36C24418B0592-007.pdf

PDF 1 MB Posted

Attached to
642-18-3-584-0058 - Install Self-Imaging HVAC, Bldg 21
Solicitation number
36C24418B0592
Issued by

About this file

36C24418B0592 Attachment - Drawings - M101.pdf

View the file

Other files

File Type Posted
36C24418B0592-0001000.docx DOCX document
36C24418B0592-0001001.pdf PDF
36C24418B0592-0001002.pdf PDF
36C24418B0592-018.docx DOCX document
36C24418B0592-020.doc DOC document
36C24418B0592-022.docx DOCX document
36C24418B0592-021.docx DOCX document
36C24418B0592-023.docx DOCX document
36C24418B0592-005.pdf PDF
36C24418B0592-025.docx DOCX document
36C24418B0592-010.docx DOCX document
36C24418B0592-004.docx DOCX document
36C24418B0592-026.docx DOCX document
36C24418B0592-014.docx DOCX document
36C24418B0592-016.docx DOCX document
36C24418B0592-024.docx DOCX document
36C24418B0592-009.doc DOC document
36C24418B0592-012.docx DOCX document
36C24418B0592-013.docx DOCX document
36C24418B0592-015.docx DOCX document
36C24418B0592-011.doc DOC document
36C24418B0592-006.pdf PDF
36C24418B0592-008.pdf PDF
36C24418B0592-017.docx DOCX document
36C24418B0592-019.doc DOC document
36C24418B0592-027.docx DOCX document
36C24418B0592-000.docx DOCX document
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

8Ø

8Ø

Ø

10Ø

KEYNOTE:

10Ø TOTALLY WELDED STAINLESS STEEL EXHAUST DUCT

EXPOSED IN ROOM. EXTEND DUCTWORK THRU THE WALL

INTO SHAFT AND EXTEND UP TO PENTHOUSE, 600 CFM.

THE DUCTWORK SHALL BE ASTM A 480 AND A 276, TYPES

304L OR 316L 18 GAUGE STAINLESS STEEL. THE

DUCTWORK WITHIN THE SHAFT WILL USE DUCTMATE

SPIRALMATE WITH SEAL CLASS 'A'.

F

4Ø TOTALLY WELDED STAINLESS STEEL EXHAUST DUCT

CONNECTION COLLAR WITH STAINLESS STEEL BLAST

GATE DAMPER, BALANCE TO 150 CFM PRIOR TO

CONNECTING TO CyTOF EQUIPMENT. FLEXIBLE

CONNECTION DUCTWORK TO BE PROVIDED WITH THE

EQUIPMENT.

6Ø TOTALLY WELDED STAINLESS STEEL EXHAUST DUCT

CONNECTION COLLAR WITH STAINLESS STEEL BLAST

GATE DAMPER, BALANCE TO 450 CFM PRIOR TO

CONNECTING TO CyTOF EQUIPMENT. FLEXIBLE

CONNECTION DUCTWORK TO BE PROVIDED WITH THE

EQUIPMENT.

CyTOF

EQUIPMENT

10Ø TOTALLY WELDED STAINLESS STEEL EXHAUST

DUCTWORK FROM BELOW AND UP TO PENTHOUSE

600 CFM

21-ACCU-A405-2

MOUNT ON EQUIPMENT

SUPPORT RAILS

PROVIDE REFRIGERANT PIPING SIZE AS RECOMMENDED BY

THE EQUIPMENT MANUFACTURE, ROUTE PIPING IN THE

MOST DIRECT ROUTING AS POSSIBLE, PROVIDE OFFSETS

AS NECESSARY. PROVIDE 1-1/2" FLEXIBLE ELASTOMERIC

INSULATION WITH VAPOR RETARDER AND UV PROTECTIVE

COATING.

21-SSAHU-A405-2

T

WALL MOUNTED THERMOSTAT TO CONTROL 21-SSAHU-A405-2

21-SSAHU-A405-2, WALL MOUNTED UNIT, FINAL LOCATION TO BE

DETERMINED IN THE FIELD AND AS DIRECTED BY VA FACILITIES

ENGINEERING GROUP.

