36C24426Q0405_1.docx

DOCX document 34 KB Posted

Attached to
6515--Aspen Total Joint Program (Brand Name or Equal to)
Solicitation number
36C24426Q0405
Issued by

About this file

This is a Presolicitation Notice for the procurement of orthopedic surgical instruments to support the Erie VA Medical Center's Total Joint Initiative. The Department of Veterans Affairs, Veterans Health Administration, Veterans Integrated Service Network 4 is seeking brand name or equal to Aspen Surgical "Symmetry" orthopedic instruments to support shoulder, knee, and hip total joint replacement procedures. The solicitation number is 36C24426Q0405, with a response deadline of April 21, 2026 at 4:00 PM Eastern Time. The place of performance is the Erie VA Medical Center located at 135 East 38th Street, Erie, PA 16504. The contracting office is the Department of Veterans Affairs Network Contracting Office in Pittsburgh, PA, with Contracting Officer Andrew Taylor serving as the point of contact.

The procurement requires 30 orthopedic instruments across various types including osteotomes, elevators, retractors, forceps, curettes, rongeurs, drivers, hooks, and a mallet, with quantities ranging from 4 to 8 units per instrument type. All instruments must be reusable, constructed of surgical-grade stainless steel, and compatible with existing sterilization methods, particularly moist heat steam sterilization, as well as manual and ultrasonic cleaning processes used by the facility's Sterile Processing Services. Instruments must meet FDA, AAMI ST79, and AAMI ST81 standards and maintain dimensional and functional equivalence to the Aspen Surgical Symmetry reference brand. Delivery is required on a FOB Destination basis within 30 days after receipt of order to the Erie VA Medical Center Distribution Center, Monday through Friday between 8:00 AM and 4:00 PM. The Product Service Code is 6515, and the NAICS Code is 339113.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SUBJECT*

Aspen Total Joint Program (Brand Name or Equal to)

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
16504
SOLICITATION NUMBER*
36C24426Q0405
RESPONSE DATE/TIME/ZONE
04-21-2026 4:00 PM EASTERN TIME, NEW YORK, USA
ARCHIVE
10 DAYS AFTER THE RESPONSE DATE

SET-ASIDE

PRODUCT SERVICE CODE*
6515
NAICS CODE*
339113
PLACE OF PERFORMANCE
Erie VA Medical Center

135 East 38th Street

Erie PA

POSTAL CODE
16504

COUNTRY

CONTACT INFORMATION

CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

Network Contracting Office 4

1010 Delafield Road Pittsburgh PA 15240

POINT OF CONTACT*

Contracting Officer Andrew Taylor andrew.taylor3@va.gov 724-679-2327

ADDITIONAL INFORMATION

AGENCY’S URL
https://www.va.gov/erie-health-care/
URL DESCRIPTION
Erie VA medical Center
AGENCY CONTACT’S EMAIL ADDRESS
andrew.taylor3@va.gov
EMAIL DESCRIPTION
Contracting Officer

Presolicitation Notice Presolicitation Notice

DESCRIPTION

*=Required Field
Presolicitation Notice

Presolicitation Notice

Aspen Surgical “Symmetry” Orthopedic Instruments Brand Name or Equal

Background: The Department of Veterans Affairs, Erie, PA VA Medical Center, Surgical department is implementing a Total Joint Initiative to expand and sustain its ability to perform shoulder, knee, and hip surgeries in house. This initiative supports the delivery of comprehensive orthopedic care, improves access for Veterans, and reduces reliance on community care. As part of this initiative, the Erie, PA VA Medical Center has already invested in standardized surgical platforms and equipment, including powered surgical instruments, to ensure consistency, interoperability, and operational readiness within the Surgery department. These investments were made to establish a reliable, system-based approach to Total Joint replacement procedures.

To fully support the Total Joint Initiative, our Surgery department requires the acquisition of reusable orthopedic surgical instruments necessary to assemble standardized instrument trays for use during shoulder, knee, and hip total joint procedures. These instruments must be suitable for repeated use in a high-volume surgical environment and compatible with existing VA sterilization and operating room procedures.

Scope of Work: The Erie, PA VA Medical Center requires the procurement of brand name or equal to Aspen Surgical “Symmetry” orthopedic instruments to support our newly established Total Joint Initiative. The instruments shall be suitable for inclusion in standardized orthopedic instrument trays and must be compatible with existing operating room workflows, sterilization methods, and clinical practices at the Erie, PA VA Medical Center.

Brand name requirement (Brand Name or Equal): Aspen Surgical “Symmetry” Orthopedic Instruments

