S02- 561-19-160_Prosthetics Lab_ Final Bid Drawings NEW_Part6.pdf
PDF 3 MB Posted
- Attached to
- Y1DA--Upgrade prosthetics (VA-22-00010940)
- Solicitation number
- 36C24222B0005
About this file
This pre-solicitation notice is for an upcoming solicitation to upgrade the prosthetics lab at the VA New Jersey Healthcare Systems East Orange Campus. The project scope includes demolition of existing interior walls, finishes, mechanical and electrical components as well as installation of new architectural, mechanical, plumbing and electrical systems. Specific tasks involve demolition work in stairwell A-S7 and rooms A-103G, A-E-102 and A-103J. The estimated cost range for the project is $1-2 million. The NAICS code is 236220 and size standard is $39.5 million. The solicitation number is 36C24222B0005 and will be released on or around November 5, 2020 on SAM.gov. Responses are due based on details in the solicitation. The project requires bonding and responses must be hard copies submitted by verified SDVOSBs registered in VIP and SAM.gov. The completion period is 180 calendar days.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24222B0005 0001.docx | DOCX document | |
| 36C24222B0005.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
F S
FS
PT
PP
S
S
S
S
S
S
S
S
M P
T Z
M P
T Z
P Q R S
40"
CB
80"
36"
80"
80"
80"
TV
80"
80"40"
PANEL 'LPA2'
PANEL 'LCP2'
PANEL 'EMP AD'
PANEL 'P2A'
PANEL 'DP-A'
PANEL 'DP-B'
E
E
E
E E
E
FACP
E
ON WIREMOLD
CONTROL PANEL
GAS ALARMS
E
100A-3P
CIRCUIT BREAKER
E
E
ORTHOTIC
LAB
A-103D
ORTHOTIC
LAB
A-103E
FITTING AREA
A-103C
RECEPTION
A-103K
STORAGE
A-103F
TOILET
A-103B
WHEEL
CHAIR
REPAIR
A-103A
WASTE
A-103G
MECH.
ROOM
A-103J
CORRIDOR
A-103H
ELEC.
A-E-102
ELEC.
A-E-102D
PED
ORTHOTICS
A-103
STAIR
A-S7
TELEPHONE
OPERATOR
SUITE
A-102D
TOILET
A-102B
CHIEF
PROSTH.
PROS.
A-102E
ASSIST.
CHIEF
A-102B
PROSTH.
SVC.
A-102
PROSTH.
SVC.
A-102E
PROSTH.
SVC.
A-102F
PROSTH.
SVC.
A-102G
MECH.
TELE. EQPM
ROOM
A-101B
OFFICE
TELE.
SWITCH
A-101A
TELE. EQPM
ROOM
A-101C
VEST.
A-101B
MECH.
A-103B
VOLUNTEER
A-105A
HAC
A-159 TOILET
A-103B
P Q R S
ORTHOTIC
LAB
A-103D
ORTHOTIC
LAB
A-103E
FITTING AREA
A-103C
RECEPTION
A-103K
STORAGE
A-103F
TOILET
A-103B
WHEEL
CHAIR
REPAIR
A-103A
WASTE
A-103G
MECH.
ROOM
A-103J
CORRIDOR
A-103H
ELEC.
A-E-102
ELEC.
A-E-102D
PED
ORTHOTICS
A-103
STAIR
A-S7
TELEPHONE
OPERATOR
SUITE
A-102D
TOILET
A-102B
CHIEF
PROSTH.
PROS.
A-102E
ASSIST.
CHIEF
A-102B
PROSTH.
SVC.
A-102
PROSTH.
SVC.
A-102E
PROSTH.
SVC.
A-102F
PROSTH.
SVC.
A-102G
MECH.
TELE. EQPM
ROOM
A-101B
OFFICE
TELE.
SWITCH
A-101A
TELE. EQPM
ROOM
A-101C
VEST.
A-101B
MECH.
A-103B
VOLUNTEER
A-105A
HAC
A-159 TOILET
A-103B
N
PROJECT
NORTH
GENERAL AREA
OF WORK
PP
ELECTRICAL PANEL
FACP=FIRE ALARM CONTROL PANEL
DUPLEX RECEPTACLE
QUADRAPLEX RECEPTACLE
SIMPLEX RECEPTACLE
220V SPECIAL RECEPTACLE
WIFI ACCESS POINT
ANTENNA
FUSED DISCONNECT
MOTOR WITH DISCONNECT
2' X 4' LIGHTING FIXTURE
2' X2' LIGHTING FIXTURE
EXIT SIGN, CEILING MOUNTED
ELECTRICAL POWER POLE
ELECTRICAL POKE THRU
ENCLOSED CIRCUIT BREAKER
SINGLE POLE TOGGLE SWITCH
CELING MOUNTED SPEAKER
SECURITY CAMERA
PUSH BUTTON
DEMOLITION HATCH. REMOVE EQUIPMENT BACK TO SOURCE AND MARK AS 'SPARE'
ELECTRICAL DEMOLITION LEGEND
S
M PTZ
PT
CB
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
C U s e rs
\b z h a n g .A
C E
L A
\O n e
D ri v e
A c e la A rc h it e c ts
E n g in e e rs P
.C \D o c u m e n ts \2
-U
S D
V A
-0 M
E P b z h a n g
Y D
J Q
.r v t
/1
/2
:4
:3
A M
ED101
ELECTRICAL POWER AND
LIGHTING DEMOLITION PLANS
6/18/2021 DJW ACELA
EAST ORANGE VAMC 385 TREMONT AVE, EAST ORANGE, NJ
561-19-160UPGRADE PROSTHETIC LABFINAL BID DOCUMENTS
1/8" = 1'-0"1
POWER PLAN DEMOLITION
1/8" = 1'-0"2
LIGHTING PLAN DEMOLITION
KEY PLAN
1. EXISTING LIGHTING FIXTURES, RECEPTACLES, SPECIAL SYSTEMS OUTLETS, CONDUIT, WIRING ETC SHOWN WITHOUT INDICATIONS IN SCOPE SHALL BE DISCONNECTED AND DEMOLISHED. EXISTING CIRCUITRY SHALL BE REMOVED BACK TO SOURCE AND MARK 'SPARE'. ELECTRICAL EQUIPMENT SHOWING 'X' INDICATES EXISTING TO REMAIN. ELECTRICAL EQUIPMENT SHOWING 'RE' INDICATES EXISTING TO BE RELOCATED. THE CONTRACTOR SHALL FIELD VERIFY THE NATURE AND EXTENT OF ALL DEMOLITION WORK AND SHALL INCLUDE COST FOR THE
SAME IN THE BID SUBMITTAL.
2. ALL EXISTING REMOVED ELECTRICAL EQUIPMENT, DEVICES, ETC. THAT ARE NOT RETAINED BY THE OWNER SHALL
BE DISPOSED OF BY THE ELECTRICAL CONTRACTOR.
3. REFER TO ELECTRICAL SYMBOL LEGENDS FOR ALL SYMBOL DESIGNATIONS.
4. MAINTAIN CIRCUIT CONTINUITY TO ALL EXISTING ELECTRICAL SYSTEM COMPONENTS IN AREAS NOT BEING
REMODELED UNLESS OTHERWISE NOTED. PROVIDE ALL CONDUIT AND WIRING EXTENSIONS NECESSARY TO
ACHIEVE SAME.
5. CONTRACTOR SHALL CLOSELY COORDINATE ALL ELECTRICAL DEMOLITION WORK WITH THE GENERAL AND MECHANICAL CONTRACTORS, AND SHALL DISCONNECT ALL REQUIRED CIRCUITS IN A TIMELY MANNER.
6. CONTRACTOR SHALL CONFIRM THE EQUIPMENT IN THE EXISTING LAB AREA TO REMAIN OR TO BE DEMOLISHED
PRIOR TO ROUGH-IN.
ELECTRICAL GENERAL DEMOLITION NOTES
ELECTRICAL KEYED PLAN DEMOLITION NOTES
1 PANEL A & B TO BE REMOVED AND REPLACED WITH NEW AT NEW LOCATIONS.
REFER TO POWER PLAN NEW WORK FOR DETAILS.
REFER TO ARCHITECTURAL DEMOLITION DRAWINGS FOR EQUIPMENT LIST AND DETAILS.
CONTRACTOR SHALL RETURN DEMOLISHED EQUIPMENT BACK TO VA COR FOR FURTHER INSTRUCTIONS.
PANEL 'EMP AD' SHALL BE REMOVED/REINSTALLED BY OTHERS.
