36C24421Q0774.docx

DOCX document 14 KB Posted

Attached to
6515--Sonosite PX ultrasound This is not a request for quote
Solicitation number
36C24421Q0774
Issued by

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Contract Opportunity Sources Sought Notice

PRODUCT SERVICE CODE

SUBJECT

CONTRACTING OFFICE'S

ZIP-CODE

SOLICITATION NUMBER

RESPONSE DATE/TIME/ZONE

ARCHIVE

DAYS AFTER THE RESPONSE DATE

RECOVERY ACT FUNDS

SET-ASIDE

NAICS CODE

CONTRACTING OFFICE

ADDRESS

POINT OF CONTACT

(POC Information Automatically Filled from User Profile Unless Entered)

DESCRIPTION

See Attachment

AGENCY'S URL

URL DESCRIPTION

AGENCY CONTACT'S EMAIL

ADDRESS

EMAIL DESCRIPTION

ADDRESS

POSTAL CODE

COUNTRY

ADDITIONAL INFORMATION

GENERAL INFORMATION

PLACE OF PERFORMANCE

* = Required Field Contract Opportunity Sources Sought Notice Sonosite PX ultrasound This is not a request for quote 19805 36C24421Q0774 06-09-2021 15:00

EASTERN TIME, NEW YORK, USA

N 339112 Department of Veterans Affairs Network Contracting Office 4 Contract Specialist LaShawn Knight lashawn.knight@va.gov Wilmington VA Medical Center 1601 Kirkwood Highway Wilmington

DE

19805

USA

https://www.wilmington.va.gov/ Wilmington VA Medical Center lashawn.knight@va.gov Contract Specialist THIS IS NOT A SOLICITATION ANNOUNCEMENT. THIS IS A REQUEST FOR INFORMATION ONLY. This Request for Information (RFI) is intended for information and planning purposes only at this time; and shall not be construed as a solicitation or as an obligation on the part of the Department of Veterans Affairs. Because this is a Request for Information announcement, no evaluation letters and/or results will be issued to the respondents.

No solicitation exists. Therefore, do not request a copy of a solicitation.

STATEMENT OF NEED

The Wilmington VAMC is planning to acquire ultrasound-imaging equipment for portable applications. The equipment must be capable of operating in B Mode, M-Mode, Color Doppler, Color Power Doppler (CPD), Pulsed Wave and Continuous Wave modes. It must support transducers with linear, phased, and curved array formats. Further, it must include a full array of measurement and calculation packages. The specific requirements for this equipment are the following:

System Specifications

1. Operating System: Windows 10 IoT Enterprise 2019 LTSC

2. Stand Dimensions width x depth): 28.3 x 28.3” (720 mm x 720 mm

3. Stand Height (max): 65” (1650 mm) monitor up

4. Stand Height (min): 42.2” (1072 mm) monitor down

5. Height Adjustment: 9.8” (24.9 mm) travel

6. 10 x 5.7” Projected Capacitive (PCAP) Touch Screen

7. Physical buttons

8. Control Panel Tilt Adjustment: 0° to 110°

9. Side to Side Turning: +/- 90 degrees from center

10. Monitor Tilt: 1 – 140 degrees

11. Work Surface angle – Horizontal position: 15 degrees from horizontal, Vertical position: 55 degrees from horizontal

12. Casters: 5” Swivel, 4 Locking

13. System Boot up: >20 secs

14. Clinical Monitor: 15.6 inches (39.6 cm x 14.5 cm), high definition monitor

15. Clinical Monitor Image Size: 8.1 inches x 6.1 inches (20.7 cm x 15.5 cm)

16. Clinical Monitor Display Size: 13.5 inches x 7.6 inches (34.4 cm x 19.4 cm)

17. Screen Resolution (minimum): Display – 1920 x 1080, Image – 1152 x 864

18. Architecture: All digital broadband

19. Gray Scale: 256 shades

20. Dynamic Range: Up to 183 dB

21. HIPAA Compliance: Meets Federal Information Processing Standards (FIPS) for Moderate security control selections per FIPS199, FIPS200, and NIST 800-53. More details in the Data Security section.

22. The system shall withstand a drop from a height of 1 meter. The system shall be safe and function normally after this drop.