36C24418B0604-003.pdf
PDF 14 MB Posted
- Attached to
- Provide Electronic Signage, NRM 503-17-103
- Solicitation number
- 36C24418B0604
About this file
36C24418B0604 Final Drawings_503-17-103_Provide Electronic Signage.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24418B0604-0002000.docx | DOCX document | |
| 36C24418B0604-0001002.pdf | ||
| 36C24418B0604-0001000.docx | DOCX document | |
| 36C24418B0604-0001001.pdf | ||
| 36C24418B0604-0001003.pdf | ||
| 36C24418B0604-002.pdf | ||
| 36C24418B0604-004.docx | DOCX document | |
| 36C24418B0604-006.docx | DOCX document | |
| 36C24418B0604-005.docx | DOCX document | |
| 36C24418B0604-001.docx | DOCX document | |
| 36C24418B0604-000.docx | DOCX document |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONSULTANTS:
Drawing Title
Approved:
Project Title:
Location:
Date: Checked: Drawn:
Drawing Number
Dwg. of
Building Number
Project Number
Office of Construction and Facilities Management
VA FORM 08-6231
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
A
B
C
D
E
F
6 " o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t
209 SANDUSKY STREET
PITTSBURGH, PA 15212
PH: 412.287.7333
www.ae-works.com
AE WORKS PROJECT NUMBER:
ARCHITECTS/ENGINEERS:SEAL
Revision# Date
5/ 7/
1:
:3
A
M JEVZ MEDICAL CENTER -
ELECTRONIC SIGNAGE
503-17-103
BK SH
2907 Pleasant Valley Blvd, Altoona, PA 16602
G001
COVER SHEET
05/07/2018 20 17033
BID DOCUMENTS
100% SUBMISSION
PROVIDE ELECTRONIC
SIGNAGE
JAMES E. VAN ZANDT VA MEDICAL CENTER
2907 PLEASANT VALLEY BLVD.
ALTOONA, PA 16602
VICINITY MAP
SITE
LOCATION MAP
SITE
PROJECT DIRECTORY
OWNER:
JAMES E. VAN ZANDT VA MEDICAL CENTER
2907 PLEASANT VALLEY BLVD.
ALTOONA, PA 16602
(814) 943-8164
CONTACT: NICHOLAS A. CHABON PE, PMP
ARCHITECT/ENGINEER:
AE WORKS, LTD
209 SANDUSKY STREET
PITTSBURGH, PA 15206
(412) 287-7333
CONTACT: STEVE HORVATH
DRAWING INDEX
SHEET # SHEET NAME
E001 ELECTRICAL SYMBOLS, ABBREVIATIONS, NOTES AND SHEET INDEX
01-E10B BUILDING 1 - BASEMENT PLAN
01-E101 BUILDING 1 - FIRST FLOOR PLAN
01-E102 BUILDING 1 - SECOND FLOOR PLAN
01-E103 BUILDING 1 - THIRD FLOOR PLAN
01-E104 BUILDING 1 - FOURTH FLOOR PLAN
01-E105 BUILDING 1 - FIFTH FLOOR PLAN
01-E106 BUILDING 1 - SIXTH FLOOR PLAN
01-E107 BUILDING 1 - SEVENTH FLOOR PLAN
G001 COVER SHEET
02-E101 BUILDING 2 - FIRST FLOOR PLAN
03-E101 BUILDING 3 - FIRST FLOOR PLAN
07-E101 BUILDING 7 - FIRST FLOOR PLAN
22-E101 BUILDING 22 - FIRST FLOOR PLAN
32-E101 BUILDING 32 - FIRST FLOOR PLAN
D-E201 CBOC - DUBOIS FLOOR PLAN
H-E601 CBOC - HUNTINGDON FLOOR PLAN
I-E501 CBOC - INDIANA FLOOR PLAN
J-E301 CBOC - JOHNSTOWN FLOOR PLAN
SC-E401 CBOC - STATE COLLEGE FLOOR PLAN
E701 SYSTEM RISER DIAGRAM AND GENERAL DETAILS
SEALSEAL
RECEPTACLES, FURNITURE FEEDS
THE ABOVE MOUNTING ELEVATIONS ARE TO CENTER OF DEVICE AND SHALL BE ADHERED
TO UNLESS SPECIFICALLY NOTED OR DETAILED OTHERWISE ON THE DRAWINGS AND/OR
SPECIFICATIONS.
IN FLOOR JUNCTION BOXES FLUSH TO
FINISHED FLOOR (FF)
IN MASONRY CONSTRUCTION THE MOUNTING HEIGHTS SHALL BE USED FOR REFERENCE TO
THE NEAREST BLOCK OR BRICK COURSING.
COORDINATE THE INSTALLATION AND MOUNTING ELEVATIONS OF ALL EQUIPMENT, DEVICES,
CONTROLS AND APPURTENANCES WITH ARCHITECT AND ALL AFFECTED TRADES PRIOR TO
INSTALLATION. DOCUMENT ALL MOUNTING ELEVATIONS FOR ALL EQUIPMENT, DEVICES,
CONTROLS AND APPURTENANCES AT THE TIME OF SHOP DRAWING SUBMITTAL.
3.
2.
1.
0'-0"
1'-5" A.F.F.
STANDARD MOUNTING HEIGHTS
RECESSED LIGHTING FIXTURES, CEILING
MOUNTED RECEPTACLES, INDICATING LIGHTS,
ETC.
CEILING
ABOVE COUNTER DEVICES, GFI RECEPTACLES IN
RESTROOMS.
3'-6" A.F.F.
WALL SWITCHES, THERMOSTATS, CONTROL DEVICES,
TO CENTER OF BOX
4'-0" A.F.F.
TOP OF PANELBOARDS (<6'-0" TALL)6'-0" A.F.F.
TOP MOST PORTION OF OPERATING HANDLE OF
DISCONNECT SWITCHES / CIRCUIT BREAKERS
6'-6" A.F.F.
WALL MOUNTED LIGHTS IN STAIRS, MECH ROOMS,
ETC.
7'-0" A.F.F.
REVISION TRIANGLE WITH REVISION CLOUD
INDICATED MOUNTED ABOVE COUNTERTOP (REFER TO STANDARD
MOUNTING HEIGHTS DETAIL ON THIS SHEET)
X - Y
RECEPTACLE TAG:
X= PANEL NAME
Y= CIRCUIT NUMBER
ADA INSTALLATION GUIDELINES
34"
46"
MAX.
(NOTE #2)
44"
MAX.
(FOR 20-25")
(NOTE #2)
10-24" 25" MAX.
48"
MAX.
(FOR 20")
(NOTE #2)
OBSTRUCTED HIGH
SIDE REACH
OBSTRUCTED HIGH
FORWARD REACH
48"
MAX.
(NOTE #2)
10"
MAX.
15"
MIN.
48"
MAX.
(NOTE #2)
15"
MIN.
OBSTRUCTED
SIDE REACH
OBSTRUCTED
FORWARD REACH
NOTES:
1. THESE GUIDLINES SHALL BE USED FOR THE INSTALLATION OF THE FOLLOWING
DEVICES:
- WALL SWITCHES
-CONTROL SWITCHES
-RECEPTACLES
-VISUAL DISPLAY TOUCH PANELS
2. NOTE THAT THIS HEIGHT IS TO THE TOP-MOST PART OF THE DEVICE THAT AN
OCCUPANT REQUIRES ACCESS TO.
ANNOTATION SYMBOLS
DRAWING KEYNOTE - PLAN / ELEVATION NEW WORK1
AREA OF WORK
N NEW DEVICE
E EXISTING DEVICE
APPLICABLE CODES AND STANDARDS
1. LIFE SAFETY CODE - NFPA 101, 2015
2. INTERNATIONAL BUILDING CODE - IBC, 2015
3. NATIONAL ELECTRICAL CODE - NFPA 70, 2017
4. HEALTHCARE FACILITIES CODE - NFPA 99, 2012
5. VA DESIGN REQUIREMENTS
A. ELECTRICAL DESIGN MANUAL FOR NEW HOSPITALS, REPLACEMENT HOSPITALS,
AMBULATORY CARE CLINICAL ADDITIONS, ENERGY CENTERS, OUTPATIENT CLINICS,
ANIMAL RESEARCH FACILITIES, LABORATORY BUILDINGS – DECEMBER 1, 2015
B. FIRE PROTECTION DESIGN MANUAL – DECEMBER 2015
C. TELECOMMUNICATIONS AND SPECIAL TELECOMMUNICATIONS SYSTEMS DESIGN
MANUAL – FEBRUARY 1, 2016
ELECTRICAL SYMBOLS LEGEND
DUPLEX RECEPTACLE IN A 4" SQUARE BOX WITH PLASTER RING (IN DRYWALL)
SINGLE GANG BOX IN MASONRY.
DOUBLE DUPLEX RECEPTACLE IN A 4" SQUARE BOX
NEW FIRE RATED SLEEVE. ALL PENETRATIONS OF WALLS AND/OR FLOORS
SHALL BE FIRE STOPPED IN ACCORDANCE WITH THE ASTM AND NFPA
REQUIREMENTS FOR 2-HOUR FIRE RATING. REFER TO RELATED
SPECIFICATION SECTIONS FOR ADDITIONAL INFORMATION. INSTALLATION OF
FIRE-STOPS SHALL BE PERFORMED BY APPLICATOR/INSTALLER QUALIFIED AND
TRAINED BY THE MANUFACTURER. INSTALLATION SHALL BE PERFORMED IN
STRICT ACCORDANCE WITH MANUFACTURER'S DETAILED INSTALLATION
PROCEDURES.
WALL MOUNTED DATA OUTLET - PROVIDE DOUBLE GANG BACKBOX W/ SINGLE
GANG DEVICE RING, 1 1/4" EMT CONDUIT W/ PULLSTRING TO ABOVE
ACCESSIBLE CEILING.
