36C24418B0604-003.pdf

PDF 14 MB Posted

Attached to
Provide Electronic Signage, NRM 503-17-103
Solicitation number
36C24418B0604
Issued by

About this file

36C24418B0604 Final Drawings_503-17-103_Provide Electronic Signage.pdf

View the file

Other files

File Type Posted
36C24418B0604-0002000.docx DOCX document
36C24418B0604-0001002.pdf PDF
36C24418B0604-0001000.docx DOCX document
36C24418B0604-0001001.pdf PDF
36C24418B0604-0001003.pdf PDF
36C24418B0604-002.pdf PDF
36C24418B0604-004.docx DOCX document
36C24418B0604-006.docx DOCX document
36C24418B0604-005.docx DOCX document
36C24418B0604-001.docx DOCX document
36C24418B0604-000.docx DOCX document
Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CONSULTANTS:

Drawing Title

Approved:

Project Title:

Location:

Date: Checked: Drawn:

Drawing Number

Dwg. of

Building Number

Project Number

Office of Construction and Facilities Management

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

A

B

C

D

E

F

6 " o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t

209 SANDUSKY STREET

PITTSBURGH, PA 15212

PH: 412.287.7333

www.ae-works.com

AE WORKS PROJECT NUMBER:

ARCHITECTS/ENGINEERS:SEAL

Revision# Date

5/ 7/

1:

:3

A

M JEVZ MEDICAL CENTER -

ELECTRONIC SIGNAGE

503-17-103

BK SH

2907 Pleasant Valley Blvd, Altoona, PA 16602

G001

COVER SHEET

05/07/2018 20 17033

BID DOCUMENTS

100% SUBMISSION

PROVIDE ELECTRONIC

SIGNAGE

JAMES E. VAN ZANDT VA MEDICAL CENTER

2907 PLEASANT VALLEY BLVD.

ALTOONA, PA 16602

VICINITY MAP

SITE

LOCATION MAP

SITE

PROJECT DIRECTORY

OWNER:

JAMES E. VAN ZANDT VA MEDICAL CENTER

2907 PLEASANT VALLEY BLVD.

ALTOONA, PA 16602

(814) 943-8164

CONTACT: NICHOLAS A. CHABON PE, PMP

ARCHITECT/ENGINEER:

AE WORKS, LTD

209 SANDUSKY STREET

PITTSBURGH, PA 15206

(412) 287-7333

CONTACT: STEVE HORVATH

DRAWING INDEX

SHEET # SHEET NAME

E001 ELECTRICAL SYMBOLS, ABBREVIATIONS, NOTES AND SHEET INDEX

01-E10B BUILDING 1 - BASEMENT PLAN

01-E101 BUILDING 1 - FIRST FLOOR PLAN

01-E102 BUILDING 1 - SECOND FLOOR PLAN

01-E103 BUILDING 1 - THIRD FLOOR PLAN

01-E104 BUILDING 1 - FOURTH FLOOR PLAN

01-E105 BUILDING 1 - FIFTH FLOOR PLAN

01-E106 BUILDING 1 - SIXTH FLOOR PLAN

01-E107 BUILDING 1 - SEVENTH FLOOR PLAN

G001 COVER SHEET

02-E101 BUILDING 2 - FIRST FLOOR PLAN

03-E101 BUILDING 3 - FIRST FLOOR PLAN

07-E101 BUILDING 7 - FIRST FLOOR PLAN

22-E101 BUILDING 22 - FIRST FLOOR PLAN

32-E101 BUILDING 32 - FIRST FLOOR PLAN

D-E201 CBOC - DUBOIS FLOOR PLAN

H-E601 CBOC - HUNTINGDON FLOOR PLAN

I-E501 CBOC - INDIANA FLOOR PLAN

J-E301 CBOC - JOHNSTOWN FLOOR PLAN

SC-E401 CBOC - STATE COLLEGE FLOOR PLAN

E701 SYSTEM RISER DIAGRAM AND GENERAL DETAILS

SEALSEAL

RECEPTACLES, FURNITURE FEEDS

THE ABOVE MOUNTING ELEVATIONS ARE TO CENTER OF DEVICE AND SHALL BE ADHERED

TO UNLESS SPECIFICALLY NOTED OR DETAILED OTHERWISE ON THE DRAWINGS AND/OR

SPECIFICATIONS.

IN FLOOR JUNCTION BOXES FLUSH TO

FINISHED FLOOR (FF)

IN MASONRY CONSTRUCTION THE MOUNTING HEIGHTS SHALL BE USED FOR REFERENCE TO

THE NEAREST BLOCK OR BRICK COURSING.

COORDINATE THE INSTALLATION AND MOUNTING ELEVATIONS OF ALL EQUIPMENT, DEVICES,

CONTROLS AND APPURTENANCES WITH ARCHITECT AND ALL AFFECTED TRADES PRIOR TO

INSTALLATION. DOCUMENT ALL MOUNTING ELEVATIONS FOR ALL EQUIPMENT, DEVICES,

CONTROLS AND APPURTENANCES AT THE TIME OF SHOP DRAWING SUBMITTAL.

3.

2.

1.

0'-0"

1'-5" A.F.F.

STANDARD MOUNTING HEIGHTS

RECESSED LIGHTING FIXTURES, CEILING

MOUNTED RECEPTACLES, INDICATING LIGHTS,

ETC.

CEILING

ABOVE COUNTER DEVICES, GFI RECEPTACLES IN

RESTROOMS.

3'-6" A.F.F.

WALL SWITCHES, THERMOSTATS, CONTROL DEVICES,

TO CENTER OF BOX

4'-0" A.F.F.

TOP OF PANELBOARDS (<6'-0" TALL)6'-0" A.F.F.

TOP MOST PORTION OF OPERATING HANDLE OF

DISCONNECT SWITCHES / CIRCUIT BREAKERS

6'-6" A.F.F.

WALL MOUNTED LIGHTS IN STAIRS, MECH ROOMS,

ETC.

7'-0" A.F.F.

REVISION TRIANGLE WITH REVISION CLOUD

INDICATED MOUNTED ABOVE COUNTERTOP (REFER TO STANDARD

MOUNTING HEIGHTS DETAIL ON THIS SHEET)

X - Y

RECEPTACLE TAG:

X= PANEL NAME

Y= CIRCUIT NUMBER

ADA INSTALLATION GUIDELINES

34"

46"

MAX.

(NOTE #2)

44"

MAX.

(FOR 20-25")

(NOTE #2)

10-24" 25" MAX.

48"

MAX.

(FOR 20")

(NOTE #2)

OBSTRUCTED HIGH

SIDE REACH

OBSTRUCTED HIGH

FORWARD REACH

48"

MAX.

(NOTE #2)

10"

MAX.

15"

MIN.

48"

MAX.

(NOTE #2)

15"

MIN.

OBSTRUCTED

SIDE REACH

OBSTRUCTED

FORWARD REACH

NOTES:

1. THESE GUIDLINES SHALL BE USED FOR THE INSTALLATION OF THE FOLLOWING

DEVICES:

- WALL SWITCHES

-CONTROL SWITCHES

-RECEPTACLES

-VISUAL DISPLAY TOUCH PANELS

2. NOTE THAT THIS HEIGHT IS TO THE TOP-MOST PART OF THE DEVICE THAT AN

OCCUPANT REQUIRES ACCESS TO.

ANNOTATION SYMBOLS

DRAWING KEYNOTE - PLAN / ELEVATION NEW WORK1

AREA OF WORK

N NEW DEVICE

E EXISTING DEVICE

APPLICABLE CODES AND STANDARDS

1. LIFE SAFETY CODE - NFPA 101, 2015

2. INTERNATIONAL BUILDING CODE - IBC, 2015

3. NATIONAL ELECTRICAL CODE - NFPA 70, 2017

4. HEALTHCARE FACILITIES CODE - NFPA 99, 2012

5. VA DESIGN REQUIREMENTS

A. ELECTRICAL DESIGN MANUAL FOR NEW HOSPITALS, REPLACEMENT HOSPITALS,

AMBULATORY CARE CLINICAL ADDITIONS, ENERGY CENTERS, OUTPATIENT CLINICS,

ANIMAL RESEARCH FACILITIES, LABORATORY BUILDINGS – DECEMBER 1, 2015

B. FIRE PROTECTION DESIGN MANUAL – DECEMBER 2015

C. TELECOMMUNICATIONS AND SPECIAL TELECOMMUNICATIONS SYSTEMS DESIGN

MANUAL – FEBRUARY 1, 2016

ELECTRICAL SYMBOLS LEGEND

DUPLEX RECEPTACLE IN A 4" SQUARE BOX WITH PLASTER RING (IN DRYWALL)

SINGLE GANG BOX IN MASONRY.

DOUBLE DUPLEX RECEPTACLE IN A 4" SQUARE BOX

NEW FIRE RATED SLEEVE. ALL PENETRATIONS OF WALLS AND/OR FLOORS

SHALL BE FIRE STOPPED IN ACCORDANCE WITH THE ASTM AND NFPA

REQUIREMENTS FOR 2-HOUR FIRE RATING. REFER TO RELATED

SPECIFICATION SECTIONS FOR ADDITIONAL INFORMATION. INSTALLATION OF

FIRE-STOPS SHALL BE PERFORMED BY APPLICATOR/INSTALLER QUALIFIED AND

TRAINED BY THE MANUFACTURER. INSTALLATION SHALL BE PERFORMED IN

STRICT ACCORDANCE WITH MANUFACTURER'S DETAILED INSTALLATION

PROCEDURES.

WALL MOUNTED DATA OUTLET - PROVIDE DOUBLE GANG BACKBOX W/ SINGLE

GANG DEVICE RING, 1 1/4" EMT CONDUIT W/ PULLSTRING TO ABOVE

ACCESSIBLE CEILING.

