This is a Statement of Work (SOW) for the procurement of a comprehensive inhalation exposure system for the VA Pittsburgh Healthcare System (VAPHS) Research Office Building. The Department of Veterans Affairs Network Contracting Office, located in Pittsburgh, PA (zip code 15240), issued this special notice solicitation numbered 36C24426Q0937 with a response deadline of September 3, 2026 at 4:00 PM Eastern Time. The contracting officer is Andrew Taylor (andrew.taylor3@va.gov, 724-841-7191). The product service code is 6515 (Laboratory Analytical Instruments) and the NAICS code is 541714 (Research and Development in Biotechnology).

The contractor must design, construct, and install a modular inhalation exposure system capable of supporting controlled experimental exposure studies with aerosolized particulates, vapors, and gaseous agents for both in vivo animal models (up to 12 rats or 36 mice) and in vitro cellular systems. The system deliverables include 19 major components and subsystems, encompassing the base toxicant exposure chamber with integrated environmental controls, multiple aerosol and vapor generators (including dry powder, liquid, jet fuel combustion, and e-cigarette vape generators), custom stainless-steel animal cages, cell exposure modules, and supporting equipment. The contractor must perform complete on-site installation with full system validation, provide three days of comprehensive on-site training with unlimited remote support, deliver complete technical documentation, and maintain an annual service contract with four scheduled preventative maintenance visits per year. The period of performance is six months from award, with all on-site work restricted to business hours (8:00 AM-5:00 PM EST, Monday-Friday) and contractor personnel required to comply with VA security, identification, and smoking policies.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SUBJECT*

Inhalation Exposure System Pittsburgh Research (PACT Act)

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
15240
SOLICITATION NUMBER*
36C24426Q0937
RESPONSE DATE/TIME/ZONE
09-03-2026 4:00 PM EASTERN TIME, NEW YORK, USA
ARCHIVE
10 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N
PRODUCT SERVICE CODE*
6515
NAICS CODE*
541714
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

Network Contracting Office 4 1010 Delafield Road Pittsburgh PA 15240

POINT OF CONTACT*

Contracting Officer Andrew Taylor andrew.taylor3@va.gov 724-841-7191

ADDITIONAL INFORMATION

AGENCY’S URL
https://www.va.gov/pittsburgh-health-care/
URL DESCRIPTION
VA Pittsburgh Healthcare
AGENCY CONTACT’S EMAIL ADDRESS
andrew.taylor3@va.gov
EMAIL DESCRIPTION
Contracting Officer

DESCRIPTION

Special Notice Special Notice See attached document: 12.102 Restricting Competition Acquisitions SAT26_Redacted.

*= Required Field
Special Notice

Special Notice

STATEMENT OF WORK

Contract Title:

IEStechno Exposure System Purchase Contract at VA Pittsburgh Healthcare System (VAPHS).

Background:

The VA Pittsburgh Healthcare System (VAPHS) is in need of an inhalation exposure system to support controlled experimental exposure studies involving aerosolized particulates, vapors, and gaseous agents. The system shall be designed to enable reproducible delivery of defined aerosolized or gaseous exposures to in vivo animal models and in vitro cellular systems under controlled laboratory conditions. This shared research resource will enhance the capability of investigators at VAPHS to conduct translational and preclinical studies related to respiratory health, toxicology, military exposure research, environmental exposure science, and related biomedical research areas.

Scope:

The Contractor shall construct and install a modular inhalation exposure system capable of providing reliable and reproducible exposure conditions suitable for a variety of inhalation research applications, including aerosolized particulates, vapors, and gaseous agents, while supporting appropriate environmental control, monitoring, and safety requirements. The inhalation exposure system shall be capable of supporting both in vivo animal models and in vitro cellular, as required by specific study designs, as well as include integrated controls for airflow, temperature, humidity, aerosol/gas concentration monitoring, and exposure duration. The system shall also incorporate multiple engineering and procedural safety features intended to minimize risk and ensure compliance with institutional safety standards.