SYSTEMS SYMBOLS LEGEND
NEW CATEGORY 6 UTP CABLE - PLENUM RATED
TV TELEVISION/MONITOR WITH HDMI CONNECTION
CONSULTANTS:
Drawing Title
Approved:
Project Title:
Location:
Date: Checked: Drawn:
Drawing Number
Dwg. of
Building Number
Project Number
Office of Construction and Facilities Management
VA FORM 08-6231
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
A
B
C
D
E
F
6 " o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t
209 SANDUSKY STREET
PITTSBURGH, PA 15212
PH: 412.287.7333
www.ae-works.com
AE WORKS PROJECT NUMBER:
ARCHITECTS/ENGINEERS:SEAL
Revision# Date
5/ 4/
:1
9:
P M
JEVZ MEDICAL CENTER -
ELECTRONIC SIGNAGE
503-17-103
BK SH
2907 Pleasant Valley Blvd, Altoona, PA 16602
E001
ELECTRICAL SYMBOLS, ABBREVIATIONS,
NOTES AND SHEET INDEX
05/07/2018 201 17033
BID DOCUMENTS
100% SUBMISSION
SP STANDPIPE OR STATIC PRESSURE
SPC SPECIMEN PASS-THRU CABINET
SPEC SPECIFICATIONS
SPS STATIC PRESSURE SENSOR
SR SERVICE RECEPTOR
SS SOIL STACK
ST PR STATIC PRESSURE
ST STL STAINLESS STEEL
STD STANDARD
STER STERILIZER
STL STEEL
STOR STORAGE
STR STRAINER
STRUCT STRUCTURAL
SUSP SUSPENDED
SW SWITCH
SWBD SWITCHBOARD
SWGR SWITCHGEAR
SYM SYMMETRICAL TOP
T TOP
TA THROWAWAY
TAN TANGENT
TC TELECOMMUNICATIONS
CONTRACTOR
TCV TEMPERATURE CONTROL VALVE
TDV TRIPLE DUTY VALVE
TEL TELEPHONE
TEMP TEMPERATURE
TER TERRAZZO
TG TONGUE & GROOVE
TH THERMOMETER
THRES THRESHOLD
TR TEMPERATURE RISE
TRANS TRANSITION
TRANSR TRANSFORMER
TSTAT THERMOSTAT
TV TURNING VANES OR TELEVISION
TYP TYPICAL
UC UNDER CABINET OR UNDER CUT
UFD UNDER FLOOR DUCT
UG UNDERGROUND
UH UNIT HEATER
UL UNDERWRITER'S LABORATORIES
UNFIN UNFINISHED
UNO UNLESS NOTED OTHERWISE
UPS UNINTERRUPTIBLE POWER SUPPLY
UTIL UTILITY
V VOLT
VAL VALVE
VD VOLUME DAMPER
VENT VENTILATION
VERT VERTICAL
VFS VENTURI FLOW STATION
VIF VERIFY IN FIELD
VL VENT LINE
VR VAPOR RETARDER
VS VENT STACK
VTR VENT THROUGH ROOF
W WATT
W/ WITH
W/O WITHOUT
WB WET BULB
WC WALL COVERING
WCL WATER CLOSET
WD WOOD
WF WIDE FLANGE
WFMD WATER FLOW MEASURING DEVICE
WG WALL GUARD OR WATER GAUGE
WHCH WHEEL CHAIR
WIN WINDOW
WMS WIRE MESH SCREEN
WP WEATHERPROOF
WPS WALL PROTECTION SYSTEM
WSCT WAINSCOT
WT WINDOW TREATMENT
WTD WATER TEMPERATURE DROP
WWF WELDED WIRE FABRIC
X DEMO
XN TO BE RELOCATED / NEW LOCATION
XR EXISTING TO REMAIN
ZVB ZONE VALVE BOX
ZVC ZONE VALVE CABINET
LAT LEAVING AIR TEMPERATURE
LAV LAVATORY
LB POUND
LDB LEAVING DRY BULB
LED LIGHT EMITTING DIODE
LF LINEAR FEET
LIN LINEAR
LOC LOCATION OR LOCATE
LPT LOW POINT
LSDC LINEAR SUPPLY DIFFUSER CEILING
LT LIGHT
LTG LIGHTING
LV LOW VOLTAGE
LVR LOUVER
LWB LEAVING WET BULB
LWC LINEAR WOOD CEILING
LWT LEAVING WATER TEMPERATURE
MAN MANUAL
MAT MIXED AIR TEMPERATURE
MATL MATERIAL
MAV MANUAL AIR VENT
MAX MAXIMUM
MBH ONE THOUSAND BTU / HOUR
MC MECHANICAL CONTRACTOR
MC METAL CLAD CABLE
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MDP MAIN DISTRIBUTION PANEL
MECH MECHANICAL
MEMB MEMBRANE
MET METAL
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MLO MAIN LUGS ONLY
MO MASONRY OPENING
MOD MOTOR OPERATED DAMPER
MONO MONOLITHIC
MTD MOUNTED
MTG HT MOUNTING HEIGHT
MTL METAL
MTLH METAL HALIDE
MTR MOTOR
MTS MANUAL TRANSFER SWITCH
MV MEDIUM VOLTAGE
N/A NOT APPLICABLE
NEC NATIONAL ELECTRIC CODE
NEMA NATIONAL ELECTRICAL
MANUFACTURER ASSOCIATION
NIC NOT IN CONTRACT
NL NIGHT LIGHT
NO NUMBER OR NORMALLY OPEN
NOM NOMINAL
NTS NOT TO SCALE
O OXYGEN
OA OUTSIDE AIR
OBD OPPOSED BLADE DAMPER
OC ON CENTER
OD OUTSIDE DIAMETER
OPER OPERATED
OPNG OPENING
OPP OPPOSITE
ORD OVERFLOW ROOF DRAIN
PB PULL BOX
PC PLUMBING CONTRACTOR
PD PUMP DISCHARGE
PG PRESSURE GAUGE WITH COCK
PL PROPERTY LINE
PLAM PLASTIC LAMINATE
PLBG PLUMBING
PNL PANEL
PR PAIR
PRD PRESSURE DIFFERENTIAL VALVE
PRELIM PRELIMINARY
PRT PRESSURE TAP
PRV PRESSURE REDUCING VALVE
PT PAINT OR POTENTIAL
TRANSFORMER
RO ROUGH OPENING
QT QUARRY TILE
R RADIUS
RA RETURN AIR / RELIEF AIR
RB RUBBER BASE
RC REMOVE COMPLETELY
RD ROOF DRAIN
RE RELOCATE EXISTING
REC RECESSED
RECPT RECEPTACLE
REF REFERENCE
REFL REFLECTOR
REG REGISTER
REINF REINFORCING
REM REMOVE
REQD REQUIRED
RET RETURN
REV REVISE
REX REMOVE EXISTING
RF RESILIENT FLOOR
RFI REQUEST FOR INFORMATION
RGS RIGID GALVANIZED STEEL CONDUIT
RH ROOF HATCH
RM ROOM
RN REMOVE AND REPLACE WITH NEW
RR REMOVE AND REPLACE
RS RAPID START
RV RELIEF VALVE
RWC RAIN WATER CONDUCTOR
SA SUPPLY AIR
SAN SANITARY SEWER ABOVE GROUND
SAN-BXR SANITARY SEWER - BURIED
EXISTING TO REMAIN
SAN-XR SANITARY SEWER ABOVE GROUND -
EXISTING TO REMAIN
SCHED SCHEDULE
SD SMOKE DAMPER OR SMOKE
DETECTOR
SDISP SOAP DISPENSER
SF SQUARE FOOT
SHT SHEET
SHT MTL SHEET METAL
SHTG SHEATHING
SIM SIMILAR
SM SURFACE MOUNTED
SNC SANITARY NAPKIN CABINET
SND SANITARY NAPKIN DISPOSER
EF EXHAUST FAN
EIFS EXTERIOR INSULATION AND
FINISHING SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEC CAB ELECTRICAL CABINET
ELEV ELEVATOR
EMER EMERGENCY
ENCL ENCLOSURE
ENTR ENTRANCE
EO ELECTRICAL OUTLET
EQ EQUAL
EQUIP EQUIPMENT
ETR EXISTING TO REMAIN
EWB ENTERING WET BULB
EWC ELECTRIC WATER COOLER
EWT ENTERING WATER TEMPERATURE
EX EXAUST AIR
EXH EXHAUST
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
XP EXPLOSION PROOF
F/S FIRE / SMOKE DAMPER
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FACP FIRE ALARM CONTROL PANEL
FAT FINAL AIR TEMPERATURE
FB FIRE BLANKET
FC FLEXIBLE CONNECTION OR
FOOTCANDLE
FD FLOOR DRAIN OR FIRE DAMPER
FDN FOUNDATION
FDV FIRE DEPARTMENT VALVE
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FH FIRE HOSE
FHC FIRE HOSE CABINET
FHP FULL HEIGHT PARTITION
FHV FIRE HOSE VALVE
FIN FINISH
FIXT FIXTURE
FL FLOW LINE
FLA FULL LOAD AMPERES
FLASH FLASHING
FLEX FLEXIBLE
FLG FLANGE
FLG C FLANGE CONNECTION
FLR FLOOR
FLUOR FLUORESCENT
FP FIRE PROOFING
FRMG FRAMING
FS FLOOR SINK
FSTOP FIRESTOPPING
FT FOOT / FEET
FT HD FEET OF HEAD
FTC FOOTCANDLES
FTG FOOTING
FUR FURRING
G GAS OR ELECTRICAL GROUND
GA GAUGE
GAL GALLONS
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACTOR
GEN GENERATOR
GENL GENERAL
GFCI GROUND FAULT CIRCUIT
INTERRUPTOR
GL GLASS
GLV GLOBE VALVE
GND GROUND
GPM GALLONS PER MINUTE
GR GRADE
GRAV GRAVITY
GRD BM GRADE BEAM
GV GATE VALVE
GWB GYPSUM BOARD
H HIGH
HB HOSE BIB
HC HEATING CONTRACTOR
HDCP HANDICAP
HDR HEADER
HDW HARDWARE
HID HIGH INTENSITY DISCHARGE
HM HOLLOW METAL
HORIZ HORIZONTAL
HP HORSE POWER
HPD HIGH PRESSURE DRIP
HPF HIGH POWER FACTOR
HR HANDRAIL
HSKP HOUSEKEEPING
HT HEIGHT
HTG HEATING
HTR HEATER
HV HIGH VELOCITY
HVAC HEATING, VENTILATING, AIR
CONDITIONING
HW HOT WATER
HWD HARD WOOD
HWR HOT WATER RETURN
HWS HOT WATER SUPPLY
HWS&R HOT WATER SUPPLY AND RETURN
HZ HERTZ
ID INSIDE DIAMETER
IER INVERTED ECCENTRIC REDUCER
IG ISOLATED GROUND
IME INSULATED METAL ENCLOSURE
IN INCH
INCAND INCANDESCENT
INCL INCLUDED
INSUL INSULATION
INT INTERIOR
INTERL INTERLOCK
INV INVERT
ISO ISOLATION
IVS ISOLATED VALVE STATION
J-BOX JUNCTION BOX
JST JOIST
JT JOINT
KO KNOCK OUT
kVA KILOVOLT AMPERE kVAR KILOVAR (REACTANCE) kW KILOWATT kWH KILOWATT HOUR METER
& AND
A AIR (CLINICAL)
AAP ALARM ANNUNCIATOR PANEL
AAV AUTOMATIC AIR VENT
AB ANCHOR BOLT
ABV ABOVE
ACC DR ACCESS DOOR
ACFL ACCESS
ACOUS ACOUSTICAL
ACT ACOUSTICAL CEILING TILE
AD AREA DRAIN
ADA AMERICAN DISABILITIES ACT
ADD ADDENDUM
ADDL ADDITIONAL
ADJ ADJUSTABLE
ADMIN ADMINISTRATION
AFF ABOVE FINISH FLOOR
AFG ABOVE FINISHED GRADE
AFMD AIR FLOW MEASURING DEVICE
AHU AIR HANDLING UNIT
AL ALIGN
ALT ALTERNATE
ALUM ALUMINUM
AMP AMPERE
AP ACCESS PANEL
APC ARCHITECTURAL PRECAST
CONCRETE
APPROX APPROXIMATE
ARCH ARCHITECTURAL
ASY ASYMMETRIC
ATC AUTOMATIC TEMPERATURE
CONTROL
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AWT AVERAGE WATER TEMPERATURE
BAT BATTERY
BC BALANCING COCK OR BARE
COPPER
BDD BACKDRAFT DAMPER
BFC BELOW FINISH CEILING
BFE BOTTOM FOOTING ELEVATION
BFG BELOW FINISHED GRADE
BG BUMPER GUARD
BLDG BUILDING
BLKG BLOCKING
BLT BORROWED LIGHT
BLW BELOW
BM BEAM
BO BY OWNER
BOF BY OWNER FUTURE
BOT BOTTOM
BR BRICK
BRG BEARING
BRKR BREAKER
BSMT BASEMENT
BTWN BETWEEN
BUR BUILT UP ROOFING
C CONDUIT
CAB CABINET
CANTL CANTILEVER
CAP CAPACITY
CATV CABLE TELEVISION
CCT CUBICLE CURTAIN TRACK
CCTV CLOSED CIRCUIT TELEVISION
CFH CUBIC FEET / HOUR
CFM CUBIC FEET / MINUTE
CH CHANNEL
CHK V CHECK VALVE
CHWR CHILLED WATER RETURN
CHWS CHILLED WATER SUPPLY
CHWS&R CHILLED WATER SUPPLY AND
RETURN
CJ CONTROL JOINT
CKT CIRCUIT
CKT BRKR CIRCUIT BREAKER
CL CENTERLINE
CLG CEILING
CLG MTD CEILING MOUNTED
CLR CLR
CMU CONCRETE MASONRY UNIT
CO CLEAN OUT
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUE / CONTINUOUS
CONTR CONTRACTOR
CONV CONVECTOR
COORD COORDINATE
CORR CORRIDOR
CPT CARPET OR CONTROL POWER
TRANSFORMER
CT CERAMIC TILE
CTR CENTER
CU COPPER
CV CONTROL VALVE
CW COLD WATER
D DEPTH OR DEEP
DB DRY BULB
dB DECIBEL
DCW DOMESTIC COLD WATER
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAILS
DF DRINKING FOUNTAIN
DHW DOMESTIC HOT WATER
DIA DIAMETER
DIAG DIAGONAL OR DIAGRAM
DIFF DIFFUSER
DIM DIMENSION
DISC DISCONNECT
DISCH DISCHARGE
DISP DISPENSER
DIST DISTRIBUTION
DIV DIVISION
DL DOWN LIGHT
DN DOWN
DP DISTRIBUTION PANEL
DPR DAMPER
DR DRAIN
DS DOWNSPOUT
DWG DRAWING
DX DIRECT EXPANSION
EA EXHAUST AIR
EAT ENTERING AIR TEMPERATURE
EC ELECTRICAL CONTRACTOR
EDB ENTERING DRY BULB
ABBREVIATION LEGEND ELECTRICAL GENERAL NOTES
1 THE FOLLOWING GENERAL NOTES AS LISTED BELOW SHALL APPLY TO ALL ELECTRICAL REQUIREMENTS AS INDICATED ON ALL E SERIES CONTRACT DRAWINGS.
