This is a Sources Sought Notice for Preventative Maintenance and Repair (PM&R) services for Ameriwater brand Reverse Osmosis equipment at the Altoona VA Medical Center in Pennsylvania. The Department of Veterans Affairs is seeking qualified vendors to provide quarterly, semi-annual, and annual maintenance services for a specific Reverse Osmosis System (ROS 800 GPD) with Deionozer and Storage Tank. The procurement will use NAICS code 811210 with a small business size standard of $34 million, and the period of performance spans a base year from 12/03/2025-12/02/2026 with four potential one-year option periods extending through 12/02/2030.

Interested vendors must submit responses via email to Emily Hall (emily.hall5@va.gov) by 10:00 am ET on November 14, 2025, including company details, SAM UEI, contact information, capabilities, and socio-economic status. Required services include system inspections, membrane performance monitoring, equipment functioning verification, carbon filter replacements, disinfection procedures, and provision of specific parts such as carbon cartridges, anti-scalant, and deionization resin packs. Vendors must be registered in SAM and, if applicable, verified in VetBiz.gov for Service-Disabled Veteran Owned Small Businesses (SDVOSB) or Veteran Owned Small Business (VOSB) status.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sources Sought Notice Sources Sought Notice

SUBJECT*
Altoona VAMC | PM&R - Reverse Osmosis

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
15215
SOLICITATION NUMBER*
36C24426Q0079
RESPONSE DATE/TIME/ZONE
11-14-2025 10:00 EASTERN TIME, NEW YORK, USA
ARCHIVE
60 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N

SET-ASIDE

PRODUCT SERVICE CODE*
J046
NAICS CODE*
811210
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

Network Contracting Office 4 Services 3 1010 Delafield Road Pittsburgh, PA 15215-1802

POINT OF CONTACT*

Contract Specialist Emily Hall emily.hall5@va.gov 412-791-3009

PLACE OF PERFORMANCE

ADDRESS
Department of Veterans Affairs

Altoona VA Medcial Center

2907 Pleasant Valley Boulevard

Altoona PA

POSTAL CODE
16602-4305
COUNTRY
USA

ADDITIONAL INFORMATION

AGENCY’S URL
http//www.va.gov
URL DESCRIPTION
web address
AGENCY CONTACT’S EMAIL ADDRESS
emily.hall5@va.gov
EMAIL DESCRIPTION
Contract Specialist's email address

DESCRIPTION

This is a SOURCES SOUGHT NOTICE only. Responses to this notice will be used for information and planning purposes. No quotes are being requested or accepted at this time with this notice.

The Department of Veteran’s Affairs, Altoona Medical Center, Altoona, PA 16602, has a requirement for Preventative Maintenance and Repair (PM&R) for Ameriwater brand SPD Reverse Osmosis equipment.

The North American Industry Classification System (NAICS) code being considered for this procurement is 811210, Electronic Precision and Equipment Repair and Maintenance, and the Product Service Code (PSC) is J064 Maintenance, Repair, and Rebuilding Equipment-Water Purification and Sewage Treatment Equipment. The Small Business Size Standard is $34 million. Responses to this notice should include the following:

1. Company name

2. SAM UEI

3. Company’s address

4. Point of Contact Information (i.e., title, phone number, and email address)

5. Company’s capability to meet this requirement and any pertinent information which demonstrates the company’s ability to meet the above requirement.

6. GSA Federal Supply Schedule contract number or other applicable contract vehicle contract number, if within scope of this effort (if applicable).

7. Company’s type of business (small or large)

8. Socio-economic status If applicable, Service-Disabled Veteran Owned Small Businesses (SDVOSB) and Veteran Owned Small Business (VOSB) must be verified in www.VetBiz.gov. Responses should provide enough information to determine if the vendor can comply with the limitations on subcontracting as defined in VAAR 852.219-74 and all applicable CFR references where applicable.

All responses shall be in writing via email no later than 10:00 am (ET) November 14, 2025, to Emily Hall at emily.hall5@va.gov.

Facsimile or telephone responses will not be accepted. There will be no question-and-answer period for this sources sought.

Simply responding as an “interested party” does constitute your company as a source. Offeror must provide the above requested information. After reviewing the responses to this sources sought notice, a solicitation announcement may be published on the SAM or GSA website in the near future. Responses to this sources sought announcement are not considered adequate responses to the solicitation announcement. All interested offerors will have to respond to the forthcoming solicitation announcement, in addition to responding to this sources sought notice. All interested parties must be registered with System for Award Management (SAM) at https://www.sam.gov in order to be eligible for award of Government contracts.

Statement of Need

Background: The Altoona VA Medical Center wishes to procure a PM&R service contractor for SPD Reverse Osmosis equipment. All necessary labor must be performed by an authorized Ameriwater Service Provider capable of providing materials, equipment, parts and travel to perform inspections on the AMERIWATER ROS 800 GPD REVERSE OSMOSIS SYSTEM with Deionozer and Storage Tank (00HC-2050) at the James E. Van Xandt VA Medical Center, 2907 Pleasant Valley Boulevard, Altoona, PA 16602.

PERIOD OF PERFORMANCE: Base Plus 4 one-year option periods Base Year: 12/03/2025-12/02/2026 Option Year 1: 12/03/2026-12/02/2027 Option Year 2: 12/03/2027-12/02/2028 Option Year 3: 12/03/2028-12/02/2029 Option Year 4: 12/03/2029 – 12/02/2030

QUARTERLY SERVICE:

-Inspect System for Leaks -Verify Proper Functioning of RO Gauges &Instrumentation -Monitor RO Membrane Performance -Verify Proper Functioning of Storage Tank System/ Level Controls -Verify Proper Functioning of Distribution Pump System -Verify Proper Functioning of Anti-Scalant Feed System -Replace two Ameriwater Carbon Block Filter Cartridges 2.5" x 20"10 micron -Check and Fill Antiscalant. Use customer stock to refill.

-RO Cleaning/Disinfection

SEMI-ANNUAL SERVICE TO INCLUDE:

-Minncare disinfection of the silex unit prior to replacement of (2) DI Sacks -Disinfect the silex housings before installing the new sacks -Replace DI Packs (send out exhausted sacks to be regenerated for the next service. Includes replacement certificates) *To be completed alongside a quarterly service*

ANNUAL SERVICE TO INCLUDE:

-Disinfection of Storage Tank -Disinfection of 55 gallon storage tank *To be completed alongside a quarterly service*

PARTS INCLUDED:

-AMERIWATER CHLOR PLUS CARBON

CARTRIDGES- CASE OF 6 (PN: 124009)

- AMERIWATER, PT-401, ANTI-SCALANT, 4

X 1 GALLON (PN: 153796)

- (TWO) AMERIWATER DI-2101S, STARTUP

STANDARD RECIRC. RESIN PACK, .5

CU.FT.

- (TWO) AMERIWATER DI-2101C,

REGENERATION CERTIFICATE,

STANDARD DI, .5 CU.FT.