SYSTEMS SYMBOLS LEGEND

NEW CATEGORY 6 UTP CABLE - PLENUM RATED

TV TELEVISION/MONITOR WITH HDMI CONNECTION

CONSULTANTS:

Drawing Title

Approved:

Project Title:

Location:

Date: Checked: Drawn:

Drawing Number

Dwg. of

Building Number

Project Number

Office of Construction and Facilities Management

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

A

B

C

D

E

F

6 " o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t

209 SANDUSKY STREET

PITTSBURGH, PA 15212

PH: 412.287.7333

www.ae-works.com

AE WORKS PROJECT NUMBER:

ARCHITECTS/ENGINEERS:SEAL

Revision# Date

5/ 4/

:1

9:

P M

JEVZ MEDICAL CENTER -

ELECTRONIC SIGNAGE

503-17-103

BK SH

2907 Pleasant Valley Blvd, Altoona, PA 16602

E001

ELECTRICAL SYMBOLS, ABBREVIATIONS,

NOTES AND SHEET INDEX

05/07/2018 201 17033

BID DOCUMENTS

100% SUBMISSION

SP STANDPIPE OR STATIC PRESSURE

SPC SPECIMEN PASS-THRU CABINET

SPEC SPECIFICATIONS

SPS STATIC PRESSURE SENSOR

SR SERVICE RECEPTOR

SS SOIL STACK

ST PR STATIC PRESSURE

ST STL STAINLESS STEEL

STD STANDARD

STER STERILIZER

STL STEEL

STOR STORAGE

STR STRAINER

STRUCT STRUCTURAL

SUSP SUSPENDED

SW SWITCH

SWBD SWITCHBOARD

SWGR SWITCHGEAR

SYM SYMMETRICAL TOP

T TOP

TA THROWAWAY

TAN TANGENT

TC TELECOMMUNICATIONS

CONTRACTOR

TCV TEMPERATURE CONTROL VALVE

TDV TRIPLE DUTY VALVE

TEL TELEPHONE

TEMP TEMPERATURE

TER TERRAZZO

TG TONGUE & GROOVE

TH THERMOMETER

THRES THRESHOLD

TR TEMPERATURE RISE

TRANS TRANSITION

TRANSR TRANSFORMER

TSTAT THERMOSTAT

TV TURNING VANES OR TELEVISION

TYP TYPICAL

UC UNDER CABINET OR UNDER CUT

UFD UNDER FLOOR DUCT

UG UNDERGROUND

UH UNIT HEATER

UL UNDERWRITER'S LABORATORIES

UNFIN UNFINISHED

UNO UNLESS NOTED OTHERWISE

UPS UNINTERRUPTIBLE POWER SUPPLY

UTIL UTILITY

V VOLT

VAL VALVE

VD VOLUME DAMPER

VENT VENTILATION

VERT VERTICAL

VFS VENTURI FLOW STATION

VIF VERIFY IN FIELD

VL VENT LINE

VR VAPOR RETARDER

VS VENT STACK

VTR VENT THROUGH ROOF

W WATT

W/ WITH

W/O WITHOUT

WB WET BULB

WC WALL COVERING

WCL WATER CLOSET

WD WOOD

WF WIDE FLANGE

WFMD WATER FLOW MEASURING DEVICE

WG WALL GUARD OR WATER GAUGE

WHCH WHEEL CHAIR

WIN WINDOW

WMS WIRE MESH SCREEN

WP WEATHERPROOF

WPS WALL PROTECTION SYSTEM

WSCT WAINSCOT

WT WINDOW TREATMENT

WTD WATER TEMPERATURE DROP

WWF WELDED WIRE FABRIC

X DEMO

XN TO BE RELOCATED / NEW LOCATION

XR EXISTING TO REMAIN

ZVB ZONE VALVE BOX

ZVC ZONE VALVE CABINET

LAT LEAVING AIR TEMPERATURE

LAV LAVATORY

LB POUND

LDB LEAVING DRY BULB

LED LIGHT EMITTING DIODE

LF LINEAR FEET

LIN LINEAR

LOC LOCATION OR LOCATE

LPT LOW POINT

LSDC LINEAR SUPPLY DIFFUSER CEILING

LT LIGHT

LTG LIGHTING

LV LOW VOLTAGE

LVR LOUVER

LWB LEAVING WET BULB

LWC LINEAR WOOD CEILING

LWT LEAVING WATER TEMPERATURE

MAN MANUAL

MAT MIXED AIR TEMPERATURE

MATL MATERIAL

MAV MANUAL AIR VENT

MAX MAXIMUM

MBH ONE THOUSAND BTU / HOUR

MC MECHANICAL CONTRACTOR

MC METAL CLAD CABLE

MCB MAIN CIRCUIT BREAKER

MCC MOTOR CONTROL CENTER

MDP MAIN DISTRIBUTION PANEL

MECH MECHANICAL

MEMB MEMBRANE

MET METAL

MFR MANUFACTURER

MH MANHOLE

MIN MINIMUM

MISC MISCELLANEOUS

MLO MAIN LUGS ONLY

MO MASONRY OPENING

MOD MOTOR OPERATED DAMPER

MONO MONOLITHIC

MTD MOUNTED

MTG HT MOUNTING HEIGHT

MTL METAL

MTLH METAL HALIDE

MTR MOTOR

MTS MANUAL TRANSFER SWITCH

MV MEDIUM VOLTAGE

N/A NOT APPLICABLE

NEC NATIONAL ELECTRIC CODE

NEMA NATIONAL ELECTRICAL

MANUFACTURER ASSOCIATION

NIC NOT IN CONTRACT

NL NIGHT LIGHT

NO NUMBER OR NORMALLY OPEN

NOM NOMINAL

NTS NOT TO SCALE

O OXYGEN

OA OUTSIDE AIR

OBD OPPOSED BLADE DAMPER

OC ON CENTER

OD OUTSIDE DIAMETER

OPER OPERATED

OPNG OPENING

OPP OPPOSITE

ORD OVERFLOW ROOF DRAIN

PB PULL BOX

PC PLUMBING CONTRACTOR

PD PUMP DISCHARGE

PG PRESSURE GAUGE WITH COCK

PL PROPERTY LINE

PLAM PLASTIC LAMINATE

PLBG PLUMBING

PNL PANEL

PR PAIR

PRD PRESSURE DIFFERENTIAL VALVE

PRELIM PRELIMINARY

PRT PRESSURE TAP

PRV PRESSURE REDUCING VALVE

PT PAINT OR POTENTIAL

TRANSFORMER

RO ROUGH OPENING

QT QUARRY TILE

R RADIUS

RA RETURN AIR / RELIEF AIR

RB RUBBER BASE

RC REMOVE COMPLETELY

RD ROOF DRAIN

RE RELOCATE EXISTING

REC RECESSED

RECPT RECEPTACLE

REF REFERENCE

REFL REFLECTOR

REG REGISTER

REINF REINFORCING

REM REMOVE

REQD REQUIRED

RET RETURN

REV REVISE

REX REMOVE EXISTING

RF RESILIENT FLOOR

RFI REQUEST FOR INFORMATION

RGS RIGID GALVANIZED STEEL CONDUIT

RH ROOF HATCH

RM ROOM

RN REMOVE AND REPLACE WITH NEW

RR REMOVE AND REPLACE

RS RAPID START

RV RELIEF VALVE

RWC RAIN WATER CONDUCTOR

SA SUPPLY AIR

SAN SANITARY SEWER ABOVE GROUND

SAN-BXR SANITARY SEWER - BURIED

EXISTING TO REMAIN

SAN-XR SANITARY SEWER ABOVE GROUND -

EXISTING TO REMAIN

SCHED SCHEDULE

SD SMOKE DAMPER OR SMOKE

DETECTOR

SDISP SOAP DISPENSER

SF SQUARE FOOT

SHT SHEET

SHT MTL SHEET METAL

SHTG SHEATHING

SIM SIMILAR

SM SURFACE MOUNTED

SNC SANITARY NAPKIN CABINET

SND SANITARY NAPKIN DISPOSER

EF EXHAUST FAN

EIFS EXTERIOR INSULATION AND

FINISHING SYSTEM

EJ EXPANSION JOINT

EL ELEVATION

ELEC ELECTRICAL

ELEC CAB ELECTRICAL CABINET

ELEV ELEVATOR

EMER EMERGENCY

ENCL ENCLOSURE

ENTR ENTRANCE

EO ELECTRICAL OUTLET

EQ EQUAL

EQUIP EQUIPMENT

ETR EXISTING TO REMAIN

EWB ENTERING WET BULB

EWC ELECTRIC WATER COOLER

EWT ENTERING WATER TEMPERATURE

EX EXAUST AIR

EXH EXHAUST

EXIST EXISTING

EXP EXPANSION

EXT EXTERIOR

XP EXPLOSION PROOF

F/S FIRE / SMOKE DAMPER

FA FIRE ALARM

FAAP FIRE ALARM ANNUNCIATOR PANEL

FACP FIRE ALARM CONTROL PANEL

FAT FINAL AIR TEMPERATURE

FB FIRE BLANKET

FC FLEXIBLE CONNECTION OR

FOOTCANDLE

FD FLOOR DRAIN OR FIRE DAMPER

FDN FOUNDATION

FDV FIRE DEPARTMENT VALVE

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FH FIRE HOSE

FHC FIRE HOSE CABINET

FHP FULL HEIGHT PARTITION

FHV FIRE HOSE VALVE

FIN FINISH

FIXT FIXTURE

FL FLOW LINE

FLA FULL LOAD AMPERES

FLASH FLASHING

FLEX FLEXIBLE

FLG FLANGE

FLG C FLANGE CONNECTION

FLR FLOOR

FLUOR FLUORESCENT

FP FIRE PROOFING

FRMG FRAMING

FS FLOOR SINK

FSTOP FIRESTOPPING

FT FOOT / FEET

FT HD FEET OF HEAD

FTC FOOTCANDLES

FTG FOOTING

FUR FURRING

G GAS OR ELECTRICAL GROUND

GA GAUGE

GAL GALLONS

GALV GALVANIZED

GB GRAB BAR

GC GENERAL CONTRACTOR

GEN GENERATOR

GENL GENERAL

GFCI GROUND FAULT CIRCUIT

INTERRUPTOR

GL GLASS

GLV GLOBE VALVE

GND GROUND

GPM GALLONS PER MINUTE

GR GRADE

GRAV GRAVITY

GRD BM GRADE BEAM

GV GATE VALVE

GWB GYPSUM BOARD

H HIGH

HB HOSE BIB

HC HEATING CONTRACTOR

HDCP HANDICAP

HDR HEADER

HDW HARDWARE

HID HIGH INTENSITY DISCHARGE

HM HOLLOW METAL

HORIZ HORIZONTAL

HP HORSE POWER

HPD HIGH PRESSURE DRIP

HPF HIGH POWER FACTOR

HR HANDRAIL

HSKP HOUSEKEEPING

HT HEIGHT

HTG HEATING

HTR HEATER

HV HIGH VELOCITY

HVAC HEATING, VENTILATING, AIR

CONDITIONING

HW HOT WATER

HWD HARD WOOD

HWR HOT WATER RETURN

HWS HOT WATER SUPPLY

HWS&R HOT WATER SUPPLY AND RETURN

HZ HERTZ

ID INSIDE DIAMETER

IER INVERTED ECCENTRIC REDUCER

IG ISOLATED GROUND

IME INSULATED METAL ENCLOSURE

IN INCH

INCAND INCANDESCENT

INCL INCLUDED

INSUL INSULATION

INT INTERIOR

INTERL INTERLOCK

INV INVERT

ISO ISOLATION

IVS ISOLATED VALVE STATION

J-BOX JUNCTION BOX

JST JOIST

JT JOINT

KO KNOCK OUT

kVA KILOVOLT AMPERE kVAR KILOVAR (REACTANCE) kW KILOWATT kWH KILOWATT HOUR METER

& AND

A AIR (CLINICAL)