EXHAUST FAN SCHEDULE

SYMBOL LOCATION SERVES

MINUMUM

CFM

RPM

STATIC

PRESSURE

DRIVE BHP

ELECT

CHAR

BASIS OF

DESIGN

ROOF

CyTOF

600 3754 2.9 BELT 1.46 3/60/480

GREENHECK-VEKTOR-H-10

NOTES:

1. PROVIDE GALVANIZED, 12" HIGH ROOF CURB FOR FAN SUPPORT, NO ROOF PENETRATION.

2. PROVIDE AIR PLENUM WITH SIDE INLET FLANGE.

3. COATED WITH LABCOAT, CONCRETE GRAY-RAL 7023, ENTIRE UNIT.

4. PROVIDE NEMA 3R DISCONNECT FOR OUTDOOR USE, MOUNTED AND WIRED.

5. 21-EF-A405-2 SHALL OPERATE WHENEVER THE ASSOCIATED CyTOF MACHINE IS IN USE.

THE CONTROL SEQUENCE SHALL BE THE SAME AS THE EXISTING CyTOF MACHINES

EXHAUST SYSTEM SEQUENCE.

HP

SPLIT SYSTEM AIR HANDLING UNIT SCHEDULE

SYMBOL

NOMINAL COOLING CAPACITY FAN ECM ELECT

BASIS OF DESIGN

CFM BTUH FLA CHAR

34,200

0.57 1-60-208V MITSUBISHI - PKA-A36KA4

SYMBOL

AIR COOLED CONDENSING UNIT SCHEDULE

CONDENSOR FAN ECM

QTY

0.75

FLA

TOTAL

QTY

RLA EA LRA EA

17.5

COMPRESSOR

ELECT CHAR SERVES BASIS OF DESIGN

MITSUBISHI - PUY-A36NHA4-BS

UNIT

WEIGHT

1-60-208V

NOTES:

1.

HERMETIC

TYPE

2.

3. PROVIDE LOW AMBIENT WIND BAFFLES ON CONDENSING UNIT FOR 0 °F DB OPERATION.

CAPACITIES BASED ON R-410A REFRIGERANT.

CAPACITIES BASED ON 95°F AMBIENT TEMPERATURE.

EACH

CFM

LBS

NOTES:

1.

2.

PROVIDE CONDENSATE PUMP WITH UNIT.

PROVIDE DRAIN PAN LEVEL SENSOR FOR UNIT SHUT OFF TO PREVENT DRAIN PAN OVERFLOW.

INDOOR UNIT SEQUENCE OF OPERATIONS:

ON/OFF CONTROL

· THE INDOOR UNITS CAN BE COMMANDED ON/OFF BY ITS INTERNAL CONTROLLER.

· IF THE INDOOR UNIT IS OFF, THE OUTDOOR UNIT SHALL TURN OFF.

SPACE TEMPERATURE CONTROL

· THE INDOOR UNIT SHALL MODULATE ITS INTERNAL LINEAR EXPANSION VALVE (LEV) TO MAINTAIN THE

TEMPERATURE SET POINT VIA THE INDOOR UNIT'S INTERNAL CONTROLS.

HEATING MODE

· N/A

COOLING MODE

· THE INDOOR UNIT SHALL MODULATE ITS LINEAR EXPANSION VALVE (LEV) TO MAINTAIN TEMPERATURE SET

POINT.

FAN CONTROL

· FAN SPEED SHALL BE ADJUSTABLE BY THE USER AT THE UNITS CONTROLLER.

21-SSAHU-A405-2

21-EF-A405-2

21-SSAHU-A405-2

21-EF-A405-2

(3) 20" DIAMETER ARGON TANKS AND REGULATOR

PROVIDED BY VA.

PROVIDE WALL MOUNTED BRACKET SYSTEM MADE OUT OF

UNISTRUT AND CHAIN. PROVIDE CLIPS TO ADD AND REMOVE

TANKS WITHOUT THE USE OF TOOLS.

PROVIDE 1/4" SEAMLESS TYPE K OR L (ASTM B88) COPPER TUBING.

FITTINGS USED FOR ASSEMBLY SHALL BE OF COPPER, BRASS OR

BRONZE SUITABLE FOR MAKING BRAZED CONNECTIONS.

ROUTE 1/4" ARGON LINES RACKED ALONG WALL VERTICALLY.

PROVIDE FINAL CONNECTION TO EQUIPMENT.

SYSTEM

CFM

NOZZLE

OV

EFFECTIVE STACK

HEIGHT FEET

18.34 th re e in ch es o ne fo ot on e an d o ne -h al f i nc h on e fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot on e-ha lf in ch o ne fo ot th re e-ei gh th s i nc h on e fo ot on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot

F E

D C

B A

Revisions

987654321

A

B

C

D

E

F

TME

04/26/2018

VAMC Philadelphia, Pennsylvania

1 2 3 4 5 6 7 8 9

Date

Approved: Service Director

Approved: Division Chief

Drawing Title

Location

DrawnCheckedBuilding Number

Project Title Date

Project No.

