597-17-101 FULL SET 100PCT_Part2.pdf
PDF 12 MB Posted
- Solicitation number
- 36C24422R0030
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
100C6
100C11
MORGUE COOLER SLAB
126A
100C3
104E
ELEC.
ROOM
TE
L.
RO
OM
WORK / COPIER
ROOM
STORAGE
JANITORS
CLOSET
OPEN
OFFICE
OPEN
OFFICE
#2
#2
#2
#2
UP
1A22
1A21
VEG 4.14
595-17-101
1700 S. LINCOLN AVE; LEBANON, PA 17042
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
CONSULTANTS: ARCHITECT/ENGINEERS: STAMP: 100% CONSTRUCTION
DOCUMENTS
PHYSICAL SECURITY
IMPROVEMENTS
of 50
GENERAL NOTES:
12/04/2020 GDD MLH
A-108
37, 99, 101, 102
BUILDINGS 37, 99, 101, 102 -
REPLACE DOORS AND LOCKS
8' 16' 32' 64' 128'0
BUILDING 101 - FIRST FLOOR KEYPLAN
SCALE: 1/32" = 1'-0"
DATA/
PHONE
8' 16' 32' 64' 128'0
BUILDING 102 - FIRST FLOOR KEYPLAN
SCALE: 1/32" = 1'-0"
8' 16' 32' 64' 128'0
BUILDING 99 - FIRST FLOOR KEYPLAN
SCALE: 1/32" = 1'-0"
VOICE/ DATA
CLOSET
DATA/
PHONE
8' 16' 32' 64' 128'0
BUILDING 37 - BASEMENT KEYPLAN
SCALE: 1/16" = 1'-0"
IT CLOSET
BA03
BA03
SCALE:
2' 4' 8' 16' 32'
1/8" = 1'-0"
IT CLOSET, ROOM #039
P l a n
N o r t h
T r u e
N o r t h
SCALE:
2' 4' 8' 16' 32'
1/8" = 1'-0"
IT TELECOMM/DATA CLOSET, ROOM #BA03
P l a n r t h
T r r t h
SCALE:
2' 4' 8' 16' 32'
1/8" = 1'-0"
IT CLOSET, ROOM #141
P l a n
N o r t h
T r r t h
A. REFER TO A-500 FOR DOOR SCHEDULE.
SCALE:
2' 4' 8' 16' 32'
1/8" = 1'-0"
IT CLOSET, ROOM #121
P l a n
N o r t h
T r r t h
A-108
A-108
A-108 3A-108
EI106
EI106
EI106
EI106
FD
12031203
12021202
12011201
1303 1302
CORRIDOR
13C1
14C4
14C2
1A
2C
2A
2B
4A
4B
5A
6A
7A
2D
4C
1062C
2A
2B
4A
4B
5A
6A
7A
2D
4C
VEG 4.14
595-17-101
1700 S. LINCOLN AVE; LEBANON, PA 17042
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
CONSULTANTS: ARCHITECT/ENGINEERS: STAMP: 100% CONSTRUCTION
DOCUMENTS
PHYSICAL SECURITY
IMPROVEMENTS
of 50
GENERAL NOTES:
KEYNOTES:
12/04/2020 GDD MLH
A-109
104, 106, 136
BUILDINGS 104, 106, 136 -
REPLACE DOORS AND LOCKS
8' 16' 32' 64' 128'0
BUILDING 104 - GROUND FLOOR KEYPLAN
SCALE: 1/32" = 1'-0"
GAS
CYLINDER
SP504
IT CLOSET
1404 MEDS
BUILDING 106 - KEYPLAN
4' 8' 16' 32' 64'0
SCALE: 1/16" = 1'-0" SCALE:
2' 4' 8' 16' 32'
1/8" = 1'-0"
BUILDING 136 - FIRST FLOOR
COMMERCIAL
TELECOMM AND DATA
CONNECTION/SERVER
ROOM
TELEPHONE
EQUIPMENT ROOM
PROVIDE AND INSTALL ANCHOR FOR (E) DRUG CABINET
(TO FLOOR) PER MANUFACTURER'S RECOMMENDATION
PROVIDE AND INSTALL LOCKABLE SECURITY WINDOW
SCREEN @ INTERIOR; RE: 6/A-501
SP0504
02A
107A
107B
A. REFER TO A-500 FOR DOOR SCHEDULE.
SCALE:
2' 4' 8' 16' 32'
1/8" = 1'-0"
IT TELECOMM/DATA CLOSET #1404
SCALE:
2' 4' 8' 16' 32'
1/8" = 1'-0"
BUILDING 104 - LOWER LEVEL
COMPRESSED MEDICAL GAS STORAGE, ROOM #SP504
SCALE:
2' 4' 8' 16' 32'
1/8" = 1'-0"
PACU MEDICATION ROOM #1213
SCALE:
2' 4' 8' 16' 32'
1/8" = 1'-0"
IT TELECOMM/DATA CLOSET ROOM #002
P l a n
N o r t h
T r r t h
P l a n
N o r t h
T r r t h
P l a n
N o r t h
T r r t h
A-109
A-109
A-109
EI106
EI106
EI106
EI106
P l r t h
T r r t h
A. REFER TO A-001 FOR KEY PLANS.
B. REFER TO FLOOR PLANS FOR HORIZONTAL DIMENSIONS;
REFER TO ELEVATIONS FOR TYPICAL VERTICAL DIMENSIONS;
VERIFY ALL DIMENSIONS IN FIELD.
PROVIDE AND INSTALL 8MIL BLAST RESISTANT FILM AT
INTERIOR AND SEAL GLAZING TO FRAME AT INTERIOR, TYP;
RE: 5/A-501
ALL AFFECTED PANES SHOWN THUS:
AFFECTED SYSTEMS IDENTIFIED IN PLAN AS:
VEG 4.14
595-17-101
1700 S. LINCOLN AVE; LEBANON, PA 17042
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
CONSULTANTS: ARCHITECT/ENGINEERS: STAMP: 100% CONSTRUCTION
DOCUMENTS
PHYSICAL SECURITY
IMPROVEMENTS
of 50
GENERAL NOTES:
KEYNOTES:
12/04/2020 GDD MLH
A-301
BUILDING 17 -
SECURITY FILM ELEVATION
SCALE:
2' 4' 8' 16' 32'
1/8" = 1'-0"
FIRST FLOOR PLAN - SECURITY FILM LOCATIONS
Plan
North
SCALE:
2' 4' 8' 16' 32'
1/8" = 1'-0"
MAIN ENTRY
1 1 1
A-301
A-301
A-301
A-301
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16'0
CENTER ENTRY WITH CLERESTORY
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16'0
SIDE ENTRY WITH CLERESTORY (TYP OF TWO)
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16'0
STOREFRONT GLAZING, TYP
4'- 8 3
/4" 4'-
5 1 /2"
3'- 8 1
/4" 4'-
9 1 /2"
3'-4 3/8" 3'-5 5/8" 3'-4 3/8"
2'- 8 1
/8" 1'-
6" 3'-
8 1 /4"
4'- 9 1
/2"
3'-3 1/4" 3'-4 1/2" 3'-3 1/4"
2'- 8 1
/8"
2'-3" 2'-3"2'-7" 2'-7"
7'- 0 1
/2" 2'-
1" 3'-
4"
2'-0" 4'-4 1/4" 4'-6 3/4"
Stair-2
Regist.
SIM
LKJH
11091109
11011101
11101110111111111112111211131113111411141115111511161116
11291129
12031203
15C515C5
11251125
11021102
11031103
11041104
11051105
11071107
11081108
11231123
11271127
12021202
12011201
12041204
12101210
Meds
11311131
12C112C1
11261126
11C511C5
11C7
11C6
1303 1302
15211521
11C811C8
11C111C1
11C211C2
11241124
11C411C4
10011001
10021002
10031003
10071007
10041004
10051005
10081008
10001000
11061106
1307 1305
14C3
14C2 14C1
1306 1304
Scrub
CORRIDOR
13C1
11C3
FD
56789
K J
A. REFER TO A-001 FOR KEY PLANS.
B. REFER TO FLOOR PLANS FOR HORIZONTAL DIMENSIONS;
REFER TO ELEVATIONS FOR TYPICAL VERTICAL DIMENSIONS;
VERIFY ALL DIMENSIONS IN FIELD.
PROVIDE AND INSTALL 8MIL BLAST RESISTANT FILM AT
INTERIOR AND SEAL GLAZING TO FRAME AT INTERIOR, TYP;
RE: 5/A-501
ALL AFFECTED PANES SHOWN THUS:
AFFECTED SYSTEMS IDENTIFIED IN PLAN AS:
VEG 4.14
595-17-101
1700 S. LINCOLN AVE; LEBANON, PA 17042
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
CONSULTANTS: ARCHITECT/ENGINEERS: STAMP: 100% CONSTRUCTION
DOCUMENTS
PHYSICAL SECURITY
IMPROVEMENTS
of 50
GENERAL NOTES:
KEYNOTES:
12/04/2020 GDD MLH
A-302
BUILDING 104 -
SECURITY FILM ELEVATIONS
1 1
P l a n
N o r t h
T r r t h
SCALE:
2' 4' 8' 16' 32'
1/8" = 1'-0"
FIRST FLOOR PLAN - SECURITY FILM LOCATIONS
SCALE:
2' 4' 8' 16' 32'
1/8" = 1'-0"
EMERGENCY DEPARTMENT ENTRY
SCALE:
2' 4' 8' 16' 32'
1/8" = 1'-0"
SURGERY ENTRY
SCALE:
2' 4' 8' 16' 32'
1/8" = 1'-0"
SURGERY - NORTH ELEVATION
A-302
A-302
A-302
11 1 1
'-7
1/ 2"
128'-5 1/2"
9'-5" 10 '-5
1/ 2"
8'-11 1/2"
'-5
'-1
0" 4'-1"
1'- 0"
1'- 4"
2'-
2'-
2'-
1'- 1"
5'-
2'-
9"
4'-9" 4'-10" 4'-10" 4'-8"4'-10" 1'-11"4'-10"4'-10"1'-1" 4'-10"4'-10"4'-10"4'-10"4'-10" 1'-10"
2'-6"2'-6"3'-10" 2'-1" 4'-0" 2'-1" 3'-10" 3'-10" 3'-10" 3'-10" 3'-10" 3'-10" 3'-10" 4'-0" (x2)
3'- 1"
3'- 1"
EN
TR
Y
PA
RT
IA
LL
Y
OB
ST
RU
CT
ED
IN
T
HI
S
VI
EW
2'-
7'- 0"
1'- 2"
4'-10"4'-10"4'-10"4'-10"4'-10" 4'-10"3'-8"4'-10"4'-10"4'-10"2'-0" 4'-10" 4'-10" 4'-10" 4'-10" 4'-10" 4'-10" 4'-10"4'-10" 4'-10" 4'-10" 4'-10" 4'-10" 4'-10" 4'-0"4'-10" 3'-4"
2'- 9"
5'-
1'-
1" 1'-
4"
2'- 9"
1'- 9"
6'- 4"
3'-4"
12/04/2020 GDD MLH
A-500
NA
DOOR SCHEDULE
(ALL BUILDINGS)
VEG 4.14
595-17-101
1700 S. LINCOLN AVE; LEBANON, PA 17042
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
CONSULTANTS: ARCHITECT/ENGINEERS: STAMP: 100% CONSTRUCTION
DOCUMENTS
PHYSICAL SECURITY
IMPROVEMENTS
of 5029
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16'0
CANTEEN RETAIL STORE - ENLARGED PLAN
2A
A-500
2B
A-500
SCALE: 1/2" = 1'-0"
6" 1' 2' 4' 8'0
STOREFRONT ELEVATIONS
10'-5 1/4" V.I.F.