#
Part #
Description
Qty
1
32-3423
Symmetry Hook; Bone; Sharp; Heavy Duty; 19 mm Diameter; 9 in; 228 mm
4
2
28-9406
Symmetry Osteotome; Lambotte; Straight; 1/4 in; 9 in; 228 mm
4
3
28-9420
Symmetry Osteotome; Lambotte; Straight; 3/4 in; 9 in; 228 mm
4
4
28-9425
Symmetry Osteotome; Lambotte; Straight; 1 in; 9 in; 228 mm
4
5
28-9430
Symmetry Osteotome; Lambotte; Straight; 1 1/4 in; 9 in; 228 mm
4
6
28-9440
Symmetry Osteotome; Lambotte; Straight; 1 1/2 in; 9 in; 228 mm
4
7
28-9456
Symmetry Osteotome; Lambotte; Curved; 1/4 in; 9 in; 228 mm
4
8
28-9462
Symmetry Osteotome; Lambotte; Curved; 1/2 in; 9 in; 228 mm
4
9
28-9470
Symmetry Osteotome; Lambotte; Curved; 3/4 in; 9 in; 228 mm
4
10
28-9475
Symmetry Osteotome; Lambotte; Curved; 1 in; 9 in; 228 mm
4
11
28-9480
Symmetry Osteotome; Lambotte; Curved; 1 1/4 in; 9 in; 228 mm
4
12
28-9490
Symmetry Osteotome; Lambotte; Curved; 1 1/2 in; 9 in; 228 mm
4
13
65-2512
Symmetry Elevator; Key; 1/2 in Blade Width; 7 1/2 in; 190 mm
4
14
65-2513
Symmetry Elevator; Key; 3/4 in Blade Width; 7 1/2 in; 190 mm
4
15
55-7025
Symmetry Elevator; Freer; Sharp/Blunt; 4.5 mm Width; Double-Ended; 7 1/2 in; 190 mm
4
16
77-1168
Symmetry Retractor; Hohmann; 22 mm Wide
4
17
77-1118
Symmetry Retractor; Hohmann; 18 mm Wide; w/Finger Ring; 9 1/2 in
4
18
30-4088
Symmetry Forceps; Lahey Goitre Tenaculum; 6 1/4 in
8
19
29-8819A
Symmetry Curette; Cobb; Angled; Size 00; w/Round Handle; 11 in; 279 mm
4
20
29-8820A
Symmetry Curette; Cobb; Angled; Size 0; w/Round Handle; 11 in; 279 mm
4
21
29-8821A
Symmetry Curette; Cobb; Angled; Size 1; w/Round Handle; 11 in; 279 mm
4
22
29-8824A
Symmetry Curette; Cobb; Angled; Round Handle; Size 4; 11 in; 279 mm
4
23
46-3028
Symmetry Driver; Cervical Graft; Unguarded
4
24
31-5105
Symmetry Rongeur; Leksell; 5 mm; Slightly Curved Handle; 9 in; 228 mm
4
25
65-2546
Symmetry Elevator; Cobb Spinal; 1/2 in Blade Width; 11 in; 279 mm
4
26
65-2547
Symmetry Elevator; Cobb Spinal; 3/4 in Blade Width; 11 in; 279 mm
4
27
28-7030
Symmetry Osteotome; Cobb; Curved; 5/8 In Wide; 11 in
4
28
46-2011
Symmetry Osteotome; Curved; 3/8
4
29
46-2506
Symmetry Osteotome; Smith-Peterson; Straight; 1 1/4 in
4
30
27-0401
Symmetry Mallet; 1 1/2 in Head; 2 lbs. Weight; 7 1/2 in; 190 mm
4

Salient Characteristics:

The following salient characteristics for the orthopedic surgical instruments must meet all of the following to be considered technically acceptable. These characteristics represent the minimum needs of the Erie, PA VA Medical Center’s Total Joint Program and are required to support shoulder, knee, and hip joint replacement procedures.

Functional Equivalence – Instruments must be functionally equivalent to the reference brand name items and capable of performing the same surgical tasks in shoulder, knee, and hip total joint procedures. The instruments must be appropriate for:

· bone cutting and resection

· bone manipulation and exposure

· retraction and tissue handling

· malleating and impaction Dimensional and Design Equivalence – Instruments must be dimensionally comparable to the referenced items including:

· Comparable blade widths, lengths, and curvatures

· Comparable working end geometry Minor dimensional variations are acceptable provided they do not affect surgical function or tray compatibility.

Materials and Construction – Instruments must be constructed of surgical grade materials, such as stainless steel, suitable for orthopedic surgical use. Construction must support repeated use in a high-volume surgical environment. Instruments must be free of manufacturing defects and finished to standards appropriate for surgical instrumentation. These instruments must be intended for reusable surgical use and comply with all applicable FDA, AAMI, and VA standards.

· AAMI ST79

· AAMI ST81

Sterile Processing and Reprocessing Compatibility – Instruments must be compatible with existing Erie, PA VAMC, Sterile Processing Services (SPS) workflows. Instruments must be compatible with moist heat (steam) sterilization, which is the standard sterilization method used by the Erie, PA VAMC. Instruments must be capable of being:

· Manually cleaned

· Ultrasonically cleaned

· Processed in automated washer and disinfectors

· Suitable for use in wrapped trays or rigid containers Instrument design must allow effective cleaning of hinges, joints, crevices, and working surfaces.

Security & Privacy:

The vendor will not be on station therefore the Certification & Accreditation (C&A) requirements of VHA Handbook 6500.6 do not apply to this requirement; therefore, a Security Accreditation package is not required. No C&A or MOU/ISA is required. Sensitive information exposure as part of this contract involves applicable security controls within the facility as part of the VA Information Security Program. If there are any questions related to privacy, please have a member of your staff contact the VA Privacy Service at 202-461-6309. If there are any questions related to information security, please have a member of your staff contact the Office of Cyber Security at 304-262-7733.

Delivery:

All items must be FOB Destination, 30 Days ARO, to the following location:

Erie VA Medical Center Attn: Distribution Center 135 E. 38th Street Erie, PA 16504

Monday – Friday from 8:00am – 4:00pm End of Document Page 1 of

File details come from the government source that posted it. Updated .