36C24418B0592-007.pdf
PDF 1 MB Posted
- Solicitation number
- 36C24418B0592
About this file
36C24418B0592 Attachment - Drawings - M101.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24418B0592-0001000.docx | DOCX document | |
| 36C24418B0592-0001001.pdf | ||
| 36C24418B0592-0001002.pdf | ||
| 36C24418B0592-018.docx | DOCX document | |
| 36C24418B0592-020.doc | DOC document | |
| 36C24418B0592-022.docx | DOCX document | |
| 36C24418B0592-021.docx | DOCX document | |
| 36C24418B0592-023.docx | DOCX document | |
| 36C24418B0592-005.pdf | ||
| 36C24418B0592-025.docx | DOCX document | |
| 36C24418B0592-010.docx | DOCX document | |
| 36C24418B0592-004.docx | DOCX document | |
| 36C24418B0592-026.docx | DOCX document | |
| 36C24418B0592-014.docx | DOCX document | |
| 36C24418B0592-016.docx | DOCX document | |
| 36C24418B0592-024.docx | DOCX document | |
| 36C24418B0592-009.doc | DOC document | |
| 36C24418B0592-012.docx | DOCX document | |
| 36C24418B0592-013.docx | DOCX document | |
| 36C24418B0592-015.docx | DOCX document | |
| 36C24418B0592-011.doc | DOC document | |
| 36C24418B0592-006.pdf | ||
| 36C24418B0592-008.pdf | ||
| 36C24418B0592-017.docx | DOCX document | |
| 36C24418B0592-019.doc | DOC document | |
| 36C24418B0592-027.docx | DOCX document | |
| 36C24418B0592-000.docx | DOCX document |
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
8Ø
8Ø
Ø
10Ø
KEYNOTE:
10Ø TOTALLY WELDED STAINLESS STEEL EXHAUST DUCT
EXPOSED IN ROOM. EXTEND DUCTWORK THRU THE WALL
INTO SHAFT AND EXTEND UP TO PENTHOUSE, 600 CFM.
THE DUCTWORK SHALL BE ASTM A 480 AND A 276, TYPES
304L OR 316L 18 GAUGE STAINLESS STEEL. THE
DUCTWORK WITHIN THE SHAFT WILL USE DUCTMATE
SPIRALMATE WITH SEAL CLASS 'A'.
F
4Ø TOTALLY WELDED STAINLESS STEEL EXHAUST DUCT
CONNECTION COLLAR WITH STAINLESS STEEL BLAST
GATE DAMPER, BALANCE TO 150 CFM PRIOR TO
CONNECTING TO CyTOF EQUIPMENT. FLEXIBLE
CONNECTION DUCTWORK TO BE PROVIDED WITH THE
EQUIPMENT.
6Ø TOTALLY WELDED STAINLESS STEEL EXHAUST DUCT
CONNECTION COLLAR WITH STAINLESS STEEL BLAST
GATE DAMPER, BALANCE TO 450 CFM PRIOR TO
CONNECTING TO CyTOF EQUIPMENT. FLEXIBLE
CONNECTION DUCTWORK TO BE PROVIDED WITH THE
EQUIPMENT.
CyTOF
EQUIPMENT
10Ø TOTALLY WELDED STAINLESS STEEL EXHAUST
DUCTWORK FROM BELOW AND UP TO PENTHOUSE
600 CFM
21-ACCU-A405-2
MOUNT ON EQUIPMENT
SUPPORT RAILS
PROVIDE REFRIGERANT PIPING SIZE AS RECOMMENDED BY
THE EQUIPMENT MANUFACTURE, ROUTE PIPING IN THE
MOST DIRECT ROUTING AS POSSIBLE, PROVIDE OFFSETS
AS NECESSARY. PROVIDE 1-1/2" FLEXIBLE ELASTOMERIC
INSULATION WITH VAPOR RETARDER AND UV PROTECTIVE
COATING.
21-SSAHU-A405-2
T
WALL MOUNTED THERMOSTAT TO CONTROL 21-SSAHU-A405-2
21-SSAHU-A405-2, WALL MOUNTED UNIT, FINAL LOCATION TO BE
DETERMINED IN THE FIELD AND AS DIRECTED BY VA FACILITIES
ENGINEERING GROUP.