EXISTING WALL MOUNTED LIGHTING FIXTURE AND CONDUIT SHALL BE DEMOLISHED. COORDINATE WITH COR TO REMOVE THE CIRCUIT BACK TO SOURCE AND MARK AS 'SPARE' OR RELOCATE THE LIGHTING FIXTURE TO NEW
LOCATION.
Revisions: Date: Page 37 of 43
DLVDLV
DLV
W
W
P H
PHPH
OS
RC
OSRC
OS
P H
LV
OS
RC
OS
PH
OS
OS
LV
P H
D L V
OS
RC
RC
PH
W
OS
OS
OS
OS
RC
L V
L V
W
T R
T R
T R
T R
J
TR
J
T R
J
J
J
T R
T R
T R
TV
T R
J
N
PROJECT
NORTH
GENERAL AREA
OF WORK
P Q R S
PANEL 'LPA2'
PANEL 'LCP2'
PANEL 'P2A'
PANEL 'DP-A'
PANEL 'DP-B'
PANEL 'B'
PANEL 'A'
TELEPHONE BOARD
E
E
E
E
E
E
E
2 (TYP. FOR
ALL EXIT SIGNS)
P2A-9
EM
EM
EM
A-8
A-8 A-8
A-8
A-8
A-8
A-8
A-10 b
NL NL
NL
NL
NL NL
A A A
A A A
A A A
A A A
A A A
A A A
A A A
A A A
A
A A
A A
A A
A A A A
A A A A
A A A A
A A A A
A
A
A A
A A
B
B
B
B
B
B
B
B
B
B
B
B B B
C C
CC
D
D
D a
P2A-9
A-10
G
G
G
G
G
A A
G
P2A-9
G
A A
A A
A A
A A
A A
A A
A A
A
A
A
A
A-10 a a a b b b
A-10
P2A-9 a,b ab ba a,b a a b b a,b
P2A-9 P2A-9
A-10 A-10
A-10
A-10
B B
B
B
F
F
B F
B BF
B BF
B BF
G
P2A-9
NL
NL
NL
NL
NL
C
C
C
A
A
A
A
C C
CC
C C
C C
CC
A
A
A-10
B
NL
E
E
E
G
4 E
TOILET ROOM
A-103
CORRIDOR
A-700A
W/C REPAIR
A-703
EXAM
A-704
CORRIDOR
A-700B
WAITING
A-700
EXAM
A-705
RECEPTION
A-701
SHOE FITTING
A-706
STORAGE
A-707
CORRIDOR
A-700C
ELEC.
A-E-102D
ELECTRICAL
A-E-102
CORRIDOR
A-700D
STORAGE
A-711
TOILET
A-709
STAIR
A-S7
MECH. ROOM
A-103J
MAIN WASTE
A-103G
OFFICE
A-712
OPEN OFFICE
A-700E
OFFICE
A-713
OFFICE
A-714
MECHANICAL ROOM
A-716
LABORATORY
A-715
P Q R S
48"
PANEL 'LPA2'
PANEL 'LCP2'
PANEL 'P2A'
PANEL 'DP-A'
PANEL 'DP-B'
AC
E E
E E
E
E
PANEL 'B'
PANEL 'A'
E
E
TELEPHONE BOARD
LPA2-29
LPA2-29
LPA2-27
LPA2-29
LPA2-29
LPA2-27
LPA2-16
LPA2-31
LPA2-14
LPA2-31
LPA2-33
B-28
LPA2-18 LPA2-18
LPA2-18
LPA2-18
LPA2-18 LPA2-18
P2A-3
P2A-3 P2A-3
FOR SEWING MACHINE
TYPE F
240V/30A/2P
NEMA 1
DISCONNECT
B-13,15
240V/30A/3P
NEMA 1
DISCONNECT
B-20,22,24
DC S2
S2
S1
BS
DP
B-27,29,31
B-8,10,12
240V/30A/3P
NEMA 1
DISCONNECT
240V/30A/3P
NEMA 1
DISCONNECT
B-26
B-26
B-17,19,21
240V/30A/3P
NEMA 1
DISCONNECT
B-14,16,18
B-6
A-18B-26
B-4 B-2
NEW 125A/3P/240V
DEMA 1
FUSED DISCONNECT
FOR HUMIDIFIER
FUSED AT 125A
AC
SC
AC
(TYP. FOR RECEPTACLES
IN WAITING ROOM)
A-18
A-18
P2A-3
AC
P2A-5
P2A-5
LPA2-27
48"
LPA2-16
LPA2-14
LPA2-16
AC
LPA2-29
LPA2-29
LPA2-24
LPA2-24
LPA2-12
LPA2-12
48"
B-30
B-32
B-33
B-33
B-33
AC
LPA2-16
AC AC
48"
SC
LPA2-12
LPA2-31
LPA2-14
LPA2-14
LPA2-14
B-33
B-33
B-33
B-34
B-34
B-34
B-34
B-36
B-33
A-18
A-18
B-35
240V/60A/2P
NEMA 1
DISCONNECT
B-1,3
OV
LPA2-27
P2A-13
TS
TS
P2A-3
LPA2-27
LPA2-31
CLG
CLG
B-26
LPA2-27
LPA2-33
FOR DOOR HOLDER
LPA2-29
P2A-15
TR
TR
LIGHTING FIXTURE SCHEDULE
TYPE
A
B
C
F
MANUFACTURER
COLUMBIA LIGHTING
HUBBELL
MODEL NUMBER
LJT22-35MWG-FSA12-EDU
CWW4-35VW-2WW-EDU
LTR-6SQD-H-ML25L-DM1-LTR-6SQD-T-ML35K8MD-SS
WATTAGE
18W
31W
22.8W
LUMENS
CCT DESCRIPTION
COLUMBIA LIGHTING
6" SQUARE DOWNLIGHT
4' STRIP LIGHTING FIXTURE
2' X 2' TROFFER RECESSED MOUNTED3500K
3500K
3500K
D HUBBELL 4L-P-D-SC254-4-C1-35K 36W 2252 4' PENDANT LIGHTING FIXTURE3500K
G DUAL LITE SESGW 4W EXIT SIGN
CWW2-35VW-2WW-EDUCOLUMBIA LIGHTING 2' STRIP LIGHTING FIXTURE3500K15W 1489
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
C U s e rs
\b z h a n g .A
C E
L A
\O n e
D ri v e
A c e la A rc h it e c ts
E n g in e e rs P
.C \D o c u m e n ts \2
-U
S D
V A
-0 M
E P b z h a n g
Y D
J Q
.r v t
/1
/2
:3
:1
P
M
E101
ELECTRICAL POWER AND
LIGHTING NEW WORK PLANS
6/18/2021 DJW ACELA
EAST ORANGE VAMC 385 TREMONT AVE, EAST ORANGE, NJ
561-19-160UPGRADE PROSTHETIC LABFINAL BID DOCUMENTS
KEY PLAN
REPLACE EXISTING 100A-3P CIRCUIT BREAKER WITH NEW 125A-3P FUSED DISCONNECT FUSED AT 125A. THE EXISTING FEEDERS FROM PANEL 'LCP2' TO THE NEW HUMIDIFIER SHALL BE REPLACED WITH (4)#1 & (1)#6 GRD
IN 2"C.
RECEPTACLES IN WAITING ROOM A-700 AND SHOE FITTING A-702 SHALL BE TAMPER RESISTANT AND
CONTAINS USB PORT FOR CHARGING. (HUBBELL USB15A5I OR EQUIVALENT)
THE FIRE SHUTTER SHALL INTERLOCK WITH FIRE ALARM SYSTEM. WHEN FIRE ALARM SYSTEM IS ACTIVATED, THE FIRE SHUTTER WOULD AUTOMATICALLY OPERATE. REFER TO INSTALLATION MANUAL FOR DETAILS.
(CORNELL COUNTER FIRE DOOR OR EQUIVALENT.)
CONTRACTOR SHALL REROUTE THE CONDUIT RUN WHERE THE NEW DOOR IS BUILT. PROVIDE ENOUGH CONDUCTORS AND CONDUITS FOR EXTENSION OF THE BRANCH CIRCUIT. REFER TO ARCHITECTURAL
DRAWINGS FOR EXACT DOOR LOCATION.
RECEPTACLE MOUNTED ON CEILING FOR PLUG-IN CABLES ON REEL.
REFER TO ELECTROMAGNETIC DOOR HOLDER DETAIL FOR WIRING DIAGRAM.