Deliverables/Technical Requirements The inhalation exposure system shall include:

1. Base Toxicant Inhalation Exposure System (BExp1): This system includes:

· Cube 150 Stainless-Steel Exposure Chamber to hold up to 12 rats or 36 mice

· Air-cleaning System Module (pressure regulator, air dryer, carbon filter and HEPA filter)

· Generator Mass Flow Controller

· Diluent Mass Flow Controller

· Gravimetric Sampling Mass Flow Controller

· Mass Flow Controller Hub

· Temperature and Humidity Probe

· CO2 Monitor

· USB Hub

· 24 Volt Power Supply

· Exhaust Mass Flow Controller

· Exhaust HEPA Filter with Housing

· Exhaust Activated Carbon Filter with Housing

· Generator Pressure Transducer

· Exposure Chamber Pressure Transducer

· Custom Stainless-Steel Aerosol and Gas Disperser

· Light Scattering Device that estimates the real-time mass concentration of the aerosols in the exposure chamber

· Photo Ionization Detector to estimate the real-time volatile organic compound gas levels in the exposure chamber

· Emergency Shut Down Button

· Multi-function input/output board that interfaces with the computer to digitize analog signals

· Laptop computer

· Custom Base Software that acts as a graphical user interface to monitor, control and record exposure variables

· All associated cables and tubing -Instruction manual

2. Low-Noise Exhaust Vacuum Pump with Sound Shield (VPump)

3. Automatic Super Humidifier Controller for the Toxicant Inhalation Exposure System (HumLab1):

4. Cell Exposure System (CellExpo1):

5. Dry Powder Acoustical Aerosol Generator (HP AG):

6. Small High Pressure Acoustical Generator (HP-AG-0.5):

7. High Pressure Nebuilzer Liquid Aerosol Generator (Neb1):

8. Jet Fuel Liquid Combustion Generator (LiqComG…):

9. Modification to allow Jet Fuel Liquid Combustion Generator to also function as a Heated Vapor Generator (VapMod1):

10. E-Cig Puff Vape Generator (Puff):

11. Base Control Inhalation Exposure System (Expo1):

12. Automatic Control Inhalation Exposure System (AutoCon):

13. Heating and Cooling System for the Control Inhalation Exposure Systemm(ChHeCo2):

14. Automatic Super Humidifier Controller for the Control Inhalation Exposure System (HumLab1):

15. Custom Stainless Steel Mouse Cage for 36 Individually Housed Mice (MCAGE1):

16. Custom Stainless Steel Rat Cage for 12 Individually Housed Rats (RCAGE1):

17. System installation at customer site (INST1):

18. System use training (TRN1):

19. Annual Service Contract (ServQuad): Contractor Requirements:

System Delivery and Installation The Contractor shall deliver all system components to the designated laboratory site and perform complete installation. Installation shall include assembly, integration of modules, connection to facility utilities as required, and verification of full system functionality and operational readiness.

1. System Validation and Performance Verification The Contractor shall perform full system validation, including: functional verification of all system components; calibration of sensors and monitoring devices; validation of aerosol, gas, and vapor generation performance; confirmation of exposure control stability and reproducibility; and demonstration of proper operation of all safety and control systems

2. Training Requirements The Contractor shall provide comprehensive on-site training for end users. Training shall include three (3) full days of instruction covering system operation, maintenance, safety procedures, troubleshooting, and data acquisition/analysis. Unlimited remote support (email and telephone) shall also be provided.

3. Preventative Maintenance and Service Support The Contractor shall provide an annual service agreement including four (4) scheduled on-site maintenance visits per year. During each visit, preventative maintenance will be performed including filter replacement, sensor calibration, replacement of disposable parts showing wear, and updates/tuning of exposure control systems. Any equipment issues or failures will be identified during these visits; however, the cost of replacing any damaged or non-functional equipment will be the responsibility of the Customer.

4. Documentation Requirements The contractor shall provide full system documentation, including operation manuals, maintenance procedures, calibration protocols, and software user guides.

5. Safety and Compliance The system shall comply with applicable institutional, occupational, and laboratory safety standards and regulations. The Contractor shall ensure the system is suitable for operation in controlled inhalation exposure research environments involving aerosols, gases, vapors, and other experimental toxicants.

Other Requirements

1. Service Hours

a. The Contractor shall provide all required “on-site” services within the normal business hours (8:00 AM to 5:00 PM (EST) M-F), excluding holidays. Work performed outside the normal hours of coverage must be pre-approved by the Technical POC.

b. The Contractor representatives must be escorted at all times while on VA premises.

2. Identification and Parking

a. A compliant ID badge must be worn by the Contractor representatives at all times while on VA premises.

b. It is the responsibility of the Contractor to park in the appropriate designated parking areas. Information on parking is available from the VA Police-Security Service. VAPHS will not invalidate or make reimbursement for parking violations of the contractor under any conditions.

3. Smoking

a. All VA Pittsburgh property is smoke-free. Contractor personnel will comply with VA Pittsburgh smoking policies. Violations will result in a warning and possible citation.

Period of Performance: Six (6) months from date of award Place of Performance:

VA Pittsburgh Healthcare System (VAPHS) Research Office Building B30 4071-4089 University Dr. C Pittsburgh, PA 15219

End of Document

File details come from the government source that posted it. Updated .