36C24226Q0610.docx

DOCX document 28 KB Posted

Attached to
6515--EQUIPMENT - INFUSION DEVICE ANALYZER
Solicitation number
36C24226Q0610
Issued by

About this file

This is a Sources Sought Notice and Request for Information (RFI) issued by the Department of Veterans Affairs, Veterans Health Administration, Veterans Integrated Service Network 2 (VISN 02) Network Contracting Office, seeking qualified sources for an Infusion Device Analyzer for the Hudson Valley Healthcare System. The solicitation number is 36C24226Q0610, with responses due by May 21, 2026 at 4:00 PM Eastern Time. The product will be delivered to VA Hudson Valley Medical Center Castle Point Campus in Wappingers Falls, New York. The VA prefers domestically manufactured content where available.

The Infusion Device Analyzer must meet specific salient characteristics including integrated OneQA software for automated testing and documentation, multi-channel testing capability for up to four infusion pumps simultaneously, flow range of 0-3000 mL/h (steady) and 0-1500 mL/h (peristaltic) with accuracy of ±(1% + 0.005 mL/h), dimensions of approximately 95 mm × 210 mm × 260 mm weighing ~3.8 kg, and 19 V DC, 3 A power requirements. Responses must include company information, business size classification under NAICS code 334510 (Electromedical and Electrotherapeutic Apparatus Manufacturing, size standard 1,250 employees), manufacturer or distributor status, domestic versus foreign manufacturing origin, general pricing for market research purposes, and Sam.gov Unique Entity ID. This is not a binding solicitation but rather a market research tool; responses are not offers and cannot form contracts. Interested parties must submit separate responses to any future formal solicitation announcement.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sources Sought Notice Sources Sought Notice

SUBJECT*
EQUIPMENT - INFUSION DEVICE ANALYZER

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
10468-3904
SOLICITATION NUMBER*
36C24226Q0610
RESPONSE DATE/TIME/ZONE
05-21-2026 4:00PM EASTERN TIME, NEW YORK, USA
ARCHIVE
5 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N

SET-ASIDE

PRODUCT SERVICE CODE*
6515
NAICS CODE*
334510
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

Network Contracting Office 2 James J. Peters VA Medical Center 130 West Kingsbridge Road Bronx NY 10468-3904

POINT OF CONTACT*

Contract Specialist Sanchez Reid Sanchez.Reid@va.gov

PLACE OF PERFORMANCE

ADDRESS
Hudson Valley VA Medical Center Castle Point

Campus.

41 Castle Point Rd

Wappingers Falls NY

POSTAL CODE
12590
COUNTRY
USA

ADDITIONAL INFORMATION

AGENCY’S URL
https://www.va.gov
URL DESCRIPTION
VHA
AGENCY CONTACT’S EMAIL ADDRESS
Sanchez.Reid@va.gov

EMAIL DESCRIPTION

DESCRIPTION

THIS REQUEST FOR INFORMATION (RFI)/SOURCES SOUGHT IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION.

THE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 12.

DISCLAIMER

This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 12, responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.

SOURCES SOUGHT DESCRIPTION

This is NOT a solicitation announcement. This is a sources sought/RFI only. The purpose of this sources sought/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 334510- Electromedical and Electrotherapeutic Apparatus Manufacturing (size standard of 1,250 Employees). Responses to this sources sought will be used by the Government to make appropriate acquisition decisions. After review of the responses to this sources sought, a solicitation announcement may be published. Responses to this sources sought synopsis are not considered adequate responses for a solicitation announcement.

The Department of Veterans Affairs (VA), VISN 02 Network Contracting Office, is seeking sources that can provide Infusion Device Analyzer that at a minimum meet the following salient characteristics for the Hudson Valley Healthcare System:

To Be Delivered to:

VA Hudson Valley Medical Center Castle Point Campus 41 Castle Point Road Wappingers Falls, NY 12590

The VA has a preference for domestic (manufactured in the United States) content where available.

Salient Characteristics:

Workflow Automation: Integrated OneQA software for automated testing and documentation.

Multi-Channel Testing: Ability to test up to four infusion pumps simultaneously.

Accuracy & Resolution:

Flow range: 0–3000 mL/h (steady), 0–1500 mL/h (peristaltic).

Flow accuracy: ±(1% + 0.005 mL/h) at <500 mL/h; otherwise ±2%.

Volume range: 0–100,000 mL; resolution 0.001 mL.

Occlusion Testing: Peak pressure range -200 to +2600 mmHg; accuracy ±(1% + 5 mmHg).

Bolus & PCA Verification: Supports bolus flow and volume testing.

Compliance: Meets IEC60601-2-24 and IEC61010-1 standards.

User Interface: Large 10-inch touchscreen with intuitive controls.

Connectivity: USB-C for PC communication; wireless capability for field testing.

Data Storage: >10,000 measurements; ability to upload pictures and instructions.

Dimensions & Weight: Approx. 95 mm × 210 mm × 260 mm; weight ~3.8 kg.

Power: 19 V DC, 3 A.

The information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications.

If you are interested and are capable of providing the sought out supplies/services, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:

(1) Please indicate the size status and representations of your business, such as but not limited to: Service Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.)?

(2) Is your company considered small under the NAICS code identified under this RFI?

(3) Are you the manufacturer, distributor, or an equivalent solution to the items being referenced above?

(4) If you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of Contact and size status (if available).

(5) If you’re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?

(6) If you intend to sub contract any work on this contract, what portion of the total cost will be self-performed/will be performed by your organization? Please provide estimated detailed percentage breakdowns related to sub contracted work and completion of job.

(7) Does your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract number.

(8) If you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the items/solution you are providing information for available on your schedule/contract?

(9) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate any type of award.

(10) Please submit your capabilities in regard to the salient characteristics being provided and any information pertaining to “equal to items” to establish capabilities for planning purposes?

(11) Will the items you will be providing manufactured domestically in the United States or are they foreign manufactured items?

(12) Please review salient characteristics/statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A.

(13) Please provide your Sam.gov Unique Entity ID number.

Responses to this notice shall be submitted via email to Sanchez.Reid@va.gov. Telephone responses shall not be accepted. Responses must be received no later than May 21,2026 at 4:00PM EST. If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this sources sought. Responses to this sources sought notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation.

*= Required Field
Sources Sought Notice

Sources Sought Notice

File details come from the government source that posted it. Updated .