S30 Chiller plant valve drawings.pdf
PDF 2 MB Posted
- Attached to
- Z2NB--542-26-105 | Correct FCA Deficiencies Chiller Plant | NCO 4 Construction East (VA-26-00010360)
- Solicitation number
- 36C24426B0001
About this file
Chiller Replacement HVAC Project Documentation
This document set contains engineering drawings and technical specifications for a chiller replacement project at the VAMC (Veterans Affairs Medical Center) Coalesville facility located at 1400 Blackhorse Hill Road, Coalesville, PA 19320-2096. The project, identified as H–300 and H–400, involves the replacement of existing chilled water systems with new equipment and associated HVAC modifications. The drawings include a comprehensive HVAC new work plan showing the integration of three new water softeners, updated chilled water piping configurations, and modifications to existing mechanical systems. The project documentation incorporates detailed technical specifications for multiple components including water chillers (identified in specification tables with capacities ranging across multiple units), centrifugal pumps for chilled water circulation, hydronic flow measurement stations, and air separator units designed to remove air from the water system.
The technical drawings provide detailed schematics for critical system components including a horizontal split-case pump detail, electric chiller piping diagram, air separator detail, and chiller end detail configurations. Supporting documentation includes equipment schedules for water chillers, pumps, hydronic flow measurement stations, and air separators, along with electrical abbreviations and control notes. Electrical notes specify that all starting, bypass/soft, and control devices must be charged with an appropriate control type as indicated in the schedules, with all control wiring provided by the electrical contractor. The project scope encompasses complete mechanical system modifications necessary to support the new chilled water equipment, with coordination required between mechanical and electrical trades for proper system commissioning and operation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24426B0001 0003.docx | DOCX document | |
| S05 Correct FCA Chiller Plant Deficiencies RFI 542-26-105.docx | DOCX document | |
| S30 Building 17 Elevations Loovers.pdf | ||
| 36C24426B0001 0002.docx | DOCX document | |
| 36C24426B0001 0001.docx | DOCX document | |
| S04 542-26-105 Pre-Bid Sign-in Sheet.pdf | ||
| P11 B17 Roof Drawing.pdf | ||
| P11 Tower Valves.pdf | ||
| P11 Attachment 5 Construction Safety Standards.pdf | ||
| P11 Combined Specifications Updated.pdf | ||
| P11 VHA Dir 7715 Safety and Health During Construction.pdf | ||
| P11 Chiller Plant Valve Drawings.pdf | ||
| 36C24426B0001_1.docx | DOCX document |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Highlight
New water softeners
File details come from the government source that posted it. Updated .