2 THE CONTRACTOR IS RESPONSIBLE FOR THE ENTIRE DOCUMENT SET. IF WORK IS SHOWN ON OTHER DRAWINGS AS "BY CONTRACTOR" THE CONTRACTOR IS
RESPONSIBLE FOR THAT WORK.
3 DRAWINGS FOR THIS WORK ARE DIAGRAMMATIC AND INTENDED TO CONVEY THE EXTENT, GENERAL ARRANGEMENT AND LOCATIONS OF THE WORK. BECAUSE OF THE SCALE OF THE DRAWINGS, CERTAIN BASIC ITEMS SUCH AS ACCESS PANELS, CONDUITS, CABINET SIZES, PENETRATION SLEEVES, PULL BOXES, BACKBOXES AND JUNCTION BOXES MAY NOT BE SHOWN. INCLUDE ALL ITEMS WHERE REQUIRED BY CODE, MANUFACTURER AND RELATED SPECIFICATION
SECTIONS FOR THE PROPER INSTALLATION OF ALL WORK.
4 DUE TO SCALE OF THE DRAWINGS, ALL ELECTRICAL DEVICE SYMBOLS ARE SHOWN ON DRAWINGS AS CLOSE AS POSSIBLE TO THEIR INTENDED LOCATION.
CONTRACTOR SHALL COORDINATE IN THE FIELD THE PROPER INSTALLATION OF ALL EQUIPMENT, DEVICES, CONTROLS AND CONDUITS. REFER TO RELATED
SPECIFICATION SECTIONS FOR ADDITIONAL REQUIREMENTS.
5 COORDINATE WITH ALL TRADES AND SYSTEM INTEGRATORS ANY CONDITIONS RELATED TO THE INSTALLATION OF ALL SYSTEMS. THE CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE TRADE ALL INSTALLATION REQUIREMENTS IMPACTING THE PLACEMENT OF ALL SYSTEM COMPONENTS TO THE
SATISFACTION OF ALL CONCERNED TRADES.
6 COORDINATE EXACT LOCATION(S) OF ALL DATA AND TELEPHONE OUTLETS, ELECTRICAL RECEPTACLES WITH EXISTING FURNITURE AND ALL AFFECTED TRADES
PRIOR TO INSTALLATION.
7 ALL CONDUITS SHALL BE SIZED AND INSTALLED IN ACCORDANCE WITH NFPA 70 AND PROJECT SPECIFICATIONS. ALL CONDUITS SHALL BE A MINIMUM OF 3/4"
UNLESS OTHERWISE NOTED.
8 PROVIDE ALL EQUIPMENT CLEARANCES IN ACCORDANCE WITH NEC REQUIREMENTS. ARRANGE EQUIPMENT TO FACILITATE UNRESTRICTED ACCESS FOR MAINTENANCE AND SERVICE AROUND ALL EQUIPMENT, COMPONENTS AND/OR CABLE TERMINATIONS.
9 WHERE EQUIPMENT AND/OR JUNCTION BOXES ARE INSTALLED ABOVE FINISHED CEILINGS, THE CONTRACTOR SHALL PROVIDE ACCESS HATCHES LISTED FOR THE INTENDED APPLICATION. ACCESS HATCHES SHALL BE LOCATED SO THAT SERVICE ACCESS TO THE EQUIPMENT AND/OR JUNCTION BOXES IS UNIMPEDED.
10 ALL PENETRATIONS OF WALLS AND/OR FLOORS SHALL BE FIRE STOPPED IN ACCORDANCE WITH THE ASTM AND NFPA REQUIREMENTS. REFER TO RELATED SPECIFICATION SECTIONS FOR ADDITIONAL INFORMATION. INSTALLATION OF FIRE-STOPS SHALL BE PERFORMED BY APPLICATOR/INSTALLER QUALIFIED AND TRAINED BY THE MANUFACTURER. INSTALLATION SHALL BE PERFORMED IN STRICT ACCORDANCE WITH MANUFACTURER'S DETAILED INSTALLATION
PROCEDURES.
11 ALL EQUIPMENT ENCLOSURES LOCATED OUTSIDE OR IN ALL AREAS WITH HIGH MOISTURE OR A RELATIVE HUMIDITY OF 75% OR GREATER SHALL BE NEMA 4X
STAINLESS STEEL AND RATED FOR THAT APPLICATION.
12 ALL DEVICES, COMPONENTS OR EQUIPMENT INSTALLED ON THE EXTERIOR OF THE FACILITY SHALL BE PROVIDED IN ACCORDANCE WITH ALL MANUFACTURERS' REQUIREMENTS TO ENSURE THE PROPER OPERATION WHEN EXPOSED TO THE ENVIRONMENTAL CONDITIONS AND/OR AVERAGE ANNUAL LOWEST
TEMPERATURE THAT CAN BE ANTICIPATED FOR THE GEOGRAPHIC REGION OF THE FACILITY.
13 ALL INTERIOR AND/OR EXTERIOR COMPONENTS, DEVICES OR SYSTEMS EQUIPMENT EXPOSED TO THE GENERAL POPULATION SHALL BE INSTALLED IN SECURED EQUIPMENT ENCLOSURES WITH TAMPER SWITCHES AND INSTALLED IN SUCH A MANNER THAT RESISTS TAMPERING AND/OR REMOVAL WITHOUT THE USE OF
SPECIALIZED TOOLS.
14 FOR EQUIPMENT INSTALLATIONS REQUIRING COORDINATION WITH OTHER TRADES THE CONTRACTOR SHALL PROVIDE ALL TEMPLATES, BACKBOXES AND EQUIPMENT ANCHOR BOLTS FOR MOUNTING OR FLUSH MOUNTING PREPARATION, (E.G. PEDESTALS OR OTHER DEVICES REQUIRING MOUNTING ON WALLS, CONCRETE PADS OR OTHER MATERIALS). COORDINATE DELIVERY OF TEMPLATES AND EQUIPMENT WITH ALL AFFECTED CONTRACTORS.
15 ALL ELECTRICAL WORK SHALL BE DONE IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE (LATEST VERSION BEING ENFORCED), AND ALL OTHER APPLICABLE CODES AND STANDARDS BEING ENFORCED BY THE AUTHORITY HAVING JURISDICTION.
16 THESE DRAWINGS DO NOT INCLUDE NECESSARY COMPONENTS OR INSTRUCTIONS FOR CONSTRUCTION SAFETY. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR ANY WORKMAN'S OR TRANSIENT'S SAFETY, OR FOR THE ADEQUACY OF EQUIPMENT, BUILDING COMPONENTS, WORK AIDS, OR ANY NECESSITY TO WORK ON ENERGIZED ELECTRICAL COMPONENTS. FURTHER, NO SUPERINTENDENCE IS INCLUDED OR IMPLIED.
17 ALL SYSTEMS AND EQUIPMENT SHALL BE INSTALLED AND WIRED ACCORDING TO THE MANUFACTURER'S RECOMMENDATIONS.
18 ALL ELECTRICAL MATERIALS, DEVICES, APPLIANCES, AND EQUIPMENT SHALL BE TESTED AND LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY.
19 THE CONTRACTOR SHALL COORDINATE CONDUIT ROUTING (PLAN AND ELEVATION) WITH THE LIGHTING (NEW AND EXISTING), CEILING ELEVATION, STRUCTURE, DUCTWORK, PIPING, ETC. REQUIRED FOR THE COMPLETION OF THE PROJECT, PRIOR TO INSTALLATION.
20 THE DIMENSIONS SHOWN ON THE DRAWINGS ARE FOR THE CONVENIENCE OF THE CONTRACTOR ONLY. VERIFY ALL DIMENSIONS IN THE FIELD PRIOR TO
PERFORMING ANY WORK.