EQ EQRE: DOOR
SCHEDULE
RE
: D
OO
R
SC
HE
D
8'- 6"
V.
I.F
2'- 5 5
/8" V.
I.F
2"
DOOR ABBREVIATION LEGEND
EX = EXISTING HM = HOLLOW METAL WD = WOOD
AL
IG
N
ALIGN
ELEVATION A ELEVATION B
3D
A-500
3B
A-500
3D
A-500
3A
A-500
3A
A-500
3A
A-500
4K
A-500
4E
A-500
4K
A-500
4E
A-500
4G
A-500
4H
A-500
4H
A-500
4J
A-500
3C
A-500
SCALE: 3" = 1'-0"
1" 2" 4" 8" 1'-4"0 1'-0"
STOREFRONT DETAILS
DETAIL B - BOTTOM RAIL
DETAIL C - DOOR HEAD
DETAIL D - TRANSOM HEAD
4F
A-500
4F
A-500
ALUM THRESHOLD SET IN SEALANT
ANCHOR THRESHOLD PER MANUF
RECOMMENDATION
BOTTOM DOOR RAIL
DOOR SWEEP
TOP DOOR RAIL
1/4" TEMPERED GLAZING (CLEAR), TYP
STOREFRONT HEAD
DOOR HEAD/MULLION
8'- 6"
V.
I.F
FR
AM
E
HE
IG
HT
1 3 /4"
4"
TR
AN
SO
M
HE
IG
HT
1 7 /8"
DO
OR
H
EI
GH
T
RE
: S
CH
ED
3 7 /8"
2 1 /4"
1/4" TEMPERED GLAZING (CLEAR), TYP
DETAIL E - JAMB DETAIL F - DOOR JAMB DETAIL G - STILES DETAIL H - DOOR JAMB
(@ TRANSOM)
DETAIL J - MULLION DETAIL K - OUTSIDE CORNER
SCALE: 3" = 1'-0"
1" 2" 4" 8" 1'-4"0 1'-0"
STOREFRONT DETAILS
DETAIL A - SILL
4"
1'- 6"
3/8
3/8
1 7
/8" STOREFRONT SILL
1/4" TEMPERED GLAZING (CLEAR), TYP
DOOR JAMB WITH SIDE LITE1/4" TEMPERED GLAZING
(CLEAR), TYP LOCK/PIVOT STILE, TYP
2 1/8"3/8" 1 3/4" 2 1/8"
ALUM STILES WITH
ADJUSTABLE ASTRAGAL
2 3/16"
1/4" TEMPERED GLAZING
(CLEAR), TYP
1 3/4" 1/2"
SIDE LITE
SIDE
DOOR
SIDE
1 3/4" 4"
4"
1 3/4"
MULLION HEAD/JAMB CORNER POST
4J
A-500
4J
A-500
4J
A-500
FRAME WIDTH
V.I.F.
FRAME WIDTH
V.I.F.
SCALE: NO SCALE
DOOR TYPES
A
SCALE: NO SCALE
FRAME TYPES
B C
FLUSH PANEL
(MATCH EXIST)
FULL HT GLASS
(TEMPERED)
KD FRAME KD FRAME
(W/O RETAINER CLIPS;
NAILING FLANGE ONLY)
STOREFRONT
(RE: 2/AS-500)
A B C
PER
SCHED
PE
R
SC
HE
D
PER
SCHED
PE
R
SC
HE
D
PER
SCHED
PE
R
SC
HE
D
PER
SCHED
2"
PE
R
SC
HE
D 2"
PER
SCHED
PE
R
SC
HE
D
WOOD TRIM TO
MATCH EXISTING
2" PER
SCHED
PE
R
SC
HE
D
A
HEAD
C
SILL
E
JAMB - RIGHT
D
JAMB - LEFT
B
BRACE
EXPANDED
RETAIL
12/04/2020 GDD MLH
A-501
NA
SECURITY DETAILS
VEG 4.14
595-17-101
1700 S. LINCOLN AVE; LEBANON, PA 17042
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
CONSULTANTS: ARCHITECT/ENGINEERS: STAMP: 100% CONSTRUCTION
DOCUMENTS
PHYSICAL SECURITY
IMPROVEMENTS
of 5030
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16'0
CANTEEN RETAIL STORE - ENLARGED PLAN
OPENING WIDTH
V.I.F.
SUB-FRAME WIDTH
V.I.F.
2 1/2"
MIN
2 1/2"
MIN
OP
EN
IN
G
HE
IG
HT
V.
I.F
BR
AC
E
CE
NT
ER
LIN
E
2 1 /2"
MI
N
2 1 /2"
MI
N
SU
B-
FR
AM
E
HE
IG
HT
V.
I.F
6A
A-500
6B
A-500
6C
A-500
6D
A-500
6E
A-500
SCALE: 3/4" = 1'-0"
3" 6" 1' 3' 5'0 2'
SECURITY SCREEN ELEVATION
SCALE: 3/4" = 1'-0"
3" 6" 1' 3' 5'0 2'
SECURITY SCREEN DETAILS
1-1/2"
MIN
OPENING WIDTH
V.I.F.
SUB-FRAME WIDTH
V.I.F.
2-1/2" 2-1/2"
INSTALLATION FASTENER, TYP;
SEE MANUFACTURER REQUIREMENTS
OP
EN
IN
G
HE
IG
HT
V.
I.F
SU
B-
FR
AM
E
HE
IG
HT
V.
I.F
2- 1/2
2-
1/2
BR
AC
E
CE
NT
ER
LIN
E
3A
A-501
A-501
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16'0
CANTEEN RETAIL STORE - ENLARGED PLAN
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16'0
STOREFRONT ELEVATION
3B
A-501
A-501
8'- 6"
V.
I.F
4'-8 1/2" V.I.F.
4'-8 1/2" V.I.F.
8 MIL SAFETY AND SECURITY WINDOW FILM, TYP;
SHOWN THUS:
BASIS OF DESIGN: 3M ULTRA S800
IMPACT PROTECTION ATTACHMENT SEALANT
AROUND FULL PERIMETER OF GLAZING BY SAME
MANUFACTURER AS SECURITY FILM, TYP
ELEVATION A ELEVATION B
SPANDREL GLAZING IN FRAME ABOVE CEILING
7'- 1 1
/4" V.
I.F
2'- 0 3
/4" V.
I.F
2'- 0 3
/4" V.
I.F .3'-9 1/4"
V.I.F.
3'-9 1/2"
V.I.F.
3'-9 1/4"
V.I.F.
A-501
SCALE: 3" = 1'-0"
1" 2" 4" 8" 1'-4"0 1'-0"
BREAK AND ENTRY FILM DETAIL
EXISTING ALUM WINDOW FRAME TO REMAIN, TYP
INTERIOR
EXTERIOR
8 MIL SAFETY AND SECURITY WINDOW FILM, TYP;
BASIS OF DESIGN: 3M SCOTCHSHIELD SAFETY &
SECURITY WINDOW FILM ULTRA S800
3/8
3/8"
IMPACT PROTECTION PROFILE ATTACHMENT
SYSTEM SHALL ATTACH TO FILM AND FRAME 3/8"
MINIMUM, TYP
SCALE: 3" = 1'-0"
1" 2" 4" 8" 1'-4"0 1'-0"
BLAST RESISTANT FILM DETAIL
EXISTING ALUM WINDOW FRAME TO REMAIN, TYP
INTERIOR
EXTERIOR
8 MIL SAFETY AND SECURITY WINDOW FILM, TYP;
BASIS OF DESIGN: 3M SCOTCHSHIELD SAFETY &
SECURITY WINDOW FILM ULTRA 800
IMPACT PROTECTION PROFILE ATTACHMENT
SYSTEM SHALL ATTACH TO FILM AND FRAME 1/2"
MINIMUM (EXCLUDING GASKET), TYP;
BASIS OF DESIGN: DOW CORNING 995 SILICONE
STRUCTURAL SEALANT
1/2
1/2"
GLAZING STOP NOT REQUIRED TO BE TRIMMED, TYP
TRIM GLAZING STOP FLUSH WITH FRAME, TYP
12/04/2019 TL BW
E-001
N/A
ELECTRICAL ABBREVIATIONS AND
GENERAL NOTES
VEG 4.14
595-17-101
1700 S. LINCOLN AVE; LEBANON, PA 17042
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
CONSULTANTS: ARCHITECT/ENGINEERS: STAMP: 100% CONSTRUCTION
DOCUMENTS
PHYSICAL SECURITY
IMPROVEMENTS
of 50
COMMUNICATION GENERAL NOTES
ELECTRICAL GENERAL NOTES - DEMOLITION
SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR PHASES OF DEMOLITION AND
CONSTRUCTION. COORDINATE WITH GENERAL CONSTRUCTION.
DISCONNECT AND REMOVE ALL ELECTRICAL DEVICES AND LIGHTING FIXTURES IN DEMOLITION AREAS UNLESS NOTED OTHERWISE. DISCONNECT AND REMOVE ASSOCIATED CONDUIT AND WIRE BACK TO OVERCURRENT PROTECTIVE DEVICE. COMPLETELY CUT/CAP CONDUITS IN CONCRETE SLAB AND IN THE AREA OF WORK PERIMETER. DISCONNECT AND REMOVE ALL ABANDONED CIRCUITS AND CONDUITS.