AAP ALARM ANNUNCIATOR PANEL

AAV AUTOMATIC AIR VENT

AB ANCHOR BOLT

ABV ABOVE

ACC DR ACCESS DOOR

ACFL ACCESS

ACOUS ACOUSTICAL

ACT ACOUSTICAL CEILING TILE

AD AREA DRAIN

ADA AMERICAN DISABILITIES ACT

ADD ADDENDUM

ADDL ADDITIONAL

ADJ ADJUSTABLE

ADMIN ADMINISTRATION

AFF ABOVE FINISH FLOOR

AFG ABOVE FINISHED GRADE

AFMD AIR FLOW MEASURING DEVICE

AHU AIR HANDLING UNIT

AL ALIGN

ALT ALTERNATE

ALUM ALUMINUM

AMP AMPERE

AP ACCESS PANEL

APC ARCHITECTURAL PRECAST

CONCRETE

APPROX APPROXIMATE

ARCH ARCHITECTURAL

ASY ASYMMETRIC

ATC AUTOMATIC TEMPERATURE

CONTROL

ATS AUTOMATIC TRANSFER SWITCH

AUTO AUTOMATIC

AWT AVERAGE WATER TEMPERATURE

BAT BATTERY

BC BALANCING COCK OR BARE

COPPER

BDD BACKDRAFT DAMPER

BFC BELOW FINISH CEILING

BFE BOTTOM FOOTING ELEVATION

BFG BELOW FINISHED GRADE

BG BUMPER GUARD

BLDG BUILDING

BLKG BLOCKING

BLT BORROWED LIGHT

BLW BELOW

BM BEAM

BO BY OWNER

BOF BY OWNER FUTURE

BOT BOTTOM

BR BRICK

BRG BEARING

BRKR BREAKER

BSMT BASEMENT

BTWN BETWEEN

BUR BUILT UP ROOFING

C CONDUIT

CAB CABINET

CANTL CANTILEVER

CAP CAPACITY

CATV CABLE TELEVISION

CCT CUBICLE CURTAIN TRACK

CCTV CLOSED CIRCUIT TELEVISION

CFH CUBIC FEET / HOUR

CFM CUBIC FEET / MINUTE

CH CHANNEL

CHK V CHECK VALVE

CHWR CHILLED WATER RETURN

CHWS CHILLED WATER SUPPLY

CHWS&R CHILLED WATER SUPPLY AND

RETURN

CJ CONTROL JOINT

CKT CIRCUIT

CKT BRKR CIRCUIT BREAKER

CL CENTERLINE

CLG CEILING

CLG MTD CEILING MOUNTED

CLR CLR

CMU CONCRETE MASONRY UNIT

CO CLEAN OUT

COL COLUMN

COMM COMMUNICATION

CONC CONCRETE

CONN CONNECTION

CONST CONSTRUCTION

CONT CONTINUE / CONTINUOUS

CONTR CONTRACTOR

CONV CONVECTOR

COORD COORDINATE

CORR CORRIDOR

CPT CARPET OR CONTROL POWER

TRANSFORMER

CT CERAMIC TILE

CTR CENTER

CU COPPER

CV CONTROL VALVE

CW COLD WATER

D DEPTH OR DEEP

DB DRY BULB

dB DECIBEL

DCW DOMESTIC COLD WATER

DEMO DEMOLITION

DEPT DEPARTMENT

DET DETAILS

DF DRINKING FOUNTAIN

DHW DOMESTIC HOT WATER

DIA DIAMETER

DIAG DIAGONAL OR DIAGRAM

DIFF DIFFUSER

DIM DIMENSION

DISC DISCONNECT

DISCH DISCHARGE

DISP DISPENSER

DIST DISTRIBUTION

DIV DIVISION

DL DOWN LIGHT

DN DOWN

DP DISTRIBUTION PANEL

DPR DAMPER

DR DRAIN

DS DOWNSPOUT

DWG DRAWING

DX DIRECT EXPANSION

EA EXHAUST AIR

EAT ENTERING AIR TEMPERATURE

EC ELECTRICAL CONTRACTOR

EDB ENTERING DRY BULB

ABBREVIATION LEGEND ELECTRICAL GENERAL NOTES

1 THE FOLLOWING GENERAL NOTES AS LISTED BELOW SHALL APPLY TO ALL ELECTRICAL REQUIREMENTS AS INDICATED ON ALL E SERIES CONTRACT DRAWINGS.

2 THE CONTRACTOR IS RESPONSIBLE FOR THE ENTIRE DOCUMENT SET. IF WORK IS SHOWN ON OTHER DRAWINGS AS "BY CONTRACTOR" THE CONTRACTOR IS

RESPONSIBLE FOR THAT WORK.

3 DRAWINGS FOR THIS WORK ARE DIAGRAMMATIC AND INTENDED TO CONVEY THE EXTENT, GENERAL ARRANGEMENT AND LOCATIONS OF THE WORK. BECAUSE OF THE SCALE OF THE DRAWINGS, CERTAIN BASIC ITEMS SUCH AS ACCESS PANELS, CONDUITS, CABINET SIZES, PENETRATION SLEEVES, PULL BOXES, BACKBOXES AND JUNCTION BOXES MAY NOT BE SHOWN. INCLUDE ALL ITEMS WHERE REQUIRED BY CODE, MANUFACTURER AND RELATED SPECIFICATION

SECTIONS FOR THE PROPER INSTALLATION OF ALL WORK.

4 DUE TO SCALE OF THE DRAWINGS, ALL ELECTRICAL DEVICE SYMBOLS ARE SHOWN ON DRAWINGS AS CLOSE AS POSSIBLE TO THEIR INTENDED LOCATION.

CONTRACTOR SHALL COORDINATE IN THE FIELD THE PROPER INSTALLATION OF ALL EQUIPMENT, DEVICES, CONTROLS AND CONDUITS. REFER TO RELATED

SPECIFICATION SECTIONS FOR ADDITIONAL REQUIREMENTS.

5 COORDINATE WITH ALL TRADES AND SYSTEM INTEGRATORS ANY CONDITIONS RELATED TO THE INSTALLATION OF ALL SYSTEMS. THE CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE TRADE ALL INSTALLATION REQUIREMENTS IMPACTING THE PLACEMENT OF ALL SYSTEM COMPONENTS TO THE

SATISFACTION OF ALL CONCERNED TRADES.

6 COORDINATE EXACT LOCATION(S) OF ALL DATA AND TELEPHONE OUTLETS, ELECTRICAL RECEPTACLES WITH EXISTING FURNITURE AND ALL AFFECTED TRADES

PRIOR TO INSTALLATION.

7 ALL CONDUITS SHALL BE SIZED AND INSTALLED IN ACCORDANCE WITH NFPA 70 AND PROJECT SPECIFICATIONS. ALL CONDUITS SHALL BE A MINIMUM OF 3/4"

UNLESS OTHERWISE NOTED.

8 PROVIDE ALL EQUIPMENT CLEARANCES IN ACCORDANCE WITH NEC REQUIREMENTS. ARRANGE EQUIPMENT TO FACILITATE UNRESTRICTED ACCESS FOR MAINTENANCE AND SERVICE AROUND ALL EQUIPMENT, COMPONENTS AND/OR CABLE TERMINATIONS.

9 WHERE EQUIPMENT AND/OR JUNCTION BOXES ARE INSTALLED ABOVE FINISHED CEILINGS, THE CONTRACTOR SHALL PROVIDE ACCESS HATCHES LISTED FOR THE INTENDED APPLICATION. ACCESS HATCHES SHALL BE LOCATED SO THAT SERVICE ACCESS TO THE EQUIPMENT AND/OR JUNCTION BOXES IS UNIMPEDED.

10 ALL PENETRATIONS OF WALLS AND/OR FLOORS SHALL BE FIRE STOPPED IN ACCORDANCE WITH THE ASTM AND NFPA REQUIREMENTS. REFER TO RELATED SPECIFICATION SECTIONS FOR ADDITIONAL INFORMATION. INSTALLATION OF FIRE-STOPS SHALL BE PERFORMED BY APPLICATOR/INSTALLER QUALIFIED AND TRAINED BY THE MANUFACTURER. INSTALLATION SHALL BE PERFORMED IN STRICT ACCORDANCE WITH MANUFACTURER'S DETAILED INSTALLATION

PROCEDURES.

11 ALL EQUIPMENT ENCLOSURES LOCATED OUTSIDE OR IN ALL AREAS WITH HIGH MOISTURE OR A RELATIVE HUMIDITY OF 75% OR GREATER SHALL BE NEMA 4X

STAINLESS STEEL AND RATED FOR THAT APPLICATION.

12 ALL DEVICES, COMPONENTS OR EQUIPMENT INSTALLED ON THE EXTERIOR OF THE FACILITY SHALL BE PROVIDED IN ACCORDANCE WITH ALL MANUFACTURERS' REQUIREMENTS TO ENSURE THE PROPER OPERATION WHEN EXPOSED TO THE ENVIRONMENTAL CONDITIONS AND/OR AVERAGE ANNUAL LOWEST

TEMPERATURE THAT CAN BE ANTICIPATED FOR THE GEOGRAPHIC REGION OF THE FACILITY.

13 ALL INTERIOR AND/OR EXTERIOR COMPONENTS, DEVICES OR SYSTEMS EQUIPMENT EXPOSED TO THE GENERAL POPULATION SHALL BE INSTALLED IN SECURED EQUIPMENT ENCLOSURES WITH TAMPER SWITCHES AND INSTALLED IN SUCH A MANNER THAT RESISTS TAMPERING AND/OR REMOVAL WITHOUT THE USE OF

SPECIALIZED TOOLS.

14 FOR EQUIPMENT INSTALLATIONS REQUIRING COORDINATION WITH OTHER TRADES THE CONTRACTOR SHALL PROVIDE ALL TEMPLATES, BACKBOXES AND EQUIPMENT ANCHOR BOLTS FOR MOUNTING OR FLUSH MOUNTING PREPARATION, (E.G. PEDESTALS OR OTHER DEVICES REQUIRING MOUNTING ON WALLS, CONCRETE PADS OR OTHER MATERIALS). COORDINATE DELIVERY OF TEMPLATES AND EQUIPMENT WITH ALL AFFECTED CONTRACTORS.

15 ALL ELECTRICAL WORK SHALL BE DONE IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE (LATEST VERSION BEING ENFORCED), AND ALL OTHER APPLICABLE CODES AND STANDARDS BEING ENFORCED BY THE AUTHORITY HAVING JURISDICTION.

16 THESE DRAWINGS DO NOT INCLUDE NECESSARY COMPONENTS OR INSTRUCTIONS FOR CONSTRUCTION SAFETY. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR ANY WORKMAN'S OR TRANSIENT'S SAFETY, OR FOR THE ADEQUACY OF EQUIPMENT, BUILDING COMPONENTS, WORK AIDS, OR ANY NECESSITY TO WORK ON ENERGIZED ELECTRICAL COMPONENTS. FURTHER, NO SUPERINTENDENCE IS INCLUDED OR IMPLIED.

17 ALL SYSTEMS AND EQUIPMENT SHALL BE INSTALLED AND WIRED ACCORDING TO THE MANUFACTURER'S RECOMMENDATIONS.

18 ALL ELECTRICAL MATERIALS, DEVICES, APPLIANCES, AND EQUIPMENT SHALL BE TESTED AND LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY.

19 THE CONTRACTOR SHALL COORDINATE CONDUIT ROUTING (PLAN AND ELEVATION) WITH THE LIGHTING (NEW AND EXISTING), CEILING ELEVATION, STRUCTURE, DUCTWORK, PIPING, ETC. REQUIRED FOR THE COMPLETION OF THE PROJECT, PRIOR TO INSTALLATION.