21 THE CONTRACTOR SHALL INSTALL ALL CONDUITS CONCEALED UNLESS NOTED OTHERWISE. EXPOSED CONDUIT SHALL ONLY BE INSTALLED IN CHASES, EXPOSED CEILING AREAS, JANITOR CLOSETS, AND MECHANICAL/ELECTRICAL ROOMS.
22 ALL ELECTRICAL EQUIPMENT SHALL BE GROUNDED AND/OR BONDED PER THE REQUIREMENTS OF THE NATIONAL ELECTRIC CODE. PROVIDE ALL GROUNDING
AND/OR BONDING COMPONENTS NOT EXPLICITLY SHOWN ON THE DOCUMENTS.
23 THE CONTRACTOR SHALL PROVIDE TYPEWRITTEN PANELBOARD DIRECTORIES, INDICATING THE LOADS SERVED BY THE RESPECTIVE PANELS. AMEND AS REQUIRED FOR AS-BUILT CONDITIONS. PROVIDE ELECTRONIC VERSIONS OF THE PANELBOARD SCHEDULES FOR FUTURE USE BY THE OWNER.
24 THE CONTRACTOR SHALL REVIEW THE WORK REQUIRED WITH THE APPLICABLE UTILITY COMPANIES SERVING THE PROJECT. ALL WORKPERFORMED SHALL BE
IN ACCORDANCE WITH THE REQUIREMENTS OF THE INDIVIDUAL UTILITY COMPANIES.
25 THE CONTRACTOR SHALL COORDINATE ALL WORK WITH THE OWNER PRIOR TO STARTING ALL PHASES OF THE PROJECT. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER WHAT WORK, IF ANY, HAS TO BE COMPLETED DURING SECOND OR THIRD SHIFT.
26 THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY POWER CONNECTIONS TO KEEP AREAS UP AND OPERATIONAL DURING THE CONSTRUCTION. THE
CONTRACTOR SHALL COORDINATE THESE REQUIREMENTS WITH THE OWNER.
27 THE VERBIAGE ON THE DRAWINGS INDICATING TYPES OF MATERIALS TO BE ENCOUNTERED IS INTENDED TO AID THE ELECTRICAL CONTRACTOR IN UNDERSTANDING THE VARIOUS CONDITIONS LIKELY TO BE ENCOUNTERED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING QUANTITIES OF
MATERIALS REQUIRED TO COMPLETE THE PROJECT.
28 THE LOCATIONS OF EXISTING UTILITIES, STRUCTURE AND OTHER CONDITIONS SHOWN ON THE PLANS ARE APPROXIMATE. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY AND REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO BEGINNING ANY WORK.
29 THE CONTRACTOR SHALL PROVIDE ALL NEW OPENINGS IN EXISTING PARTITIONS AND FLOORS FOR THE INSTALLATION OF ANY NEW ELECTRICAL WORK.
FURNISH AND INSTALL ALL REQUIRED SLEEVES FOR THIS NEW WORK. ALL CONDUITS SHALL HAVE SLEEVES INSTALLED. ALL THRU-WALL PENETRATIONS SHALL
BE TREATED AS 2-HOUR PENETRATIONS AND INSTALLED IN ACCORDANCE WITH UL-1479.
30 THE CONTRACTOR SHALL PROTECT ALL EXISTING MATERIALS THAT ARE TO REMAIN IN PLACE FROM DAMAGE. ANY DAMAGE TO EXISTING FINISHES, MATERIALS, ETC., SHALL BE REPLACED BY THE CONTRACTOR TO MATCH THE ADJACENT FINISH.
31 THE CONTRACTOR SHALL MAINTAIN THE BUILDING IN WEATHERTIGHT AND WATERPROOF CONDITION THROUGHOUT THE DURATION OF THEIR WORK. DO NOT LEAVE HOLES THROUGH WALLS AND/OR ROOFS OPEN TO THE ELEMENTS WHEN NO WORK IS OCCURRING IN THOSE AREAS.
32 THE CONTRACTOR SHALL PROVIDE ALL TRAFFIC CONTROL, FLAGMEN, SIGNAGE, ETC. WHEN DOING WORK THAT INTERFERES WITH PUBLIC RIGHT-OF-WAY.
33 THE CONTRACTOR SHALL CONTACT THE NATIONAL "811-CALL BEFORE YOU DIG" SYSTEM PRIOR TO PERFORMING ANY UNDERGROUND INSTALLATION WORK.
THE CONTRACTOR SHALL HAVE ALL UTILITIES VERIFIED IN AND AROUND THE EXCAVATION AREA.
34 THE CONTRACTOR SHALL GENERATE A DETAILED METHOD OF PROCEDURE (MOP) DOCUMENT INDICATING HOW HE/SHE INTENDS TO PERFORM EACH STEP IN THE PROJECT. THIS MOP SHALL BE PRESENTED TO THE OWNER AND ENGINEER PRIOR TO STARTING THE PROJECT, FOR SIGN OFF. THE MOP MAY BE REVISED BASED ON CHANGES IN THE PROJECT CONSTRUCTION, ETC. AT ALL POINTS IN THE PROJECT THE OWNER SHALL BE MADE AWARE OF CHANGES TO THE MOP, AND A REVISED MOP SHALL BE PRESENTED TO THE OWNER AND ENGINEER FOR SIGN OFF.
35 PROVIDE ALL JUNCTION BOXES, PULL BOXES AND OTHER PULL POINTS AS REQUIRED TO MEET THE MAXIMUM NUMBER OF BENDS PER NEC REQUIREMENTS.
NOT ALL CONDUITS, PULL BOXES AND OTHER RACEWAY ITEMS ARE INDICATED ON THE DOCUMENTS. THE CONTRACTOR SHALL PROVIDE A COMPLETE RACEWAY
SYSTEM MEETING THE REQUIREMENTS OUTLINED IN THE DRAWINGS AND SPECIFICATIONS.
36 THESE DRAWINGS DO NOT INDICATED ALL CONDUITS INTERCONNECTING EQUIPMENT, AND WHERE CONDUITS ARE INDICATED, THE ROUTING IS APPROXIMATE.
THE CONTRACTOR IS RESPONSIBLE FOR THE ROUTING AND INSTALLATION OF ALL CONDUIT IN COORDINATION WITH OTHER TRADES AND EXISTING CONDITIONS.
37 PROVIDE ALL JUNCTION BOXES AND OTHER PULL POINTSAS REQUIRED FOR EASE OF PULLING AND A CODE COMPLIANT INSTALLATION. ALL JUNCTION BOXES
AND OTHER PULL POINTS SHALL BE ACCESSABLE
38 MULTIWIRE BRANCH CIRCUITS ARE NOT PERMITTED, ALL SINGLE POLE BRANCH CIRCUITS SHALL HAVE A DEDICATED NEUTRAL.
39 MULTIPLE SMALL 20A/1P BRANCH CIRCUITS MAY SHARE A SINGLE CONDUIT PROVIDED THE CONTRATOR UPSIZES THE CONDUIT AS REQUIRED, AND THE
AMPACITY ADJUSTMENTS FROM TABLE 310.15(B) HAVE BEEN APPLIED.
DRAWING INDEX
SHEET # SHEET NAME
E001 ELECTRICAL SYMBOLS, ABBREVIATIONS, NOTES AND SHEET INDEX
01-E10B BUILDING 1 - BASEMENT PLAN
01-E101 BUILDING 1 - FIRST FLOOR PLAN
01-E102 BUILDING 1 - SECOND FLOOR PLAN
01-E103 BUILDING 1 - THIRD FLOOR PLAN
01-E104 BUILDING 1 - FOURTH FLOOR PLAN
01-E105 BUILDING 1 - FIFTH FLOOR PLAN
01-E106 BUILDING 1 - SIXTH FLOOR PLAN
01-E107 BUILDING 1 - SEVENTH FLOOR PLAN
02-E101 BUILDING 2 - FIRST FLOOR PLAN
03-E101 BUILDING 3 - FIRST FLOOR PLAN
07-E101 BUILDING 7 - FIRST FLOOR PLAN
22-E101 BUILDING 22 - FIRST FLOOR PLAN
32-E101 BUILDING 32 - FIRST FLOOR PLAN
D-E201 CBOC - DUBOIS FLOOR PLAN
H-E601 CBOC - HUNTINGDON FLOOR PLAN
I-E501 CBOC - INDIANA FLOOR PLAN
J-E301 CBOC - JOHNSTOWN FLOOR PLAN
SC-E401 CBOC - STATE COLLEGE FLOOR PLAN
E701 SYSTEM RISER DIAGRAM AND GENERAL DETAILS
SEAL
MECH
RM
22 22A
47B
26A
S00
E02
27A
29 29A 30
31 32
32B
32C
47A
28A
18B
18A
17A
16B
16A 17
15C
15A
E00
E00A
E00B
5B
5A
13A
S03
7A
1A
S02
42 41
41A
42A
42B
35 37
37A
48C
S01
A000A
A000 A000C
AS000
A000E
31A
S04
A000K A000J A000I A000H A000G
A000B
A000F
A000D
41C 41B
FD
SF
SF
SF
MECH RM ENG
SVC
ELEC SHOPENG
SVC
CHIEF
M&R
OFFICE
STOR
MACHINE SHOP
PLUMBING
SHOP
ENG
SVC
CARPENTER SHOP ENG
SVC
PLAN
RM
CORR
PAINT
SHOP
M TLT
EMS
STAIRS
ELEV
LOBBY
MAIL ROOM
MAS
STOR
MAS
STORAGE
MAS
BIO-MED
SHOP
STOR
A&MM
FHC
MC
CORR
FHC
MECH RM ENG
SVC
CORR
STORAGE ENG
SVC
LOCKER RM
EMS
SHR
RM
M TLT
EMS
STORAGE
VCS
STOR
REFIRIG
ELEV
ELEV
ELEV
KITCHEN
VCS
DINING RM
VCS
A/C SHOP ENG
SVC
CORR
TELE
EC
FHC
STORAGE
VCS
STAIRS
OFFICE CRED
UN
CRED
UN
OFFICE CRED
UN
LOCKER
RM
CLO
OFFICE
EMS
CH OFF
VCS
RETAIL
STORE
RETAIL
STOR
STAIRS
STOR
VCS
STOR
A&MM
STOR
A&MM
TEL
TEL
CL
SIGN
SH
STOR
A&MM
MECH
RM
UNEXCAVATED
EC
ELEC
CL
HAC
CORR
HAC
STOR
STAIRS
PHARMACY
CACHE
STOR
MECH
MECH
SHAFT
STAIRS
ELEC
UNEXCAVATED
EQ
STOR ELEVATOR
MECH
RM
MECH
PIT
POLICE TRAINING
ROOM
STAIRS
MECHANICAL
ROOM
OFFICE OFFICE OFFICE OFFICE OFFICE
SF
HVAC
SHOP
DATA
PANDEMIC
COMP.
RM
HSK
ROOM
BUILDING 1 -
BASEMENT
T V
T V
T V
A
E
E
N
E
SPBC -1/16
I
N
E
E
IT CLOSET
N
N
N
C
E
F
A
KEYED NOTES
EXISTING MONITOR ACCEPTS HDMI CONNECTION.