EXHAUST FAN SCHEDULE
SYMBOL LOCATION SERVES
MINUMUM
CFM
RPM
STATIC
PRESSURE
DRIVE BHP
ELECT
CHAR
BASIS OF
DESIGN
ROOF
CyTOF
600 3754 2.9 BELT 1.46 3/60/480
GREENHECK-VEKTOR-H-10
NOTES:
1. PROVIDE GALVANIZED, 12" HIGH ROOF CURB FOR FAN SUPPORT, NO ROOF PENETRATION.
2. PROVIDE AIR PLENUM WITH SIDE INLET FLANGE.
3. COATED WITH LABCOAT, CONCRETE GRAY-RAL 7023, ENTIRE UNIT.
4. PROVIDE NEMA 3R DISCONNECT FOR OUTDOOR USE, MOUNTED AND WIRED.
5. 21-EF-A405-2 SHALL OPERATE WHENEVER THE ASSOCIATED CyTOF MACHINE IS IN USE.
THE CONTROL SEQUENCE SHALL BE THE SAME AS THE EXISTING CyTOF MACHINES
EXHAUST SYSTEM SEQUENCE.
HP
SPLIT SYSTEM AIR HANDLING UNIT SCHEDULE
SYMBOL
NOMINAL COOLING CAPACITY FAN ECM ELECT
BASIS OF DESIGN
CFM BTUH FLA CHAR
34,200
0.57 1-60-208V MITSUBISHI - PKA-A36KA4
SYMBOL
AIR COOLED CONDENSING UNIT SCHEDULE
CONDENSOR FAN ECM
QTY
0.75
FLA
TOTAL
QTY
RLA EA LRA EA
17.5
COMPRESSOR
ELECT CHAR SERVES BASIS OF DESIGN
MITSUBISHI - PUY-A36NHA4-BS
UNIT
WEIGHT
1-60-208V
NOTES:
1.
HERMETIC
TYPE
2.
3. PROVIDE LOW AMBIENT WIND BAFFLES ON CONDENSING UNIT FOR 0 °F DB OPERATION.
CAPACITIES BASED ON R-410A REFRIGERANT.
CAPACITIES BASED ON 95°F AMBIENT TEMPERATURE.
EACH
CFM
LBS
NOTES:
1.
2.
PROVIDE CONDENSATE PUMP WITH UNIT.
PROVIDE DRAIN PAN LEVEL SENSOR FOR UNIT SHUT OFF TO PREVENT DRAIN PAN OVERFLOW.
INDOOR UNIT SEQUENCE OF OPERATIONS:
ON/OFF CONTROL
· THE INDOOR UNITS CAN BE COMMANDED ON/OFF BY ITS INTERNAL CONTROLLER.
· IF THE INDOOR UNIT IS OFF, THE OUTDOOR UNIT SHALL TURN OFF.
SPACE TEMPERATURE CONTROL
· THE INDOOR UNIT SHALL MODULATE ITS INTERNAL LINEAR EXPANSION VALVE (LEV) TO MAINTAIN THE
TEMPERATURE SET POINT VIA THE INDOOR UNIT'S INTERNAL CONTROLS.
HEATING MODE
· N/A
COOLING MODE
· THE INDOOR UNIT SHALL MODULATE ITS LINEAR EXPANSION VALVE (LEV) TO MAINTAIN TEMPERATURE SET
POINT.
FAN CONTROL
· FAN SPEED SHALL BE ADJUSTABLE BY THE USER AT THE UNITS CONTROLLER.
21-SSAHU-A405-2
21-EF-A405-2
21-SSAHU-A405-2
21-EF-A405-2
(3) 20" DIAMETER ARGON TANKS AND REGULATOR
PROVIDED BY VA.
PROVIDE WALL MOUNTED BRACKET SYSTEM MADE OUT OF
UNISTRUT AND CHAIN. PROVIDE CLIPS TO ADD AND REMOVE
TANKS WITHOUT THE USE OF TOOLS.
PROVIDE 1/4" SEAMLESS TYPE K OR L (ASTM B88) COPPER TUBING.
FITTINGS USED FOR ASSEMBLY SHALL BE OF COPPER, BRASS OR
BRONZE SUITABLE FOR MAKING BRAZED CONNECTIONS.
ROUTE 1/4" ARGON LINES RACKED ALONG WALL VERTICALLY.
PROVIDE FINAL CONNECTION TO EQUIPMENT.
SYSTEM
CFM
NOZZLE
OV
EFFECTIVE STACK
HEIGHT FEET
18.34 th re e in ch es o ne fo ot on e an d o ne -h al f i nc h on e fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot on e-ha lf in ch o ne fo ot th re e-ei gh th s i nc h on e fo ot on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot
F E
D C
B A
Revisions
987654321
A
B
C
D
E
F
TME
04/26/2018
VAMC Philadelphia, Pennsylvania
1 2 3 4 5 6 7 8 9
Date
Approved: Service Director
Approved: Division Chief
Drawing Title
Location
DrawnCheckedBuilding Number
Project Title Date
Project No.