20 THE DIMENSIONS SHOWN ON THE DRAWINGS ARE FOR THE CONVENIENCE OF THE CONTRACTOR ONLY. VERIFY ALL DIMENSIONS IN THE FIELD PRIOR TO

PERFORMING ANY WORK.

21 THE CONTRACTOR SHALL INSTALL ALL CONDUITS CONCEALED UNLESS NOTED OTHERWISE. EXPOSED CONDUIT SHALL ONLY BE INSTALLED IN CHASES, EXPOSED CEILING AREAS, JANITOR CLOSETS, AND MECHANICAL/ELECTRICAL ROOMS.

22 ALL ELECTRICAL EQUIPMENT SHALL BE GROUNDED AND/OR BONDED PER THE REQUIREMENTS OF THE NATIONAL ELECTRIC CODE. PROVIDE ALL GROUNDING

AND/OR BONDING COMPONENTS NOT EXPLICITLY SHOWN ON THE DOCUMENTS.

23 THE CONTRACTOR SHALL PROVIDE TYPEWRITTEN PANELBOARD DIRECTORIES, INDICATING THE LOADS SERVED BY THE RESPECTIVE PANELS. AMEND AS REQUIRED FOR AS-BUILT CONDITIONS. PROVIDE ELECTRONIC VERSIONS OF THE PANELBOARD SCHEDULES FOR FUTURE USE BY THE OWNER.

24 THE CONTRACTOR SHALL REVIEW THE WORK REQUIRED WITH THE APPLICABLE UTILITY COMPANIES SERVING THE PROJECT. ALL WORKPERFORMED SHALL BE

IN ACCORDANCE WITH THE REQUIREMENTS OF THE INDIVIDUAL UTILITY COMPANIES.

25 THE CONTRACTOR SHALL COORDINATE ALL WORK WITH THE OWNER PRIOR TO STARTING ALL PHASES OF THE PROJECT. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER WHAT WORK, IF ANY, HAS TO BE COMPLETED DURING SECOND OR THIRD SHIFT.

26 THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY POWER CONNECTIONS TO KEEP AREAS UP AND OPERATIONAL DURING THE CONSTRUCTION. THE

CONTRACTOR SHALL COORDINATE THESE REQUIREMENTS WITH THE OWNER.

27 THE VERBIAGE ON THE DRAWINGS INDICATING TYPES OF MATERIALS TO BE ENCOUNTERED IS INTENDED TO AID THE ELECTRICAL CONTRACTOR IN UNDERSTANDING THE VARIOUS CONDITIONS LIKELY TO BE ENCOUNTERED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING QUANTITIES OF

MATERIALS REQUIRED TO COMPLETE THE PROJECT.

28 THE LOCATIONS OF EXISTING UTILITIES, STRUCTURE AND OTHER CONDITIONS SHOWN ON THE PLANS ARE APPROXIMATE. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY AND REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO BEGINNING ANY WORK.

29 THE CONTRACTOR SHALL PROVIDE ALL NEW OPENINGS IN EXISTING PARTITIONS AND FLOORS FOR THE INSTALLATION OF ANY NEW ELECTRICAL WORK.

FURNISH AND INSTALL ALL REQUIRED SLEEVES FOR THIS NEW WORK. ALL CONDUITS SHALL HAVE SLEEVES INSTALLED. ALL THRU-WALL PENETRATIONS SHALL

BE TREATED AS 2-HOUR PENETRATIONS AND INSTALLED IN ACCORDANCE WITH UL-1479.

30 THE CONTRACTOR SHALL PROTECT ALL EXISTING MATERIALS THAT ARE TO REMAIN IN PLACE FROM DAMAGE. ANY DAMAGE TO EXISTING FINISHES, MATERIALS, ETC., SHALL BE REPLACED BY THE CONTRACTOR TO MATCH THE ADJACENT FINISH.

31 THE CONTRACTOR SHALL MAINTAIN THE BUILDING IN WEATHERTIGHT AND WATERPROOF CONDITION THROUGHOUT THE DURATION OF THEIR WORK. DO NOT LEAVE HOLES THROUGH WALLS AND/OR ROOFS OPEN TO THE ELEMENTS WHEN NO WORK IS OCCURRING IN THOSE AREAS.

32 THE CONTRACTOR SHALL PROVIDE ALL TRAFFIC CONTROL, FLAGMEN, SIGNAGE, ETC. WHEN DOING WORK THAT INTERFERES WITH PUBLIC RIGHT-OF-WAY.

33 THE CONTRACTOR SHALL CONTACT THE NATIONAL "811-CALL BEFORE YOU DIG" SYSTEM PRIOR TO PERFORMING ANY UNDERGROUND INSTALLATION WORK.

THE CONTRACTOR SHALL HAVE ALL UTILITIES VERIFIED IN AND AROUND THE EXCAVATION AREA.

34 THE CONTRACTOR SHALL GENERATE A DETAILED METHOD OF PROCEDURE (MOP) DOCUMENT INDICATING HOW HE/SHE INTENDS TO PERFORM EACH STEP IN THE PROJECT. THIS MOP SHALL BE PRESENTED TO THE OWNER AND ENGINEER PRIOR TO STARTING THE PROJECT, FOR SIGN OFF. THE MOP MAY BE REVISED BASED ON CHANGES IN THE PROJECT CONSTRUCTION, ETC. AT ALL POINTS IN THE PROJECT THE OWNER SHALL BE MADE AWARE OF CHANGES TO THE MOP, AND A REVISED MOP SHALL BE PRESENTED TO THE OWNER AND ENGINEER FOR SIGN OFF.

35 PROVIDE ALL JUNCTION BOXES, PULL BOXES AND OTHER PULL POINTS AS REQUIRED TO MEET THE MAXIMUM NUMBER OF BENDS PER NEC REQUIREMENTS.

NOT ALL CONDUITS, PULL BOXES AND OTHER RACEWAY ITEMS ARE INDICATED ON THE DOCUMENTS. THE CONTRACTOR SHALL PROVIDE A COMPLETE RACEWAY

SYSTEM MEETING THE REQUIREMENTS OUTLINED IN THE DRAWINGS AND SPECIFICATIONS.

36 THESE DRAWINGS DO NOT INDICATED ALL CONDUITS INTERCONNECTING EQUIPMENT, AND WHERE CONDUITS ARE INDICATED, THE ROUTING IS APPROXIMATE.

THE CONTRACTOR IS RESPONSIBLE FOR THE ROUTING AND INSTALLATION OF ALL CONDUIT IN COORDINATION WITH OTHER TRADES AND EXISTING CONDITIONS.

37 PROVIDE ALL JUNCTION BOXES AND OTHER PULL POINTSAS REQUIRED FOR EASE OF PULLING AND A CODE COMPLIANT INSTALLATION. ALL JUNCTION BOXES

AND OTHER PULL POINTS SHALL BE ACCESSABLE

38 MULTIWIRE BRANCH CIRCUITS ARE NOT PERMITTED, ALL SINGLE POLE BRANCH CIRCUITS SHALL HAVE A DEDICATED NEUTRAL.

39 MULTIPLE SMALL 20A/1P BRANCH CIRCUITS MAY SHARE A SINGLE CONDUIT PROVIDED THE CONTRATOR UPSIZES THE CONDUIT AS REQUIRED, AND THE

AMPACITY ADJUSTMENTS FROM TABLE 310.15(B) HAVE BEEN APPLIED.

DRAWING INDEX

SHEET # SHEET NAME

E001 ELECTRICAL SYMBOLS, ABBREVIATIONS, NOTES AND SHEET INDEX

01-E10B BUILDING 1 - BASEMENT PLAN

01-E101 BUILDING 1 - FIRST FLOOR PLAN

01-E102 BUILDING 1 - SECOND FLOOR PLAN

01-E103 BUILDING 1 - THIRD FLOOR PLAN

01-E104 BUILDING 1 - FOURTH FLOOR PLAN

01-E105 BUILDING 1 - FIFTH FLOOR PLAN

01-E106 BUILDING 1 - SIXTH FLOOR PLAN

01-E107 BUILDING 1 - SEVENTH FLOOR PLAN

02-E101 BUILDING 2 - FIRST FLOOR PLAN

03-E101 BUILDING 3 - FIRST FLOOR PLAN

07-E101 BUILDING 7 - FIRST FLOOR PLAN

22-E101 BUILDING 22 - FIRST FLOOR PLAN

32-E101 BUILDING 32 - FIRST FLOOR PLAN

D-E201 CBOC - DUBOIS FLOOR PLAN

H-E601 CBOC - HUNTINGDON FLOOR PLAN

I-E501 CBOC - INDIANA FLOOR PLAN

J-E301 CBOC - JOHNSTOWN FLOOR PLAN

SC-E401 CBOC - STATE COLLEGE FLOOR PLAN

E701 SYSTEM RISER DIAGRAM AND GENERAL DETAILS

SEAL

MECH

RM

22 22A

47B

26A

S00

E02

27A

29 29A 30

31 32

32B

32C

47A

28A

18B

18A

17A

16B

16A 17

15C

15A

E00

E00A

E00B

5B

5A

13A

S03

7A

1A

S02

42 41

41A

42A

42B

35 37

37A

48C

S01

A000A

A000 A000C

AS000

A000E

31A

S04

A000K A000J A000I A000H A000G

A000B

A000F

A000D

41C 41B

FD

SF

SF

SF

MECH RM ENG

SVC

ELEC SHOPENG

SVC

CHIEF

M&R

OFFICE

STOR

MACHINE SHOP

PLUMBING

SHOP

ENG

SVC

CARPENTER SHOP ENG

SVC

PLAN

RM

CORR

PAINT

SHOP

M TLT

EMS

STAIRS

ELEV

LOBBY

MAIL ROOM

MAS

STOR

MAS

STORAGE

MAS

BIO-MED

SHOP

STOR

A&MM

FHC

MC

CORR

FHC

MECH RM ENG

SVC

CORR

STORAGE ENG

SVC

LOCKER RM

EMS

SHR

RM

M TLT

EMS

STORAGE

VCS

STOR

REFIRIG

ELEV

ELEV

ELEV

KITCHEN

VCS

DINING RM

VCS

A/C SHOP ENG

SVC

CORR

TELE

EC

FHC

STORAGE

VCS

STAIRS

OFFICE CRED

UN

CRED

UN

OFFICE CRED

UN

LOCKER

RM

CLO

OFFICE

EMS

CH OFF

VCS

RETAIL

STORE

RETAIL

STOR

STAIRS

STOR

VCS

STOR

A&MM

STOR

A&MM

TEL

TEL

CL

SIGN

SH

STOR

A&MM

MECH

RM

UNEXCAVATED

EC

ELEC

CL

HAC

CORR

HAC

STOR

STAIRS

PHARMACY

CACHE

STOR

MECH

MECH

SHAFT

STAIRS

ELEC

UNEXCAVATED

EQ

STOR ELEVATOR

MECH

RM

MECH

PIT

POLICE TRAINING

ROOM

STAIRS

MECHANICAL

ROOM

OFFICE OFFICE OFFICE OFFICE OFFICE

SF

HVAC

SHOP

DATA

PANDEMIC

COMP.