EXISTING MONITOR NEEDS TO BE REPLACED.
NEW MONITOR LOCATION. INSTALL EXISTING MONITOR SALVAGED FROM OTHER
AREAS IN THE HOSPITAL SCHEDULED TO BE RE-USED AS PART OF THIS PROJECT. IF
THE BALANCE OF EXISTING MONITOR SALVAGED IS LESS THAN THE NEW MONITORS
REQUIRED, PROVIDE NEW MONITORS AS SPECIFIED. INSTALLATIONS ON FIRE RATED
WALLS SHALL BE PROVIDED WITH THE PROPER UL LISTED ASSEMBLY TO
MAINTAINING THE FIRE RATING OF THE STRUCTURE.
RE-PURPOSE EXISTING DATA OUTLET. RELOCATE BEHIND MONITOR AS REQUIRED.
NO EXISTING DATA OUTLET. PROVIDE NEW FROM THE IT CLOSET IDENTIFIED AND
INSTALL BEHIND THE MONITOR.
NO EXISTING POWER OUTLET. PROVIDE NEW HOSPITAL GRADE DUPLEX RECEPTACLE
AND CONNECT TO THE NEAREST RECEPTACLE CIRCUIT WITH (2) #12, (1) #12G IN 3/4"
CONDUIT.
CAREFULLY REMOVE EXISTING ,MONITOR, MOUNTING STRUCTURE, POWER AND TV
OUTLETS. SALVAGE EXISTING MONITOR AND MOUNTING STRUCTURE FOR RE-USE AS
PART OF THIS PROJECT. PATCH AND PAINT WALL TO MATCH EXISTING.
REPLACE EXISTING SIMPLEX OUTLET WITH DUPLEX.
PROVIDE NEW MODULAR PATCH PANEL AND MOUNT ON EXISTING 2-POST RACK.
PROVIDE NEW UTP CABLING AND TERMINATE ON EXISTING PANDUIT DP6 PLUS OPEN
PORT.
B
C
D
E
F
G
H
I
J
ELECTRICAL SYMBOLS LEGEND
DUPLEX RECEPTACLE IN A 4" SQUARE BOX WITH PLASTER RING (IN DRYWALL)
SINGLE GANG BOX IN MASONRY.
DOUBLE DUPLEX RECEPTACLE IN A 4" SQUARE BOX
NEW FIRE RATED SLEEVE. ALL PENETRATIONS OF WALLS AND/OR FLOORS
SHALL BE FIRE STOPPED IN ACCORDANCE WITH THE ASTM AND NFPA
REQUIREMENTS FOR FIRE RATING. REFER TO RELATED SPECIFICATION
SECTIONS FOR ADDITIONAL INFORMATION. INSTALLATION OF FIRE-STOPS
SHALL BE PERFORMED BY APPLICATOR/INSTALLER QUALIFIED AND TRAINED BY
THE MANUFACTURER. INSTALLATION SHALL BE PERFORMED IN STRICT
ACCORDANCE WITH MANUFACTURER'S DETAILED INSTALLATION PROCEDURES.
WALL MOUNTED DATA OUTLET - PROVIDE DOUBLE GANG BACKBOX W/ SINGLE
GANG DEVICE RING, 1 1/4" EMT CONDUIT W/ PULLSTRING TO ABOVE
ACCESSIBLE CEILING.
SYSTEMS SYMBOLS LEGEND
NEW CATEGORY 6 UTP CABLE - PLENUM RATED
TV TELEVISION/MONITOR WITH HDMI CONNECTION
LIFE SAFETY LEGEND
BUILDING SEPARATION
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
1/2 HOUR FIRE BARRIER
SMOKE BARRIER
SMOKE RESISTIVE CONSTRUCTION
CONSULTANTS:
Drawing Title
Approved:
Project Title:
Location:
Date: Checked: Drawn:
Drawing Number
Dwg. of
Building Number
Project Number
Office of Construction and Facilities Management
VA FORM 08-6231
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
A
B
C
D
E
F
6 " o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t
209 SANDUSKY STREET
PITTSBURGH, PA 15212
PH: 412.287.7333
www.ae-works.com
AE WORKS PROJECT NUMBER:
ARCHITECTS/ENGINEERS:SEAL
Revision# Date
5/ 4/
:1
9:
P M
JEVZ MEDICAL CENTER -
ELECTRONIC SIGNAGE
503-17-103
BK SH
2907 Pleasant Valley Blvd, Altoona, PA 16602
01-E10B
BUILDING 1 - BASEMENT PLAN
05/07/2018 202 17033
BID DOCUMENTS
100% SUBMISSION
NOT TO SCALE
BUILDING 1 - BASEMENT FLOOR PLAN
DN
141C
141Q
141L
141B
141D
141N141E 141M 131B 131C
131D
131E
131F
141G
141A
E102 144A 145
145A 145B
S100
140C
140B
140A
134A
131A
130B
130A
131K
131J
131H
131G
129B
129A 129
125A
147C
148B
148C
148A
148A
E100
126A
118 119 194C
120A
118A
117A
116B
117B
199A
S102
198C
116A
116C
116D
115A
100C
100D
100A
100B
101A 101B
101D
S103
102A
102B
113B 113A 103
198D
197A 197
194B
151A
152A 157D 156A4
195B
157A
157J
194A
193G
193F
S101
193E
193D 193C
192G
188B
187186
185184183
188A
180A
157B
E101
176H
172G
172E
172D
172F
172I
172J
172C
172B
172A
S104
162A
160160A159159A 159B159C
158A
168A
161A
167 166
168B
157E
169C
169B
169A
161B
173174
175A
157C 177A
A117A
A117
A120 A119 A118
A123
A121
A125
A122A
A122B
A124 A126
A127 A129
A130 A131
A128
A132 A133
A135 A134
AS100
A114
A122
A136 A137
A116 A115
A112
A140A
A140
A139 A138E A138D A138C A138B
A141
A142
A138A
A138
A143A138F
A109A111
A110
A148 A147
A146 A138G
A145
A144
A105
A106
A107A A107
A106F A106A
A106BA106C
A106E A106D
A104
A102 A101B
A101A
A101 A101C
A101D
A100
A101E
156A1
156B 156
B102
B122A
B124
B123
B122
B120
B121
B10
B105 B103
B11 B11
B117
B113
B10
B107
B10
B10
B110
B111
B112
B11 B115 B114 C123
C124
C122 C121 C120 C11 C11 C117
C115
C13 C13
C137
C11
C114
C113
C135
C13
C125
C12 C12
C127
C110
C111
C112
C131
C134
C107
C132
C133
C103 C101
C102
C10
C10
C10
C105
C130
C104
C12
STOR.
LAUNDRY
VETERANCE
BEN.
VETERANCE
BEN.
FIRE
CLOS.
LAUNDRY
STORAGE VEST
CAT
SCAN
OFFICE
COMPUTER
RM
XRAY FILE
STOR
LAUNDRY
CORR
PATIENT
CLOTHING
STORAGE
ELEC
CLOS ELEV
SOCIALWOMENS EMPLOYEE
LOUNGE
CLINIC
OFFICE
STAIRS OFFICE
LITTER
AREA
MORGUE
AUTOPSY
TLT
TLT
XRAY
CAT
SCAN
STOR
CL
CL
CL
STORAGE
ULTRTA
SOUND
OFFICE
XRAY FILE
STOR
SOILED
UTIL
VIEWING
RADIOLOGY
DEXA OFFICE
XRAY XRAY
WAITING
WAITING
FXC
TLT
XRAY
CADIO LAB
EKG
LAB
OFF
LAB
OFFICE
ECHO
LAB
AUDIOLOGY
CLINIC
OFFICE
WAITING
ELEV
W
TLT
TLT
MENS
OFFICE
OFFICE
OFFICE
DIET CONSULT LOBBY
OP MANGER
OFF
RESPIRATORY
RESP.
EXAM/TREAT
RESP.
TOILET
CASHIER
TEL
CL
STAIRS
ELEC
RM
BILLING
OFF
EXAM/TREAT
CORR
EXAM/TREAT
EXAM/TREAT
WAITING
TOILET
TOILET
CLERK/HBA
CORR.
CLERK/HBA
CLERK/HBA
EQUIPMENT
RM
CORR.
NURSE
STA.
STOR.
STAIRS DIRTY
UT.
ENT./CONF.
CORR.
NURSING
CONSULT. SURG.
NURSE
EXAM
AUDIOLOGY
ELECTRIC
AUDIOLOGY
OFFICE
OFFICE
OFFICE PRIMARY
CARE
M
TLT
W
TLT
PR
CAREMED
DIR
CORR
CLERK
OFF
CHIEF
CLERK
OFF
CLERK
OFF
CLERK
OFF
CLERK
OFF
MULTI-PURPOSE
SECRETARY
PR. CARE
OFF
MED
PREP
VEST
MED
RECORDS
OFFICE
STAIRS
MED
RECORDS
EQUIP
CLERK CLERK
VEST
POLICEDIR.SECURITY
M.
TLT
W.
TLT
MECH
RM
MECH
RM
OUTPATIENT
LOBBY
ELEV
CHECK-IN
CLERK
CLERK
CLERK
CLERK
EXAM
RM
EXAM
RM
EXAM
RM
EXAM
RM
EXAM
RM
EXAM
RM
STAIRS
WAITING
ROOM
HAC
MECH
RM
ELEC.
CL.
DIR.OPSERV.
OFFICE EXAM
RM
CORR
B.P.SCR
RM TLT ELEC
CL
TEL
CL
TLT
EXAM
RM
TLT
VAULT
PHARMACY
EXAM
RM
EXAM
RM
EXAM
RM
CORR
EXAM
RM
EXAM
RMTLT
HAC
STOR.
OFFICE
CONF
RM
PHARMACY
OFF
MECH
SHAFT
MECH
SHAFT
WAITING
CORR
PAT
TLT
STAFF
TLT CONF/MTG
STAFF
RM.
CLERKS
MEDS
DISCHARGE
DISCHARGE
CLEAN
UTIL. SOILED
EX/TRT/OFF
EXAM
RM
EX
RM EX/TRT/OFF
CORR
EX
RM EX/TRT/OFF
EX/TRT/OFF EX/TRT/OFF
STAIRS
CORR
CORR
EX
RM
EX/TRT/OFF
EX/TRT/OFF
EX/TRT/OFF
EXAM
ELEC.CL.
HAC
PAT
TLT
BED
BED
BED
BED
DECONTAMINATION
VESTIBULE
EQUIP.
ALCOVE
CORR
CORR
NURSES
STATION
CORR
EXAM
RM
OXYGEN
ALCOVE
CLEAN
HOLD
MED
RM. NOUR
CLERKA
TRIAGE
REGISTRATION
CENTRAL
REGISTRATION
TLT/SHR
ON-CALL
ELIGIBILITY MACHINES
OPERATOR
STAFF
TLT
V.I.C
OFFICE
LOCKERS
CORR
CORR WAITING
WHEEL CHAIR
STOR.