PROVIDE CONDUIT AND WIRE AS REQUIRED FOR CONTINUITY OF CIRCUITS TO ANY EXISTING DEVICES TO
REMAIN. COORDINATE AND VERIFY REQUIREMENTS WITHIN NEW AREA OF WORK.
ELECTRICAL GENERAL NOTES
SPECIFICATIONS TAKE PRECEDENT OVER DRAWINGS.
MULTI-GANG BACKBOXES FOR DIFFERENT VOLTAGES AND TYPES OF EMERGENCY AND NORMAL BRANCH
WIRING DEVICES SHALL HAVE DIVIDERS BETWEEN DEVICES.
CORE DRILL AND SAW CUT, AS REQUIRED, FOR FLOOR AND WALL PENETRATIONS. SEAL REMAINING
ANNULUS WITH FIRE CAULK.
FURNISH ACCESS DOORS OR PANELS FOR INSTALLATION BY GENERAL CONTRACTOR IN WALLS AND
CEILINGS WHERE ACCESS IS REQUIRED TO CONCEALED ELECTRICAL BOXES AND DEVICES.
ARMORED CABLE (AC) MAY BE USED FOR LAY-IN FIXTURE PIGTAILS. ARMORED CABLE (AC) SHALL NOT BE USED FOR BRANCH CIRCUIT HOMERUNS. ARMORED CABLE (AC) SHALL NOT BE USED WHERE MORE THAN THREE CONDUCTORS (PHASE/NEUTRAL/GROUND) ARE REQUIRED, WHERE EXPOSED; OR IN LENGTHS
EXCEEDING 20 FEET EXCEPT FOR TEMPORARY WIRING.
PROVIDE ALL ELECTRICAL WORK IN ACCORDANCE WITH THE CURRENT NATIONAL ELECTRICAL CODE AND
THE REQUIREMENTS OF THE VHA.
COORDINATE ALL OUTAGES WITH VHA COR PER SPECS PRIOR TO WORK BEING DONE.
KEYNOTES
KEYNOTE00
NEW - EXISTING AND DEMO LINE TYPES
NEW LINE TYPE
EXISTING LINE TYPE
DEMO LINE TYPE
DEMO HATCH
LIGHTING GENERAL NOTES
A.
B.
C.
D.
E.
F.
ALL RECESSED LIGHTING FIXTURE IN LAY-IN CEILINGS SHALL BE INSTALLED WITH 6' LONG FLEXIBLE METAL
CONDUIT.
ALL MOUNTING HEIGHTS FOR LIGHTING FIXTURES ARE TO THE BOTTOM OF THE FIXTURES UNLESS
INDICATED OTHERWISE.
SEE ARCHITECTURAL EXTERIOR ELEVATIONS FOR MOUNTING HEIGHTS OF EXTERIOR LIGHTING FIXTURES.
CIRCUIT WIRING IS NOT SHOWN. SWITCH AND CIRCUITING INTENT SHALL BE AS DESIGNATED AT
EACH LIGHT FIXTURE.
PROVIDE PROPER NUMBER OF CONDUCTORS TO ACHIEVE CIRCUITING AND SWITCHING SHOWN.
CIRCUIT NUMBERS AT DEVICES CORRESPOND TO PANELBOARD BREAKERS (SEE PANELBOARD
SCHEDULE). BRANCH CIRCUITS SHALL BE SIZED ACCORDING TO THE CIRCUIT BREAKER RATING, UNLESS
INDICATED OTHERWISE ON THE ELECTRICAL EQUIPMENT SCHEDULE.
ELECTRICAL GENERAL NOTES
SPECIFICATIONS TAKE PRECEDENT OVER DRAWINGS.
MULTI-GANG BACKBOXES FOR DIFFERENT VOLTAGES AND TYPES OF EMERGENCY AND NORMAL BRANCH
WIRING DEVICES SHALL HAVE DIVIDERS BETWEEN DEVICES.
CORE DRILL AND SAW CUT, AS REQUIRED, FOR FLOOR AND WALL PENETRATIONS. SEAL REMAINING
ANNULUS WITH FIRE CAULK. REFER TO SPECIFICATION "FIRE STOPPING" 07-84-00.
FURNISH ACCESS DOORS OR PANELS FOR INSTALLATION BY GENERAL CONTRACTOR IN WALLS AND
CEILINGS WHERE ACCESS IS REQUIRED TO CONCEALED ELECTRICAL BOXES AND DEVICES.
ARMORED CABLE (AC) MAY BE USED FOR LAY-IN FIXTURE PIGTAILS. ARMORED CABLE (AC) SHALL NOT BE USED FOR BRANCH CIRCUIT HOMERUNS. ARMORED CABLE (AC) SHALL NOT BE USED WHERE MORE THAN THREE CONDUCTORS (PHASE/NEUTRAL/GROUND) ARE REQUIRED, WHERE EXPOSED; OR IN LENGTHS
EXCEEDING 20 FEET EXCEPT FOR TEMPORARY WIRING.
PROVIDE ALL ELECTRICAL WORK IN ACCORDANCE WITH THE CURRENT NATIONAL ELECTRICAL CODE AND
THE REQUIREMENTS OF THE VHA.
COORDINATE ALL OUTAGES WITH VHA COR PER SPECS PRIOR TO WORK BEING DONE.
LIGHTING GENERAL NOTES
ALL RECESSED LIGHTING FIXTURE IN LAY-IN CEILINGS SHALL BE INSTALLED WITH 6' LONG FLEXIBLE METAL
CONDUIT.
ALL MOUNTING HEIGHTS FOR LIGHTING FIXTURES ARE TO THE BOTTOM OF THE FIXTURES UNLESS
INDICATED OTHERWISE.
SEE ARCHITECTURAL EXTERIOR ELEVATIONS FOR MOUNTING HEIGHTS OF EXTERIOR LIGHTING FIXTURES.
CIRCUIT WIRING IS NOT SHOWN. SWITCH AND CIRCUITING INTENT SHALL BE AS DESIGNATED AT
EACH LIGHT FIXTURE.
PROVIDE PROPER NUMBER OF CONDUCTORS TO ACHIEVE CIRCUITING AND SWITCHING SHOWN.
CIRCUIT NUMBERS AT DEVICES CORRESPOND TO PANELBOARD BREAKERS (SEE PANELBOARD
SCHEDULE). BRANCH CIRCUITS SHALL BE SIZED ACCORDING TO THE CIRCUIT BREAKER RATING, UNLESS
INDICATED OTHERWISE ON THE ELECTRICAL EQUIPMENT SCHEDULE.
COMMUNICATION GENERAL NOTES
SECURITY CONTRACTOR (SC) TO PROVIDE SHOP DRAWINGS AND SUBMIT TO VHA FOR APPROVAL BEFORE
PROJECT START.
EXISTING SYSTEMS AND SERVICES ALREADY IN USE MAY DETERMINE A BROADER REQUIREMENT FOR A
COMPLETE WORKING AND UNIFIED SYSTEM.
FIBER OPTIC CABLING WILL BE REQUIRED BASED ON ANY DISTANCE OVER 90 METERS.
ELECTRICAL GENERAL NOTES - DEMOLITION
SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR PHASES OF DEMOLITION AND
CONSTRUCTION. COORDINATE WITH GENERAL CONSTRUCTION.
DISCONNECT AND REMOVE ALL ELECTRICAL DEVICES AND LIGHTING FIXTURES IN DEMOLITION AREAS UNLESS NOTED OTHERWISE. DISCONNECT AND REMOVE ASSOCIATED CONDUIT AND WIRE BACK TO OVERCURRENT PROTECTIVE DEVICE. COMPLETELY CUT/CAP CONDUITS IN CONCRETE SLAB AND IN THE AREA OF WORK PERIMETER. DISCONNECT AND REMOVE ALL ABANDONED CIRCUITS AND CONDUITS.
PROVIDE CONDUIT AND WIRE AS REQUIRED FOR CONTINUITY OF CIRCUITS TO ANY EXISTING DEVICES TO
REMAIN. COORDINATE AND VERIFY REQUIREMENTS WITHIN NEW AREA OF WORK.
