This document includes details for a federal contract solicitation to renovate the third and fourth floors of D Wing at the Syracuse VA Medical Center. The solicitation is a total service-disabled veteran owned small business set aside being conducted according to Public Law 109-461. Offerors must be verified on VetBiz.gov and registered on SAM.gov under NAICS code 236220 to be considered. They must submit their annual Vets-100 report and a supplier qualifier report may be requested. A site visit is scheduled for January 13, 2021 and questions are due by January 28, 2021. The contract will be awarded to the responsive, responsible bidder submitting the lowest price in accordance with the requirements. The architect that designed the project cannot be awarded the construction contract. Bids are due by email to the contracting officer with the specified subject line by the deadline.
View the file
Other files for this federal contract opportunity
Show all 35
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ENGINEERING LLP
www.fellp.com
181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704 fx 855-320-8735
22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481 fx 845-343-4986
FE PROJECT #: 19-083
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
VA MEDICAL CENTER SYRACUSE
3RD & 4TH FLOOR 'D' WING
RENOVATIONS
VAMC, SYRACUSE, NY
528A7-19-708
Project Director
10-21-20Revisions: Date:
Fi le
N am e:
F
:\2
9\
-0
V A
S Y
R A
C U
S E rd th F lo or
D W in g\
(1 ) T
S .d w g
(L ay ou t:
(1
)T S
D at e:
F ri, N ov
0,
- 2
:1
P M
N am e:
z r)
HYMAN
HAYES
ASSOCIATES
6 Wembley Court
Albany, NY 12205
(518) 452-3470 www.hymanhayes.com
ARCHITECT:
TS
TITLE SHEET WITH INDEX TO
DRAWINGS
REF.
A B BB C
HOOD
HOOD
CONF.
D325OFFICE
D323A
OFFICE
D323B
SWING SPACE
D321
SWING SPACE
D305 SWING SPACE
D304
D301
JAN. (E)
OFFICE
D308
LAB
D311
OFFICE
D323
OFFICE
D324
LAB
D314
Room D313A
Room D313B
HOT/COLD PROCESSING
D313
CORRIDOR
D300A
ELEC.
D310
FIRE APP.
D312
BLS-3 ANTE ROOM
D307
BLS-3 LAB
D307A
CORRIDOR
D300
TOILET
D303
STORAGE
D320
OFFICE
D322
ELEC.
D306
A B BB C
OFFICE
D425
OFFICE
D423
OFFICE
D421
OFFICE
D411A
SCI / RESEARCH LAB
D407
SCI PROCEDURE RM
D405
TOILET (E)
D412
BREAK ROOM
D408
SOILED UTILITY
D402
TOILET
D401
MECHANICAL
D417
STORAGE
D404
LARGE EXAM
C429
HOME
CARE
NURSE
CUBICLES (4)
D426
OFFICE
D419
EXAM
C426
EXAM
C428
LARGE EXAM
C423
HOME CARE NURSE
C432
EXAM
C430
LARGE EXAM
C434
JAN. (E)
D406
CUBICLES
D415
CONF. ROOM
D409
OFFICE
D411C
OFFICE
D411B
CORRIDOR
D432
CORRIDOR
D432A
STORAGE
C441A
TELEHEALTH
C420
ENGINEERING LLP
www.fellp.com
181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704 fx 855-320-8735
22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481 fx 845-343-4986
FE PROJECT #: 19-083
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
VA MEDICAL CENTER SYRACUSE
3RD & 4TH FLOOR 'D' WING
RENOVATIONS
VAMC, SYRACUSE, NY
528A7-19-708
Project Director
10-21-20Revisions: Date:
Fi le
N am e:
F
:\2
9\
-0
V A
S Y
R A
C U
S E rd th F lo or
D W in g\
(2 ) 1
-G I-0
.d w g
(L ay ou t:
(2
) 1 -G
I-0
D at e:
F ri, D ec
4,
- 1
1:
A
N am e:
z r)
HYMAN
HAYES
ASSOCIATES
6 Wembley Court
Albany, NY 12205
(518) 452-3470 www.hymanhayes.com
ARCHITECT:
UL U465 (2 HOUR RATED)
FIRECODE 'X' GYPSUM BD PANELS
APPLIED VERTICALLY OR HORIZONTALLY.
HORIZONTAL JOINTS NEED NOT BE
STAGGERED. FACE LAYER JOINTS TO BE
FINISHED. FIRE CAULK ALL
PENETRATIONS. PROVIDE 4' DOORS WITH
2 HOUR RATING AS REQUIRED.
3RD FLOOR ICRA PLAN1 4TH FLOOR ICRA PLAN2
CONSTRUCTION PARTITION WALL DETAIL3
1-GI-001
3RD & 4TH FLOOR 'D' WING
ICRA PLANS
KEYED NOTES:
NOTES:
A B C
C453 C451 C449
C447
C445 C443 C441A C424
C441
C426
C428
C430
C432
C434
C429
C423
C425
C422
C420
C444C446C448C450C452C454 D408
C427
C461D400
D402
D406
D401
D404D405
D407
D409
D415
D417
D416
D412
D410
4S6
CORRIDOR 445
M305F
C
7 6 5 4 3 2 1
A B
C
D3
A D3
B
D3
D3
D3
D3
D3
D3
D3
D3
D3
C4
D3
C4
D3
D3
D3
D3
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
SCHEMATIC DESIGN
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
VA MEDICAL CENTER SYRACUSE
3RD & 4TH FLOOR 'D' WING
RENOVATIONS
VAMC, SYRACUSE, NY
528A7-19-708
10/21/2020
Egan Environmental Consulting, Inc.
