Attachment A.pdf
PDF 38 KB Posted
- Solicitation number
- 36C24425Q0804
About this file
The document is a Boiler Tune Up Field Data form designed to record comprehensive technical measurements and observations during a boiler maintenance and combustion efficiency assessment. The form includes 13 data collection columns to capture critical parameters such as ambient temperature, VFD settings, windbox pressure, draft conditions, flue gas temperatures, oxygen and carbon monoxide levels, fuel pressures and temperatures, steam pressure, and burner combustion efficiency. The template provides space for technician details, boiler designation, fuel source, location, date, burner profile, and general observations, allowing for systematic documentation of boiler performance diagnostics across multiple firing positions.
The form is associated with a Department of Veterans Affairs solicitation (RFQ 36C24425Q0804) for boiler combustion tuning services, specifically targeting Service-Disabled Veteran Owned Small Businesses (SDVOSB) under NAICS code 811310. The solicitation seeks boiler tuning services with a business size standard of $13 million, with questions accepted until June 18th, 2025 at 3:00 PM Eastern Time. Potential contractors must be registered in the System for Award Management (SAM) database and comply with Service Contract Act Wage Determinations. The contract will be issued on a Standard Form 1449, with the period of performance estimated in the attached schedule.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24425Q0804.pdf | ||
| 36C24425Q0804.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Data Units 1 2 3 4 5 6 7 8 9 10 11 12 13
Ambient Temperature ( ˚F )
VFD Setting ( % )
Windbox Pressure (in H2O )
Draft (in H2O )
Final Flue Temperature ( ˚F )
Flue Gas Oxygen ( O2 ) ( % Dry )
Carbon Monoxide ( CO ) ( ppm )
Carbon Dioxide ( CO2 ) ( % )
Excess Air ( % )
Fuel Pressure to Control Valve ( psig )
Fuel Pressure at Burner ( Gas ) (in H2O )
Fuel Pressure at Burner (Oil ) ( psig )
Fuel Temperature ( ˚F )
Atomizing Pressure ( psig )
Steam Pressure ( psig )
Flame Notes
Flue Gas Nox ( PPM )
Burner Combustion Efficiency ( % )
Boiler Tune Up Field Data
Firing Position
Technician Signature:Technician:
Company:
Location:
Date:
Boiler Designation:
Fuel Source:
Burner Profile:
General Description and Observations