KEYNOTES
KEYNOTE00
NEW - EXISTING AND DEMO LINE TYPES
NEW LINE TYPE
EXISTING LINE TYPE
DEMO LINE TYPE
DEMO HATCH
MIN MINIMUM
MLO MAIN LUGS ONLY
MOCP MAXIMUM OVERCURRENT PROTECTION
MT MOUNT
MTD MOUNTED
MTG MOUNTING
MTS MANUAL TRANSFER SWITCH
MV MEDIUM VOLTAGE
MVA MEGAVOLT-AMPERE
MW MEGAWATT
N
NA NOT APPLICABLE
NC NORMALLY CLOSED
NEC NATIONAL ELECTRIC CODE
NEMA NATIONAL ELECTRICAL MANUFACTURERS
ASSOCIATION
NEUT OR N NEUTRAL
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NIC NOT IN CONTRACT
NL NIGHT LIGHT
NO NORMALLY OPEN
NS NO SCALE
NTS NOT TO SCALE
O
OC ON CENTER
OD OUTSIDE DIAMETER
OL OVERLOAD
P
P POLE
PA PUBLIC ADDRESS
PB PULL BOX OR PANEL BOARD
PBPU PREFABRICATED BEDSIDE PATIENT UNIT
PCB POLYCHLORINATED BIPHENYL
PEC PHOTOELECTRIC CELL
PED PEDESTAL
PEND PENDANT
PF POWER FACTOR
PH PHASE
PNL PANEL
PT POTENTIAL TRANSFORMER
PVC POLYVINYL CHLORIDE (PLASTIC)
PWR POWER
R
RCP REFLECTED CEILING PLAN
REC RECESSED
RECPT RECEPTACLE
REQ REQUIRED
RGS RIGID GALVANIZED STEEL
RM ROOM
RMS ROOT MEAN SQUARE
S
SCC SHORT CIRCUIT CAPACITY
SD SMOKE DETECTOR
SES SERVICE ENTRANCE SECTION
SF SQUARE FOOT (FEET)
SHT SHEET
SI INTERNATIONAL SYSTEM OF UNITS
SPEC SPECIFICATION
SPST SINGLE POLE, SINGLE THROW
SURF SURFACE
SW SWITCH
SWBD SWITCHBOARD
SWGR SWITCHGEAR
T
TEL TELEPHONE
TP TWISTED PAIR
TPS TWISTED PAIR SHIELDED
TTB TELEPHONE TERMINAL BOARD
TV TELEVISION
TYP TYPICAL
U
UFD UNDERFLOOR DUCT
UGND UNDERGROUND
UL UNDERWRITERS LABORATORY
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTIBLE POWER SUPPLY
UTIL UTILITY
V
V VOLT
VA VOLT-AMPERE
VAR VOLT-AMPERE REACTIVE
VFD VARIABLE FREQUENCY DRIVE
VOLT VOLTAGE
W
W WATT
WH WATER HEATER
WP WEATHERPROOF
X
XFER TRANSFER
XFMR TRANSFORMER
DPDT DOUBLE POLE, DOUBLE THROW
DPST DOUBLE POLE, SINGLE THROW
DRSW DOOR SWITCH
DS DISCONNECT SWITCH
DWG DRAWING
E
EL ELEVATION
ELEC ELECTRIC OR ELECTRICAL
ELEV ELEVATOR
EMCP EMERGENCY MONITORING CONTROL PANEL
EMER EMERGENCY
EMI ELECTROMAGNETIC INTERFERENCE
EMT ELECTRICAL METALLIC TUBING
ENCL ENCLOSURE
EPO EMERGENCY POWER OFF
EPRF EXPLOSION PROOF
ESMT EASEMENT
EWC ELECTRIC WATER COOLER
EWH ELECTRIC WATER HEATER
EXST EXISTING
F
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FABL FIRE ALARM BELL
FABX FIRE ALARM BOX
FACP FIRE ALARM CONTROL PANEL
FC FOOTCANDLE
FIXT FIXTURE
FLA FULL LOAD AMPS
FLEX FLEXIBLE METALLIC CONDUIT
FLT FLOODLIGHT
FLUOR FLUORESCENT
FLUOR FIXT FLUORESCENT FIXTURE
FOUTT TELEPHONE FLOOR OUTLET
FP FIRE PROTECTION
FT FEET OR FOOT
FU SW FUSED SWITCH
FVNR FULL VOLTAGE NON-REVERSING
FVR FULL VOLTAGE REVERSING
G
G OR GND ELECTRICAL GROUND
GC GENERAL CONTRACTOR
GEN GENERATOR
GFCI GROUND FAULT CIRCUIT INTERRUPTER
GTB GROUND TERMINAL BOX
H
HID HIGH INTENSITY DISCHARGE
HOA HAND-OFF-AUTOMATIC
HP HORSEPOWER
HT HEIGHT
HZ HERTZ
I
IESNA ILLUMINATION ENGINEERING SOCIETY OF NORTH
AMERICA
IMC INTERMEDIATE METAL CONDUIT
INCAND INCANDESCENT
IR INFRARED
IWH INSTANTANEOUS WATER HEATER
J
J-BOX JUNCTION BOX
K
KV KILOVOLT
KVA KILOVOLT-AMPERE
KVAH KILOVOLT-AMPERE PER HOUR
KVAR KILOVOLT-AMPERE REACTIVE
KW KILOWATT
KWH KILOWATT HOUR
KWHM KILOWATT HOUR METER
L
LED LIGHT EMITTING DIODE
LF LINEAR FEET (FOOT)
LM LUMEN
LP LIGHT POLE
LPS LOW PRESSURE SODIUM
LRA LOCKED ROTOR AMPS
LT LIGHT
LTG LIGHTING
LTG PNL LIGHTING PANEL
LTNG LIGHTNING
LV LOW VOLTAGE
M
MATV MASTER ANTENNA TELEVISION SYSTEM
MAX MAXIMUM
MC METAL-CLAD
MCA MINIMUM CIRCUIT AMPS
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MDP MAIN DISTRIBUTION PANEL
MECH MECHANICAL
MG MOTOR GENERATOR
MH MANHOLE
1P SINGLE POLE
1PH SINGLE PHASE
2/C TWO-CONDUCTOR
3/C THREE-CONDUCTOR
3PH THREE PHASE
4/C FOUR-CONDUCTOR
4W FOUR WIRE
A
A/C UNIT AIR CONDITIONING UNIT
A/E ARCHITECT / ENGINEER
AAP ALARM ANNUNCIATOR PANEL
AC ALTERNATING CURRENT OR ARMORED CABLE
ACC ACCESSIBLE
ADDL ADDITIONAL
ADJ ADJACENT OR ADJOINING
ADO AUTOMATIC DOOR OPENER
AF AMPERE FRAME OR AMP FUSE
AFC ABOVE FINISHED COUNTER, AUTOMATIC
FREQUENCY CONTROL, OR AVAILABLE FAULT
CURRENT
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AH AMPERE-HOUR
AHJ AUTHORITY HAVING JURISDICTION
AIC AMPERE INTERRUPTING CAPACITY
ALT ALTERNATE
AMB OR A AMBIENT
AMP AMPERE
ARCH ARCHITECT
ASC AMPS SHORT CIRCUIT
AT AMPERE TRIP
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AV AUDIO VISUAL
B
BAT BATTERY
BC BARE COPPER
BD BOARD
BFF BELOW FINISHED FLOOR
BIL BASIC INSULATION LEVEL
BLDG BUILDING
BPIP BOILER PLANT INSTRUMENTATION PANEL
BRKR BREAKER
BYP BYPASS
C
C CONDUIT
CAB CABINET
CALC CALCULATE
CAP CAPACITY
CAT CATALOG
CATV COMMUNITY ANTENNA TELEVISION
CCR CONTROL CONTACTOR
CCTV CLOSED CIRCUIT TELEVISION
CD CANDELA OR CONSTRUCTION DOCUMENTS
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR FURNISHED / CONTRACTOR
INSTALLED
CF/OI CONTRACTOR FURNISHED / OWNER INSTALLED
CFE CONTRACTOR FURNISHED EQUIPMENT
CHW CHILLED WATER
CHWP CHILLED WATER PUMP
CKT CIRCUIT
CKT BRKR CIRCUIT BREAKER
CLF CURRENT LIMITING FUSE
CLG CEILING
CMU CONCRETE MASONRY UNIT
CO CONTRACTING OFFICER
COAX COAX CABLE
COMM COMMUNICATION
COMPT COMPARTMENT
CONC CONCRETE
CONT CONTINUE
CONTR CONTRACTOR
COORD COORDINATE
COR CONTRACTING OFFICER'S REPRESENTATIVE
CPT CONTROL POWER TRANSFORMER
CRI COLOR RENDERING INDEX
CT CURRENT TRANSFORMER
CTV CABLE TELEVISION
CU COPPER
CU FT CUBIC FEET
CUR CURRENT
D
DB DECIBEL
DC DIRECT CURRENT
DCP DIMMER CONTROL PANEL
DEG C DEGREES CELSIUS
DEG F DEGREES FAHRENHEIT
DEMO DEMOLITION
DIAG DIAGRAM
DISC DISCONNECT
DISTR DISTRIBUTION
DISTR PNL DISTRIBUTION PANEL
DMR SW DIMMER SWITCH
DN DOWN
ELECTRICAL ABBREVIATIONS
FIELD COORDINATE CAMERA TYPES AND MOUNTING HARDWARE IN CONJUNCTION TO THE MOUNTING APPLICATIONS AND LOCATION - VERIFY CORRECT INTRA-CONNECT CABLEING WITH DEVICE TYPES AND
LOCATION
SC SECURITY CONTRACTOR
EC ELECTRICAL
CONTRACTOR
COMMUNICATION GENERAL NOTESCOMMUNICATION GENERAL NOTES
VA DIVISION 27 COMMUNICATIONS
VA DIVISION 28 ELECTRONIC SAFETY AND SECURITY
A BASIS OF DESIGN MAY DETERMINE MANUFACTURER AND PRODUCT USED IN CONJUNCTION TO EXISTING
CONDITIONS AND COMMON SYSTEMS UTILIZED BY THE OVERALL FACILITY, OIT AND SECURITY
DEPARTMENTS. ALL LOW VOLTAGE BIDDERS SHALL BE INVITED TO SURVEY THE SITE CONDITIONS PRIOR TO
ESTIMATING:
REF. VA OIT INFRASTRUCTURE STANDARDS FOR TELECOMMUNICATIONS SPACES.
VEG 4.14
595-17-101
1700 S. LINCOLN AVE; LEBANON, PA 17042
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
CONSULTANTS: ARCHITECT/ENGINEERS: STAMP: 100% CONSTRUCTION
DOCUMENTS
PHYSICAL SECURITY
IMPROVEMENTS
of 5012/04/2019 TL AMP E-002
N/A
ELECTRICAL SYMBOLS
CR
ES
F
FIX
J
ML
RRB
RX
WS
DB
CB
NCM
NWS
WAP
C
W
I
S
X
S
X
R
R
M
C
NCM
NCT
N
D
N
R
M
TTB
VFD
G
R
A
V
W
WH
T
T T
J
PB
P
S
HVS
LVS
P
T
D
DP#__
LP
C
TC
W W
B B
C
S
H
S
X
B
X
M
COMMUNICATION SYMBOLS:
CARD READER
ELECTRIC DOOR STRIKE
MAGNETIC DOOR POSITION SWITCH
VANDAL RESISTANT 1080P DOME IP CAMERA
FOUR SQUARE JUNCTION BOX
MAGNETIC LOCK
USP HUB2SA REMOTE DOOR RELEASE BUTTON
REQUEST TO EXIT MOTION DETECTOR
CCTV SYSTEM WORKSTATION
DURESS BUTTON
CODE BLUE BUTTON INTEGRATED NURSE CALL SYSTEM
NURSE CALL MASTER CONSOLE
ETHERNET NETWORK SWITCH
WIRELESS ACCESS POINT
DATA BOX
OUTLET, COMBINATION TELEPHONE/DATA
COMMUNICATION
CABLE TELEVISION LINE = CATV
CLOSED CIRCUIT TELEVISION LINE = CCTV. MINIMUM
1" CONDUIT
FIBER OPTICS LINE = FO
TELEPHONE LINE = T
INTERCOM & PUBLIC ADDRESS LINE = I. MIN. 3/4" CONDUIT.
SOUND LINE = S
NURSE CALL LINE = NC. MINIMUM 3/4" CONDUIT.
RADIO CONDUIT RUN, MINIMUM 3/4" CONDUIT.