POWER PLAN KEYED NEW WORK NOTES
1/8" = 1'-0"2
LIGHTING PLAN NEW WORK
CONNECT NEW LIGHTING FIXTURE IN CORRIDOR TO THE EXISTING CORRIDOR LIGHTING CONTROL CIRCUIT ON LIFE SAFETY CIRCUIT VIA NEW ROOM CONTROLLER.THE TOTAL CONNECTED POWER OF THIS BRANCH CIRCUIT SHALL BE LESS THAN 1800VA @120V WITH A 20A-1P CIRCUIT BREAKER. (PANEL
'P2A')
NEW EXIT SIGNS SHALL BE LED GREEN LIGHT AND WALL MOUNTED. REFER TO LIGHTING FIXTURE
SCHEDULE FOR DETAILS.
NEW EXIT SIGNS SHALL BE CONNECTED TO LIFE SAFETY PANEL 'P2A' AHEAD OF SWITCHING.
(1)L-SHAPED RECESSED CHANNEL LED FIXTURE, (1)RECESSED CHANNEL LED FIXTURE ON THE CEILING AND (1)RECESSED CHANNEL LED FIXTURE MOUNTED ON THE WALL SHALL BE PROVIDED. REFER TO
ARCHITECTURAL DRAWING AE201 DETAIL #9. (CORONET LSR1 LED SERIES OR EQUIVALENT.)
LIGHTING FIXTURE MARKED WITH 'NL' AS NIGHT LIGHT SHALL BE CONNECTED TO LIFE SAFETY PANEL
'P2A' AHEAD OF SWITCHING.
LIGHTING PLAN KEYED NEW WORK NOTES
1. REFER TO THE ARCHITECTURAL PLANS FOR EQUIPMENT LAYOUT. CLOSELY COORDINATE THE EXACT LOCATION OF ALL OUTLETS AND DEVICES WITH ARCHITECTURAL ELEVATIONS. ADJUST LOCATIONS AND
MOUNTING HEIGHTS WHERE NECESSARY TO PREVENT INTERFERENCE WITH FURNITURE, FIXED
CASEWORK, EQUIPMENT, ETC. VERIFY ALL CHANGES PRIOR TO ROUGH-IN.
2. ELECTRICAL CONTRACTOR SHALL VERIFY ALL EQUIPMENT LOCATIONS, MOUNTING HEIGHTS, AND CONNECTION REQUIREMENTS (RECEPTACLES, SWITCHES, DISCONNECTS) WITH EQUIPMENT VENDOR
PRIOR TO ROUGH-IN.
3. A DEDICATED NEUTRAL SHALL BE PROVIDED FOR EACH AND EVERY 120V BRANCH CIRCUIT. MULTIWIRE
BRANCH CIRCUITS WITH SHARED NEUTRALS ARE NOT PERMITTED.
4. NEW SPEAKERS IN CORRIDOR SHALL BE CONNECTED TO THE EXISTING PAGING SYSTEM. CONTRACTOR
SHALL VERIFY THE QUANTITIES AND TYPE WITH COR PRIOR TO ROUGH-IN.
5. COMMUNICATION EQUIPMENT SHALL CONNECT TO EXISTING IT ROOM. COORDINATE WITH VA OIT.
6. CONTRACTOR SHALL PROVIDE WIRED SMOKE DETECTORS IN THE CONSTRUCTION AREA DURING
CONSTRUCTION UNTIL NEW SPRINKLER SYSTEM IS FUNCTIONAL. COORDINATE WITH SPRINKLER
CONTRACTOR FOR DETAILS.
7. ALL FIRE ALARM WORK SHALL BE SUPERVISED BY THE FACILITY'S EXISTING FIRE ALARM MAINTENANCE
CONTRACTOR. CONTACT 'KINETIX' @877-223-3000.
POWER PLAN GENERAL NEW WORK NOTES
1/8" = 1'-0"1
POWER PLAN NEW WORK
1. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR FINAL LOCATION OF ALL NEW CEILING MOUNTED LIGHTING FIXTURES. CLOSELY COORDINATE LOCATION OF LIGHTING FIXTURES AND SMOKE DETECTORS WITH HVAC DUCTS, DIFFUSERS, SPRINKLERS, PLUMBING, ETC. AND ADJUST LOCATIONS
OF SELECTED ELECTRICAL EQUIPMENT IN ACCORDANCE WITH ENGINEER'S INSTRUCTIONS.
2. REFER TO ELECTRICAL DETAILS PLANS FOR OCCUPANCY SENSOR WIRING DIAGRAMS AND PROGRAM
SCHEDULE FOR ADDITIONAL INFORMATION.
3. A DEDICATED NEUTRAL SHALL BE PROVIDED FOR EACH AND EVERY 120V BRANCH CIRCUIT.
MULTIWIRE BRANCH CIRCUITS WITH SHARED NEUTRALS ARE NOT PERMITTED.
4. NO MORE THAN (3) SINGLE-PHASE BRANCH CIRCUITS SHALL BE INSTALLED IN ANY ONE CONDUIT.
DIFFERENT POWER SYSTEMS (NORMAL, CRITICAL, LIFE SAFETY) SHALL NOT BE INSTALLED IN THE
SAME CONDUIT.
5. REFER TO LIGHTING FIXTURE SCHEDULE FOR DETAILS.
6. LIGHTING FIXTURE MARK WITH 'NL' SHALL BE CONNECTED TO PANEL 'P2A' AHEAD OF LOCAL
SWITCHING VIA 3/4"C - 2#12 AND 1 #12GRD.
LIGHTING PLAN GENERAL NEW WORK NOTES
Revisions: Date:
T
T N T
NL
M PTZ
P
M P
T Z
NT
N
L
N
PROJECT
NORTH
GENERAL AREA
OF WORK
P Q R S
PANEL 'LPA2'
PANEL 'LCP2'
PANEL 'P2A'
PANEL 'DP-A'
PANEL 'DP-B'
E E
E E
EE
E
TELEPHONE BOARD
E
E
E
E
E
E
E
E
E
E
RF-1
CU-1
AHU
WP
240V/3P/100A
NEMA 3R
DISCONNECT
240V/3P/60A
NEMA 1
DISCONNECT
240V/3P/30A
NEMA 1
DISCONNECT
A-15
(TYP. FOR
ALL VAV BOXES)
A-1,3,5
A-2,4,6
B-7,9,11
E
A-17
E
E
RELOCATED DUCT HEATER
VFD
HUMIDIFIER H-1
(125A FUSED DISC
IN A-E-102)
CONDENSATE PUMP CP-2
(A-22)
E
(TYP. FOR ALL
BASEBOARD HEATERS)
VAV-A-2
VAV-A-1
VAV-A-3
VAV-A-4
VAV-A-5
VAV-A-6
VAV-A-7
VAV-A-8
B-13
MOTOR OPERATED
DAMPERS
(TYP. FOR 4)
EF-3
PANEL 'B'
PANEL 'A'
A-19
NEW 125A-3P/240V
NEMA 1
FUSED DISCONNECT
FOR H-1
FUSED AT 125A
REFER TO POWER
PLAN FOR DETAILS
CONDENSATE PUMP SCP-1
(A-20)
EF-2
A-19
VAV-A-9
TOILET ROOM
A-103
VESTIBULE
A-101B
W/C REPAIR
A-703
EXAM
A-704
CORRIDOR
A-700A
WAITING
A-700
CORRIDOR
A-700B
EXAM
A-705
SHOE FITTING
A-706
RECEPTION
A-701
STORAGE
A-707
CORRIDOR
A-700C
ELEC.
A-E-102D
ELECTRICAL
A-E-102
STAIR
A-S7
MECH. ROOM
A-103J
MAIN WASTE
A-103G
CORRIDOR
A-700D
STORAGE
A-711
TOILET
A-709
OFFICE
A-712
OPEN OFFICE
A-700E
OFFICE
A-713
OFFICE
A-714
MECHANICAL ROOM
A-716
LABORATORY
A-715
MECHANICAL EQUIPMENT SCHEDULE
DESIGNATION
AHU
CU-1
RF-1
VOLTAGE/PHASE
208/3
FLA
18A
OCPD
40A
DESCRIPTION
HUMIDIFIER
EXHAUST FAN
CONDENSING UNIT
AIR HANDLING UNIT
RETURN FAN
H-1
EF-2,3 120/1
208/3
56A208/3
4.1A,0.19A
11A
80A
20A
15A
125A
VARIABLE-AIR-VOLUME BOXVAV-A-1~8 120/1 20A
208/3 93.4A
CONDENSATE PUMPCP-2 120/1 5.8A 20A
CONDENSATE PUMPSCP-1 120/1 7.2A 20A
P Q R S
TOILET ROOM
A-103
CORRIDOR
A-700A
W/C REPAIR
A-703
EXAM
A-704
WAITING
A-700
CORRIDOR
A-700B
EXAM
A-705
SHOE FITTING
A-706
RECEPTION
A-701
STORAGE
A-707
CORRIDOR
A-700C
ELEC.