WAITING
RECEP
AOD
VESTIBULE
ER
WAITING
CLINIC
CLOSET
RM
EXAM
RM
PRACTITIONER
NURSE
PRACTITIONER
EXAM
RM
INTERVIEW
H O U S E
K E E P
IN
G
TOIL
ROOMSCAN
CONTROL
RM
FREEZER
FREEZER
OXYGEN SMOKING
RM
OFFICE
LOCKER
ECHO
CAROTID
DOPLER
SUPERVISOR
CONSULT #
CONSULT #
RX
PICKUP
STORAGE
WORK
WAITING
CLEAN
JANITOR
ELECTRICAL
IT
BREAK
ROOM
ADL
OT
GYM
CORRIDOR
CLERK
UNI-SEX
OT
OFFICE
PT
OFFICE
HYDRO
THERAPY
PT GYM
STORAGE
TOILET
OT
EX/TRT/OFF
OT
EX/TRT/OFF
OT
EX/TRT/OFF
STAFF
TOILET
UNI-SEX
TOILET
SOILED
LAUNDRY
PT
EX/TRT/OFF VESTIBULE
PT
EX/TRT/OFF
PT
EX/TRT/OFF
CORRIDOR
PROST.
OFF.
CORRIDOR
PROSTHETICS STAFF
STAFF
BREAK
SUPERVISOR
PROSTHETICS
SPEECH
SOILED
MED SUPP
PRINT ROOM TOILET
PROST.
OFF.
PROST.
OFF.
PROST.
OFF.
PROST.
OFF.
PROST.
OFF.
ROOM
PROSTHETICS
OFFICE
FILING
ROOM
PATHOLOGIST
UTL.
ROOM
ROOM
STORAGE
CONFERENCE
ROOM
POWER
MOBILITY/AMPUTEE
CLINIC
CORRIDOR
CLEAN
SUPPLY/O2
STORAGE
CLINICAL
OFFICE
CLINICAL
OFFICE
EXAM
TREATMENT
ROOM
EMG/EXAM
ROOM
CORRIDOR
EXAM
TREATMENT
ROOM
EXAM
TREATMENT
ROOM
WAITING
ROOM VESTIBULE
LOBBY
SECRETARY/CLERK
ADMIN
OFFICER
PMRS
CHIEF
OFFICE
UNI-SEX
TOILET
JANITOR
ELECTRICAL
CLOSET
STAFF
TOILET
FUTURE MENTAL HYGIENE & CLINIC SPACE
40' X 72'
U P
T V
TV
TV T
V
TV
TV
TV
T
V TV
T V
A
D
A
H
E
E
A
E
A
A
E
D
N
E E
LWBC-31
IT CLOSET
E
E
EQP1-38E
E
E
E
E EQP2-6
E A E
E
N
I
J
I
N
N N
N
IT CLOSET
E
IT CLOSET E
EQP1-38
EE
E
EN
N E
E
LSP1B-5
LSP1B-5
A E
A E
G
G
N
N
N
C
E
F
A
KEYED NOTES
EXISTING MONITOR ACCEPTS HDMI CONNECTION.
EXISTING MONITOR NEEDS TO BE REPLACED.
NEW MONITOR LOCATION. INSTALL EXISTING MONITOR SALVAGED FROM OTHER
AREAS IN THE HOSPITAL SCHEDULED TO BE RE-USED AS PART OF THIS PROJECT. IF
THE BALANCE OF EXISTING MONITOR SALVAGED IS LESS THAN THE NEW MONITORS
REQUIRED, PROVIDE NEW MONITORS AS SPECIFIED. INSTALLATIONS ON FIRE RATED
WALLS SHALL BE PROVIDED WITH THE PROPER UL LISTED ASSEMBLY TO
MAINTAINING THE FIRE RATING OF THE STRUCTURE.
RE-PURPOSE EXISTING DATA OUTLET. RELOCATE BEHIND MONITOR AS REQUIRED.
NO EXISTING DATA OUTLET. PROVIDE NEW FROM THE IT CLOSET IDENTIFIED AND
INSTALL BEHIND THE MONITOR.
NO EXISTING POWER OUTLET. PROVIDE NEW HOSPITAL GRADE DUPLEX RECEPTACLE
AND CONNECT TO THE NEAREST RECEPTACLE CIRCUIT WITH (2) #12, (1) #12G IN 3/4"
CONDUIT.
CAREFULLY REMOVE EXISTING ,MONITOR, MOUNTING STRUCTURE, POWER AND TV
OUTLETS. SALVAGE EXISTING MONITOR AND MOUNTING STRUCTURE FOR RE-USE AS
PART OF THIS PROJECT. PATCH AND PAINT WALL TO MATCH EXISTING.
REPLACE EXISTING SIMPLEX OUTLET WITH DUPLEX.
PROVIDE NEW MODULAR PATCH PANEL AND MOUNT ON EXISTING 2-POST RACK.
PROVIDE NEW UTP CABLING AND TERMINATE ON EXISTING PANDUIT DP6 PLUS OPEN
PORT.
B
C
D
E
F
G
H
I
J
ELECTRICAL SYMBOLS LEGEND
DUPLEX RECEPTACLE IN A 4" SQUARE BOX WITH PLASTER RING (IN DRYWALL)
SINGLE GANG BOX IN MASONRY.
DOUBLE DUPLEX RECEPTACLE IN A 4" SQUARE BOX
NEW FIRE RATED SLEEVE. ALL PENETRATIONS OF WALLS AND/OR FLOORS
SHALL BE FIRE STOPPED IN ACCORDANCE WITH THE ASTM AND NFPA
REQUIREMENTS FOR FIRE RATING. REFER TO RELATED SPECIFICATION
SECTIONS FOR ADDITIONAL INFORMATION. INSTALLATION OF FIRE-STOPS
SHALL BE PERFORMED BY APPLICATOR/INSTALLER QUALIFIED AND TRAINED BY
THE MANUFACTURER. INSTALLATION SHALL BE PERFORMED IN STRICT
ACCORDANCE WITH MANUFACTURER'S DETAILED INSTALLATION PROCEDURES.
WALL MOUNTED DATA OUTLET - PROVIDE DOUBLE GANG BACKBOX W/ SINGLE
GANG DEVICE RING, 1 1/4" EMT CONDUIT W/ PULLSTRING TO ABOVE
ACCESSIBLE CEILING.
SYSTEMS SYMBOLS LEGEND
NEW CATEGORY 6 UTP CABLE - PLENUM RATED
TV TELEVISION/MONITOR WITH HDMI CONNECTION
LIFE SAFETY LEGEND
BUILDING SEPARATION
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
1/2 HOUR FIRE BARRIER
SMOKE BARRIER
SMOKE RESISTIVE CONSTRUCTION
CONSULTANTS:
Drawing Title
Approved:
Project Title:
Location:
Date: Checked: Drawn:
Drawing Number
Dwg. of
Building Number
Project Number
Office of Construction and Facilities Management
VA FORM 08-6231
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
A
B
C
D
E
F
6 " o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t
209 SANDUSKY STREET
PITTSBURGH, PA 15212
PH: 412.287.7333
www.ae-works.com
AE WORKS PROJECT NUMBER:
ARCHITECTS/ENGINEERS:SEAL
Revision# Date
5/ 4/
:1
9:
P M
JEVZ MEDICAL CENTER -
ELECTRONIC SIGNAGE
503-17-103
BK SH
2907 Pleasant Valley Blvd, Altoona, PA 16602
01-E101
BUILDING 1 - FIRST FLOOR PLAN
05/07/2018 203 17033
BID DOCUMENTS
100% SUBMISSION
NOT TO SCALE
BUILDING 1 - FIRST FLOOR PLAN
UP
UP
UP
UP
232A
232C
236A
234B
234A
229A
S201
236E202
240C
240B
274B
240A
216A
205A
S203
203A
240D
274A
S202
E200
271272 273 268
241A
243A 243B 244A
251251A
252A
253A 253B 253C 257
253D
253E 253F
253G
256B
A
255A
S204
254B
254A
253V 253U
253L253M
253K
T
253S
253R
N253Q
253P
253J
253H
E201
S201
265266
259A
258A
258B
261A
261C
261B
262A
262B 262C
274C
274D
274E
274F
275A
275B
275C
274G
274H276
273A
A
STOR
STOR
CORR
STOR FOOD
FREEZER
FREEZER
CORR
CLEANING
SUPPLIES
STOR
STOR
TRASH
RM
STORE
FREEZER
TLT
INGREDIENT
STORAGE
BREAK
ROOM
STAIRS
POT/PAN WASH
RM
FREEZER
SOILEDELEV
KITCHEN
DISH
ROOM
DIETICIAN
OFFICE
CHIEF
NUTRITION
CORR
OFFICE
DIET
COMM
VOLUNTEER
STOR
DAYROOM
CHIEF VOL
SERV
SECRY VOL
SERV
CATHOLIC
SOC WK
OFFICE
OFFICE
OFFICE
SACRISTY
CHAPLIN
OFFICE
HAC
STAIRS
PROSTHET
OFFICE
STOR
CHAPEL
FXC
ELEC
CLO
EDUCATION
CLASSROOM
LOUNGE
CHAPLIN
CORR
STAIRS
ELEV
VOL.
KIT
HAC
ELEC.
CL
TELE
CL
OFFICE
RECEPTIONIST
WAITING
ROOM DARK
RM
XRAY XRAY STOR
STOR
EXAM
ROOM
STOR
STERILIZER
RM
EXAM/TR
D E N T A L C A S T
R M
EXAM/TREXAM/TR
ORAL
SURG
STORAGE
CHEMISTRY
LAB
SECRETARY
SECRY SPEECH
PATH
WAITING
ROOM
TLT
TLT
LIBRARY
LIBR.
OFFICE
L
IB
R W O R K
R M
ELEC
CLO
TEL
STAIRS
LAB CONF
RM
TLT
TLT
HISTOLOGY
MICROBOLOGY
SUPPLY
STORHAC
STORAGE
L A B
O F F
IC
E
MICROBIOLOGY
STOR
S P E C
IA
L
C H E M
IS
T R
YEQUIP
RM
WASH
RM
BLOOD BANK
PHLOBOTOMY
ELEV
PHYSICAL
THERAPY
TUB
ROOM
OCCUPATIONAL
THERAPY
STAIRS
STORWOMENS
MENS
PHYS TH
OFFICE
OFFICE
OFFICE
STOR
STORAGE
TLT
STOR
PT
OFFICE
LOBBY
VEST
CORR
CORR
CORR
CORR
CORR
CORR
CORR
CORR
CORRCORR
TEL
ROOF OF FIRST
FLOOR
WAREHOUSE
OFFICE
HISTOLOGY
MICROBIOLOGY
OFFICE
S T O R A G E x x x x x x x x x xxxxxxx x x x x x x x x x x x x x x x x x x x x x x x x x x x
BUILDING 1 - FLOOR
TV
TV
T V
T V
A
A
E
E
E E N
LP2D-22
LP2A2-3
E
E N
I
IT CLOSET
N
N
N
C
E
F
N
N
N
C
E
F
K
A
KEYED NOTES
EXISTING MONITOR ACCEPTS HDMI CONNECTION.