TELECOMMUNICATIONS MANHOLE
FLOOR RECEPTACLE, TELEPHONE
OUTLET TELEPHONE; LETTER INDICATES AS FOLLOWS:
J = JACK TYPE W = WALL TYPE
OUTLET DATA ONLY ; NUMBER OF OUTLETS REPRESENTED
OUTLET DATA AND TELECOM
OUTLET; LETTER INDICATES AS FOLLOWS:
A = AUDIO V = VIDEO I = INTERCOM
SPEAKER, CEILING MOUNTED, "X" INDICATES THE TYPE,
PROVIDE SCHEDULE ON LEGEND
SPEAKER, WALL MOUNTED, "X" INDICATES THE TYPE,
PROVIDE SCHEDULE ON LEGEND. MTD.
7'-6" AFF UNLESS OTHERWISE NOTED.
RADIO CHANNEL SELECTOR FACILITIES, MTD. 4'-6"
AFF UNLESS OTHERWISE NOTED.
SPEAKER PROGRAM SELECTOR SWITCH & VOLUME
CONTROL MTD. 4'-6" AFF UNLESS OTHERWISE NOTED.
OUTLET, TELEVISION
BLANK= 4 11/16" MASTER ANTENNA OUTLET BOX W/BLANK
COVER, MTD. 18" AFF UNLESS OTHERWISE NOTED.
C = CAMERA (CCTV SYSTEM), MTD 18" AFF
M = MONITOR (CCTV SYSTEM).
NURSE'S CALL MASTER STATION MTD ON NURSE'S COUNTER
TOP UNLESS OTHERWISE NOTED.
NURSE CALL TERMINAL CABINET.
NURSE CALL STATION.
2 = DUPLICATE FACILITIES FOR TWO BEDS (SEPARATE INDICATORS
AT MASTER STATION) MTD 5'-0" AFF UNLESS OTHERWISE NOTED.
D = DUTY STATION. MTD 5'-0" AFF UNLESS NOTED OTHERWISE.
E = MTD 6'-0" AFF FOR SHOWER LOCATION, MTD 4'-6" AFF FOR
TUBLOCATION, & MTD 3'-0" AFF FOR TOILET LOCATION.
P = PSYCHIATRIC CORRIDOR STATION WITH KEY SWITCH
S = AUDIO VISUAL WALL STATION (STAFF) MTD 5'-0" AFF UNLESS
OTHERWISE NOTED.
U = UTILITY CALL STATION, MTD 5'-0" AFF UNLESS OTHERWISE
NOTED.
NURSE CALL STATION.
2 = NURSE'S CALL DOME LIGHT (SUFFIX INDICATES No OF LAMP)
MTD 6" ABOVE DOOR.
D = CORRIDOR DOME LIGHT.
I = AUXILIARY INTERSECTIONAL DOME LIGHT.
TELEPHONE TERMINAL CABINET
TELEPHONE BACKBOARD (WALL MOUNTED)
3-POLE TWIST-LOCK RECEPTACLE FOR MICROPHONE, MTD. 4'-6" AFF.
REMOTE DICTATING OUTLET MTD 1'-6" AFF. UNLESS OTHERWISE
NOTED.
INTERCOM STATION (REFER TO SPECS. FOR FUNCTIONAL OPERATION
OF INSTRUMENT & TYPE REQUIRED).
P
CATV
CCTV
FO
T
I
S
NC
R
ELECTRICAL SYMBOLS - DIAGRAM
DELTA CONNECTION.
MOTOR, SINGLE-PHASE.
MOTOR, THREE-PHASE.
TRANSFORMER.
WYE CONNECTION.
PULL BOX.
MANHOLE.
PRESSURE SWITCH-CLOSE ON
INCREASE.
PRESSURE SWITCH-OPEN ON
INCREASE.
SWITCH, MULTIPOSITION.
SWITCH, NORMALLY CLOSED FLOAT.
SWITCH, NORMALLY CLOSED FOOT OPERATED.
SWITCH, NORMALLY CLOSED LIMIT.
SWITCH, NORMALLY CLOSED TEMPERATURE
ACTIVATED.
SWITCH, NORMALLY CLOSED TIME DELAY.
SWITCH, NORMALLY OPEN FLOAT.
SWITCH, NORMALLY OPEN LIMIT.
SWITCH, NORMALLY OPEN TEMPERATURE
ACTIVATED.
SWITCH, NORMALLY OPEN TIME DELAY.
SWITCH, SINGLE BREAK.
NORMALLY CLOSED RELAY CONTACT.
NORMALLY OPEN RELAY CONTACT.
FUSE WITH RATING.
MOLDED CASE CIRCUIT BREAKER.
LOW-VOLTAGE DRAWOUT AIR CIRCUIT
BREAKER.
MEDIUM-VOLTAGE OIL CIRCUIT BREAKER.
MEDIUM-VOLTAG DRAWOUT AIR CIRCUIT
BREAKER.
SWITCH AND FUSE UNIT.
FUSED DRAWOUT POTENTIAL TRANSFORMER.
RELAY; LETTER INDICATES RELAY TYPE.
50 = INSTANTENOUS OVERCURRENT OR RATE-
OF-RISE.
51 = AC-TIME OVERCURRENT.
67 = AC-DIRECTIONAL OVERCURRENT.
86 = LOCK OUT.
DISCONNECT SWITCH, FUSED.
DISCONNECT SWITCH, UNFUSED, VAV.
FUSIBLE LINK.
STARTER, COMBINATION W/ DISCONNECT
SWITCH.
STARTER OR MOTOR CONTROLLER.
VARIABLE FREQUENCY DRIVE.
GENERATOR, POWER.
BATTERY.
CAPACITOR.
POTHEAD.
STRESS CONE.
LIGHTNING ARRESTOR.
RECTIFIER, CATHODIC PROTECTION.
AMMETER.
VOLTMETER.
WATTMETER.
WATT-HOUR METER.
TRANSFORMER, PLAN.
WYE CONNECTION.
DUCT, CELL FLOOR HEADER.
DUCT, TROLLEY.
DUCT, UNDERFLOOR JUNCTION BOX.
EARTH GROUND.
JUNCTION BOX.
LADDER CABLE TRAY.
ELECTRICAL SYMBOLS - POWER PLAN
BRANCH CIRCUIT HOMERUN. LINES INDICATE NUMBER OF
CIRCUITS,NEUTRAL, AND SWITCH LEG CONDUCTORS. ONE
SEPARATE GREEN GROUNDING CONDUCTOR SHALL BE
PROVIDED FOR EACH HOMERUN; NOT SHOWN.
WIREWAY.
RIGID CONDUIT LINE = RC.
DIRECT BURIAL CABLE = DB.
POWER DUCT = P.
SUBSTATION.
HI VOLTAGE SWITCH ON CONCRETE PAD.
LOW VOLTAGE SWITCH ON CONCRETE PAD.
DUAL POWER AND TELECOMMUNICATIONS MANHOLE.
FLOOR OUTLET, RECEPTACLE.
BUSWAY.
FLOOR OUTLET, DATA COMMUNICATION.
OUTLET, DATA COMMUNICATION.
PUSH BUTTON.
DISTRIBUTION PANEL.
LIGHTING PANEL.
PANELBOARD CABINET, FLUSH MOUNTED.
PANELBOARD CABINET, SURFACE MOUNTED.
GROUNDING BAR.
RECEPTACLE, CLOCK HANGER.
RECEPTACLE, DUPLEX (MOUNT 18" AFF. UNLESS NOTED
OTHERWISE).
RECEPTACLE, DUPLEX ON EMERGENCY POWER (MOUNT 18"
AFF. UNLESS NOTED OTHERWISE).
RECEPTACLE, DUPLEX WITH GROUND FAULT CIRCUIT
INTERRUPTER (MOUNT 18" AFF. UNLESS NOTED
OTHERWISE), COUNTER HEIGHT.
RECEPTACLE, DUPLEX COUNTER HEIGHT.
RECEPTACLE, QUADRAPLEX.
RECEPTACLE, SINGLE.
RECEPTACLE, SINGLE WITH SWITCH.
RECEPTACLE, QUADRAPLEX ON EMERGENCY POWER
(MOUNT 18" AFF. UNLESS NOTED OTHERWISE).
RECEPTACLE, SPECIAL PURPOSE
A = 120V, 20A, 1 PHASE, 2-POLE, 3W, NEMA 5-20R.
B = 120V, 20A, 1 PHASE, 2-POLE, 3W, NEMA 6-20R.
C = 120V, 30A, 1 PHASE, 2-POLE, 3W, NEMA 5-30R.
D = 208V, 30A, 1 PHASE, 2-POLE, 3W, NEMA 6-30R.
E = 208V, 60A, 1 PHASE, 3-POLE, 4W, NEMA 14-60R.
F = 208V, 30A, 3 PHASE, 3-POLE, 4W, NEMA 15-30R.
G = 208V, 50A, 3 PHASE, 3-POLE, 4W, NEMA 15-30R.
H = 208V, 60A, 3 PHASE, 3-POLE, 4W, NEMA 15-30R.
RECEPTACLE, CEILING MOUNTED
RECEPTACLE, SWITCHED DUPLEX.
DROP CORD, SINGLE CONVENIENCE OUTLET, 3-WIRE,
GROUNDING TYPE, 20A, W/#12 CONDUCTORS IN FLEXIBLE
CORD (CENTER LINE OF OUTLET: 6'-6" AFF. MIN).
ELECTRICAL STRIPLE MOLD (OUTLETS ON 2'-0" CENTERS OR
AS DESIGNATED ON DRAWINGS), MTD 3'-6" AFF. OR AS
INDICATED.
3-GANG COMPARTMENT BOX IN FLOOR FOR TELEPHONE,
DATA & RECEPTACLE.
TIME CLOCK.
VENTILATOR OR FAN COIL UNIT OUTLET.
CONDUIT TERMINATED 6" AFF. IN STANDARD BOX FOR
EXTENSION TO EQUIPMENT AS DIRECTED.
CONDUIT TERMINATED W/ COUPLING (FLUSH W/ FINISHED
FLOOR) FOR EXTENSION TO EQUIPMENT AS DIRECTION.
SWITCH
F = FUSED SWITCH.
K = KEY OPERATED.
L = LOCK.
LM = LOW VOLTAGE MASTER.
M = MANUAL MOTOR STARTING.
MC = MOMENTARY CONTACT.
MP = MOTOR SNAP WITH PILOT LIGHT.
P = WITH PILOT LIGHT (THERMAL TYPE).
X = EXPLOSION PROOF.
BLANK OUTLET BOX.
HEADWALL.
