple Veneer 1 HM 45 MIN B 5

VESTIBULE ENTRY FOYER 305A-2 3' - 0" 7' - 0" C Maple Veneer 1 HM 45 MIN B SH-4

WORK ROOM CL WORK ROOM 305A-4A 5' - 0" 7' - 0" B Maple Veneer 1 HM 11

HALL PAYROLL 305A-12 3' - 0" 7' - 0" B Maple Veneer 1 HM 3E

HALL PAYROLL 305A-11 3' - 0" 7' - 0" B Maple Veneer 1 HM 3E

CORRIDOR FILE RM. 305A-9 3' - 0" 7' - 0" B Maple Veneer 1 HM 5

CORRIDOR PAYROLL 305A-10 3' - 0" 7' - 0" B Maple Veneer 1 HM 3E

VESTIBULE MEN W.C. 305A-3 3' - 0" 7' - 0" B Maple Veneer 1 HM A 4B

WORK ROOM CL WORK ROOM 305A-4B 5' - 0" 7' - 0" B Maple Veneer 1 HM 11

VESTIBULE CORRIDOR 305A-13 3' - 0" 7' - 0" C Maple Veneer, Glazed 1 HM 45 MIN B SH-4

WORK ROOM VESTIBULE 305A-4 3' - 0" 7' - 0" C Maple Veneer, Glazed 1 HM SH-4

PAYROLL CORRIDOR 305A-7 3' - 0" 7' - 0" B Maple Veneer 1 HM 3E

ENTRY FOYER MECH. RM. 305A-5A 3' - 0" 7' - 0" B HM 1 HM 45 MIN B 5

VESTIBULE WOMEN W.C. 305A-1 3' - 0" 7' - 0" B Maple Veneer 1 HM A 4B

ENTRY FOYER MECH. RM. 305A-5B 3' - 0" 6' - 8" EXG EXG EXG 45 MIN B 5

ENTRY FOYER BIOMED CL 305A-14 6' - 0" 7' - 0" B Maple Veneer 1 HM 45 MIN B 11

1 1/2" = 1'-0"

6'-0" CUBICLE PARTITION BY VA (NIC)

1 1/2" = 1'-0" 3A

NON-PLUMBING RESTROOM PARTITION

1 1/2" = 1'-0"

PLUMBING RESTROOM PARTITION

1/4" = 1'-0" Door Types

1/4" = 1'-0" Frame Types

Finish Schedule

Number Name Floor Finish Base Finish

North Wall Finish East Wall Finish South Wall Finish West Wall Finish

Ceiling Finish

Ceiling Height Remarks

305A ENTRY FOYER EXISTING RB MATCH

EXG

MATCH EXG MATCH EXG MATCH EXG MATCH

EXG

7'-4"

305A-1 WOMEN W.C. 12" X 12"

PORCELAIN TILE

PTL P4/PTL P4/PTL P4/PTL P4/PTL P6/ACT 9'-0"/8'-6"

305A-2 VESTIBULE LUXURY VINYL

TILE

RB P3 P4 P4 P4 P6/ACT 9'-0"/8'-6"

305A-3 MEN W.C. 12" X 12"

PORCELAIN TILE

PTL P4/PTL P4 P4 P4 P6/ACT 9'-0"/8'-6"

305A-4 WORK ROOM LUXURY VINYL

TILE

RB P1 P4 P4 P4 P6/ACT 9'-0"/8'-6"

305A-5 MECH. RM. 12" X 12" VCT RB P4 P4 P4 P4 P6 9'-0"

305A-7 PAYROLL CARPET TILE RB P4 P1 P4 P4 P6/ACT 9'-0"/8'-6"

305A-8 HALL LUXURY VINYL

TILE

RB P1/P4 P2/P4 P4 P4 P6/ACT 9'-0"/8'-6"

305A-9 FILE RM. CARPET TILE RB P4 P1 P4 P4 P6/ACT 9'-0"/8'-6"

305A-10 PAYROLL CARPET TILE RB P4 P3 P4 P4 P6/ACT 9'-0"/8'-6"

305A-11 PAYROLL CARPET TILE RB P4 P4 P4 P3 P6/ACT 9'-0"/8'-6"

305A-12 PAYROLL CARPET TILE RB P4 P4 P4 P1 P6/ACT 9'-0"/8'-6"

305A-13 CORRIDOR LUXURY VINYL

TILE

RB P4 P4 P2 P4/P2 P6/ACT 9'-0"/8'-6"

305A-14 BIOMED CL 12" X 12" VCT RB P4 P4 P4 P4 P6 9'-0"

305A-CL WORK ROOM CL LUXURY VINYL

TILE

RB P4 P4 P4 P4 P6 9'-0"

305B-1 FISCAL LUXURY VINYL

TILE

RB P1/P4 P4/P2 ON DIVIDER

WALL

P4/P2 ON DIVIDER

WALL

P4/P2 ON DIVIDER

WALL

P6 9'-0"

305B-1A RECEP. CARPET TILE RB P4 P4 N/A P1 P6/ACT 9'-0"/8'-6"

305B-2 MECH RM 12" X 12" VCT RB P4 P4 P4 P4 P6/ACT 9'-0"/8'-6"

