Presolicitation Notice Presolicitation Notice
| SUBJECT* |
| Oculus Pentacam HR 70925-G Brand Name Only |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 15240 |
| SOLICITATION NUMBER* |
| 36C24422Q0710 |
| RESPONSE DATE/TIME/ZONE |
| 06-01-2022 12:00PM EASTERN TIME, NEW YORK, USA |
| ARCHIVE |
| 10 DAYS AFTER THE RESPONSE DATE |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| 6515 |
| NAICS CODE* |
| 339115 |
| PLACE OF PERFORMANCE |
| James E. Van Zandt |
Altoona VA Medical Center
2907 Pleasant Valley Boulevard
Altoona PA
| POSTAL CODE |
| 16602 |
| COUNTRY |
| USA |
CONTACT INFORMATION
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
Network Contracting Office 4 1010 Delafield Road Pittsburgh PA 15240
POINT OF CONTACT*
Contract Specialist Sherrie Thompson sherrie.thompson2@va.gov 724-679-2327
ADDITIONAL INFORMATION
| AGENCY’S URL |
| https://www.va.gov/altoona-health-care/ |
| URL DESCRIPTION |
| Altoona VA |
| AGENCY CONTACT’S EMAIL ADDRESS |
| sherrie.thompson2@va.gov |
| EMAIL DESCRIPTION |
| COntract Specialist |
DESCRIPTION
STATEMENT OF WORK
Statement of Need for: – Pentacam Introduction The Ophthalmology Clinic, at the James E Van Zandt Medical Center, 2907 Pleasant Valley BLVD, Altoona, PA 16602 has determined the need to Oculus Pentacam to measure the corneal thickness.
Justification:
The project shall require Oculus Pentacam to be delivered to the James E Van Zandt Medical Center which new Ophthalmologist is now on board. The Pentacam images the anterior segment of the eye by a rotating Scheimpflug camera measurement. This rotating process supplies pictures in three dimensions. The center of the cornea is measured very precisely because of this rotational imaging process. The measurement process lasts less than two seconds and minute eye movements are captured and corrected simultaneously. By measuring 25,000 true elevation points, precise representation, repeatability and analysis are guaranteed.
Salient Characteristics
· Qualitative assessment of the cornea:
· Topography and elevation data of the anterior and posterior corneal surface
· Overall pachymetry, absolute and relative
· Glaucoma screening:
· Pachymetry-based IOP correction
· Chamber angle, volume, and depth
· Topography based keratoconus detection and classification
· Comparative displays for progression control and follow-up
· Various comparative displays for extensive follow-up
· Pachymetric and topographic maps for individual health care measures
· Comprehensive refractive maps for transparent diagnostics
· Curvature values of the anterior and posterior corneal surface for improved IOL calculation
· Manual measurements can be taken in Scheimpflug images to determine position of IOLs, iris contours, implants, etc.
· True Net Power Map, determination of true refractive power of the cornea – even and after refractive surgery
· Pentacam Scheimpflug Camera,
· XYZ moveable base
· head and chin rest
· power supply
· USB cable
· dust cover
· electric height
· adjustable wooden
· design table
· 21.5" all-in- one computer incl. Windows
· wireless mouse
· mini-keyboard
· floating license key
· Includes Pachymetry Software, Densitometry Software
· 3-D Chamber
· Analyser Software
· Corneal Topography Software
· Belin-Ambrosio Enhanced Ectasia software
· Holladay Report
· Contact Lens Fitting Software
· 3D Cataract Analysis with Pentacam Nucleus
· Staging software
· Corneal Optical Densitometry
· Indices Report.
Performance Monitoring. Vendor must show competency of Oculus Pentcam
a. Packaging, Packing and Shipping Instructions. Equipment to be shipped 30 days within receipt of order
b. Inspection and Acceptance Criteria. Equipment will be inspected upon receipt and if no damages are incurred during shipping equipment will be accepted.
Include Manufacturer Warranty Delivery: 3-4 Weeks Delivery:
Delivery accepted at James E Van Zandt, Medical Center, 2907 Pleasant Valley BLVD, Altoona, PA 16602; Weekdays 8:00am – 2:00pm, excluding any government holidays.
End of Document