RC
DB
P
ELECTRICAL SYMBOLS - LIGHTING PLAN
SWITCH (# SUBSCRIPT AS INDICATED BELOW):
BLANK = SINGLE POLE
LVD = LOW VOLTAGE DIMMER
LV= LOW VOLTAGE SWITCH
GS= GRAPHIC SCREEN CONTROL STATION
PB= PUSH BUTTON STATION
WP= WEATHER PROOF
T = TIMER OPERATED
LOS= OCCUPANCY SENSOR
RECESSED DOWNLIGHT FIXTURE.
NOMENCLATURE EXAMPLE :
('A' DESIGNATES LIGHT FIXTURE TYPE, 'b' DESIGNATES SWITCHLEG, x DESIGNATES CIRCUIT NUMBER) REFER
TO
DRAWINGS AND LIGHT FIXTURE SCHEDULE FOR MORE
INFORMATION.
RECESSED TROFFER LIGHT FIXTURE.
NOMENCLATURE EXAMPLE :
('A' DESIGNATES LIGHT FIXTURE TYPE, 'b' DESIGNATES SWITCHLEG, x DESIGNATES CIRCUIT NUMBER) REFER
TO
DRAWINGS AND LIGHT FIXTURE SCHEDULES FOR MORE
INFORMATION.
CEILING SURFACE MOUNTED LIGHT FIXTURE.
NOMENCLATURE EXAMPLE :
('A' DESIGNATES LIGHT FIXTURE TYPE, 'b' DESIGNATES SWITCHLEG, x DESIGNATES CIRCUIT NUMBER) REFER
TO
DRAWINGS AND LIGHT FIXTURE SCHEDULE FOR MORE
INFORMATION.
WALL SURFACE MOUNTED LIGHT FIXTURE.
NOMENCLATURE EXAMPLE :
('A' DESIGNATES LIGHT FIXTURE TYPE, 'b' DESIGNATES SWITCHLEG, x DESIGNATES CIRCUIT NUMBER) REFER
TO
DRAWINGS AND LIGHT FIXTURE SCHEDULE FOR MORE
INFORMATION.
LIGHT FIXTURE POWER CONNECTION DESIGNATIONS:
OPEN - NORMAL POWER CIRCUIT
SHADED - LIFE SAFETY EMERGENCY POWER CIRCUIT
HATCHED - CRITICAL POWER CIRCUIT
DUAL PASSIVE INFRARED / MICROPHONIC TECHNOLOGY
(ULTRASONIC NOT ALLOWED)
EXIT SIGN, WALL MOUNTED WITH DIRECTIONAL
ARROWS AND FACES AS SHOWN
EXIT SIGN, CEILING MOUNTED WITH DIRECTIONAL
ARROWS AND FACES AS SHOWN
LIGHTING, ONE HEAD EMERGENCY BATTERY
POWER
LIGHTING, TWO HEAD EMERGENCY BATTERY
POWER
LIGHTING, THREE HEAD EMERGENCY BATTERY
POWER
STREET LIGHT WITH BRACKET
LIGHT POLE, ONE MAST ARM, ONE LUMINAIRE
LIGHT POLE, TWO MAST ARMS, TWO LUMINAIRES
LIGHT POLE, POST TOP MOUNT LUMINAIRE
LIGHT POLE, ONE LUMINAIRE
LIGHT POLE, TWO LUMINAIRES
LIGHTING, EXTERIOR BUILDING
EXTERIOR FLOOD LIGHT
LIGHT FIXTURE, BOLLARD
LIGHT FIXTURE, DIRECTIONAL
DT
A bx
A b x
A b x
A b x
OUTLET DATA ONLY ; NUMBER OF OUTLETS REPRESENTED
GFCI
RECEPTACLE, DUPLEX (MOUNT 18" AFF. UNLESS NOTED
OTHERWISE).
C
LIGHT EXTERIOR BUILDING MOUNTED FIXTURE
POST TOP MOUNTED LIGHT FIXTURE
12/04/2020 TL AMP
ES101
9 & 102
BUILDINGS 9 & 102 - ELECTRICAL
AND SECURITY SITE PLAN
VEG 4.14
595-17-101
1700 S. LINCOLN AVE; LEBANON, PA 17042
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
CONSULTANTS: ARCHITECT/ENGINEERS: STAMP: 100% CONSTRUCTION
DOCUMENTS
PHYSICAL SECURITY
IMPROVEMENTS
of 50
GENERAL NOTES:
KEYNOTES:
BUILDING
1. ELECTRICAL CONTRACTOR SHALL PROVIDE NEW 20A/3P
INVERSE TIME BREAKER IN SIGN PANEL TO MATCH
EXISTING MANUFACTURER, TYPE AND AIC RATING.
2. ELECTRICAL CONTRACTOR SHALL PROVIDE (3#12 & 1 #12 G)
1" PVC CONDUIT UNDERGROUND TO GATE CONTROLLER
LOCATION. CONDUIT SHALL BE BURIED MINIMUM 30" BELOW
GRADE.
3. ELECTRICAL CONTRACTOR SHALL REMOVE EXISTING 20A/
1P BREAKERS IN CIRCUITS 79, 81 & 83 OF PANEL PP2-2 IN
ROOM 125 AND TURN OVER TO OWNER.
4. ELECTRICAL CONTRACTOR SHALL PROVIDE NEW 20A/3P
5. INVERSE BREAKER IN PANEL PP2-2 CIRCUITS 79, 81, & 83.
NEW BREAKER MUST MATCH EXISTING MANUFACTURER,
TYPE, AND AIC RATING.
6. ELECTRICAL CONTRACTOR SHALL PROVIDE (3#12 & 1#12 G)
1"C THRU CRAWL SPACE AND UNDERGROUND TO GATE
CONTROLLER. INTERIOR CONDUIT SHALL BE EMT,
TRANSITIONING TO PVC BURIED MINIMUM 30" BELOW
GRADE.
7. ELECTRICAL CONTRACTOR SHALL PROVIDE NEW 1'
CONDUIT SLEEVE AND LB THROUGH EXTERIOR WALL
THROUGH CRAWL SPACE WALL TO TRANSITION TO
UNDERGROUND INSTALLATION.
8. EC TO PROVIDE (1) 1-1/4 INCH SCHEDULE 80 UG PATHWAY
FOR COMMUNICATIONS CABLING BY THE SECURITY
CONTRACTOR. REFERENCE KEY NOTE 6 AND COORDINATE
TRENCHING FOR BOTH ELECTRICAL AND
TELECOMMUNICATIONS INFRASTRUCTURE. TRANSITIONS
EXTERIOR PATHWAY INTO BUILDING TO INTERIOR 1-1/4
INCH EMT AND EXTEND TO THE NEAREST IT ROOM 121.
UTILIZE CABLE TRAY IF AVAILABLE OR ALIGN CONDUIT
WITH LIKE SYSTEMS.
9. CARD ACCESS AND 2-WAY PUSH TO TALK INTERCOM.
REFER TO SHEET E-502, DETAILS 3 & 4.
10. EC TO PROVIDE (1) 1-1/4 INCH SCHEDULE 80 UG PATHWAY
FOR COMMUNICATIONS CABLING BY THE SECURITY
CONTRACTOR. COORDINATE TRENCHING & DIRECTIONAL
BORING FOR BOTH ELECTRICAL AND
TELECOMMUNICATIONS INFRASTRUCTURE.
11. PROVIDE HAND HOLES FOR ACCESS TO UP PATHWAYS.
12. TRANSITION EXTERIOR PATHWAY INTO BUILDING 9 TO
INTERIOR 1-1/4 INCH EMT AND EXTEND TO THE NEAREST IT
ROOM (TBD). UTILIZE CABLE TRAY IF AVAILABLE OR ALIGN
CONDUIT WITH LIKE SYSTEMS.
13. REFER TO DETAIL 2 SHEET E-502 FOR GROUNDING
REQUIREMENTS AND MINIMUM CONDUIT REQUIREMENTS.
14. SECURITY CONTRACTOR TO PROVIDE ONE (1) 2-STRANDS
RATED INDOOR/OUTDOOR RATED, 50 MIC MULTIMODE
FIBER OPTIC CABLE FROM THE NEAREST IT CLOSET.
UTILIZE LOCAL CLASS 2 TRANSFORMER AT THE CAMERA
FOR POWER. COORDINATE LOCAL POWER SOURCE WITH
THE ELECTRICAL LIGHTING CONTRACTOR.
15. PHOTO-EYE AND RADIAL LOOP DETAIL ON SHEET E-502.
SCALE:
2' 4' 8' 16' 32'
1/8" = 1'-0"
ELECTRICAL SITE PLAN - BUILDING 102
EXISTING OXYGEN TANK
P l a n
N o r t h
T r r t h
A. FOR ELECTRICAL SYMBOLS, ABBREVIATIONS AND
GENERAL NOTES, REFER TO SHEETS E-001 AND E-002.
B. ALL CONDUITS SHALL CONTAIN NYLON PULL STRING.
C. PROVIDE UPDATED TYPE WRITTEN PANEL DIRECTORY.
D. ENSURE PANEL IS NOT OVERLOADED WITH ADDITIONAL
LOAD.
E. REFER TO SPECIFICATION SECTION 312011 FOR EARTH
WORK REQUIREMENTS.
F. CONTRACTORS TO PERFORM UTILITY CHECK FOR ANY
UNDERGROUND CONFLICT WITH NEW WORK AND
RE-ROUTE AROUND ANY UNDERGROUND UTILITIES.
G. CONDUIT SHOULD BURIED AT A MINIMUM DEPTH OF 24".
UNDER GRASS AND 30". UNDER ROADWAY PROVIDE
ADDITIONAL DEPTH TO MEET ANY NEC BENDING RADIUS
REQUIREMENTS.