OfDwg.

DRAWING NO.

642-17-300H.F. LENZ COMPANY

IMAGING SYSTEM

4TH FLOORFOURTH & FIFTH

FLOOR PLANS

M101

NJB

FIFTH FLOOR PLAN

4' 8' 16'

SCALE: 1/8" = 1'-0"

FOURTH FLOOR PLAN

4' 8' 16'

SCALE: 1/8" = 1'-0"

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

AUTOCLAVE

AutoCAD SHX Text

GLASSWARE

AutoCAD SHX Text

HAC

AutoCAD SHX Text A403

AutoCAD SHX Text

ELEVATOR

AutoCAD SHX Text A401

AutoCAD SHX Text

ELEVATOR LOBBY

AutoCAD SHX Text

TEL CLOSET

AutoCAD SHX Text A413

AutoCAD SHX Text

MEN

AutoCAD SHX Text

WOMEN

AutoCAD SHX Text A415

AutoCAD SHX Text

ELEC

AutoCAD SHX Text

CLOSET

AutoCAD SHX Text

SHARED EQUIP STORAGE

AutoCAD SHX Text

LABORATORY

AutoCAD SHX Text F7

AutoCAD SHX Text F1

AutoCAD SHX Text A404

AutoCAD SHX Text F6

AutoCAD SHX Text A402A

AutoCAD SHX Text F1

AutoCAD SHX Text A402

AutoCAD SHX Text F2

AutoCAD SHX Text

STAIR

AutoCAD SHX Text

NO. 1

AutoCAD SHX Text

VESTIBULE

AutoCAD SHX Text A406

AutoCAD SHX Text F2

AutoCAD SHX Text

LABORATORY

AutoCAD SHX Text A410

AutoCAD SHX Text F2

AutoCAD SHX Text A405

AutoCAD SHX Text F1

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text A4C1

AutoCAD SHX Text F1

AutoCAD SHX Text A409

AutoCAD SHX Text F0

AutoCAD SHX Text F3

AutoCAD SHX Text F3

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text A4C2

AutoCAD SHX Text F1

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text A4C3

AutoCAD SHX Text F1

AutoCAD SHX Text

LABORATORY

AutoCAD SHX Text A414

AutoCAD SHX Text F2

AutoCAD SHX Text

DN

AutoCAD SHX Text

UP

AutoCAD SHX Text

TISSUE

AutoCAD SHX Text

CULTURE 1

AutoCAD SHX Text A406A

AutoCAD SHX Text F2

AutoCAD SHX Text

CULTURE 2

AutoCAD SHX Text

TISSUE

AutoCAD SHX Text A406B

AutoCAD SHX Text F2

AutoCAD SHX Text

DARK ROOM

AutoCAD SHX Text A406C

AutoCAD SHX Text F4

AutoCAD SHX Text

POST DOC

AutoCAD SHX Text A408

AutoCAD SHX Text F1

AutoCAD SHX Text

LABORATORY

AutoCAD SHX Text A418

AutoCAD SHX Text F2

AutoCAD SHX Text

FHC

AutoCAD SHX Text

FHC

AutoCAD SHX Text

TEMPERATURE RM

AutoCAD SHX Text F5

AutoCAD SHX Text

CONTROLLED

AutoCAD SHX Text A419

AutoCAD SHX Text

WARM RM

AutoCAD SHX Text F5

AutoCAD SHX Text A421

AutoCAD SHX Text 0%%d to 40%%dF

AutoCAD SHX Text 70%%dF to 120%%dF

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text A424

AutoCAD SHX Text F1

AutoCAD SHX Text A426

AutoCAD SHX Text F1

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text A423

AutoCAD SHX Text F1

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

MULTI-PURPOSE RM

AutoCAD SHX Text A425

AutoCAD SHX Text F1

AutoCAD SHX Text A422

AutoCAD SHX Text F1

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text C9

AutoCAD SHX Text E7

AutoCAD SHX Text D

AutoCAD SHX Text E8

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

%%USINGLE ROOM SPLIT AIR CONDITIONING SYSTEM SEQUENCE OF OPERATION

AutoCAD SHX Text

NO SCALE

AutoCAD SHX Text Johnstown, PA 15904

AutoCAD SHX Text

FAX: 814-269-9301

AutoCAD SHX Text www.hflenz.com

AutoCAD SHX Text Engineering

AutoCAD SHX Text 1407 Scalp Avenue

AutoCAD SHX Text Phone: 814-269-9300

AutoCAD SHX Text cadd@hflenz.com

AutoCAD SHX Text

AutoCAD SHX Text

Sheets and Views
M101