RFI Q and A.docx
DOCX document 14 KB Posted
- Attached to
- Y1DZ--620-22-202 Repair Settling Tanks
- Solicitation number
- 36C24222B0080
About this file
This document contains questions and answers related to a federal contract solicitation for repair of settling tanks at a Department of Veterans Affairs facility. The minimum base bid for repair of concrete settling tanks must include 20 square feet of repair per tank, totaling 40 square feet, with unit pricing provided for additional repair work. Chain specifications are also provided for connecting belts and flights on the settling tanks, with Rexnord chains specified as the basis of design.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24222B0080 0006.docx | DOCX document | |
| 36C24222B0080 0005.docx | DOCX document | |
| 36C24222B0080 0004.docx | DOCX document | |
| 36C24222B0080 0003.docx | DOCX document | |
| 36C24222B0080 0002.docx | DOCX document | |
| 36C24222B0080 0001.docx | DOCX document | |
| 52-225-2-Buy-American-Certificate.pdf | ||
| S02 - 620-22-202 Settling Tanks CDs.pdf | ||
| SPECIFICATIONS.zip | ZIP file | |
| 36C24222B0080.docx | DOCX document | |
| P07 - Wage Determination OCT.pdf |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1. Please provide a specification for the chains and flights required Connector belts basis of design is Rexnord NH45 Chain Molded in Tan Acetal Material And Assembled with Stainless Steel Pins:
Chain Material POM Chain Pitch 1.63in Chain Width 2.19in Pin Diameter: 0.63in, Pin Material: Stainless Steel Straight Running, Polymeric, Open Area Type Settlement Tanks chains basis of design is Rexnord NH78 Chain Molded in Tan Acetal Material And Assembled with Stainless Steel Pins:
Chain Material: POM Chain Pitch: 2.609in Chain Width: 2.91in Pin Diameter: 0.88in, Pin Material: Stainless Steel Straight Running, Polymeric, Open Area Type
1. What extent of concrete tank repair should be anticipated for bidding purposes?
Minimum base bid shall include 20SF of concrete repair per tank, totaling 40SF. Additional unit cost per SF shall be included in bid proposals.