EXISTING MONITOR NEEDS TO BE REPLACED.
NEW MONITOR LOCATION. INSTALL EXISTING MONITOR SALVAGED FROM OTHER
AREAS IN THE HOSPITAL SCHEDULED TO BE RE-USED AS PART OF THIS PROJECT. IF
THE BALANCE OF EXISTING MONITOR SALVAGED IS LESS THAN THE NEW MONITORS
REQUIRED, PROVIDE NEW MONITORS AS SPECIFIED. INSTALLATIONS ON FIRE RATED
WALLS SHALL BE PROVIDED WITH THE PROPER UL LISTED ASSEMBLY TO
MAINTAINING THE FIRE RATING OF THE STRUCTURE.
RE-PURPOSE EXISTING DATA OUTLET. RELOCATE BEHIND MONITOR AS REQUIRED.
NO EXISTING DATA OUTLET. PROVIDE NEW FROM THE IT CLOSET IDENTIFIED AND
INSTALL BEHIND THE MONITOR.
NO EXISTING POWER OUTLET. PROVIDE NEW HOSPITAL GRADE DUPLEX RECEPTACLE
AND CONNECT TO THE NEAREST RECEPTACLE CIRCUIT WITH (2) #12, (1) #12G IN 3/4"
CONDUIT.
CAREFULLY REMOVE EXISTING ,MONITOR, MOUNTING STRUCTURE, POWER AND TV
OUTLETS. SALVAGE EXISTING MONITOR AND MOUNTING STRUCTURE FOR RE-USE AS
PART OF THIS PROJECT. PATCH AND PAINT WALL TO MATCH EXISTING.
REPLACE EXISTING SIMPLEX OUTLET WITH DUPLEX.
PROVIDE NEW MODULAR PATCH PANEL AND MOUNT ON EXISTING 2-POST RACK.
PROVIDE NEW UTP CABLING AND TERMINATE ON EXISTING PANDUIT DP6 PLUS OPEN
PORT.
B
C
D
E
F
G
H
I
J
ELECTRICAL SYMBOLS LEGEND
DUPLEX RECEPTACLE IN A 4" SQUARE BOX WITH PLASTER RING (IN DRYWALL)
SINGLE GANG BOX IN MASONRY.
DOUBLE DUPLEX RECEPTACLE IN A 4" SQUARE BOX
NEW FIRE RATED SLEEVE. ALL PENETRATIONS OF WALLS AND/OR FLOORS
SHALL BE FIRE STOPPED IN ACCORDANCE WITH THE ASTM AND NFPA
REQUIREMENTS FOR FIRE RATING. REFER TO RELATED SPECIFICATION
SECTIONS FOR ADDITIONAL INFORMATION. INSTALLATION OF FIRE-STOPS
SHALL BE PERFORMED BY APPLICATOR/INSTALLER QUALIFIED AND TRAINED BY
THE MANUFACTURER. INSTALLATION SHALL BE PERFORMED IN STRICT
ACCORDANCE WITH MANUFACTURER'S DETAILED INSTALLATION PROCEDURES.
WALL MOUNTED DATA OUTLET - PROVIDE DOUBLE GANG BACKBOX W/ SINGLE
GANG DEVICE RING, 1 1/4" EMT CONDUIT W/ PULLSTRING TO ABOVE
ACCESSIBLE CEILING.
SYSTEMS SYMBOLS LEGEND
NEW CATEGORY 6 UTP CABLE - PLENUM RATED
TV TELEVISION/MONITOR WITH HDMI CONNECTION
LIFE SAFETY LEGEND
BUILDING SEPARATION
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
1/2 HOUR FIRE BARRIER
SMOKE BARRIER
SMOKE RESISTIVE CONSTRUCTION
CONSULTANTS:
Drawing Title
Approved:
Project Title:
Location:
Date: Checked: Drawn:
Drawing Number
Dwg. of
Building Number
Project Number
Office of Construction and Facilities Management
VA FORM 08-6231
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
A
B
C
D
E
F
6 " o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t
209 SANDUSKY STREET
PITTSBURGH, PA 15212
PH: 412.287.7333
www.ae-works.com
AE WORKS PROJECT NUMBER:
ARCHITECTS/ENGINEERS:SEAL
Revision# Date
5/ 4/
:1
9:
P M
JEVZ MEDICAL CENTER -
ELECTRONIC SIGNAGE
503-17-103
BK SH
2907 Pleasant Valley Blvd, Altoona, PA 16602
01-E102
BUILDING 1 - SECOND FLOOR PLAN
05/07/2018 204 17033
BID DOCUMENTS
100% SUBMISSION
NOT TO SCALE
BUILDING 1 - SECOND FLOOR PLAN
Fountain
Fountain
S304
S301
E301
364365
370B
366B
356B
357B
359358
357J
359H
357-3 357-2 357-1
357D
357A
356-5
356-4
356-3
356-2
352-1
356-6
368A
366C
350A
352A
366D
245C 345B
345A
308A
309A
377C
369A 369B
370A
377A
376C
376B
375B
375C
376A375A
366E
377B
381A
382B
342B 342A
342C
319321
325326
S300
S302
E300
313A
314A
315A
A
302A
305A
306B
S303
307A
305C
306A
303A
302B
302A
319A321A
331 333 334
325B
329A
333A
334A
386A
386B
386C
386D
386E
386F
386G
357C
366A
332A
383A
342D
335A
335B
300A
305B
306A
302B
306C
STAIRS
STAIRS
ELEV
ANESHESIA
WORKROOM
TEL
ELEC
ENGSTOR
STOR
SCRUB
RM
OPER RM
OR
OPER RM
OR
XRAY
OR
CYSTOSCOPY
STOR
ICU
HAC
TLT
ICU
C L
LI
N
IC
U
MEDICATION
ROOM
UTILITY
ROOM
NURSE
STA
NURSE STA
OR
LOCKER
HACSTORAGE
ISOLATION
ROOM
ISOLATION
RECOVERY
OR
RECOVERY
OR
RECOVERY
OR
TLT
PATIENT
RECEIVING
SLD UT
OR
1-BED RM
ICU
1-BED RM
ICU
1-BED RM
ICU
1-BED RM
ICU
1-BED RM
ICU
1-BED RM
ICU
MEDICAL
SVC
STER RM
OR
SCRUB
RM
SHOWER
ISOLATION
NRS
SUPR
CONSUT
RM
STORAGE
VISITORS
LAUNGE
TLT STAFF
LOUNGE
SCRUB
RM
RM
ICU RM
ICU
TLT
ICU
TLT
TLT
STORAGE
SPD
STOR
OR OR
STER. RM.
OR
STORAGE
SPD
SH
LOUNGE
OFFICE
SH
M
TLT
F
TLT
HEAD NRS
OF
PAT RCVG
OR
S L D
U T
O R
CONF RM
OR
STORAGE
SPD
STERILIZATION RM
SPD
WAREHOUSE
SPD
STER RM
SPDHAC
DECONT AREA
SPD
STOR
W. DRESS
TLT
M.
DRESS
CHIEF
SPD
SEC SURG
SVC
OFFICE
SURG CHIEF SURG
SVC
CHIEF MED
SVC
HOPETEL
HOPETEL
HAC
WAITING
ROOM
NURSING
NURSING
WAITING
ROOM
MED
REC
NRS
STA
NURSINGEXAM
RMSURGERY
EYE
GUHAC
STAIRS
MECHANICAL
ROOM
STOR
TLT
ELEC
CLO
TEL
CLO
STAIRS
ELEV
TLT
TLT NRS
SVC
NURSES
STATION
DAY
ROOM
CO
ORDINATOR
PODIATRY
UTILITY
RM
NURSING
GU
SURGERY
STAIRS
DR
RM
BATH/SH
DR
RM
DRESS
RM
TLT
DRESS
RM
SD
LINEN
TLTTLT
WAITING
ROOM
NEURO
EXAM
NEURO
NURSING
EXAM
RM
EXAM
RM
FXC
CLOSET
EYE
TECH
NURSING
TLT
NURSING
CORR
LOBBY
CORR
CORR
CORR
CORR
CORR
CORR
IV
STOR
HAC
ELEV.
EQUIP
TLT
TEL
CLO
OFFICE
CLERICAL
STAFF
GU
SURGICAL
ROOM
ROOM
CHECK
OUT
SPECIALITY
SERVICE
PODIATRY
MED.RM
SVC
RM
SPD
RM
SPD
F.
DRESS
M. DRESS
DRK RM
FEMALE SECRETARY
BUILDING 1 - FLOOR
TV
TV
T V
T V
A
E
E
A
N E E
E N E
J
IT CLOSET
N
N
N
C
E
F
N
N
N C
E
F
A
KEYED NOTES
EXISTING MONITOR ACCEPTS HDMI CONNECTION.
EXISTING MONITOR NEEDS TO BE REPLACED.
NEW MONITOR LOCATION. INSTALL EXISTING MONITOR SALVAGED FROM OTHER
AREAS IN THE HOSPITAL SCHEDULED TO BE RE-USED AS PART OF THIS PROJECT. IF
THE BALANCE OF EXISTING MONITOR SALVAGED IS LESS THAN THE NEW MONITORS
REQUIRED, PROVIDE NEW MONITORS AS SPECIFIED. INSTALLATIONS ON FIRE RATED
WALLS SHALL BE PROVIDED WITH THE PROPER UL LISTED ASSEMBLY TO
MAINTAINING THE FIRE RATING OF THE STRUCTURE.
RE-PURPOSE EXISTING DATA OUTLET. RELOCATE BEHIND MONITOR AS REQUIRED.
NO EXISTING DATA OUTLET. PROVIDE NEW FROM THE IT CLOSET IDENTIFIED AND
INSTALL BEHIND THE MONITOR.
NO EXISTING POWER OUTLET. PROVIDE NEW HOSPITAL GRADE DUPLEX RECEPTACLE
AND CONNECT TO THE NEAREST RECEPTACLE CIRCUIT WITH (2) #12, (1) #12G IN 3/4"
CONDUIT.
CAREFULLY REMOVE EXISTING ,MONITOR, MOUNTING STRUCTURE, POWER AND TV
OUTLETS. SALVAGE EXISTING MONITOR AND MOUNTING STRUCTURE FOR RE-USE AS
PART OF THIS PROJECT. PATCH AND PAINT WALL TO MATCH EXISTING.
REPLACE EXISTING SIMPLEX OUTLET WITH DUPLEX.
PROVIDE NEW MODULAR PATCH PANEL AND MOUNT ON EXISTING 2-POST RACK.
PROVIDE NEW UTP CABLING AND TERMINATE ON EXISTING PANDUIT DP6 PLUS OPEN
PORT.
B
C
D
E
F
G
H
I
J
ELECTRICAL SYMBOLS LEGEND
DUPLEX RECEPTACLE IN A 4" SQUARE BOX WITH PLASTER RING (IN DRYWALL)
SINGLE GANG BOX IN MASONRY.