ROOM 125
P l a n
N o r t h
T r r t h
BUILDING
SCALE:
2' 4' 8' 16' 32'
1/8" = 1'-0"
ELECTRICAL SITE PLAN - EMERGENCY/DELIVERY GATE
P
B
P
I
Z
CC1
SCALE:
2' 4' 8' 16' 32'
1/8" = 1'-0"
PERIMETER HARDENING - GENERATOR FARM
12/04/2020 JC AMP
ES102
NA
ELECTRICAL AND SECURITY SITE
PLAN
VEG 4.14
595-17-101
1700 S. LINCOLN AVE; LEBANON, PA 17042
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
CONSULTANTS: ARCHITECT/ENGINEERS: STAMP: 100% CONSTRUCTION
DOCUMENTS
PHYSICAL SECURITY
IMPROVEMENTS
of 50
GENERAL NOTES:
KEYNOTES:
SCALE:
2' 4' 8' 16' 32'
1/8" = 1'-0"
PERIMETER HARDENING - PROPANE TANK
P l a n
N o r t h
T r r t h
P l a n
N o r t h
T r r t h
(E) BURIED FUEL LINES, TO REMAIN;
FIELD VERIFY EXACT LOCATION
1. FIELD VERIFY EXACT POSITIONING WITH THE VA COR
PRIOR TO START. SC TO ALIGN/MOUNT FIXED CAMERA
TO LIGHT POLE. EC TO PROVIDE MINIMUM 1-INCH
CONDUIT FROM BELOW GROUND TO 4-11/16 BACK BOX
FOR CAMERA MOUNTING HARDWARE.
2. EC TO PROVIDE SCHEDULE 80 UG PATHWAY FOR
COMMUNICATIONS CABLING BY THE SECURITY
CONTRACTOR. FIELD COORDINATED TRENCHING &
DIRECTIONAL BORING FOR BOTH ELECTRICAL AND
TELECOMMUNICATIONS INFRASTRUCTURE. REFER TO
DIV. SPECIFICATIONS.
3. PROVIDE HANDS HOLES FOR ACCESS TO UG
PATHWAYS EVERY 150 FEET.
4. EXTEND UG/OSP PATHWAY TO BUILDING 3, IT CLOSET.
REFER TO SHEET ES104 FOR CONTINUATION. FIELD
COORDINATE EXACT PATHWAY/ROUTE WITH THE VHA
PRIOR TO START.
5. LOCATE ALL UTILITIES BEFORE YOU DIG.
6. PROVIDE (2#10 & 1#12G) 1" PVC CONDUIT FROM SPARE
BREAKER IN CIRCUIT 9 OF PANEL AX AND TERMINATE
TO FIXTURE HEAD THROUGH POLE.
7. PROVIDE (2#10 & 1#12G) 1" PVC CONDUIT FROM SPARE
BREAKER IN CIRCUIT 11 OF PANEL AX AND TERMINATE
TO FIXTURE HEAD THROUGH TUBE/POLE.
8. INTERCEPT EXISTING LIGHTING CIRCUIT PANEL AX-7,
AND EXTEND WIRE AND CONDUIT TO EXTERIOR
BUILDING MOUNTED FIXTURES AS SHOWN.
9. PROVIDE 8"X8"X6" PULL BOX FOR UNDERGROUND
CONDUITS.
10. BOND METAL TUBE POLE TO GROUND PER NEC WITH
A. RE: AS001 FOR SITE LOCATION.
B. FOR ELECTRICAL SYMBOLS, ABBREVIATIONS AND
GENERAL NOTES, REFER TO SHEETS E-001 AND E-002.
C. ALL CONDUIT SHALL CONTAIN NYLON PULL STRING.
D. PROVIDE UPDATED TYPE WRITTEN PANEL DIRECTORY.
E. ENSURE PANEL IS NOT OVERLOADED WITH ADDITIONAL
LOAD.
F. REFER TO SPECIFICATION SECTION 312011 FOR EARTH
WORK REQUIREMENTS.
2 3
TO GENERATOR YARD
PANEL AX-9
(TYP)
TO PROPAN
POL
TO PR
TANK CA
#6 AWG COPPER CONDUCTOR.
11. BOND METAL TUBE GATE POST TO GROUND PER NEC
WITH #2/0 AWG BARE STRANDED COPPER CONDUCTOR.
12. SECURITY CONTRACTOR TO PROVIDE ONE (1) 2-STRANDS
INDOOR/OUTDOOR RATED , 50 MIC MULTIMODE FIBER
OPTIC CABLE FROM THE NEAREST IT CLOSET. UTILIZE
LOCAL CLASS 2 TRANSFORMER AT CAMERA FOR POWER.
COORDINATE LOCAL POWER SOURCE WITH ELECTRICAL
LIGHTING CONTRACTOR.
BB1
BB2
(TYP).
NE TANK
E LIGHT
PB
DD1
BB2
EXISTING
PANEL AX
DD1
OPANE
AMERA
(TYP).
BB2
1/8" = 1'-0"
WATER TOWER PROTECTION
12/04/2020 JC AMP
ES103
NA
ELECTRICAL AND SECURITY SITE
PLAN
VEG 4.14
595-17-101
1700 S. LINCOLN AVE; LEBANON, PA 17042
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
CONSULTANTS: ARCHITECT/ENGINEERS: STAMP: 100% CONSTRUCTION
DOCUMENTS
PHYSICAL SECURITY
IMPROVEMENTS
of 50
GENERAL NOTES:
KEYNOTES:
1. FIELD COORDINATE EXACT CAMERA MOUNTING HEIGHTS WITH
THE VHA PRIOR TO START. EC TO PROVIDE 4-11/16 BOX AND
CONNECT/STUB THROUGH 1-INCH EMT CONDUIT TO THE NEAREST
IT CLOSET (TBD). UTILIZE CABLE TRAY IF AVAILABLE OR PARALLEL
EXISTING PATHWAYS FOR LIKE SYSTEMS. FURNISH (1) CAT 6A
CONNECTION.
2. FIELD VERIFY EXACT CAMERA POSITIONING WITH THE VHA PRIOR
TO START. SC TO ALIGN/MOUNT FIXED CAMERA TO FENCE POST
OR LIGHT POST (TBD).
3. EC TO PROVIDE SCHEDULE 80 UG PATHWAY FOR
COMMUNICATIONS CABLING BY THE SECURITY CONTRACTOR.
FIELD COORDINATE TRENCHING AND DIRECTIONAL BORING FOR
BOTH ELECTRICAL AND TELECOMMUNICATIONS
INFRASTRUCTURE. REFER TO DIV. SPECIFICATIONS. REFER TO
ES104 DETAIL 2.
4. PROVIDE HAND HOLES FOR ACCESS TO UG PATHWAYS EVERY 150
FEET.
5. EXTEND UG-OSP PATHWAY TO BUILDING 25 (UON), IT CLOSET.
REFER TO SHEET ES104 FOR CONTINUATION. FIELD COORDINATE
EXACT PATHWAY/ROUTE WITH THE VHA PRIOR TO START.
6. LOCATE ALL UTILITIES BEFORE YOU DIG.
7. INTERCEPT EXISTING WATER TOWER BOLLARD FLOOD LIGHTING
CIRCUIT AND EXTEND WIRE AND CONDUIT UNDERGROUND TO
NEW POLE LOCATION AND TERMINATE POWER TO NEW POLE
MOUNTED LIGHT.
8. SECURITY CONTRACTOR TO PROVIDE ONE (1) 2-STRANDS
INDOOR/OUTDOOR RATED, 50 MIC MULTIMODE FIBER OPTIC
CABLE FROM THE NEAREST IT CLOSET.UTILIZE LOCAL CLASS 2
TRANSFORMER AT THE CAMERA FOR POWER. COORDINATE
LOCAL POWER SOURCE WITH ELECTRICAL LIGHTING
CONTRACTOR.
P l a n
N o r t h
T r r t h
P l a n
N o r t h
T r r t h
SCALE:
2' 4' 8' 16' 32'
1/8" = 1'-0"
GAS LINE PROTECTION
BUILDING
A. RE: AS001 FOR SITE LOCATION.
B. FOR ELECTRICAL SYMBOLS, ABBREVIATIONS AND GENERAL NOTES,
REFER TO SHEETS E-001 AND E-002.
C. ALL CONDUITS SHALL CONTAIN NYLON PULL STRING.
D. PROVIDE UPDATED TYPE WRITTEN PANEL DIRECTORY.
E. ENSURE PANEL IS NOT OVERLOADED WITH ADDITIONAL LOAD.
F. REFER TO SPECIFICATION SECTION 312011 FOR EARTH WORK
REQUIREMENTS.
AA1
HAND RAIL
PEDESTAL
NEW WATER TANK
BASE CONE
1/8" = 1'-0"
BUILDING 104 EXTERIOR
01/22/2021 JC AMP
ES104
NA
BUILDINGS 104 - ELECTRICAL AND
SECURITY SITE PLAN
VEG 4.14
595-17-101
1700 S. LINCOLN AVE; LEBANON, PA 17042
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
CONSULTANTS: ARCHITECT/ENGINEERS: STAMP: 100% CONSTRUCTION
DOCUMENTS
PHYSICAL SECURITY
IMPROVEMENTS
of 50
GENERAL NOTES:
KEYNOTES:
1. PROVIDE A CONCRETE BASE SIMILAR TO SHEET E-504, DETAIL 6;
RE: LS101 FOR ADDITIONAL INFORMATION
A. RE: AS001 FOR SITE LOCATION.
B. FOR ELECTRICAL SYMBOLS, ABBREVIATIONS AND GENERAL
NOTES, REFER TO SHEETS E-001 AND E-002.
C. ALL CONDUIT S SHALL CONTAIN NYLON PULL STRING.
D. PROVIDE UPDATED TYPE WRITTEN PANEL DIRECTORY.
E. ENSURE PANEL IS NOT OVERLOADED WITH ADDITIONAL LOAD.
F. REFER TO SPECIFICATIONS SECTION 312011 FOR EARTH WORK
REQUIREMENTS.
INTERCEPT EXISTING LIGHT POST'S
CIRCUIT, EXTEND CIRCUIT TO NEW
SIDEWALK LIGHTS.
EE1
EE1
P l a n
N o r t h
T r r t h
1/8" = 1'-0"
BUILDING 3
12/04/2020 JC AMP
ES105
BUILDING 3 - ELECTRICAL AND
SECURITY SITE PLAN
VEG 4.14
595-17-101
1700 S. LINCOLN AVE; LEBANON, PA 17042
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
CONSULTANTS: ARCHITECT/ENGINEERS: STAMP: 100% CONSTRUCTION
DOCUMENTS
PHYSICAL SECURITY
IMPROVEMENTS
of 50
GENERAL NOTES:
KEYNOTES:
1. EC TO PROVIDE (1) 1-1/4 INCH SCHEDULE 80 UG PATHWAY FOR
COMMUNICATIONS CABLING BY THE SECURITY CONTRACTOR.
REFERENCE SHEET ES102 AND FIELD COORDINATE
TRENCHING/DIRECTIONAL BORING FOR BOTH ELECTRICAL AND
TELECOMMUNICATIONS INFRASTRUCTURE TO THE GENERATOR
FARM AND THE PROPANE TANK, REFER TO DIV. SPECIFICATIONS.
