36C24424Q0946 0002.docx
DOCX document 16 KB Posted
- Attached to
- F103--Water System Testing and Maintenance | Dental Clinic Water Testing | Pittsburgh (VA-25-00003650)
- Solicitation number
- 36C24424Q0946
About this file
This document is an amendment to a previous combined solicitation for water system testing and maintenance services for the Pittsburgh VA Medical Center. The solicitation, numbered 36C24424Q0946, is a Request for Quote (RFQ) for a five-year, firm-fixed-price Indefinite Delivery - Indefinite Quantity (IDIQ) contract. The required services include quarterly testing of dental clinic water lines, with specific protocols for sample collection and analysis. The solicitation is a Service-Disabled Veteran Owned Small Business (SDVOSB) set-aside, with a response due date of September 4, 2024, at 10:00 AM Eastern Time. The North American Industrial Classification System (NAICS) code is 541380, and the Product/Service Code is F103. The contracting office is the Department of Veterans Affairs Network Contracting Office 4 in Wilkes-Barre, PA.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Question and Answer - 36C24424Q0946 - Version 2.docx | DOCX document | |
| Attachment B - Past Performance Questionnaire - Version 2.docx | DOCX document | |
| 36C24424Q0946 0001.docx | DOCX document | |
| Attachment A - Statement of Work - Version 2.pdf | ||
| Question and Answer - 36C24424Q0946.docx | DOCX document | |
| Attachment B - Past Performance Questionnaire.docx | DOCX document | |
| 36C24424Q0946.docx | DOCX document | |
| Attachment D - Wage Determination.pdf | ||
| Attachment A - Statement of Work.pdf | ||
| Attachment C - Price Schedule.docx | DOCX document | |
| Combined Synopsis - 36C24424Q0946 - Dental Water Testing - 646.docx | DOCX document |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Amendment to a Previous Combined Solicitation
Amendment to a Previous Combined Solicitation
| SUBJECT* |
| Water System Testing and Maintenance | Dental Clinic Water Testing | Pittsburgh (VA-25-00003650) |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 18711 |
| SOLICITATION NUMBER* |
| 36C24424Q0946 |
| RESPONSE DATE/TIME/ZONE |
| 09-04-2024 10:00 AM EASTERN TIME, NEW YORK, USA |
| ARCHIVE |
| 30 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| F103 |
| NAICS CODE* |
| 541380 |
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
Network Contracting Office 4 Wilkes-Barre VA Medical Center 1111 East End BLVD Wilkes-Barre PA 18711
POINT OF CONTACT*
Contracting Officer Edward Ferkel edward.ferkel@va.gov
PLACE OF PERFORMANCE
| ADDRESS |
| Pittsburgh VA Medical Center |
University Drive C
Pittsburgh PA
| POSTAL CODE |
| 15240 |
| COUNTRY |
| USA |
ADDITIONAL INFORMATION
AGENCY’S URL
URL DESCRIPTION
AGENCY CONTACT’S EMAIL ADDRESS
EMAIL DESCRIPTION
DESCRIPTION
See attached document: Question and Answer - 36C24424Q0946 - Version 2.
Question and Answer
1. In the Statement of Work, General Requirements, C states sample to be collected at first “draw” to catch the water that comes out immediately from the outlet, without the use of “flush”. Bacterial sample procedure includes flushing.
Answer: Testing protocol a. Test each line separately. b. Remove all handpieces and any other equipment reprocessed by SPS before drawing samples from the lines. Air-water syringe tips should be removed. The air-water syringe itself, if not changed between patients (e.g., if barrier + disinfection is accomplished by dental personnel), should remain on the line while drawing the sample. c. Quarterly d. Use of a water testing lab certified in environmental specimens is preferred. e. Report results to the Infection Control Committee or the Safety Committee as appropriate for the facility.
Action Levels f. If >200 cfu but 500 cfu line before returning it to service. h. If shocking and retesting again yields >500 cfu i. Line remains out of service. ii. Contact dental equipment manufacturer and waterline treatment manufacturer for recommendations on options, such as repeat shocking or line replacement.
SOW has been updated
2.
Does the HPC analysis need PA state cert? Can we send the quote and certification directly to your email once prepared? Can we have a separate line for sampling fees or should the sampling price be incorporated in the cost of analysis?
Laboratory used for analysis must be EPA or state certified to conduct HPC analysis. Contractor must provide a copy of EPA or state certificate for the laboratory.
I believe the answer is NO either EPA certified or state EPA certified.
All submissions are completed via email at Edward.ferkel@va.gov. They also must be complete according to the instructions listed in the combined synopsis.
Please only include pricing listed in the price schedule. Any other fees are assumed by the vendor.
End of Document
| *= Required Field |
| Amendment to a Previous Combined Solicitation |
Page 1 of
Amendment to a Previous Combined Solicitation
File details come from the government source that posted it. Updated .