A-E-102D
ELECTRICAL
A-E-102
STAIR
A-S7
MECH. ROOM
A-103J
MAIN WASTE
A-103G
CORRIDOR
A-700D
STORAGE
A-711
TOILET
A-709
OFFICE
A-712
OPEN OFFICE
A-700E OFFICE
A-713
OFFICE
A-714
LABORATORY
A-715
MECHANICAL ROOM
A-716
VESTIBULE
A-101B
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
C U s e rs
\b z h a n g .A
C E
L A
\O n e
D ri v e
A c e la A rc h it e c ts
E n g in e e rs P
.C \D o c u m e n ts \2
-U
S D
V A
-0 M
E P b z h a n g
Y D
J Q
.r v t
/1
/2
:4
:3
A
M
E102
ELECTRICAL EQUIPMENT AND
AUXILIARY NEW WORK PLANS
6/18/2021 DJW ACELA
EAST ORANGE VAMC 385 TREMONT AVE, EAST ORANGE, NJ
561-19-160UPGRADE PROSTHETIC LABFINAL BID DOCUMENTS
KEY PLAN
1/8" = 1'-0"1
EQUIPMENT PLAN NEW WORK
EXISTING BRANCH CIRCUIT FOR THE BASEBOARD HEATER TO REMAIN.
COORDINATE WITH MECHANICAL CONTRACTOR REGARDING THE INSTALLATION OF VAV BOXES. DISCONNECT
SWITCH AND LOW
VOLTAGE TRANSFORMER SHALL BE PROVIDED BY MANUFACTURER OR MECHANICAL CONTRACTOR.
EXISTING BRANCH CIRCUIT FOR THE DUCT HEATER TO REMAIN. CONTRACTOR SHALL PROVIDE ADEQUATE
MATERIALS TO EXTEND
EXISTING BRANCH CIRCUIT INCLUDING CONDUCTORS AND CONDUITS. NEW MATERIALS SHALL MATCH THE
EXISTING.
EQUIPMENT PLAN KEYED NEW WORK NOTES
1. REFER TO THE ARCHITECTURAL PLANS FOR EQUIPMENT LAYOUT. CLOSELY COORDINATE THE EXACT LOCATION OF ALL OUTLETS AND DEVICES WITH ARCHITECTURAL ELEVATIONS. ADJUST LOCATIONS AND
MOUNTING HEIGHTS WHERE NECESSARY TO PREVENT INTERFERENCE WITH FURNITURE, FIXED
CASEWORK, EQUIPMENT, ETC. VERIFY ALL CHANGES PRIOR TO ROUGH-IN.
2. ELECTRICAL CONTRACTOR SHALL VERIFY ALL EQUIPMENT LOCATIONS, MOUNTING HEIGHTS, AND CONNECTION REQUIREMENTS (RECEPTACLES, SWITCHES, DISCONNECTS) WITH EQUIPMENT VENDOR AND
MECHANICAL/PLUMBING CONTRACTOR PRIOR TO ROUGH-IN.
3. A DEDICATED NEUTRAL SHALL BE PROVIDED FOR EACH AND EVERY 120V BRANCH CIRCUIT. MULTIWIRE
BRANCH CIRCUITS WITH SHARED NEUTRALS ARE NOT PERMITTED.
EQUIPMENT GENERAL NEW WORK NOTES
1/8" = 1'-0"2
AUXILIARY PLAN NEW WORK
SECURITY EQUIPMENT SHALL CONNECT TO MONITORING SYSTEM OF VA SECURITY CONTROL CENTER (SCC).
VASS CAMERA SHALL BE INTEGRATED WITH PANIC ALARM. ONCE THE ALARM HAS BEEN ACTIVATED THE
VASS SHALL MONITOR AND RECORD ALL EVENTS ASSOCIATED WITH THE ALARM.
THE EMERGENCY PULL CORD AND INDICATOR SHALL CONNECT TO THE MONITORING SYSTEM OF VA
SECURITY CONTROL CENTER (SCC) AND SEND NOTIFICATION TO THE RECEPTION DESK.
AUXILIARY PLAN KEYED NEW WORK NOTES
1. REFER TO THE ARCHITECTURAL PLANS FOR EQUIPMENT LAYOUT. CLOSELY COORDINATE THE EXACT LOCATION OF ALL OUTLETS AND DEVICES WITH ARCHITECTURAL ELEVATIONS. ADJUST LOCATIONS AND
MOUNTING HEIGHTS WHERE NECESSARY TO PREVENT INTERFERENCE WITH FURNITURE, FIXED
CASEWORK, EQUIPMENT, ETC. VERIFY ALL CHANGES PRIOR TO ROUGH-IN.
2. ELECTRICAL CONTRACTOR SHALL VERIFY ALL EQUIPMENT LOCATIONS, MOUNTING HEIGHTS, AND CONNECTION REQUIREMENTS (CALL STATIONS, PULL CORDS, ETC.) WITH EQUIPMENT VENDOR PRIOR TO
ROUGH-IN.
3. A DEDICATED NEUTRAL SHALL BE PROVIDED FOR EACH AND EVERY 120V BRANCH CIRCUIT. MULTIWIRE
BRANCH CIRCUITS WITH SHARED NEUTRALS ARE NOT PERMITTED.
AUXILIARY PLAN GENERAL NEW WORK NOTES
Revisions: Date: Page 39 of 43
F S
F S
S
S
S
S
S
S
S
S
S
S
FS
DH
P Q R S
1(TYP.)
AC
AC
TOILET ROOM
A-103
CORRIDOR
A-700A
VESTIBULE
A-101B
W/C REPAIR
A-703
EXAM
A-704
CORRIDOR
A-700A
EXAM
A-705
CORRIDOR
A-700B
WAITING
A-700
SHOE FITTING
A-706
RECEPTION
A-701
STORAGE
A-707
CORRIDOR
A-700C
ELEC.
A-E-102D
ELECTRICAL
A-E-102
STAIR
A-S7
STORAGE
A-711
TOILET
A-709
OFFICE
A-712 CORRIDOR
A-700D
MAIN WASTE
A-103G
MECH. ROOM
A-103J
OFFICE
A-713
OPEN OFFICE
A-700E
OFFICE
A-714
MECHANICAL ROOM
A-716
LABORATORY
A-715
P Q R S
FACP
E
2(TYP. FOR CLG SPEAKER)
TS
FD
FD
VESTIBULE
A-101B
TOILET ROOM
A-103
CORRIDOR
A-700A
W/C REPAIR
A-703
EXAM
A-704
EXAM
A-705CORRIDOR
A-700B
WAITING
A-700
RECEPTION
A-701
SHOE FITTING
A-706
STORAGE
A-707
CORRIDOR
A-700C
ELEC.
A-E-102D
ELECTRICAL
A-E-102
STAIR
A-S7
CORRIDOR
A-700D
STORAGE
A-711
TOILET
A-709
OFFICE
A-712
MECH. ROOM
A-103J
MAIN WASTE
A-103G
OFFICE
A-713
OPEN OFFICE
A-700E
OFFICE
A-714
MECHANICAL ROOM
A-716
LABORATORY
A-715
CONTROL
MODULE
TYPICAL
INITIATING
CIRCUIT LOOP
TYPICAL A/V SIGNAL
CIRCUITEOL
E X
IS
T
IN
G
F
IR
E A
L A
R M
C O
N T
R O
L P
A N
E L
(A -E
-1
NOT TO SCALE
NOTES:
1. CONTRACTOR SHALL PROVIDE FIRE ALARM SHOP DRAWINGS IN
ACCORDANCE WITH THE 2015 IBC SECTION 907.1.2. THE SHOP
DRAWINGS SHALL BE SIGNED & SEALED BY A LICENSED
PROFESSIONAL ENGINEER WHICH SHALL INCLUDE BUT NOT LIMITED TO
THE FOLLOWING:
a. FIRE ALARM PLAN
b. POINT TO POINT RISER DIAGRAM
c. BATTERY CALCULATIONS
d. VOLT DROP CALCULATIONS
e. FIRE ALARM WIRE TYPES
f. CUT SHEETS OF PANEL & ALL DEVICES
2. THIS DIAGRAM IS FOR BASIC CONCEPT ONLY. SYSTEM SHALL BE
WIRED IN ACCORDANCE W/AN APPROVED SET OF WIRING DIAGRAMS
INCLUDED IN THE FIRE ALARM SHOP
DRAWINGS.
