36C24223Q0092.docx

DOCX document 16 KB Posted

Attached to
6515--Intent to Sole Source Shockwave Catheters 528-23-1-4602-0094
Solicitation number
36C24223Q0092
Issued by

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Special Notice Special Notice

SUBJECT*
Intent to Sole Source Shockwave Catheters 528-23-1-4602-0094

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
12208-3410
SOLICITATION NUMBER*
36C24223Q0092
ARCHIVE
30 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N
PRODUCT SERVICE CODE*
6515
NAICS CODE*
339112

CONTRACTING OFFICE ADDRESS

Department of Veterans Affairs Samuel S . Stratton VA Medical Center 113 Holland Avenue (2-90NCA) Albany NY 12208-3410

POINT OF CONTACT*

Contracting Officer Corey Swinton corey.swinton@va.gov

ADDITIONAL INFORMATION

AGENCY’S URL

URL DESCRIPTION

AGENCY CONTACT’S EMAIL ADDRESS

EMAIL DESCRIPTION

DESCRIPTION

Subject: VHA Buffalo Medical Center SHOCKWAVE Medical Intravascular Lithotripsy

STATEMENT OF WORK (SOW)

1. Contract Title. SHOCKWAVE Medical Intravascular Lithotripsy, IVL OTW catheters

2. Background. The Cardiac Catheterization Lab is requesting the purchase of the Shockwave IVL catheters for the continued use of the SHOCKWAVE medical device that delivers sonic pressure through the catheter to crack both medial and intimal calcium while minimizing trauma to the vessel wall. The IVL catheter is delivered across calcified lesion and the integrated balloon is expanded to 4atm to facilitate efficient energy transfer. This system allows safe and effective deployment of left main, LAD, proximal high- risk lesions stents. The VA Medical Center of Buffalo, NY currently provides best practices to our patients and with the catheters and use will continue.

3. Scope.

The purchase of the Shockwave IVL catheters allows percutaneous coronary intervention of calcified lesions. The Shockwave system meets the specific demands of calcified acute coronary lesions, treatment of distal lesions, chronic total occlusions and 3 vessel disease, and stent thrombosis is a rare event. These catheters are the only catheters that allow the IVL system to work. The device and catheters have been FDA approved and in use in our VA HCS.

1
Shockwave C2 IVL Catheter 2.5 x 12mm - C2IVL2512
3
2
Shockwave C2 IVL Catheter 3.0 x 12mm - C2IVL3012
3
3
Shockwave C2 IVL Catheter 3.5 x 12mm - C2IVL3512
7
4
Shockwave C2 IVL Catheter 4.0 x 12mm - C2IVL4012
9
5
IVL Cable Sleeves (10 pack)
3

4. Requirements.

· Compatible with SHOCKWAVE DEVICE

4.1 SERVICE - The Buffalo VA Medical Center requires that vendors can provide the following services and information about the SHOCKWAVE IVL catheters.

· Vendors must provide educational resources to facility and end users of the product.

· Vendor must have 24hr service support center available.

*= Required Field