DOUBLE DUPLEX RECEPTACLE IN A 4" SQUARE BOX
NEW FIRE RATED SLEEVE. ALL PENETRATIONS OF WALLS AND/OR FLOORS
SHALL BE FIRE STOPPED IN ACCORDANCE WITH THE ASTM AND NFPA
REQUIREMENTS FOR FIRE RATING. REFER TO RELATED SPECIFICATION
SECTIONS FOR ADDITIONAL INFORMATION. INSTALLATION OF FIRE-STOPS
SHALL BE PERFORMED BY APPLICATOR/INSTALLER QUALIFIED AND TRAINED BY
THE MANUFACTURER. INSTALLATION SHALL BE PERFORMED IN STRICT
ACCORDANCE WITH MANUFACTURER'S DETAILED INSTALLATION PROCEDURES.
WALL MOUNTED DATA OUTLET - PROVIDE DOUBLE GANG BACKBOX W/ SINGLE
GANG DEVICE RING, 1 1/4" EMT CONDUIT W/ PULLSTRING TO ABOVE
ACCESSIBLE CEILING.
SYSTEMS SYMBOLS LEGEND
NEW CATEGORY 6 UTP CABLE - PLENUM RATED
TV TELEVISION/MONITOR WITH HDMI CONNECTION
LIFE SAFETY LEGEND
BUILDING SEPARATION
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
1/2 HOUR FIRE BARRIER
SMOKE BARRIER
SMOKE RESISTIVE CONSTRUCTION
CONSULTANTS:
Drawing Title
Approved:
Project Title:
Location:
Date: Checked: Drawn:
Drawing Number
Dwg. of
Building Number
Project Number
Office of Construction and Facilities Management
VA FORM 08-6231
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
A
B
C
D
E
F
6 " o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t
209 SANDUSKY STREET
PITTSBURGH, PA 15212
PH: 412.287.7333
www.ae-works.com
AE WORKS PROJECT NUMBER:
ARCHITECTS/ENGINEERS:SEAL
Revision# Date
5/ 4/
:1
9:
P M
JEVZ MEDICAL CENTER -
ELECTRONIC SIGNAGE
503-17-103
BK SH
2907 Pleasant Valley Blvd, Altoona, PA 16602
01-E103
BUILDING 1 - THIRD FLOOR PLAN
05/07/2018 205 17033
BID DOCUMENTS
100% SUBMISSION
NOT TO SCALE
BUILDING 1 - THIRD FLOOR PLAN
S400
429 430 431 432
415A
427 428
S404
434I
S401
434J
443444 445447
S402
444A
400401
E400
405406
412A
413A
444A 444B
444C414
418417
442442ASTAIRS
4-BED RM NRS
SVC
4-BED RM NRS
SVC
TLTTLT
1-BED RM NRS
SVC
NRS.
STATION
STAIRS
PENTHOUSE MECH RM ENGR
SERVICE
THERAPY
RECREATION
SLD
UT
STAIRS
HAC
LOUNGE
CONF
RM
CL
LINEN
MED
PREP
STOR
STAIRS
TEL.
CL
CORR
OFFICEOFFICE
OFFICE
TLT
ELEV
STOR
STOR
NOUR
KIT
LINEN
ROOM
BREAK
ROOM
UTL.
ROOM
STO
ELEC
ROOM
TLT
1-BED RM NRS
SVC
ISOLA
ISOLA
CORR CORR
SECR
CORRFXC
FXC
CART
TEL.
CL
STOR
NRS.
STATION
CRASH
OXY
T
V
T V
A
E
N
N
N
C
E
F
IT CLOSET
J
E
N
E
ELECTRICAL SYMBOLS LEGEND
DUPLEX RECEPTACLE IN A 4" SQUARE BOX WITH PLASTER RING (IN DRYWALL)
SINGLE GANG BOX IN MASONRY.
DOUBLE DUPLEX RECEPTACLE IN A 4" SQUARE BOX
NEW FIRE RATED SLEEVE. ALL PENETRATIONS OF WALLS AND/OR FLOORS
SHALL BE FIRE STOPPED IN ACCORDANCE WITH THE ASTM AND NFPA
REQUIREMENTS FOR FIRE RATING. REFER TO RELATED SPECIFICATION
SECTIONS FOR ADDITIONAL INFORMATION. INSTALLATION OF FIRE-STOPS
SHALL BE PERFORMED BY APPLICATOR/INSTALLER QUALIFIED AND TRAINED BY
THE MANUFACTURER. INSTALLATION SHALL BE PERFORMED IN STRICT
ACCORDANCE WITH MANUFACTURER'S DETAILED INSTALLATION PROCEDURES.
WALL MOUNTED DATA OUTLET - PROVIDE DOUBLE GANG BACKBOX W/ SINGLE
GANG DEVICE RING, 1 1/4" EMT CONDUIT W/ PULLSTRING TO ABOVE
ACCESSIBLE CEILING.
SYSTEMS SYMBOLS LEGEND
NEW CATEGORY 6 UTP CABLE - PLENUM RATED
TV TELEVISION/MONITOR WITH HDMI CONNECTION
LIFE SAFETY LEGEND
BUILDING SEPARATION
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
1/2 HOUR FIRE BARRIER
SMOKE BARRIER
SMOKE RESISTIVE CONSTRUCTION
A
KEYED NOTES
EXISTING MONITOR ACCEPTS HDMI CONNECTION.
EXISTING MONITOR NEEDS TO BE REPLACED.
NEW MONITOR LOCATION. INSTALL EXISTING MONITOR SALVAGED FROM OTHER
AREAS IN THE HOSPITAL SCHEDULED TO BE RE-USED AS PART OF THIS PROJECT. IF
THE BALANCE OF EXISTING MONITOR SALVAGED IS LESS THAN THE NEW MONITORS
REQUIRED, PROVIDE NEW MONITORS AS SPECIFIED. INSTALLATIONS ON FIRE RATED
WALLS SHALL BE PROVIDED WITH THE PROPER UL LISTED ASSEMBLY TO
MAINTAINING THE FIRE RATING OF THE STRUCTURE.
RE-PURPOSE EXISTING DATA OUTLET. RELOCATE BEHIND MONITOR AS REQUIRED.
NO EXISTING DATA OUTLET. PROVIDE NEW FROM THE IT CLOSET IDENTIFIED AND
INSTALL BEHIND THE MONITOR.
NO EXISTING POWER OUTLET. PROVIDE NEW HOSPITAL GRADE DUPLEX RECEPTACLE
AND CONNECT TO THE NEAREST RECEPTACLE CIRCUIT WITH (2) #12, (1) #12G IN 3/4"
CONDUIT.
CAREFULLY REMOVE EXISTING ,MONITOR, MOUNTING STRUCTURE, POWER AND TV
OUTLETS. SALVAGE EXISTING MONITOR AND MOUNTING STRUCTURE FOR RE-USE AS
PART OF THIS PROJECT. PATCH AND PAINT WALL TO MATCH EXISTING.
REPLACE EXISTING SIMPLEX OUTLET WITH DUPLEX.
PROVIDE NEW MODULAR PATCH PANEL AND MOUNT ON EXISTING 2-POST RACK.
PROVIDE NEW UTP CABLING AND TERMINATE ON EXISTING PANDUIT DP6 PLUS OPEN
PORT.
B
C
D
E
F
G
H
I
J
CONSULTANTS:
Drawing Title
Approved:
Project Title:
Location:
Date: Checked: Drawn:
Drawing Number
Dwg. of
Building Number
Project Number
Office of Construction and Facilities Management
VA FORM 08-6231
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
A
B
C
D
E
F
6 " o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t
209 SANDUSKY STREET
PITTSBURGH, PA 15212
PH: 412.287.7333
www.ae-works.com
AE WORKS PROJECT NUMBER:
ARCHITECTS/ENGINEERS:SEAL
Revision# Date
5/ 4/
:1
9:
P M
JEVZ MEDICAL CENTER -
ELECTRONIC SIGNAGE
503-17-103
BK SH
2907 Pleasant Valley Blvd, Altoona, PA 16602
01-E104
BUILDING 1 - FOURTH FLOOR PLAN
05/07/2018 206 17033
BID DOCUMENTS
100% SUBMISSION
NOT TO SCALE
BUILDING 1 - FOURTH FLOOR PLAN
S500
513512A
511 510
509A
504 503 502 553A
S502
552A
548A 547A 547
546 545
S501
542A 542
541A
539A
538537
537B
536A535A
535534
534A533A
516515514
513A 514A
2 BED PATIENT
ROOM
STAIRS
2 BED PATIENT
ROOM
PATIENT
BATHROOM
JANITOR OFFICE
PATIENT
BATHROOM
2 BED PATIENT
ROOM
ACTIVITY
BATHROOM
ELECTRICAL
CLOSET
SOILED
UTILITY UNI-SEX
TOILET
MEDS/OMNI
CELL
NOURISH
ROOM
LINEN
ROOM
ELECTRICAL
CLOSET
CORRIDOR
HEARTH
ROOM
STAIR
TEL
CLOSET
WHEEL
CHAIR
STORAGE
1 BED PATIENT
ROOMCONFERENCEBREAK
ROOM
UNI-SEX
TOILET
PATIENT
BATHROOM
PATIENT
BATHROOM
1 BED PATIENT
ROOM PATIENT
BATHROOM
TUB
ROOM/BARBER
LAUNDRY
ROOM
STAIR
EX
SOILED
UTILITY
PATIENT
BATHROOM
1 BED PATIENT
ROOM
1 BED PATIENT
ROOM
PATIENT
BATHROOM
STORAGENRC
SVC
PATIENT
BATHROOM
1 BED PATIENT
ROOM
PATIENT
BATHROOM
1 BED PATIENT
ROOMDAY ROOM
ELECTRICAL
CLOSET
2 BED PATIENT
ROOM
PATIENT
BATHROOM
PATIENT
BATHROOM
2 BED PATIENT
ROOM
2 BED PATIENT
ROOM
PATIENT
BATHROOM
PATIENT
BATHROOM
1 BED PATIENT
ROOM
LPN
ALCOVE
HEARTH
ROOMPATIENT
PANTRY
DINING
ROOM
2 BED PATIENT
ROOM
PATIENT
BATHROOM
PATIENT
BATHROOM
T V
T V
A
E
N
E
E
LWSF-14
J
IT CLOSETN
N
N
C
E
F
A
KEYED NOTES
EXISTING MONITOR ACCEPTS HDMI CONNECTION.
EXISTING MONITOR NEEDS TO BE REPLACED.
NEW MONITOR LOCATION. INSTALL EXISTING MONITOR SALVAGED FROM OTHER
AREAS IN THE HOSPITAL SCHEDULED TO BE RE-USED AS PART OF THIS PROJECT. IF
THE BALANCE OF EXISTING MONITOR SALVAGED IS LESS THAN THE NEW MONITORS
REQUIRED, PROVIDE NEW MONITORS AS SPECIFIED. INSTALLATIONS ON FIRE RATED
WALLS SHALL BE PROVIDED WITH THE PROPER UL LISTED ASSEMBLY TO
MAINTAINING THE FIRE RATING OF THE STRUCTURE.
R…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.