3. PROVIDE LINE ISOLATION MONITOR MODULES.
FIRE ALARM SYSTEM WIRING
FS
S S
SHUTOFF
RELAYDUCT SMOKE
DETECTOR
SHUTOFF
RELAYFIRE DOOR
SHUTTER MOTOR
(A-701)
FD DH
N
PROJECT
NORTH
GENERAL AREA
OF WORK
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
C U s e rs
\b z h a n g .A
C E
L A
\O n e
D ri v e
A c e la A rc h it e c ts
E n g in e e rs P
.C \D o c u m e n ts \2
-U
S D
V A
-0 M
E P b z h a n g
Y D
J Q
.r v t
/1
/2
:4
:4
A
M
E103
ELECTRICAL TELECOM AND FIRE
ALARM PLANS
6/18/2021 DJW ACELA
EAST ORANGE VAMC 385 TREMONT AVE, EAST ORANGE, NJ
561-19-160UPGRADE PROSTHETIC LABFINAL BID DOCUMENTS
1/8" = 1'-0"1
TELECOMMUNICATION PLAN NEW WORK
1/8" = 1'-0"2
FIRE ALARM PLAN NEW WORK
PROVIDE 2-PORT SURFACE MOUNTED BOX WITH RJ45 JACKS ABOVE FINISHED CEILING FOR WIRELESS ACCESS POINTS (WAP). PROVIDE 15' OF ADDITIONAL CAT6A CABLING FOR FUTURE ADJUSTMENTS.
COORDINATE LOCATION OF WAPs WITH VA COR PRIOR TO INSTALLATION. REFER TO TECHNOLOGY DETAILS FOR ADDITIONAL INFORMATION. TYPICAL FOR ALL WAPs.
TELECOM OUTLET FOR TV SHALL BE MOUNTED AT THE SAME HEIGHT AS THE TV POWER RECEPTACLE.
TELECOMMUNICATION PLAN KEYED NEW WORK NOTES
1. REFER TO THE ARCHITECTURAL PLANS FOR EQUIPMENT LAYOUT. CLOSELY COORDINATE THE EXACT LOCATION OF ALL OUTLETS AND DEVICES WITH ARCHITECTURAL ELEVATIONS. ADJUST LOCATIONS AND
MOUNTING HEIGHTS WHERE NECESSARY TO PREVENT INTERFERENCE WITH FURNITURE, FIXED
CASEWORK, EQUIPMENT, ETC. VERIFY ALL CHANGES PRIOR TO ROUGH-IN.
2. ELECTRICAL CONTRACTOR SHALL VERIFY ALL EQUIPMENT LOCATIONS, MOUNTING HEIGHTS, AND CONNECTION REQUIREMENTS (DATA OUTLETS, WIFI ACCESS POINTS, ANTENNA.) WITH EQUIPMENT
VENDOR PRIOR TO ROUGH-IN.
3. A DEDICATED NEUTRAL SHALL BE PROVIDED FOR EACH AND EVERY 120V BRANCH CIRCUIT. MULTIWIRE
BRANCH CIRCUITS WITH SHARED NEUTRALS ARE NOT PERMITTED.
4. TELECOMMUNICATION EQUIPMENT SHALL CONNECT TO EXISTING IT ROOM. COORDINATE WITH VA OIT.
TELECOMMUNICATION PLAN GENERAL NEW WORK NOTES
CONNECT NEW FIRE ALARM EQUIPMENT TO THE EXISTING FIRE ALARM CONTROL PANEL.
THE CEILING MOUNTED SPEAKER SHALL INTERLOCK WITH EXISTING FIRE ALARM SYSTEM AND NOTIFICATION SYSTEM. EC SHALL COORDINATE WITH FIRE ALARM CONTRACTOR AND VA OIT FOR CONNECTION DETAILS.
INSTALL NEW DUCT SMOKE DETECTOR WITH SHUT OFF RELAY AND TEST SWITCH FOR NEW AIR HANDLER UNIT SUPPLY AIR DISCHARGE. COORDINATE WITH MECHANICAL CONTRACTOR FOR EXACT LOCATION.
THE FIRE SHUTTER SHALL INTERLOCK WITH FIRE ALARM SYSTEM VIA THE SMOKE DETECTOR. WHEN FIRE ALARM SYSTEM IS ACTIVATED, THE FIRE SHUTTER WOULD AUTOMATICALLY OPERATE. REFER TO
INSTALLATION MANUAL FOR DETAILS. (CORNELL COUNTER FIRE DOOR OR EQUIVALENT.)
REFER TO ELECTROMAGNETIC DOOR HOLDER DETAIL FOR WIRING DIAGRAM.
FIRE ALARM PLAN KEYED NEW WORK NOTES
1. REFER TO THE ARCHITECTURAL PLANS FOR EQUIPMENT LAYOUT. CLOSELY COORDINATE THE EXACT LOCATION OF ALL OUTLETS AND DEVICES WITH ARCHITECTURAL ELEVATIONS. ADJUST LOCATIONS AND
MOUNTING HEIGHTS WHERE NECESSARY TO PREVENT INTERFERENCE WITH FURNITURE, FIXED
CASEWORK, EQUIPMENT, ETC. VERIFY ALL CHANGES PRIOR TO ROUGH-IN.
2. ELECTRICAL CONTRACTOR SHALL VERIFY ALL EQUIPMENT LOCATIONS, MOUNTING HEIGHTS, AND CONNECTION REQUIREMENTS (PULL STATIONS, SPEAKERS, DUCT SMOKE DETECTOR.) WITH EQUIPMENT
VENDOR PRIOR TO ROUGH-IN.
3. NEW SPEAKERS IN CORRIDOR SHALL BE CONNECTED TO THE EXISTING PAGING SYSTEM. CONTRACTOR
SHALL VERIFY THE QUANTITIES AND TYPE WITH COR PRIOR TO ROUGH-IN.
4. CONTRACTOR SHALL PROVIDE WIRED SMOKE DETECTORS IN THE CONSTRUCTION AREA DURING
CONSTRUCTION UNTIL NEW SPRINKLER SYSTEM IS FUNCTIONAL. COORDINATE WITH SPRINKLER
CONTRACTOR FOR DETAILS.
5. ALL FIRE ALARM WORK SHALL BE SUPERVISED BY THE FACILITY'S EXISTING FIRE ALARM MAINTENANCE
CONTRACTOR. CONTACT 'KINETIX' @877-223-3000.
FIRE ALARM PLAN GENERAL NEW WORK NOTES
Revisions: Date:
KEY PLAN
(E) SUBSTATION AE
3200A
600A
(E)
PANEL
DP-B
BKR-19
(E)
PANEL
P2A
(E) SUBSTATION AN
3200A
300A
(E)
PANEL
LCP2
BKR-12
(E)
PANEL
LPA2
400ABKR-7
(N)
PANEL
A
(N)
PANEL
B
3200A
(E)800KW GENERATOR
G
FROM MAIN SWITCHGEAR
FROM MAIN SWITCHGEAR
225A (A-E-106)
SEE NOTE #1
PROPOSED SINGLE-LINE DIRAGRAM
NTS
3200A
208/120V 208/120V
NEW HUMIDIFIER
IN MECHANICAL ROOM
A-716
125A/3P/240V
NEMA 1
FUSED DISC
FUSED AT
125A
(A-E-102)
(4) #3/0 & (1) #6 GRD IN 2"C
(4) #1 & (1) #6 GRD IN 2"C
NORMAL POWER IN
MECHANICAL ROOM A-716
NORMAL POWER IN
ELECTRICAL A-E-102
CRITICAL/LIFE SAFETY POWER
IN ELEC. A-E-102D
NOTE:
1. REFER TO ARCHITECTURAL DRAWING GI201 FOR ELECTRICAL CLOSET A-E-106 LOCATION. EC SHALL
VERIFY THE LOCATION OF THE EXISTING ENCLOSED CIRCUIT BREAKER AND THE LENGTH OF THE
FEEDERS TO PANEL A AND B. THE ELECTRICAL WORK SHALL BE ONLY AT NIGHT TIME.
PROJECT: 20-USDVA-04
RATING: 208/120V, 4W, 3PH, 200A
CKT. CIRCUIT
DESCRIPTION
13 EXISTING SHOE MACHINE (EQ S2)
NEW FLOOR RECEPT
SEWING MACHINE (EQ SM)
(EQ B2)
SPACE
SPACE
SPACE
PANEL TYPE: NEMA 1
MOUNTING: SURFACE
MAIN LUGS ONLY
INTERRUPTING RATING: 14KA SYM.
FED FROM: 225A DISCONNECT IN A-128D
NOTES
1. ALL BUSING TO BE COPPER
2. BOLT ON BREAKERS ONLY
3. CONTRACTOR IS RESPONSIBLE TO COORDINATE THE SHORT CIRCUIT RATING AT THE UTILITY TRANSFORMER SECONDARY'S PRIOR TO PURCHASING ANY EQUIPMENT.