REFER TO ES102 DETAIL 1 AND 2.
2. PROVIDE HAND HOLES FOR ACCESS TO UG PATHWAYS EVERY 150
FEET.
3. LOCATE ALL UTILITIES BEFORE YOU DIG.
4. TRANSITION EXTERIOR PATHWAY INTO BUILDING 3 INTERIOR
UTILIZING 1-1/4 INCH EMT AND EXTEND TO THE NEAREST IT ROOM
(TBD). UTILIZE CABLE TRAY IF AVAILABLE OR PARALLEL EXISTING
PATHWAYS FOR LIKE SYSTEMS. FURNISH FIBER OPTIC
CONNECTION BETWEEN EACH CAMERA AND THE TELECOM ROOM.
5. FIELD COORDINATE EXACT CAMERA MOUNTING HEIGHTS WITH THE
VHA PRIOR TO START. EC TO PROVIDE 4-11/16 BOX AND
CONNECT/STUB THROUGH 1-INCH EMT CONDUIT TO THE NEAREST
IT CLOSET (TBD). UTILIZE CABLE TRAY IF AVAILABLE OR PARALLEL
EXISTING PATHWAYS FOR LIKE SYSTEMS FURNISH CAT6
CONNECTION BEWEEN EACH CAMERA AND THE TELECOM ROOM..
6. EC TO PROVIDE (1) 1-1/4 INCH SCHEDULE 80 UG PATHWAY FOR
COMMUNICATIONS CABLING BY THE SECURITY CONTRACTOR.
REFERENCE SHEET ES103 AND FIELD COORDINATE
TRENCHING/DIRECTIONAL BORING FOR BOTH ELECTRICAL AND
TELECOMMUNICATIONS INFRASTRUCTURE TO THE WATER TOWER.
REFER TO DIV. SPECIFICATIONS. REFER TO ES103 DETAIL 1
7. TRANSITION EXTERIOR PATHWAY INTO BUILDING 25 INTERIOR
UTILIZING 1-1/4 INCH EMT AND EXTEND TO THE NEAREST IT ROOM
(TBD). UTILIZE CABLE TRAY IF AVAILABLE OR PARALLEL EXISTING
PATHWAYS FOR LIKE SYSTEMS FURNISH FIBER OPTIC
CONNECTION BETWEEN THE CAMERA AND THE TELECOM ROOM.
P l a n
N o r t h
T r r t h
A. RE: AS001 FOR SITE LOCATION.
B. FOR ELECTRICAL SYMBOLS, ABBREVIATIONS AND GENERAL
NOTES, REFER TO SHEETS E-001 AND E-002.
C. ALL CONDUIT S SHALL CONTAIN NYLON PULL STRING.
D. PROVIDE UPDATED TYPE WRITTEN PANEL DIRECTORY.
E. ENSURE PANEL IS NOT OVERLOADED WITH ADDITIONAL LOAD.
F. REFER TO SPECIFICATIONS SECTION 312011 FOR EARTH WORK
REQUIREMENTS.
BUILDING
SCALE:
2' 4' 8' 16' 32'
1/8" = 1'-0"
BUILDING 25
P l a n
N o r t h
T r r t h
2 3 6
BUILDING
G009
300C13-1
300C17-1
EXISTING CARD READER, PROVIDE UPGRADE TO HIGH PRIORITY
ACCESS.
ACTIVATE PRE-WIRED PACS READER.
PROVIDE NEW HIGH PRIORITY SECURITY ACCESS.
EXISTING CARD READER, PROVIDE UPGRADE TO MEDIUM
PRIORITY ACCESS.
ELECTRICAL GENERAL NOTES:
VEG 4.14
595-17-101
1700 S. LINCOLN AVE; LEBANON, PA 17042
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
CONSULTANTS: ARCHITECT/ENGINEERS: STAMP: 100% CONSTRUCTION
DOCUMENTS
PHYSICAL SECURITY
IMPROVEMENTS
of 50
KEYNOTES:
06/19/2020 TL AMP
EI101
BUILDING 1 - ELECTRICAL
TECHNOLOGY
IT CLOSET
G011
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16'0
GROUND FLOOR, ROOMS 3 & 4
BLOOD DRAW/
WAITING ROOM
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16'0
FIRST FLOOR, ROOM #129
IT CLOSET 129
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16'0
THIRD FLOOR, ROOMS #353 & #389
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16'0
THIRD FLOOR, ROOM #330
IT
CLOSET
353 MED ROOM
330MEDS
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16'0
FOURTH FLOOR, ROOM #461
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16'0
FOURTH FLOOR, ROOM #423
CLOSET
461 MED
ROOM
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16'0
FIFTH FLOOR, ROOM #561
IT
CLOSET
A. FOR SYMBOLS, ABBREVIATIONS AND GENERAL NOTES, REFER TO
SHEETS E-001 AND E-002.
B. REFER TO A-001 FOR BUILDING 1 KEY PLANS.
P l r t h
T r r t h
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16'0
IT CLOSET #G011
P l r t h
T r r t h
P l a n
N o r t h
T r r t h
P l a n
N o r t h
T r r t h
P l a n
N o r t h
T r r t h
P l a n
N o r t h
T r r t h
P l a n
N o r t h
T r r t h
P l a n
N o r t h
T r r t h
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16'0
FOURTH FLOOR, ROOM #465
MEDS
P l a n
N o r t h
T r r t h
ROOM 003
DR
IDS
DR
IDS
DR
IDS
DR
IDS
ES
ES
ES
ES
ES
ES
ES
ES
ES
ES
ES
95% CONSTRUCTION DOCUMENTS - RE-SUBMIT 07/24/2020
95% CONSTRUCTION DOCUMENTS 06/19/2020
100% CONSTRUCTION DOCUMENTS 11/06/2020
1700 S. LINCOLN AVE; LEBANON, PA 17042
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
CONSULTANTS: ARCHITECT/ENGINEERS: STAMP: 100% CONSTRUCTION
DOCUMENTS
PHYSICAL SECURITY
IMPROVEMENTS
of 50
KEYNOTES:
12/04/2020 TL AMP
EI102
3, 4, 5
BUILDINGS 3, 4 & 5 - ELECTRICAL
TECHNOLOGY
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16'0
BUILDING 3 - BASEMENT
SCALE: 1/2" = 1'-0"
6" 1' 2' 4' 8'0
BUILDING 4 - SECOND FLOOR, IT CLOSET #203
SCALE: 1/2" = 1'-0"
6" 1' 2' 4' 8'0
BUILDING 5 - SECOND FLOOR, IT CLOSET #204
IT CLOSET
IT CLOSET
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16'0
BUILDING 3 - FIRST FLOOR
P l a n
N o r t h
T r r t h
P l a n
N o r t h
T r r t h
P l a n
N o r t h
T r r t h
P l a n
N o r t h
T r r t h
ENTRY
005A
101B
ENTRY
C
C2
C
C
EXISTING CARD READER, PROVIDE UPGRADE TO HIGH PRIORITY
ACCESS.
PROVIDE PACS - CYPHER CAPABLE (FOR UP 50+ USERS).
ACTIVATE EXISTING IDS.
PROVIDE AND INSTALL CCTV.
ELECTRICAL GENERAL NOTES:
A. FOR SYMBOLS, ABBREVIATIONS AND GENERAL NOTES, REFER TO
SHEETS E-001 AND E-002.
B. FOR BUILDING 3, BASEMENT; REFER TO A-102 FOR SITE PLAN,
DETAIL 4.
C. FOR BUILDING 3. FIRST FLOOR; REFER TO A-102 FOR SITE PLAN,
DETAIL3.
D. FOR BUILDING 4, REFER TO A-102 FOR SITE PLAN, DETAIL 2.
E. FOR BUILDING 5, REFER TO A-102 FOR SITE PLAN, DETAIL 1.
ES
ES
CLASSROOM
110 CLASSROOM
005006
STAIRS
005A
UP DN
DN
204 206
101A
102112
106C
116 106D
DN UP
106F
DN
206207
UP
595-17-101
1700 S. LINCOLN AVE; LEBANON, PA 17042
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
CONSULTANTS: ARCHITECT/ENGINEERS: STAMP: 100% CONSTRUCTION
DOCUMENTS
PHYSICAL SECURITY
IMPROVEMENTS
of 50
KEYNOTES:
12/04/2020 TL AMP
EI103
6, 7
BUILDINGS 6 & 7 - ELECTRICAL
TECHNOLOGY
EXISTING CARD READER, PROVIDE UPGRADE TO MEDIUM
PRIORITY ACCESS.
ACTIVATE EXISTING PACS CARD READER.
PROVIDE NEW MEDIUM PRIORITY SECURITY ACCESS.
A. FOR SYMBOLS, ABBREVIATIONS AND GENERAL NOTES REFER TO
SHEETS E-001AND E-002.
B. REFER TO A-103 FOR BUILDING 6 AND BUILDING 7 KEY PLANS.
ELECTRICAL GENERAL NOTES:
CMG
STORAGE
ENTRY
WAREHOUSE
105A
OFFICE
WAREHOUSE
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16'0
BUILDING 6
DOORS 101 AND 105
P l a n
N o r t h
T r r t h
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16'0
BUILDING 6
DOOR 105A1
P l a n
N o r t h
T r r t h
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16'0
BUILDING 6
DOORS 100 AND 107
P l a n
N o r t h
T r r t h
1 2
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16'0
BUILDING 7
FIRST FLOOR EXTERIOR DOORS
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16'0
BUILDING 7
BASEMENT EXTERIOR DOORS
P l a n
N o r t h
T r r t h
P l a n
N o r t h
T r r t h
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16'0
BUILDING 7
BASEMENT EXTERIOR DOORS
P l a n
N o r t h
T r r t h
ES ES
ES
ES
ES ES
ES
ES
ES
ES
ES
CARD READERS ARE NOT PERMITTED IN THE REQUIRED MEANS OF EGRESS (MOE)
FROM ROOMS, AREA, OR SPACES ON THE EGRESS SIDE VERSUS THE ACCESS SIDE.
A MOE PLAN SHOULD BE REVIEWED.
NOTE:
101A 105A1
WAREHOUSE
105A
105A2
UP
107101
UP
DN
VEG 4.14
595-17-101
1700 S. LINCOLN AVE; LEBANON, PA 17042
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Is…
This is the start of the file's text. The full file is on GovTribe.