OfDwg.
DRAWING NO.
642-17-300H.F. LENZ COMPANY
IMAGING SYSTEM
4TH FLOORFOURTH & FIFTH
FLOOR PLANS
M101
NJB
FIFTH FLOOR PLAN
4' 8' 16'
SCALE: 1/8" = 1'-0"
FOURTH FLOOR PLAN
4' 8' 16'
SCALE: 1/8" = 1'-0"
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AUTOCLAVE
AutoCAD SHX Text
GLASSWARE
AutoCAD SHX Text
HAC
AutoCAD SHX Text A403
AutoCAD SHX Text
ELEVATOR
AutoCAD SHX Text A401
AutoCAD SHX Text
ELEVATOR LOBBY
AutoCAD SHX Text
TEL CLOSET
AutoCAD SHX Text A413
AutoCAD SHX Text
MEN
AutoCAD SHX Text
WOMEN
AutoCAD SHX Text A415
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
CLOSET
AutoCAD SHX Text
SHARED EQUIP STORAGE
AutoCAD SHX Text
LABORATORY
AutoCAD SHX Text F7
AutoCAD SHX Text F1
AutoCAD SHX Text A404
AutoCAD SHX Text F6
AutoCAD SHX Text A402A
AutoCAD SHX Text F1
AutoCAD SHX Text A402
AutoCAD SHX Text F2
AutoCAD SHX Text
STAIR
AutoCAD SHX Text
NO. 1
AutoCAD SHX Text
VESTIBULE
AutoCAD SHX Text A406
AutoCAD SHX Text F2
AutoCAD SHX Text
LABORATORY
AutoCAD SHX Text A410
AutoCAD SHX Text F2
AutoCAD SHX Text A405
AutoCAD SHX Text F1
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text A4C1
AutoCAD SHX Text F1
AutoCAD SHX Text A409
AutoCAD SHX Text F0
AutoCAD SHX Text F3
AutoCAD SHX Text F3
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text A4C2
AutoCAD SHX Text F1
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text A4C3
AutoCAD SHX Text F1
AutoCAD SHX Text
LABORATORY
AutoCAD SHX Text A414
AutoCAD SHX Text F2
AutoCAD SHX Text
DN
AutoCAD SHX Text
UP
AutoCAD SHX Text
TISSUE
AutoCAD SHX Text
CULTURE 1
AutoCAD SHX Text A406A
AutoCAD SHX Text F2
AutoCAD SHX Text
CULTURE 2
AutoCAD SHX Text
TISSUE
AutoCAD SHX Text A406B
AutoCAD SHX Text F2
AutoCAD SHX Text
DARK ROOM
AutoCAD SHX Text A406C
AutoCAD SHX Text F4
AutoCAD SHX Text
POST DOC
AutoCAD SHX Text A408
AutoCAD SHX Text F1
AutoCAD SHX Text
LABORATORY
AutoCAD SHX Text A418
AutoCAD SHX Text F2
AutoCAD SHX Text
FHC
AutoCAD SHX Text
FHC
AutoCAD SHX Text
TEMPERATURE RM
AutoCAD SHX Text F5
AutoCAD SHX Text
CONTROLLED
AutoCAD SHX Text A419
AutoCAD SHX Text
WARM RM
AutoCAD SHX Text F5
AutoCAD SHX Text A421
AutoCAD SHX Text 0%%d to 40%%dF
AutoCAD SHX Text 70%%dF to 120%%dF
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text A424
AutoCAD SHX Text F1
AutoCAD SHX Text A426
AutoCAD SHX Text F1
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text A423
AutoCAD SHX Text F1
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
MULTI-PURPOSE RM
AutoCAD SHX Text A425
AutoCAD SHX Text F1
AutoCAD SHX Text A422
AutoCAD SHX Text F1
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text C9
AutoCAD SHX Text E7
AutoCAD SHX Text D
AutoCAD SHX Text E8
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
%%USINGLE ROOM SPLIT AIR CONDITIONING SYSTEM SEQUENCE OF OPERATION
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text Johnstown, PA 15904
AutoCAD SHX Text
FAX: 814-269-9301
AutoCAD SHX Text www.hflenz.com
AutoCAD SHX Text Engineering
AutoCAD SHX Text 1407 Scalp Avenue
AutoCAD SHX Text Phone: 814-269-9300
AutoCAD SHX Text cadd@hflenz.com
AutoCAD SHX Text
AutoCAD SHX Text
| Sheets and Views |
| M101 |
File details come from the government source that posted it.