4. ALL WIRE SIZES ARE BASED ON 75 DEGREE WIRE.
5. EXISTING CONDUCTORS AND FEEDERS TO REMAIN. CONTRACTOR SHALL PROVIDE NEW TO EXTEND EXISTING WIRES AND CONDUITS. NEW WIRES AND CONDUITS SHALL MATCH THE EXISTING.
6. CONTRACTOR SHALL VERIFY BRANCH CIRCUITS (WIRE SIZE AND PHASE) ON DEMOLISHED PANEL B AND RELOCATE TO NEW PANEL B IF IN USE.
OVEN (EQ OV)
SPARE
NEW CONDENSING UNIT
PANEL 'B'
(NEW)
POLE LOAD BKR.
KVA SIZE
6.7
6.7
6.7
1.2
1.2
1.4
1.4
1.4
BRANCH
CIRCUIT
7.4
4#4&1#8GRD IN 1-1/4"C
EXISTING
4#12&1#12GRD IN 3/4"C
1.0
3.0
1.8
1.7
0.0
0.0
0.0
TOTAL (PHASE):
TOTAL CONN.:
21.8 22.6 17.6
62.0 KVA
TOT. CONN. + SPARE: 68.2 KVA
DEMAND: 54.6 KVA
DEMAND: 151.7 AMPS
SPARE CAPACITY
DEMAND FACTOR
10 %
80 %
3.0
3.0
3.0
3.0
3.2
2.7
2.7
1.3
2#12&1#12GRD IN 3/4"C 20
EXISTING 20
EXISTING 20
7.4
7.4
EXISTING 20
A
4.7
4.7
1.0
B C BRANCH
CIRCUIT
EXISTING
EXISTING
2#12&1#12GRD IN 3/4"C
BKR. LOAD POLE
SIZE KVA
0.7
0.7
1.0
0.7
0.7
0.7
1.8
1.8
1.8
1.3
1.3
1.3
1.0
LOCATION: MECHANICAL ROOM
CIRCUIT
DESCRIPTION
EXISTING DISC SANDER (EQ S1)
EXISTING ROLL SANDER (EQ S2) 4
MICROWAVE
EXISTING
DRILL PRESS (EQ DP)
AIR COMPRESSOR (EQ C)
DUST COLLECTOR (EQ DC)
WORKSTATION
SPACE
SPACE
SPACE
(RELOCATED FROM B-32,34,36) 12
EXISTING 14
(RELOCATED FROM B-32,34,36) 18
EXISTING
(RELOCATED FROM B-38,40,42) 24
FLOOR DUPLEX RECEPT
CKT.
PROJECT: 20-USDVA-04
RATING: 208/120V, 4W, 3PH, 200A
CKT. CIRCUIT
DESCRIPTION
RETURN FAN RF-1 - NOTE 5
BASEBOARD HEAT A-103C&K
BASEBOARD HEAT
VAV BOXES -NOTE 5
ACTUATORS - NOTE 5
EF-2, EF-3 - NOTE 5
SPARE
SPARE
SPACE
SPACE
SPACE
PANEL TYPE: NEMA 1
MOUNTING: SURFACE
MAIN CIRCUIT BREAKER: 225A
INTERRUPTING RATING: 14KA SYM.
FED FROM: 225A DISCONNECT IN A-128D
NOTES
1. ALL BUSING TO BE COPPER
2. BOLT ON BREAKERS ONLY
3. CONTRACTOR IS RESPONSIBLE TO COORDINATE THE SHORT CIRCUIT RATING AT THE UTILITY TRANSFORMER SECONDARY'S PRIOR TO PURCHASING ANY EQUIPMENT.
4. ALL WIRE SIZES ARE BASED ON 75 DEGREE WIRE.
5. REUSE EXISTING CIRCUIT BREAKER.
6. REPLACE WITH NEW CIRCUIT BREAKER. NEW CIRCUIT BREAKER SHALL MATCH WITH EXISTING IN SO AS MANUFACTURER, TYPE AND AIC RATING.
7. CONTRACTOR SHALL VERIFY BRANCH CIRCUITS ON DEMOLISHED PANEL A AND RELOCATE TO NEW PANEL A IF IN USE.
PANEL 'A'
(NEW)
POLE LOAD BKR.
KVA SIZE
1.3
1.3
1.3
1.2
1.2
1.2
1.2
0.5
0.5
1.5
0.0
0.0
0.0
TOTAL (PHASE):
TOTAL CONN.:
0.0
10.2 9.3 7.3
26.8 KVA
TOT. CONN. + SPARE: 29.5 KVA
DEMAND: 23.6 KVA
DEMAND: 65.5 AMPS
SPARE CAPACITY
DEMAND FACTOR
10 %
80 %
BRANCH
CIRCUIT
4#12&1#12GRD IN 3/4"C
EXISTING
EXISTING
2.2
2#12&1#12GRD IN 3/4"C
2#12&1#12GRD IN 3/4"C
1.5
1.6 2.3
2.1
0.0
2#12&1#12GRD IN 3/4"C
2.2
2.2
2.2
EXISTING
A
3.5
3.5
3.5
2#12&1#12GRD IN 3/4"C
2#12&1#12GRD IN 3/4"C
4#8&1#10GRD IN 1"C
B C BRANCH
CIRCUIT
BKR. LOAD POLE
SIZE KVA
2.2
2.2
2.2
1.0
1.0
1.0
1.0
1.0
1.1
LOCATION: MECHANICAL ROOM
CIRCUIT
DESCRIPTION
AIR HANDLING UNIT - NOTE 6
LIGHTING - NOTE 6
LIGHTING - NOTE 6
EXISTING
SPARE
SPARE
SPACE
SPACE
SPACE
(RELOCATED FROM A-16,18,20) 16
MECHANICAL ROOM REC 18
CKT.
PROJECT: 20-USDVA-04
RATING: 208/120V, 4W, 3PH, 100A
CKT. CIRCUIT
DESCRIPTION
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
27 WAITING/RECEP RECS - NOTE 5
EXAM RECS - NOTE 5
CORRIDOR RECS - NOTE 5
WAITING ROOM TV - NOTE 5
SPACE
PANEL TYPE: NEMA 1
MOUNTING: SURFACE
MAIN LUGS ONLY
INTERRUPTING RATING: 14KA SYM.
FED FROM: 300A DISCONNECT ON PANEL LCP2
NOTES
1. ALL BUSING TO BE COPPER
2. BOLT ON BREAKERS ONLY
3. CONTRACTOR IS RESPONSIBLE TO COORDINATE THE SHORT CIRCUIT RATING AT THE UTILITY TRANSFORMER SECONDARY'S PRIOR TO PURCHASING ANY EQUIPMENT.
4. ALL WIRE SIZES ARE BASED ON 75 DEGREE WIRE.
5. REUSE EXISTING CIRCUIT BREAKER.
PANEL 'LPA2'
(EXISTING)
POLE LOAD BKR.
KVA SIZE
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.1
1.1
1.1
BRANCH
CIRCUIT
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
2#12&1#12GRD IN 3/4"C
2#12&1#12GRD IN 3/4"C
2#12&1#12GRD IN 3/4"C
A
2.0
2.0
2.0
2.0
2.0
1.7
1.9
1.7
2.1
2.0
2.0
2.1
2.0
1.7
2.1
2.1
2.0
TOTAL (PHASE):
TOTAL CONN.:
12.0 11.8 0.0 10.0
33.8 KVA
TOT. CONN. + SPARE: 37.2 KVA
DEMAND: 29.7 KVA
DEMAND: 82.7 AMPS
SPARE CAPACITY
DEMAND FACTOR
10 %
80 %
EXISTING 20
EXISTING 30
EXISTING
B C BRANCH
CIRCUIT
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
2#12&1#12GRD IN 3/4"C
2#12&1#12GRD IN 3/4"C
2#12&1#12GRD IN 3/4"C
EXISTING
EXISTING
BKR. LOAD POLE
SIZE KVA
1.0
1.0
1.0
1.0
1.0
0.7
0.9
1.1
1.0
1.0
1.0
1.0
1.0
1.0
1.0
LOCATION: A-E-102
CIRCUIT
DESCRIPTION
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
RECS FOR OFFICES - NOTE 5
EXISTING
EXISTING
W/C REPAIR RECS - NOTE 5
EXISTING
EXISTING
EXISTING
SPACE
CKT.