RM

HSK

ROOM

BUILDING 1 -

BASEMENT

T V

T V

T V

A

E

E

N

E

SPBC -1/16

I

N

E

E

IT CLOSET

N

N

N

C

E

F

A

KEYED NOTES

EXISTING MONITOR ACCEPTS HDMI CONNECTION.

EXISTING MONITOR NEEDS TO BE REPLACED.

NEW MONITOR LOCATION. INSTALL EXISTING MONITOR SALVAGED FROM OTHER

AREAS IN THE HOSPITAL SCHEDULED TO BE RE-USED AS PART OF THIS PROJECT. IF

THE BALANCE OF EXISTING MONITOR SALVAGED IS LESS THAN THE NEW MONITORS

REQUIRED, PROVIDE NEW MONITORS AS SPECIFIED. INSTALLATIONS ON FIRE RATED

WALLS SHALL BE PROVIDED WITH THE PROPER UL LISTED ASSEMBLY TO

MAINTAINING THE FIRE RATING OF THE STRUCTURE.

RE-PURPOSE EXISTING DATA OUTLET. RELOCATE BEHIND MONITOR AS REQUIRED.

NO EXISTING DATA OUTLET. PROVIDE NEW FROM THE IT CLOSET IDENTIFIED AND

INSTALL BEHIND THE MONITOR.

NO EXISTING POWER OUTLET. PROVIDE NEW HOSPITAL GRADE DUPLEX RECEPTACLE

AND CONNECT TO THE NEAREST RECEPTACLE CIRCUIT WITH (2) #12, (1) #12G IN 3/4"

CONDUIT.

CAREFULLY REMOVE EXISTING ,MONITOR, MOUNTING STRUCTURE, POWER AND TV

OUTLETS. SALVAGE EXISTING MONITOR AND MOUNTING STRUCTURE FOR RE-USE AS

PART OF THIS PROJECT. PATCH AND PAINT WALL TO MATCH EXISTING.

REPLACE EXISTING SIMPLEX OUTLET WITH DUPLEX.

PROVIDE NEW MODULAR PATCH PANEL AND MOUNT ON EXISTING 2-POST RACK.

PROVIDE NEW UTP CABLING AND TERMINATE ON EXISTING PANDUIT DP6 PLUS OPEN

PORT.

B

C

D

E

F

G

H

I

J

ELECTRICAL SYMBOLS LEGEND

DUPLEX RECEPTACLE IN A 4" SQUARE BOX WITH PLASTER RING (IN DRYWALL)

SINGLE GANG BOX IN MASONRY.

DOUBLE DUPLEX RECEPTACLE IN A 4" SQUARE BOX

NEW FIRE RATED SLEEVE. ALL PENETRATIONS OF WALLS AND/OR FLOORS

SHALL BE FIRE STOPPED IN ACCORDANCE WITH THE ASTM AND NFPA

REQUIREMENTS FOR FIRE RATING. REFER TO RELATED SPECIFICATION

SECTIONS FOR ADDITIONAL INFORMATION. INSTALLATION OF FIRE-STOPS

SHALL BE PERFORMED BY APPLICATOR/INSTALLER QUALIFIED AND TRAINED BY

THE MANUFACTURER. INSTALLATION SHALL BE PERFORMED IN STRICT

ACCORDANCE WITH MANUFACTURER'S DETAILED INSTALLATION PROCEDURES.

WALL MOUNTED DATA OUTLET - PROVIDE DOUBLE GANG BACKBOX W/ SINGLE

GANG DEVICE RING, 1 1/4" EMT CONDUIT W/ PULLSTRING TO ABOVE

ACCESSIBLE CEILING.

SYSTEMS SYMBOLS LEGEND

NEW CATEGORY 6 UTP CABLE - PLENUM RATED

TV TELEVISION/MONITOR WITH HDMI CONNECTION

LIFE SAFETY LEGEND

BUILDING SEPARATION

2 HOUR FIRE BARRIER

1 HOUR FIRE BARRIER

1/2 HOUR FIRE BARRIER

SMOKE BARRIER

SMOKE RESISTIVE CONSTRUCTION

CONSULTANTS:

Drawing Title

Approved:

Project Title:

Location:

Date: Checked: Drawn:

Drawing Number

Dwg. of

Building Number

Project Number

Office of Construction and Facilities Management

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

A

B

C

D

E

F

6 " o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t

209 SANDUSKY STREET

PITTSBURGH, PA 15212

PH: 412.287.7333

www.ae-works.com

AE WORKS PROJECT NUMBER:

ARCHITECTS/ENGINEERS:SEAL

Revision# Date

5/ 4/

:1

9:

P M

JEVZ MEDICAL CENTER -

ELECTRONIC SIGNAGE

503-17-103

BK SH

2907 Pleasant Valley Blvd, Altoona, PA 16602

01-E10B

BUILDING 1 - BASEMENT PLAN

05/07/2018 202 17033

BID DOCUMENTS

100% SUBMISSION

NOT TO SCALE

BUILDING 1 - BASEMENT FLOOR PLAN

DN

141C

141Q

141L

141B

141D

141N141E 141M 131B 131C

131D

131E

131F

141G

141A

E102 144A 145

145A 145B

S100

140C

140B

140A

134A

131A

130B

130A

131K

131J

131H

131G

129B

129A 129

125A

147C

148B

148C

148A

148A

E100

126A

118 119 194C

120A

118A

117A

116B

117B

199A

S102

198C

116A

116C

116D

115A

100C

100D

100A

100B

101A 101B

101D

S103

102A

102B

113B 113A 103

198D

197A 197

194B

151A

152A 157D 156A4

195B

157A

157J

194A

193G

193F

S101

193E

193D 193C

192G

188B

187186

185184183

188A

180A

157B

E101

176H

172G

172E

172D

172F

172I

172J

172C

172B

172A

S104

162A

160160A159159A 159B159C

158A

168A

161A

167 166

168B

157E

169C

169B

169A

161B

173174

175A

157C 177A

A117A

A117

A120 A119 A118

A123

A121

A125

A122A

A122B

A124 A126

A127 A129

A130 A131

A128

A132 A133

A135 A134

AS100

A114

A122

A136 A137

A116 A115

A112

A140A

A140

A139 A138E A138D A138C A138B

A141

A142

A138A

A138

A143A138F

A109A111

A110

A148 A147

A146 A138G

A145

A144

A105

A106

A107A A107

A106F A106A

A106BA106C

A106E A106D

A104

A102 A101B

A101A

A101 A101C

A101D

A100

A101E

156A1

156B 156

B102

B122A

B124

B123

B122

B120

B121

B10

B105 B103

B11 B11

B117

B113

B10

B107

B10

B10

B110

B111

B112

B11 B115 B114 C123

C124

C122 C121 C120 C11 C11 C117

C115

C13 C13

C137

C11

C114

C113

C135

C13

C125

C12 C12

C127

C110

C111

C112

C131

C134

C107

C132

C133

C103 C101

C102

C10

C10

C10

C105

C130

C104

C12

STOR.

LAUNDRY

VETERANCE

BEN.

VETERANCE

BEN.

FIRE

CLOS.

LAUNDRY

STORAGE VEST

CAT

SCAN

OFFICE

COMPUTER

RM

XRAY FILE

STOR

LAUNDRY

CORR

PATIENT

CLOTHING

STORAGE

ELEC

CLOS ELEV

SOCIALWOMENS EMPLOYEE

LOUNGE

CLINIC

OFFICE

STAIRS OFFICE

LITTER

AREA

MORGUE

AUTOPSY

TLT

TLT

XRAY

CAT

SCAN

STOR

CL

CL

CL

STORAGE

ULTRTA

SOUND

OFFICE

XRAY FILE

STOR

SOILED

UTIL

VIEWING

RADIOLOGY

DEXA OFFICE

XRAY XRAY

WAITING

WAITING

FXC

TLT

XRAY

CADIO LAB

EKG

LAB

OFF

LAB

OFFICE

ECHO

LAB

AUDIOLOGY

CLINIC

OFFICE

WAITING

ELEV

W

TLT

TLT

MENS

OFFICE

OFFICE

OFFICE

DIET CONSULT LOBBY

OP MANGER

OFF

RESPIRATORY

RESP.

EXAM/TREAT

RESP.

TOILET

CASHIER

TEL

CL

STAIRS

ELEC

RM

BILLING

OFF

EXAM/TREAT

CORR

EXAM/TREAT

EXAM/TREAT

WAITING

TOILET

TOILET

CLERK/HBA

CORR.

CLERK/HBA

CLERK/HBA

EQUIPMENT

RM

CORR.

NURSE

STA.

STOR.

STAIRS DIRTY

UT.

ENT./CONF.

CORR.

NURSING

CONSULT. SURG.

NURSE

EXAM

AUDIOLOGY

ELECTRIC

AUDIOLOGY

OFFICE

OFFICE

OFFICE PRIMARY

CARE

M

TLT

W

TLT

PR

CAREMED

DIR

CORR

CLERK

OFF

CHIEF

CLERK

OFF

CLERK

OFF

CLERK

OFF

CLERK

OFF

MULTI-PURPOSE

SECRETARY

PR. CARE

OFF

MED

PREP

VEST

MED

RECORDS

OFFICE

STAIRS

MED

RECORDS

EQUIP

CLERK CLERK

VEST

POLICEDIR.SECURITY

M.

TLT

W.

TLT

MECH

RM

MECH

RM

OUTPATIENT

LOBBY

ELEV

CHECK-IN

CLERK

CLERK

CLERK

CLERK

EXAM

RM

EXAM

RM

EXAM

RM

EXAM

RM

EXAM

RM

EXAM

RM

STAIRS

WAITING

ROOM

HAC

MECH

RM

ELEC.

CL.

DIR.OPSERV.

OFFICE EXAM

RM

CORR

B.P.SCR

RM TLT ELEC

CL

TEL

CL

TLT

EXAM

RM

TLT

VAULT

PHARMACY

EXAM

RM

EXAM

RM

EXAM

RM

CORR

EXAM

RM

EXAM

RMTLT

HAC

STOR.

OFFICE

CONF

RM

PHARMACY

OFF

MECH

SHAFT

MECH

SHAFT

WAITING

CORR

PAT

TLT

STAFF

TLT CONF/MTG

STAFF

RM.

CLERKS

MEDS

DISCHARGE

DISCHARGE

CLEAN

UTIL. SOILED

EX/TRT/OFF

EXAM

RM

EX

RM EX/TRT/OFF

CORR

EX

RM EX/TRT/OFF

EX/TRT/OFF EX/TRT/OFF

STAIRS

CORR

CORR

EX

RM

EX/TRT/OFF

EX/TRT/OFF

EX/TRT/OFF

EXAM

ELEC.CL.

HAC

PAT

TLT

BED

BED

BED

BED

DECONTAMINATION

VESTIBULE

EQUIP.

ALCOVE

CORR

CORR

NURSES

STATION

CORR

EXAM

RM

OXYGEN

ALCOVE

CLEAN

HOLD

MED

RM. NOUR

CLERKA

TRIAGE

REGISTRATION

CENTRAL

REGISTRATION

TLT/SHR

ON-CALL

ELIGIBILITY MACHINES

OPERATOR

STAFF

TLT

V.I.C

OFFICE

LOCKERS

CORR

CORR WAITING

WHEEL CHAIR

STOR.

