620-21-203 Revised Drawing.pdf

PDF 342 KB Posted

Attached to
Y1DZ--Montrose Outdoor Basketball Court
Solicitation number
36C24221Q1247
Issued by

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

SP-1

SITE PLAN

DESIGN DEVELOPMENT

CAMPUS SIDEWALKS

REPAIR

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

A/E firm name A/E firm street address A/E firm city, state, zip code A/E firm phone number A/E firm POC engineering discipline <EDIT TEXT>:

Consultant firm name Consultant firm street address Consultant firm city, state, zip code Consultant firm phone number Consultant POC

MONTROSE, NEW YORK

Project Director

-- --- KAM

Revisions: Date:

STAMP

Sheet 3 of 4

620-21-203

L:

\E

N G

\A ut oC

AD

P ro je ct

F ile s\ Pr oj ec t F ile s\

\F

D R

\6

-2 0-

C am pu s

Si de w al ks \D

ES

IG

N

NEW OUTDOOR

BASKETBALL COURT FOR

RESIDENT ACTIVITIES

AutoCAD SHX Text

FUEL TANK

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

EXISTING TREE TO REMAIN

AutoCAD SHX Text 4"

AutoCAD SHX Text 4"

AutoCAD SHX Text

EXISTING UNDERGROUND WATER LINES TO REMAIN

AutoCAD SHX Text

EXISTING OVERHEAD DUCTWORK TO REMAIN

AutoCAD SHX Text

EXISTING UNDERGROUND DRAINAGE PIPES TO REMAIN

AutoCAD SHX Text

EXISTING UNDERGROUND ELECTRICAL LINES TO REMAIN

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

PROPOSED BASKETBALL COURT

AutoCAD SHX Text

AutoCAD SHX Text 1 inch = 20 ft.

AutoCAD SHX Text

( IN FEET )

AutoCAD SHX Text

GRAPHIC SCALE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text N

AutoCAD SHX Text GENERAL NOTES: 1. THE CONTRACTOR IS TO PROVIDE PERSONAL PROTECTIVE EQUIPMENT COMPLIANT WITH THE CONTRACTOR IS TO PROVIDE PERSONAL PROTECTIVE EQUIPMENT COMPLIANT WITH OSHA REGULATIONS TO EACH EMPLOYEE WORKING ON SITE AT ALL TIMES. 2. THE CONTRACTOR IS TO OBTAIN A UTILITY MARKOUT PRIOR TO ANY DIGGING BY HAND THE CONTRACTOR IS TO OBTAIN A UTILITY MARKOUT PRIOR TO ANY DIGGING BY HAND OR MACHINE. 3. ANY DISTURBED SOIL REMAINING AFTER CONCRETE WORK IS COMPLETE IS TO BE ANY DISTURBED SOIL REMAINING AFTER CONCRETE WORK IS COMPLETE IS TO BE STABILIZED WITH EITHER HAY AND SEED, OR APPROVED EQUAL. 4. LOCATION OF COURT SUBJECT TO MOVE WITHIN COURTYARD AREA AS PER COR LOCATION OF COURT SUBJECT TO MOVE WITHIN COURTYARD AREA AS PER COR DIRECTION

AutoCAD SHX Text

%%ULEGEND

AutoCAD SHX Text

EXISTING OVERHEAD DUCTS

AutoCAD SHX Text

EXISTING UNDERGROUND ELECTRICAL LINES

AutoCAD SHX Text

EXISTING UNDERGROUND DRAINAGE PIPE

AutoCAD SHX Text

EXISTING UNDERGROUND WATER SUPPLY

AutoCAD SHX Text

AutoCAD SHX Text

EXISTING 2' CONTOUR

AutoCAD SHX Text

AutoCAD SHX Text

PROPOSED 2' CONTOUR

AutoCAD SHX Text

PROPOSED SILT FENCE