PROJECT: 20-USDVA-04
RATING: 208/120V, 4W, 3PH, 125A
CKT. CIRCUIT
DESCRIPTION
A/C 171
RECEPTION RECS - NOTE 5
EXAM ROOM - NOTE 5
EXAM ROOM - NOTE 5
FUME FAN
PANEL 'P2A'
(EXISTING)
9 MECH/EXAM/WAITING LTG -NOTE 5 1
DOOR HOLDER - NOTE 6
DEMO TO SPARE
PANEL TYPE: NEMA 1
MOUNTING: SURFACE
MAIN LUGS ONLY
INTERRUPTING RATING: 14KA SYM.
FED FROM: 125A DISCONNECT ON PANEL DP-B
NOTES
1. ALL BUSING TO BE COPPER
2. BOLT ON BREAKERS ONLY
3. CONTRACTOR IS RESPONSIBLE TO COORDINATE THE SHORT CIRCUIT RATING AT THE UTILITY TRANSFORMER SECONDARY'S PRIOR TO PURCHASING ANY EQUIPMENT.
4. ALL WIRE SIZES ARE BASED ON 75 DEGREE WIRE.
5 . REUSE EXISTING CIRCUIT BREAKER.
POLE LOAD BKR.
KVA SIZE
1.5
1.0
1.0
1.0
1.0
1.5
0.0
TOTAL (PHASE):
TOTAL CONN.:
7.3
1.0
6.5
0.0
4.5
18.3 KVA
TOT. CONN. + SPARE: 22.0 KVA
DEMAND: 17.6 KVA
DEMAND: 48.8 AMPS
SPARE CAPACITY
DEMAND FACTOR
EXISTING 20
20 %
80 %
1.0 1
EXISTING
SPACE
BRANCH
CIRCUIT
EXISTING
2#12&1#12GRD IN 3/4"C
2#12&1#12GRD IN 3/4"C
2#12&1#12GRD IN 3/4"C
2#12&1#12GRD IN 3/4"C
EXISTING
A
2.5
2.0
2.0
2.0
2.0
2.5
2.8
1.5
0.0 20
EXISTING 20
B C BRANCH
CIRCUIT
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
BKR. LOAD POLE
SIZE KVA
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
LOCATION: A-E-102D
CIRCUIT
DESCRIPTION
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
SPARE
CKT.
NEW BAND SAW
2.0
3 25 4#10&1#10GRD IN 3/4"C2.0
2.0
2#12&1#12GRD IN 3/4"C
2#12&1#12GRD IN 3/4"C
0.8
0.6
CONDENSATE PUMP SCP-1
CONDENSATE PUMP CP-2
WORKSTATION
WORKSTATION
1.0
1.0
1.0
2#12&1#12GRD IN 3/4"C
2#12&1#12GRD IN 3/4"C
2#12&1#12GRD IN 3/4"C
2#12&1#12GRD IN 3/4"C 0.7 STORAGE RM RECS - NOTE 5
1.12#12&1#12GRD IN 3/4"C 20
SPARE 1 20
2#12&1#12GRD IN 3/4"C
SPACE
1 20
LAB RECEPTACLES 1 20 2#12&1#12GRD IN 3/4"C1.1
FIRE SHUTTER - NOTE 5
W/C REPAIR RECS - NOTE 5
STORAGE RM RECS - NOTE 5
COPIER 1 20 2#12&1#12GRD IN 3/4"C0.7
20 OFFICE A-712 & BREAK AREA0.7 12#12&1#12GRD IN 3/4"C
20 REFRIGERATOR1.0 12#12&1#12GRD IN 3/4"C
1 20
3#6&1#10GRD IN 1"C
1.8 2#12&1#12GRD IN 3/4"C
4.0 4.0
SPARE 1 20
SPARE 1 20
33 1.0 2#12&1#12GRD IN 3/4"C
6. REPLACE WITH NEW CIRCUIT BREAKER. NEW CIRCUIT BREAKER SHALL MATCH WITH EXISTING IN SO AS MANUFACTURER, TYPE AND AIC RATING.
200.5 2#12&1#12GRD IN 3/4"C
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
C U s e rs
\b z h a n g .A
C E
L A
\O n e
D ri v e
A c e la A rc h it e c ts
E n g in e e rs P
.C \D o c u m e n ts \2
-U
S D
V A
-0 M
E P b z h a n g
Y D
J Q
.r v t
/1
/2
:4
:4
A
M
E201
ELECTRICAL PANEL SCHEDULES
AND SINGLE LINE DIAGRAM
6/18/2021 DJW ACELA
EAST ORANGE VAMC 385 TREMONT AVE, EAST ORANGE, NJ
561-19-160UPGRADE PROSTHETIC LABFINAL BID DOCUMENTS
Revisions: Date: Page 41 of 43
Violet G
V1 H1 N
Dimming
Load
#1
G
H2 N
B la c k
/2
/3
V
A C
W h it e
N e u tr a l)
Gray
R e d
B lu e V io le t/ S tr ip e d
G ra y
White
W h it e
Dimming
Load
#2
V2
NXRC-2RD
BA
CAT5 Cable
OCC
PC
B u il d in g A u to m a ti o n
H U
B B
E L L
R
Red 24VDC
Yellow Black
18AWG standard low voltage wire
NXDS-U
Photo Sensor
(As required per Room)
S V
C
P W
R S
V C
P
IN
NXSW SERIES
(As required per Room)
(As required per Room)
OCC
PC
B u il d in g A u to m a ti o n
H U
B B
E L L
R
Red 24VDC
Blue
Black
18AWG standard low voltage wire
Low Voltage
Occupancy Sensor
(OMNI)
Low Voltage
Occupancy Sensor
(OMNI)
Low Voltage
Occupancy Sensor
(OMNI)
S V
C
P W
R S
V C
P
IN
S V
C
P W
R S
V C
P
IN
S V
C
P W
R S
V C
P
IN
Low Voltage Occupancy Sensor
(NX-OS-LODTR)
ROOM
CONTROLLER
2 OUTPUTS
WITH
DIMMING
Typical Mounting
HubNET Network
NX Bridge Module (Typical)
(As required) Junction Box
CAT5 Cable
To next bridge
From previous bridge
CAT5 Cable
CAT5 Cable
NXRC-2R
BA
CAT5 Cable
OCC
PC
B u il d in g A u to m a ti o n
H U
B B
E L L
R
Red 24VDC
Yellow Black
18AWG standard low voltage wire
NXDS-U
Photo Sensor
(As required per Room)
S V
C
P W
R S
V C
P
IN
NXSW SERIES
(As required per Room)
(As required per Room)
OCC
PC
B u il d in g A u to m a ti o n
H U
B B
E L L
R
Red 24VDC
Blue
Black
18AWG standard low voltage wire
Low Voltage
Occupancy Sensor
(OMNI)
Low Voltage
Occupancy Sensor
(OMNI)
Low Voltage
Occupancy Sensor
(OMNI)
S V
C
P W
R S
V C
P
IN
S V
C
P W
R S
V C
P
IN
S V
C
P W
R S
V C
P
IN
Low Voltage Occupancy Sensor
(NX-OS-LODTR)
ROOM
CONTROLLER
2 OUTPUT
ON/OFF
H1 N
Load #1
H2 N
B la c k
/2
/3
V
A C
W h it e
N e u tr a l)
R e d
B lu e
White
W h it e
Load #2
Typical Mounting
HubNET Network
NX Bridge Module (Typical)
(As required) Junction Box
CAT5 Cable
To next bridge
From previous bridge
CAT5 Cable
CAT5 Cable
LUMINAIRE MOUNTING - LAY-IN CEILING
NTS
LUMINAIRE
SUSPENSION
WIRES REFER TO
SPECIFICATION
SECTION
26 51 00
3 TWIST
MINIMUM
(TYP)
FIXTURE WHIP FROM
JUNCTION BOX
(1829mm (6') LONG
MAX.)
LUMINAIRE.
REFER TO
SCHEDULE
LUMINAIRE MANUFACTURER'S
MOUNTING
HARDWARE
REFER TO SPECIFICATION SECTION 26
51 00
ACOUSTICAL CEILING
TILE
(TYP)
ARCHITECTURAL
CEILING GRID
LUMINAIRE.
REFER TO
SCHEDULE
GENERAL NOTE:
1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING INSTRUCTIONS AND USING
THE RECOMMENDED MOUNTING HARDWARE.
WALL
PHONE
6"
WALL
JOIST
8'-0"
18"
4'-0"
LIGHT
SWITCHES
3"
TSTAT/SENSOR
OR
ANNUNCIATOR
EXIT
RECEPTACLE
6'-6" TO
TOP OF
MCB
ELEC.
PANEL
1'-0"
FLOOR
CEILING
DETAIL NOTES :
1. COORDINATE ALL LOCATIONS OF ELECTRICAL EQUIPMENT WITH ARCHITECTURAL
DRAWINGS.