WAITING

RECEP

AOD

VESTIBULE

ER

WAITING

CLINIC

CLOSET

RM

EXAM

RM

PRACTITIONER

NURSE

PRACTITIONER

EXAM

RM

INTERVIEW

H O U S E

K E E P

IN

G

TOIL

ROOMSCAN

CONTROL

RM

FREEZER

FREEZER

OXYGEN SMOKING

RM

OFFICE

LOCKER

ECHO

CAROTID

DOPLER

SUPERVISOR

CONSULT #

CONSULT #

RX

PICKUP

STORAGE

WORK

WAITING

CLEAN

JANITOR

ELECTRICAL

IT

BREAK

ROOM

ADL

OT

GYM

CORRIDOR

CLERK

UNI-SEX

OT

OFFICE

PT

OFFICE

HYDRO

THERAPY

PT GYM

STORAGE

TOILET

OT

EX/TRT/OFF

OT

EX/TRT/OFF

OT

EX/TRT/OFF

STAFF

TOILET

UNI-SEX

TOILET

SOILED

LAUNDRY

PT

EX/TRT/OFF VESTIBULE

PT

EX/TRT/OFF

PT

EX/TRT/OFF

CORRIDOR

PROST.

OFF.

CORRIDOR

PROSTHETICS STAFF

STAFF

BREAK

SUPERVISOR

PROSTHETICS

SPEECH

SOILED

MED SUPP

PRINT ROOM TOILET

PROST.

OFF.

PROST.

OFF.

PROST.

OFF.

PROST.

OFF.

PROST.

OFF.

ROOM

PROSTHETICS

OFFICE

FILING

ROOM

PATHOLOGIST

UTL.

ROOM

ROOM

STORAGE

CONFERENCE

ROOM

POWER

MOBILITY/AMPUTEE

CLINIC

CORRIDOR

CLEAN

SUPPLY/O2

STORAGE

CLINICAL

OFFICE

CLINICAL

OFFICE

EXAM

TREATMENT

ROOM

EMG/EXAM

ROOM

CORRIDOR

EXAM

TREATMENT

ROOM

EXAM

TREATMENT

ROOM

WAITING

ROOM VESTIBULE

LOBBY

SECRETARY/CLERK

ADMIN

OFFICER

PMRS

CHIEF

OFFICE

UNI-SEX

TOILET

JANITOR

ELECTRICAL

CLOSET

STAFF

TOILET

FUTURE MENTAL HYGIENE & CLINIC SPACE

40' X 72'

U P

T V

TV

TV T

V

TV

TV

TV

T

V TV

T V

A

D

A

H

E

E

A

E

A

A

E

D

N

E E

LWBC-31

IT CLOSET

E

E

EQP1-38E

E

E

E

E EQP2-6

E A E

E

N

I

J

I

N

N N

N

IT CLOSET

E

IT CLOSET E

EQP1-38

EE

E

EN

N E

E

LSP1B-5

LSP1B-5

A E

A E

G

G

N

N

N

C

E

F

A

KEYED NOTES

EXISTING MONITOR ACCEPTS HDMI CONNECTION.

EXISTING MONITOR NEEDS TO BE REPLACED.

NEW MONITOR LOCATION. INSTALL EXISTING MONITOR SALVAGED FROM OTHER

AREAS IN THE HOSPITAL SCHEDULED TO BE RE-USED AS PART OF THIS PROJECT. IF

THE BALANCE OF EXISTING MONITOR SALVAGED IS LESS THAN THE NEW MONITORS

REQUIRED, PROVIDE NEW MONITORS AS SPECIFIED. INSTALLATIONS ON FIRE RATED

WALLS SHALL BE PROVIDED WITH THE PROPER UL LISTED ASSEMBLY TO

MAINTAINING THE FIRE RATING OF THE STRUCTURE.

RE-PURPOSE EXISTING DATA OUTLET. RELOCATE BEHIND MONITOR AS REQUIRED.

NO EXISTING DATA OUTLET. PROVIDE NEW FROM THE IT CLOSET IDENTIFIED AND

INSTALL BEHIND THE MONITOR.

NO EXISTING POWER OUTLET. PROVIDE NEW HOSPITAL GRADE DUPLEX RECEPTACLE

AND CONNECT TO THE NEAREST RECEPTACLE CIRCUIT WITH (2) #12, (1) #12G IN 3/4"

CONDUIT.

CAREFULLY REMOVE EXISTING ,MONITOR, MOUNTING STRUCTURE, POWER AND TV

OUTLETS. SALVAGE EXISTING MONITOR AND MOUNTING STRUCTURE FOR RE-USE AS

PART OF THIS PROJECT. PATCH AND PAINT WALL TO MATCH EXISTING.

REPLACE EXISTING SIMPLEX OUTLET WITH DUPLEX.

PROVIDE NEW MODULAR PATCH PANEL AND MOUNT ON EXISTING 2-POST RACK.

PROVIDE NEW UTP CABLING AND TERMINATE ON EXISTING PANDUIT DP6 PLUS OPEN

PORT.

B

C

D

E

F

G

H

I

J

ELECTRICAL SYMBOLS LEGEND

DUPLEX RECEPTACLE IN A 4" SQUARE BOX WITH PLASTER RING (IN DRYWALL)

SINGLE GANG BOX IN MASONRY.

DOUBLE DUPLEX RECEPTACLE IN A 4" SQUARE BOX

NEW FIRE RATED SLEEVE. ALL PENETRATIONS OF WALLS AND/OR FLOORS

SHALL BE FIRE STOPPED IN ACCORDANCE WITH THE ASTM AND NFPA

REQUIREMENTS FOR FIRE RATING. REFER TO RELATED SPECIFICATION

SECTIONS FOR ADDITIONAL INFORMATION. INSTALLATION OF FIRE-STOPS

SHALL BE PERFORMED BY APPLICATOR/INSTALLER QUALIFIED AND TRAINED BY

THE MANUFACTURER. INSTALLATION SHALL BE PERFORMED IN STRICT

ACCORDANCE WITH MANUFACTURER'S DETAILED INSTALLATION PROCEDURES.

WALL MOUNTED DATA OUTLET - PROVIDE DOUBLE GANG BACKBOX W/ SINGLE

GANG DEVICE RING, 1 1/4" EMT CONDUIT W/ PULLSTRING TO ABOVE

ACCESSIBLE CEILING.

SYSTEMS SYMBOLS LEGEND

NEW CATEGORY 6 UTP CABLE - PLENUM RATED

TV TELEVISION/MONITOR WITH HDMI CONNECTION

LIFE SAFETY LEGEND

BUILDING SEPARATION

2 HOUR FIRE BARRIER

1 HOUR FIRE BARRIER

1/2 HOUR FIRE BARRIER

SMOKE BARRIER

SMOKE RESISTIVE CONSTRUCTION

CONSULTANTS:

Drawing Title

Approved:

Project Title:

Location:

Date: Checked: Drawn:

Drawing Number

Dwg. of

Building Number

Project Number

Office of Construction and Facilities Management

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

A

B

C

D

E

F

6 " o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t

209 SANDUSKY STREET

PITTSBURGH, PA 15212

PH: 412.287.7333

www.ae-works.com

AE WORKS PROJECT NUMBER:

ARCHITECTS/ENGINEERS:SEAL

Revision# Date

5/ 4/

:1

9:

P M

JEVZ MEDICAL CENTER -

ELECTRONIC SIGNAGE

503-17-103

BK SH

2907 Pleasant Valley Blvd, Altoona, PA 16602

01-E101

BUILDING 1 - FIRST FLOOR PLAN

05/07/2018 203 17033

BID DOCUMENTS

100% SUBMISSION

NOT TO SCALE

BUILDING 1 - FIRST FLOOR PLAN

UP

UP

UP

UP

232A

232C

236A

234B

234A

229A

S201

236E202

240C

240B

274B

240A

216A

205A

S203

203A

240D

274A

S202

E200

271272 273 268

241A

243A 243B 244A

251251A

252A

253A 253B 253C 257

253D

253E 253F

253G

256B

A

255A

S204

254B

254A

253V 253U

253L253M

253K

T

253S

253R

N253Q

253P

253J

253H

E201

S201

265266

259A

258A

258B

261A

261C

261B

262A

262B 262C

274C

274D

274E

274F

275A

275B

275C

274G

274H276

273A

A

STOR

STOR

CORR

STOR FOOD

FREEZER

FREEZER

CORR

CLEANING

SUPPLIES

STOR

STOR

TRASH

RM

STORE

FREEZER

TLT

INGREDIENT

STORAGE

BREAK

ROOM

STAIRS

POT/PAN WASH

RM

FREEZER

SOILEDELEV

KITCHEN

DISH

ROOM

DIETICIAN

OFFICE

CHIEF

NUTRITION

CORR

OFFICE

DIET

COMM

VOLUNTEER

STOR

DAYROOM

CHIEF VOL

SERV

SECRY VOL

SERV

CATHOLIC

SOC WK

OFFICE

OFFICE

OFFICE

SACRISTY

CHAPLIN

OFFICE

HAC

STAIRS

PROSTHET

OFFICE

STOR

CHAPEL

FXC

ELEC

CLO

EDUCATION

CLASSROOM

LOUNGE

CHAPLIN

CORR

STAIRS

ELEV

VOL.

KIT

HAC

ELEC.

CL

TELE

CL

OFFICE

RECEPTIONIST

WAITING

ROOM DARK

RM

XRAY XRAY STOR

STOR

EXAM

ROOM

STOR

STERILIZER

RM

EXAM/TR

D E N T A L C A S T

R M

EXAM/TREXAM/TR

ORAL

SURG

STORAGE

CHEMISTRY

LAB

SECRETARY

SECRY SPEECH

PATH

WAITING

ROOM

TLT

TLT

LIBRARY

LIBR.

OFFICE

L

IB

R W O R K

R M

ELEC

CLO

TEL

STAIRS

LAB CONF

RM

TLT

TLT

HISTOLOGY

MICROBOLOGY

SUPPLY

STORHAC

STORAGE

L A B

O F F

IC

E

MICROBIOLOGY

STOR

S P E C

IA

L

C H E M

IS

T R

YEQUIP

RM

WASH

RM

BLOOD BANK

PHLOBOTOMY

ELEV

PHYSICAL

THERAPY

TUB

ROOM

OCCUPATIONAL

THERAPY

STAIRS

STORWOMENS

MENS

PHYS TH

OFFICE

OFFICE

OFFICE

STOR

STORAGE

TLT

STOR

PT

OFFICE

LOBBY

VEST

CORR

CORR

CORR

CORR

CORR

CORR

CORR

CORR

CORRCORR

TEL

ROOF OF FIRST

FLOOR

WAREHOUSE

OFFICE

HISTOLOGY

MICROBIOLOGY

OFFICE

S T O R A G E x x x x x x x x x xxxxxxx x x x x x x x x x x x x x x x x x x x x x x x x x x x

BUILDING 1 - FLOOR

TV

TV

T V

T V

A

A

E

E

E E N

LP2D-22

LP2A2-3

E

E N

I

IT CLOSET

N

N

N

C

E

F

N

N

N

C

E

F

K

A

KEYED NOTES

EXISTING MONITOR ACCEPTS HDMI CONNECTION.