305B-3 CHIEF OF

SERVICE

CARPET TILE RB P4 P4 P4 P1 P6/ACT 9'-0"/8'-6"

305B-4 CONFERENCE CARPET TILE RB P4 P3 P4 P4 P6/ACT 9'-0"/8'-6"

305B-5 FINANCE CHIEF CARPET TILE RB P4 P1 P4 P4 P6/ACT 9'-0"/8'-6"

305B-6 ACCTG CHIEF CARPET TILE RB P4 P3 P4 P4 P6 9'-0"/8'-6"

305B-7A ACCTG. TECH. CARPET TILE RB P4 N/A N/A P4 P6 9'-0"/8'-6"

305B-7B ACCT. CARPET TILE RB P4 N/A N/A N/A P6/ACT 9'-0"/8'-6"

305B-7C ACCT. CARPET TILE RB P4 N/A N/A N/A P6/ACT 9'-0"/8'-6"

305B-7D BUDGET AN. CARPET TILE RB P4 P4 N/A N/A P6/ACT 9'-0"/8'-6"

305B-7E VOUCHER EXAM CARPET TILE RB N/A N/A P4 N/A P6/ACT 9'-0"/8'-6"

305B-7F INTERN CARPET TILE RB N/A N/A P4 N/A P6/ACT 9'-0"/8'-6"

305B-7G INTERN CARPET TILE RB N/A N/A P4 N/A P6/ACT 9'-0"/8'-6"

305B-7H FINAN. TECH. CARPET TILE RB N/A P4 P4 N/A P6/ACT 9'-0"/8'-6"

305B-8 K'ETTE LUXURY VINYL

TILE

RB P4 N/A P4 P2 P6/ACT 9'-0"/8'-6"

305B-9 STORAGE 12" X 12" VCT RB P4 P4 P4 P4 P6/ACT 9'-0"/8'-6"

Window Schedule

Des.

Masonry Opening New/Existing Muntins Tinting Low E Remarks/Options

A 3'-4" x 6'-2" New None Yes Fiberglass Composite Frame

B 4'-2 1/2" x 6'-2" New None On South Facade Only Yes Fiberglass Composite Frame

C New None N/A N/A 35" X 22" Louver - see mech.

1/4" = 1'-0" Window Types

DOOR, WINDOW & FINISH

SCHEDULE & PARTITION TYPES

AE-901

RB = RUBBER BASE

RT = RESILIENT TILE

VCT = VINYL COMPOSITION TILE

PTL = PORCELAIN TILE

ACCENT PAINT LEGEND

P1 - MILK AND HONEY AF210

P2 - KALAMATA AF630

P3 - PASHMINA AF100

P4 - MASCARPONE AF20 (MAIN WALLS)

P5 - PASHMINA AF100

P6 - COLLECTOR'S ITEM AF45

NOTE: PRIVACY GLAZING IN BATHROOMS

3" = 1'-0" Saddle Types

1 1/2" = 1'-0"

SHEAR WALL PARTITION

1 1/2" = 1'-0"

6B

SHEAR WALL PARTITION 2

1 1/2" = 1'-0"

ACOUSTICAL PARTITION

ALL DOOR FRAMES AND HOLLOW METAL DOORS TO BE PAINTED P5

*MATCH EXISTING DOOR HEIGHT

REFER TO SPECIFICATIONS FOR HARDWARE REQUIREMENTS

Inner Dome

Roof Rafter

Extension Tube

Bottom 0-30º angle adapter tube

Butterfly Baffle

Daylight Dimmer Housing

Top 0-30º angle adapter tube

Square/Round Transition and clip

Drywall Ceiling

Diffuser

1'-9 1/2"

2'

/4

325 MIGRATION LN., GERRADSTOWN, WV

25420 304-267-2120

PLLC

GROVE & DALL’OLIO

A R C H I T E C T S

11/15/2017 SBP

Comfort Design

Engineers & Electrical

620 Pennsylvania Ave

Winchester, VA 22601

Phone 540-665-2846

Fax 540-667-3284

CD i

FOR CONSTRUCTION

B

A

C

D

E

F

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

305 A/B

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

510 Butler Ave., Martinsburg, WV

ARCHITECT/ENGINEERS/CONSULTANTS:

Building 305A/B Renovations

Martinsburg, WV VAMC

613-15-128 Office of Construction and Facilities Management

LD

Structural Concepts Inc.

132 West Piccadilly

Street Winchester, VA 22601

SKYLIGHT TUBES & WINDOW

DETAILS

AE-902

1 1/2" = 1'-0"

NEW DAYLIGHTING TUBE DETAIL

INTERLOCKER (TYP)

6" = 1'-0"

NEW FIBERGLASS WINDOW HEAD (TPY)

6" = 1'-0"

NEW FIBERGLASS WINDOW SILL (TYP)

6" = 1'-0"

NEW FIBERGLASS WINDOW

INTERLOCKER (TYP)

Self sealing flexible weather barrier membrane and flashing as par manufacturers instructions on all 4 sides

TOILET CARRIER DETAIL PLAN VIEW

NTS

TOILET CARRIER ELEVATION

NTS

Architectural
Architectural