2. USE THESE DEVICE MOUNTING HEIGHTS UNLESS OTHERWISE INDICATED ON ARCHITECTURAL
DRAWINGS.
3. DEVICE HEIGHTS SHOWN FOR INFORMATIONAL PURPOSES ONLY. HEIGHTS APPLY FOR INSTALLED DEVICES AND
EQUIPMENT.
RECEPTACLE(S)
VOICE/DATA JACKS
AND JBOXES CENTER
BETWEEN JOISTS
44" MAX
STANDARD MOUNTING HEIGHTS
NTS
TYPICAL DUAL OUTPUT DIMMING ROOM CONTROLLER DETAIL
NTS
TYPICAL DUAL OUTPUT ON/OFF ROOM CONTROLLER DETAIL
NTS
CEILING
FLOOR
SIDE
WALL
4"
4"
NOTE:
MEASUREMENTS ARE
SHOWN TO THE
CLOSEST EDGE OF
THE DETECTOR
HEAT DETECTORS
NEVER IN SHADED
AREA
WALL MOUNTED
SMOKE/HEAT
DETECTOR
CEILING MOUNTED
SMOKE/HEAT
DETECTOR
12"
MAX
3'
MIN
HVAC SUPPLY OR
RETURN DIFFUSER
MAGNETIC DOOR
HOLDER
FIRE
PULL
TO EXIT DOOR
5' MAX
MANUAL PULL
STATION
48" MAX
MEASUREMENT
SHOWN TO TOP
OF PULL HANDLE
NFPA 72 AUDIBLE APPLIANCE,
6" MIN BELOW FINISHED CEILING
/ 90" MIN AFF. (OTHER
MOUNTING HEIGHTS SHALL BE
PERMITTED BY THE AHJ
PROVIDING IT MEETS THE SOUND
LEVEL OUTPUT REQUIRED.
AUDIBLE
ONLY
FOR CEILING HEIGHTSLESS THAN 86". THE
VISUAL LENS MOUNTINGHEIGHT SHALL BE
WITHIN 6" OF THE CEILING
AUDIBLE/VISUAL & VISUAL
ONLY APPLIANCES
SYNCHRONIZE MORE THAN
TWO APPLIANCES IN ANY
FIELD OF VIEW
REF. 80" MIN (IBC)
REF. 96" MAX (IBC)
ABOVE FINISHED
FLOOR
NOTE:
REFER TO THE PROPER
DEVICES INSTALLATION
INSTRUCTIONS FOR
BACKBOX MOUNTING
HEIGHT
96" MAX
(NFPA ADA)
ABOVE
FINISHED FLOOR
TO TOP OF LENS
FIRE ALARM STANDARD MOUNTING DETAIL
NTS
DOOR WIDTH LESS THAN 3"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
C U s e rs
\b z h a n g .A
C E
L A
\O n e
D ri v e
A c e la A rc h it e c ts
E n g in e e rs P
.C \D o c u m e n ts \2
-U
S D
V A
-0 M
E P b z h a n g
Y D
J Q
.r v t
/1
/2
:4
:4
A
M
E301
ELECTRICAL DETAILS
6/18/2021 DJW ACELA
EAST ORANGE VAMC 385 TREMONT AVE, EAST ORANGE, NJ
Revisions: Date: Page 42 of 43
208V 3PH 30A
EP6 7-9-11
PANEL
DESIGNATION
SPECIAL PURPOSE
POWER RECEPTACLE
AS REQUIRED. PRIOR
TO WORK, CONFIRM
FINAL RECEPTACLE
REQUIREMENTS WITH
OWNER'S END USER
120 VAC POWER
RECEPTACLE
AS REQUIRED.
SEE NOTE 1.
VOLTAGE PHASE
EP6 16
CIRCUIT
NUMBER(S)
3/16" HEIGHT
LETTERING (TYP)
PANEL
DESIGNATION
CIRCUIT
NUMBER(S)
AMPACITY
DEVICE COVER
PLATE AS
REQUIRED
DEVICE COVER
PLATE AS
REQUIRED
CONTROL DEVICE
(SWITCH,DIMMER,ETC.)
AS REQUIRED.
DEVICE COVER
PLATE AS
REQUIRED
DETAIL NOTES :
1. ALL WIRING DEVICES SHALL BE FLUSH-MOUNTED (IN ALL FINISHED
SPACES) IN THE VERTICAL POSITION (WHERE POSSIBLE) IN A
CODE COMPLIANT ROUGH-IN BOX AS REQUIRED. EXAMPLES
SHOWN ABOVE SHALL APPLY TO ALL WIRING DEVICE PROVISIONS.
2. ALL VERTICALLY-MOUNTED STANDARD 120V SINGLE AND DUPLEX
POWER RECEPTACLES SHALL BE INSTALLED "GROUND DOWN".
3. PROVIDE A DETAILED PRODUCT SHOP DRAWING SUBMITTAL
(INCLUDING FINISH OPTIONS FOR ALL COMPONENTS) FOR
REVIEW/SELECTION BY THE ENGINEER AND ARCHITECT.
DAT 7-9-11
TEL 7-9-11
COORDINATED
DESIGNATION LABEL
COORDINATED
DESIGNATION LABEL
DEVICE COVER
PLATE AS
REQUIRED
TELE/DATA JACK
AS REQUIRED. CONFIRM
FINAL JACK REQUIREMENTS
AND CONFIGURATION WITH
OWNER'S END USER. BASE
ACCORDINGLY
TYPICAL FLUSH-MOUNTED WIRING DEVICES
NTS
TYPICAL WALL VACANCY SWITCH DETAIL
NTS
BUTTON 1
(TEST BUTTON)
COVER RELEASE
CATCH
PHOTOCELL
PUSH BUTTON
LINE
CIRCUIT
BLACK
LOAD
RED
GROUND
CONNECTION
BUTTON A
(TEST BUTTON)
COVER RELEASE
CATCH
PHOTOCELL
PUSH BUTTON
LINE
CIRCUIT
BLACK
LOAD 1
RED
GROUND
CONNECTION
LOAD 2
BLUE
BUTTON B
NEUTRAL
WHITE
BUTTON A
(RAISE BUTTON)
BUTTON B
(ON/OFF BUTTON)
BUTTON C
(LOWER BUTTON)
COVER RELEASE
CATCH
PHOTOCELL
PUSH BUTTON
NEUTRAL
WHITE
LINE
CIRCUIT
BLACK
DIMMING
FIXTURE
RED
VIOLET
GRAY
GROUND
CONNECTION
TYPICAL WALL DIMMING VACANCY SWITCH DETAIL
NTS
ELECTROMAGNETIC DOOR HOLDER WIRING DETAIL
NTS
24-60 optimal
Operation Narrative
Doors are to be normally held open. the electromagnetic door releases will be energized with the voltage shown
(at right) in the hardware set for this opening. Power shall be controlled by the fire control system. it will interrupt the power if alarmed, causing the doors to be released, thus allowing the door closers to close the doors. When power is restored the magnets will re-energize, permitting the doors to be manually returned to their held open position.
Fire Alarm Panel 24VAC Output
COM
24 VAC/DC
120 VAC
12 VDC
COM
24 VAC/DC
120 VAC
12 VDC
COM
24 VAC/DC
120 VAC
12 VDC
Fire Alarm Panel 24VDC Output
Fire Alarm Panel 12VDC Output
Fire Alarm Panel
120VAC
Output
COM
HOT
GND
COM
24 VAC/DC
120 VAC
12 VDC
Ground to Screw on Mounting Bracket
Electrical Specifications:
12VDC @ .O40 AMPS
24VAC/DC @ .020
AMPS
120VAC @ .020 AMPS
(or see specific model)
NOTE: All wiring must be installed in compliance with the National Electrical Code and the local codes having jurisdiction. Proper wire gauge should be used.
24 VAC WIRING
24 VDC WIRING
12 VDC WIRING
Electromagnetic Door Release
Power Supply/ Junction BoxB
A
C
C
B
Local Detector
To Fire Control System Power
120 VAC WIRING
A A
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
C U s e rs
\b z h a n g .A
C E
L A
\O n e
D ri v e
A c e la A rc h it e c ts
E n g in e e rs P
.C \D o c u m e n ts \2
-U
S D
V A
-0 M
E P b z h a n g
Y D
J Q
.r v t
/1
/2
:4
:4
A
M
E302
ELECTRICAL DETAILS
6/18/2021 DJW ACELA
EAST ORANGE VAMC 385 TREMONT AVE, EAST ORANGE, NJ
Revisions: Date: Page 43 of 43
File details come from the government source that posted it. Updated .