EXISTING MONITOR NEEDS TO BE REPLACED.

NEW MONITOR LOCATION. INSTALL EXISTING MONITOR SALVAGED FROM OTHER

AREAS IN THE HOSPITAL SCHEDULED TO BE RE-USED AS PART OF THIS PROJECT. IF

THE BALANCE OF EXISTING MONITOR SALVAGED IS LESS THAN THE NEW MONITORS

REQUIRED, PROVIDE NEW MONITORS AS SPECIFIED. INSTALLATIONS ON FIRE RATED

WALLS SHALL BE PROVIDED WITH THE PROPER UL LISTED ASSEMBLY TO

MAINTAINING THE FIRE RATING OF THE STRUCTURE.

RE-PURPOSE EXISTING DATA OUTLET. RELOCATE BEHIND MONITOR AS REQUIRED.

NO EXISTING DATA OUTLET. PROVIDE NEW FROM THE IT CLOSET IDENTIFIED AND

INSTALL BEHIND THE MONITOR.

NO EXISTING POWER OUTLET. PROVIDE NEW HOSPITAL GRADE DUPLEX RECEPTACLE

AND CONNECT TO THE NEAREST RECEPTACLE CIRCUIT WITH (2) #12, (1) #12G IN 3/4"

CONDUIT.

CAREFULLY REMOVE EXISTING ,MONITOR, MOUNTING STRUCTURE, POWER AND TV

OUTLETS. SALVAGE EXISTING MONITOR AND MOUNTING STRUCTURE FOR RE-USE AS

PART OF THIS PROJECT. PATCH AND PAINT WALL TO MATCH EXISTING.

REPLACE EXISTING SIMPLEX OUTLET WITH DUPLEX.

PROVIDE NEW MODULAR PATCH PANEL AND MOUNT ON EXISTING 2-POST RACK.

PROVIDE NEW UTP CABLING AND TERMINATE ON EXISTING PANDUIT DP6 PLUS OPEN

PORT.

B

C

D

E

F

G

H

I

J

ELECTRICAL SYMBOLS LEGEND

DUPLEX RECEPTACLE IN A 4" SQUARE BOX WITH PLASTER RING (IN DRYWALL)

SINGLE GANG BOX IN MASONRY.

DOUBLE DUPLEX RECEPTACLE IN A 4" SQUARE BOX

NEW FIRE RATED SLEEVE. ALL PENETRATIONS OF WALLS AND/OR FLOORS

SHALL BE FIRE STOPPED IN ACCORDANCE WITH THE ASTM AND NFPA

REQUIREMENTS FOR FIRE RATING. REFER TO RELATED SPECIFICATION

SECTIONS FOR ADDITIONAL INFORMATION. INSTALLATION OF FIRE-STOPS

SHALL BE PERFORMED BY APPLICATOR/INSTALLER QUALIFIED AND TRAINED BY

THE MANUFACTURER. INSTALLATION SHALL BE PERFORMED IN STRICT

ACCORDANCE WITH MANUFACTURER'S DETAILED INSTALLATION PROCEDURES.

WALL MOUNTED DATA OUTLET - PROVIDE DOUBLE GANG BACKBOX W/ SINGLE

GANG DEVICE RING, 1 1/4" EMT CONDUIT W/ PULLSTRING TO ABOVE

ACCESSIBLE CEILING.

SYSTEMS SYMBOLS LEGEND

NEW CATEGORY 6 UTP CABLE - PLENUM RATED

TV TELEVISION/MONITOR WITH HDMI CONNECTION

LIFE SAFETY LEGEND

BUILDING SEPARATION

2 HOUR FIRE BARRIER

1 HOUR FIRE BARRIER

1/2 HOUR FIRE BARRIER

SMOKE BARRIER

SMOKE RESISTIVE CONSTRUCTION

CONSULTANTS:

Drawing Title

Approved:

Project Title:

Location:

Date: Checked: Drawn:

Drawing Number

Dwg. of

Building Number

Project Number

Office of Construction and Facilities Management

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

A

B

C

D

E

F

6 " o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t

209 SANDUSKY STREET

PITTSBURGH, PA 15212

PH: 412.287.7333

www.ae-works.com

AE WORKS PROJECT NUMBER:

ARCHITECTS/ENGINEERS:SEAL

Revision# Date

5/ 4/

:1

9:

P M

JEVZ MEDICAL CENTER -

ELECTRONIC SIGNAGE

503-17-103

BK SH

2907 Pleasant Valley Blvd, Altoona, PA 16602

01-E102

BUILDING 1 - SECOND FLOOR PLAN

05/07/2018 204 17033

BID DOCUMENTS

100% SUBMISSION

NOT TO SCALE

BUILDING 1 - SECOND FLOOR PLAN

Fountain

Fountain

S304

S301

E301

364365

370B

366B

356B

357B

359358

357J

359H

357-3 357-2 357-1

357D

357A

356-5

356-4

356-3

356-2

352-1

356-6

368A

366C

350A

352A

366D

245C 345B

345A

308A

309A

377C

369A 369B

370A

377A

376C

376B

375B

375C

376A375A

366E

377B

381A

382B

342B 342A

342C

319321

325326

S300

S302

E300

313A

314A

315A

A

302A

305A

306B

S303

307A

305C

306A

303A

302B

302A

319A321A

331 333 334

325B

329A

333A

334A

386A

386B

386C

386D

386E

386F

386G

357C

366A

332A

383A

342D

335A

335B

300A

305B

306A

302B

306C

STAIRS

STAIRS

ELEV

ANESHESIA

WORKROOM

TEL

ELEC

ENGSTOR

STOR

SCRUB

RM

OPER RM

OR

OPER RM

OR

XRAY

OR

CYSTOSCOPY

STOR

ICU

HAC

TLT

ICU

C L

LI

N

IC

U

MEDICATION

ROOM

UTILITY

ROOM

NURSE

STA

NURSE STA

OR

LOCKER

HACSTORAGE

ISOLATION

ROOM

ISOLATION

RECOVERY

OR

RECOVERY

OR

RECOVERY

OR

TLT

PATIENT

RECEIVING

SLD UT

OR

1-BED RM

ICU

1-BED RM

ICU

1-BED RM

ICU

1-BED RM

ICU

1-BED RM

ICU

1-BED RM

ICU

MEDICAL

SVC

STER RM

OR

SCRUB

RM

SHOWER

ISOLATION

NRS

SUPR

CONSUT

RM

STORAGE

VISITORS

LAUNGE

TLT STAFF

LOUNGE

SCRUB

RM

RM

ICU RM

ICU

TLT

ICU

TLT

TLT

STORAGE

SPD

STOR

OR OR

STER. RM.

OR

STORAGE

SPD

SH

LOUNGE

OFFICE

SH

M

TLT

F

TLT

HEAD NRS

OF

PAT RCVG

OR

S L D

U T

O R

CONF RM

OR

STORAGE

SPD

STERILIZATION RM

SPD

WAREHOUSE

SPD

STER RM

SPDHAC

DECONT AREA

SPD

STOR

W. DRESS

TLT

M.

DRESS

CHIEF

SPD

SEC SURG

SVC

OFFICE

SURG CHIEF SURG

SVC

CHIEF MED

SVC

HOPETEL

HOPETEL

HAC

WAITING

ROOM

NURSING

NURSING

WAITING

ROOM

MED

REC

NRS

STA

NURSINGEXAM

RMSURGERY

EYE

GUHAC

STAIRS

MECHANICAL

ROOM

STOR

TLT

ELEC

CLO

TEL

CLO

STAIRS

ELEV

TLT

TLT NRS

SVC

NURSES

STATION

DAY

ROOM

CO

ORDINATOR

PODIATRY

UTILITY

RM

NURSING

GU

SURGERY

STAIRS

DR

RM

BATH/SH

DR

RM

DRESS

RM

TLT

DRESS

RM

SD

LINEN

TLTTLT

WAITING

ROOM

NEURO

EXAM

NEURO

NURSING

EXAM

RM

EXAM

RM

FXC

CLOSET

EYE

TECH

NURSING

TLT

NURSING

CORR

LOBBY

CORR

CORR

CORR

CORR

CORR

CORR

IV

STOR

HAC

ELEV.

EQUIP

TLT

TEL

CLO

OFFICE

CLERICAL

STAFF

GU

SURGICAL

ROOM

ROOM

CHECK

OUT

SPECIALITY

SERVICE

PODIATRY

MED.RM

SVC

RM

SPD

RM

SPD

F.

DRESS

M. DRESS

DRK RM

FEMALE SECRETARY

BUILDING 1 - FLOOR

TV

TV

T V

T V

A

E

E

A

N E E

E N E

J

IT CLOSET

N

N

N

C

E

F

N

N

N C

E

F

A

KEYED NOTES

EXISTING MONITOR ACCEPTS HDMI CONNECTION.

EXISTING MONITOR NEEDS TO BE REPLACED.

NEW MONITOR LOCATION. INSTALL EXISTING MONITOR SALVAGED FROM OTHER

AREAS IN THE HOSPITAL SCHEDULED TO BE RE-USED AS PART OF THIS PROJECT. IF

THE BALANCE OF EXISTING MONITOR SALVAGED IS LESS THAN THE NEW MONITORS

REQUIRED, PROVIDE NEW MONITORS AS SPECIFIED. INSTALLATIONS ON FIRE RATED

WALLS SHALL BE PROVIDED WITH THE PROPER UL LISTED ASSEMBLY TO

MAINTAINING THE FIRE RATING OF THE STRUCTURE.

RE-PURPOSE EXISTING DATA OUTLET. RELOCATE BEHIND MONITOR AS REQUIRED.

NO EXISTING DATA OUTLET. PROVIDE NEW FROM THE IT CLOSET IDENTIFIED AND

INSTALL BEHIND THE MONITOR.

NO EXISTING POWER OUTLET. PROVIDE NEW HOSPITAL GRADE DUPLEX RECEPTACLE

AND CONNECT TO THE NEAREST RECEPTACLE CIRCUIT WITH (2) #12, (1) #12G IN 3/4"

CONDUIT.

CAREFULLY REMOVE EXISTING ,MONITOR, MOUNTING STRUCTURE, POWER AND TV

OUTLETS. SALVAGE EXISTING MONITOR AND MOUNTING STRUCTURE FOR RE-USE AS

PART OF THIS PROJECT. PATCH AND PAINT WALL TO MATCH EXISTING.

REPLACE EXISTING SIMPLEX OUTLET WITH DUPLEX.

PROVIDE NEW MODULAR PATCH PANEL AND MOUNT ON EXISTING 2-POST RACK.

PROVIDE NEW UTP CABLING AND TERMINATE ON EXISTING PANDUIT DP6 PLUS OPEN

PORT.

B

C

D

E

F

G

H

I

J

ELECTRICAL SYMBOLS LEGEND

DUPLEX RECEPTACLE IN A 4" SQUARE BOX WITH PLASTER RING (IN DRYWALL)

SINGLE GANG BOX IN MASONRY.

