Sources Sought Notice Sources Sought Notice

SUBJECT*
Replacement 3M™ Scott™ Air-Pak X3 Pro SCBA and accessories for Northport VAMC's Fire Services

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
14810
SOLICITATION NUMBER*
36C24223Q0556
RESPONSE DATE/TIME/ZONE
04-12-2023 16:00 EASTERN TIME, NEW YORK, USA
ARCHIVE
5 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N

SET-ASIDE

PRODUCT SERVICE CODE*
4210
NAICS CODE*
339113
CONTRACTING OFFICE ADDRESS
Bath VA Medical Center

76 Veterans Avenue Bath NY 14810

POINT OF CONTACT*

Contracting Officer Steven Abbey Steven.Abbey@va.gov 607-664-4969

PLACE OF PERFORMANCE

ADDRESS
VA Healthcare System

Northport VA Medical Center

79 Middleville Road

Northport NY

POSTAL CODE
11768
COUNTRY
USA

ADDITIONAL INFORMATION

AGENCY’S URL
https://va.gov
URL DESCRIPTION
VHA
AGENCY CONTACT’S EMAIL ADDRESS
Steven.Abbey@va.gov
EMAIL DESCRIPTION
Network Contracting Office 02

DESCRIPTION

TITLE: 38-Sources Sought Notice

SOL: 36C24223Q0556

DUE: 04/12/2023 at 16:00 (EST) SET ASIDE: Small Business

NAICS: 339113

AGENCY: Department of Veterans Affairs, VA Health Care System, Northport VAMC, 79 Middleville Road, Northport, NY 11768.

POC: Steven Abbey Mail all responses only to: Steven.Abbey@va.gov

DESCRIPTION: This Sources Sought Notice is for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time. This notice is intended strictly for market research. The purpose of this Sources Sought notice is to determine interest and capability of potential qualifications of Small Businesses firms relative to the North American Industry Classification Code (NAICS) 339113. The Department of Veteran’s Affairs is seeking all small business manufacturer or distributors of small business manufacturers, of the following brand name requirement.

Requirement: The Northport VA Medical Center’s Fire Services is requiring the replacement of its older and outdated Air-Pak / SCBA (self-contained breathing apparatus) gear and accessories.

Required Specifications: This is a brand name requirement for 3M™ Scott™ Air-Pak X3 Pro SCBA and accessories

Item#
Description
QTY
X8915025005304
Air-Pak X3 Pro SCBA (2018 Edition) with Snap-

Change, Parachute Buckles, 5.5, Standard, No Accessory Pouch, E-Z Flo+ Regulator with Quick Disconnect Hose (Rectus-type fittings), None, None, No Pak-Tracker, No Case, 2 SCBA Per Box

201276-11
EPIC 3 Radio Direct Interface Voice Amplifier, Open

Bracket Configuration

201215-28
SCOTT NEW AV3000HT 4 POINT - KEVLAR - RT

BRKT - SIZE MED

200970-01
CYL&VALV, QD, CARB,45/5500 ASSY

5500 PSI 45 MINUTE SNAP-CHANGE CYLINDER

200954-15
RIT-PAK III,5.5,LG,AV,RECTUS
200975-01
CYL&VALV, CGA, CARB,75/5500 ASSY

5500 PSI 75 MIN CGA CYL

Warranty: Equipment shall be warrantied against defective materials and workmanship under normal use for a period of one (1) year from the date the equipment is tested and considered satisfactory and fully functional.

Delivery Location:

Northport VAMC 79 Middleville Road Northport, NY 11768

THIS IS NOT A SOLICITATION AND DOES NOT OBLIGATE THE GOVERNMENT TO ISSUE A SOLICITATION. Please be advised that the Government will not pay for any information submitted under this announcement. The applicable North American Classification System (NAICS) Code for this requirement is 339113 Firefighting suits and accessories manufacturing. Email should contain the following information: Name of firm, Socio-Economic category of the firm, complete address, phone & fax number of contacts.

*= Required Field