DOUBLE DUPLEX RECEPTACLE IN A 4" SQUARE BOX

NEW FIRE RATED SLEEVE. ALL PENETRATIONS OF WALLS AND/OR FLOORS

SHALL BE FIRE STOPPED IN ACCORDANCE WITH THE ASTM AND NFPA

REQUIREMENTS FOR FIRE RATING. REFER TO RELATED SPECIFICATION

SECTIONS FOR ADDITIONAL INFORMATION. INSTALLATION OF FIRE-STOPS

SHALL BE PERFORMED BY APPLICATOR/INSTALLER QUALIFIED AND TRAINED BY

THE MANUFACTURER. INSTALLATION SHALL BE PERFORMED IN STRICT

ACCORDANCE WITH MANUFACTURER'S DETAILED INSTALLATION PROCEDURES.

WALL MOUNTED DATA OUTLET - PROVIDE DOUBLE GANG BACKBOX W/ SINGLE

GANG DEVICE RING, 1 1/4" EMT CONDUIT W/ PULLSTRING TO ABOVE

ACCESSIBLE CEILING.

SYSTEMS SYMBOLS LEGEND

NEW CATEGORY 6 UTP CABLE - PLENUM RATED

TV TELEVISION/MONITOR WITH HDMI CONNECTION

LIFE SAFETY LEGEND

BUILDING SEPARATION

2 HOUR FIRE BARRIER

1 HOUR FIRE BARRIER

1/2 HOUR FIRE BARRIER

SMOKE BARRIER

SMOKE RESISTIVE CONSTRUCTION

CONSULTANTS:

Drawing Title

Approved:

Project Title:

Location:

Date: Checked: Drawn:

Drawing Number

Dwg. of

Building Number

Project Number

Office of Construction and Facilities Management

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

A

B

C

D

E

F

6 " o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t

209 SANDUSKY STREET

PITTSBURGH, PA 15212

PH: 412.287.7333

www.ae-works.com

AE WORKS PROJECT NUMBER:

ARCHITECTS/ENGINEERS:SEAL

Revision# Date

5/ 4/

:1

9:

P M

JEVZ MEDICAL CENTER -

ELECTRONIC SIGNAGE

503-17-103

BK SH

2907 Pleasant Valley Blvd, Altoona, PA 16602

01-E103

BUILDING 1 - THIRD FLOOR PLAN

05/07/2018 205 17033

BID DOCUMENTS

100% SUBMISSION

NOT TO SCALE

BUILDING 1 - THIRD FLOOR PLAN

S400

429 430 431 432

415A

427 428

S404

434I

S401

434J

443444 445447

S402

444A

400401

E400

405406

412A

413A

444A 444B

444C414

418417

442442ASTAIRS

4-BED RM NRS

SVC

4-BED RM NRS

SVC

TLTTLT

1-BED RM NRS

SVC

NRS.

STATION

STAIRS

PENTHOUSE MECH RM ENGR

SERVICE

THERAPY

RECREATION

SLD

UT

STAIRS

HAC

LOUNGE

CONF

RM

CL

LINEN

MED

PREP

STOR

STAIRS

TEL.

CL

CORR

OFFICEOFFICE

OFFICE

TLT

ELEV

STOR

STOR

NOUR

KIT

LINEN

ROOM

BREAK

ROOM

UTL.

ROOM

STO

ELEC

ROOM

TLT

1-BED RM NRS

SVC

ISOLA

ISOLA

CORR CORR

SECR

CORRFXC

FXC

CART

TEL.

CL

STOR

NRS.

STATION

CRASH

OXY

T

V

T V

A

E

N

N

N

C

E

F

IT CLOSET

J

E

N

E

ELECTRICAL SYMBOLS LEGEND

DUPLEX RECEPTACLE IN A 4" SQUARE BOX WITH PLASTER RING (IN DRYWALL)

SINGLE GANG BOX IN MASONRY.

DOUBLE DUPLEX RECEPTACLE IN A 4" SQUARE BOX

NEW FIRE RATED SLEEVE. ALL PENETRATIONS OF WALLS AND/OR FLOORS

SHALL BE FIRE STOPPED IN ACCORDANCE WITH THE ASTM AND NFPA

REQUIREMENTS FOR FIRE RATING. REFER TO RELATED SPECIFICATION

SECTIONS FOR ADDITIONAL INFORMATION. INSTALLATION OF FIRE-STOPS

SHALL BE PERFORMED BY APPLICATOR/INSTALLER QUALIFIED AND TRAINED BY

THE MANUFACTURER. INSTALLATION SHALL BE PERFORMED IN STRICT

ACCORDANCE WITH MANUFACTURER'S DETAILED INSTALLATION PROCEDURES.

WALL MOUNTED DATA OUTLET - PROVIDE DOUBLE GANG BACKBOX W/ SINGLE

GANG DEVICE RING, 1 1/4" EMT CONDUIT W/ PULLSTRING TO ABOVE

ACCESSIBLE CEILING.

SYSTEMS SYMBOLS LEGEND

NEW CATEGORY 6 UTP CABLE - PLENUM RATED

TV TELEVISION/MONITOR WITH HDMI CONNECTION

LIFE SAFETY LEGEND

BUILDING SEPARATION

2 HOUR FIRE BARRIER

1 HOUR FIRE BARRIER

1/2 HOUR FIRE BARRIER

SMOKE BARRIER

SMOKE RESISTIVE CONSTRUCTION

A

KEYED NOTES

EXISTING MONITOR ACCEPTS HDMI CONNECTION.

EXISTING MONITOR NEEDS TO BE REPLACED.

NEW MONITOR LOCATION. INSTALL EXISTING MONITOR SALVAGED FROM OTHER

AREAS IN THE HOSPITAL SCHEDULED TO BE RE-USED AS PART OF THIS PROJECT. IF

THE BALANCE OF EXISTING MONITOR SALVAGED IS LESS THAN THE NEW MONITORS

REQUIRED, PROVIDE NEW MONITORS AS SPECIFIED. INSTALLATIONS ON FIRE RATED

WALLS SHALL BE PROVIDED WITH THE PROPER UL LISTED ASSEMBLY TO

MAINTAINING THE FIRE RATING OF THE STRUCTURE.

RE-PURPOSE EXISTING DATA OUTLET. RELOCATE BEHIND MONITOR AS REQUIRED.

NO EXISTING DATA OUTLET. PROVIDE NEW FROM THE IT CLOSET IDENTIFIED AND

INSTALL BEHIND THE MONITOR.

NO EXISTING POWER OUTLET. PROVIDE NEW HOSPITAL GRADE DUPLEX RECEPTACLE

AND CONNECT TO THE NEAREST RECEPTACLE CIRCUIT WITH (2) #12, (1) #12G IN 3/4"

CONDUIT.

CAREFULLY REMOVE EXISTING ,MONITOR, MOUNTING STRUCTURE, POWER AND TV

OUTLETS. SALVAGE EXISTING MONITOR AND MOUNTING STRUCTURE FOR RE-USE AS

PART OF THIS PROJECT. PATCH AND PAINT WALL TO MATCH EXISTING.

REPLACE EXISTING SIMPLEX OUTLET WITH DUPLEX.

PROVIDE NEW MODULAR PATCH PANEL AND MOUNT ON EXISTING 2-POST RACK.

PROVIDE NEW UTP CABLING AND TERMINATE ON EXISTING PANDUIT DP6 PLUS OPEN

PORT.

B

C

D

E

F

G

H

I

J

CONSULTANTS:

Drawing Title

Approved:

Project Title:

Location:

Date: Checked: Drawn:

Drawing Number

Dwg. of

Building Number

Project Number

Office of Construction and Facilities Management

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

A

B

C

D

E

F

6 " o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t

209 SANDUSKY STREET

PITTSBURGH, PA 15212

PH: 412.287.7333

www.ae-works.com

AE WORKS PROJECT NUMBER:

ARCHITECTS/ENGINEERS:SEAL

Revision# Date

5/ 4/

:1

9:

P M

JEVZ MEDICAL CENTER -

ELECTRONIC SIGNAGE

503-17-103

BK SH

2907 Pleasant Valley Blvd, Altoona, PA 16602

01-E104

BUILDING 1 - FOURTH FLOOR PLAN

05/07/2018 206 17033

BID DOCUMENTS

100% SUBMISSION

NOT TO SCALE

BUILDING 1 - FOURTH FLOOR PLAN

S500

513512A

511 510

509A

504 503 502 553A

S502

552A

548A 547A 547

546 545

S501

542A 542

541A

539A

538537

537B

536A535A

535534

534A533A

516515514

513A 514A

2 BED PATIENT

ROOM

STAIRS

2 BED PATIENT

ROOM

PATIENT

BATHROOM

JANITOR OFFICE

PATIENT

BATHROOM

2 BED PATIENT

ROOM

ACTIVITY

BATHROOM

ELECTRICAL

CLOSET

SOILED

UTILITY UNI-SEX

TOILET

MEDS/OMNI

CELL

NOURISH

ROOM

LINEN

ROOM

ELECTRICAL

CLOSET

CORRIDOR

HEARTH

ROOM

STAIR

TEL

CLOSET

WHEEL

CHAIR

STORAGE

1 BED PATIENT

ROOMCONFERENCEBREAK

ROOM

UNI-SEX

TOILET

PATIENT

BATHROOM

PATIENT

BATHROOM

1 BED PATIENT

ROOM PATIENT

BATHROOM

TUB

ROOM/BARBER

LAUNDRY

ROOM

STAIR

EX

SOILED

UTILITY

PATIENT

BATHROOM

1 BED PATIENT

ROOM

1 BED PATIENT

ROOM

PATIENT

BATHROOM

STORAGENRC

SVC

PATIENT

BATHROOM

1 BED PATIENT

ROOM

PATIENT

BATHROOM

1 BED PATIENT

ROOMDAY ROOM

ELECTRICAL

CLOSET

2 BED PATIENT

ROOM

PATIENT

BATHROOM

PATIENT

BATHROOM

2 BED PATIENT

ROOM

2 BED PATIENT

ROOM

PATIENT

BATHROOM

PATIENT

BATHROOM

1 BED PATIENT

ROOM

LPN

ALCOVE

HEARTH

ROOMPATIENT

PANTRY

DINING

ROOM

2 BED PATIENT

ROOM

PATIENT

BATHROOM

PATIENT

BATHROOM

T V

T V

A

E

N

E

E

LWSF-14

J

IT CLOSETN

N

N

C

E

F

A

KEYED NOTES

EXISTING MONITOR ACCEPTS HDMI CONNECTION.

EXISTING MONITOR NEEDS TO BE REPLACED.

NEW MONITOR LOCATION. INSTALL EXISTING MONITOR SALVAGED FROM OTHER

AREAS IN THE HOSPITAL SCHEDULED TO BE RE-USED AS PART OF THIS PROJECT. IF

THE BALANCE OF EXISTING MONITOR SALVAGED IS LESS THAN THE NEW MONITORS

REQUIRED, PROVIDE NEW MONITORS AS SPECIFIED. INSTALLATIONS ON FIRE RATED

WALLS SHALL BE PROVIDED WITH THE PROPER UL LISTED ASSEMBLY TO

MAINTAINING THE FIRE RATING OF THE STRUCTURE.

R…