TGE EDS
Drawing 01 OF 01
C :\T em p\
R ev it Fi le s\
S yr ac us e V
A D
W in g R en ov at io ns _m pa tte rs on
C 5J
.rv t 3/
5/
1:
:2
A M
1-HA-101
THIRD & FOURTH FLOOR
ASBESTOS ABATEMENT PLAN
SCALE: 1/8" = 1'-0"
2 4TH FLOOR ASBESTOS ABATEMENT PLAN
PROJECT
NORTH
KEY PLAN- 4TH FLOOR
SCALE: 1/8" = 1'-0"1-HA-101
1 3RD FLOOR ASBESTOS ABATEMENT PLAN
PROJECT
NORTH
PROJECT
NORTH
3rd & 4th FLOOR ASBESTOS ABATEMENT TO BE COMPLETED PRIOR TO
START OF CONSTRUCTION. PROPOSED WORK TO BE BASED ON TESTING
REPORT. COORDINATE ALL DEMOLITION WORK WITH ASBESTOS REPORT
RESULTS AND ABATEMENT SCOPE.
Revisions: Date:
1-HA-101
A B BB C
C426
C428
C430
C432
C434
C429
C423
D408
C427
C461 D406
D404D405
D407
D409
D415
D417
D416
D412
D410
4S6
VERIFY EXITING WALLS BUILT ON CONCRETE SUBFLOOR TOPPING;
REPORT TO ARCHITECT IF EXISTING WALL IS FOUND TO BE CONSTRUCTED
ON TOP OF DECKING (TYPICAL)
FEC
CONTRACTOR TO DEMOLISH CHASE
IN ITS ENTIRERTY TO ALLOW
ACCESS FOR POTENTIAL
ENVIRONMENTAL CONTAMINANTS
TO BE REMOVED
CONTRACTOR TO DEMOLISH CHASE
IN ITS ENTIRERTY TO ALLOW
ACCESS FOR POTENTIAL
ENVIRONMENTAL CONTAMINANTS
TO BE REMOVED
D414
D416
ASSUMED METAL HAT CHANNEL W/
GWB WALL FINISH. REMOVE &
DISPOSE TO ALLOW FOR PROPOSED
INSTALLATION OF RIGID INSULATION
& METAL FRAMING
NO EXISTING FLOORING
FEC
C420
TELEHEALTH
NO EXISTING FLOORING
D401
D400D404
CONTRACTOR TO DEMOLISH CHASE
IN ITS ENTIRERTY TO ALLOW
ACCESS FOR POTENTIAL
ENVIRONMENTAL CONTAMINANTS
TO BE REMOVED
CONTRACTOR TO DEMOLISH CHASE
IN ITS ENTIRERTY TO ALLOW
ACCESS FOR POTENTIAL
ENVIRONMENTAL CONTAMINANTS
TO BE REMOVED
CONTRACTOR TO DEMOLISH CHASE
IN ITS ENTIRERTY TO ALLOW
ACCESS FOR POTENTIAL
ENVIRONMENTAL CONTAMINANTS
TO BE REMOVED
DEMOLITION LEGEND:
EXISTING DOOR TO REMAIN
PARTITION TO BE REMOVED
DOOR AND FRAME TO BE REMOVED
PLUMBING FIXTURE TO REMAIN
PLUMBING FIXTURE TO BE REMOVED
EXISTING WALL TO REMAIN
AREA NOT HATCHED INDICATES REMOVAL OF ALL
ITEMS INCLUDING, BUT NOT LIMITED TO PARTITIONS,
VINYL WALL COVERINGS, ALL FINISH FLOOR
MATERIALS, WALL BASE AND ASSOCIATED
ADHESIVES AND MASTICS, FLOOR ACCESS PANELS,
FLOOR DRAINS, BORROWED LITES, WALL
PROTECTION, CERAMIC TILE, MILLWORK, CASEWORK,
LOCKERS, BENCHES, SHELVING, AND STANDARDS,
WHITEBOARDS, BULLETIN BOARDS, LIGHT FIXTURES,
GYPSUM BOARD CEILINGS AND SOFFITS, SUSPENDED
CEILING SYSTEMS, DIFFUSERS, GRILLES, COAT
RACKS, PRIVACY CURTAINS AND TRACKS, PLUMBING
FIXTURES, TOILET ACCESSORIES, WALL BUMPERS,
CHAIR RAILS, TV AND BRACKETS, SHARPS BOXES,
ZONE VALVE BOXES, ANESTHESIA COLUMNS, GLOVE
BOXES, CLOCKS, HAND SANITIZER DISPENSERS,
PNEUMATIC TUBE STATIONS, SURGICAL BOOMS,
PRECISION AIR DIFFUSER SYSTEMS.
COORDINATE DUCTWORK, ELECTRICAL AND ALL
MEDICAL GAS SYSTEM REMOVALS WITH MEP
ENGINEER. COORDINATE WITH OWNER FOR THE
ITEMS THAT REQUIRE SALVAGING. COORDINATE
STORAGE OF SALVAGED ITEMS WITH OWNER'S
REPRESENTATIVE.
EXISTING AREA TO REMAIN
(NOT IN CONTRACT)
XXXX DOOR TO BE REMOVED AND
SALVAGED FOR RELOCATION
A B BB C
D323B D323A
D323
D325
D324
D321
D304D305
D308
D311
D314D313
D306
D312
T
SPILL CONTROL
STATION
FPS
COORDINATE COLD UNIT
COMPRESSOR RELOCATION
W/ MEP DOCUMENTS
D310
DEMOLITION NOTES
1. DRAWINGS SHOW GENERAL SCOPE OF REMOVAL WORK. CONTRACTOR IS REQUIRED TO
VISIT SITE TO CONFIRM EXACT ITEMS AND MATERIALS TO BE REMOVED.
2. CONTRACTOR IS TO PROVIDE ALL DEMOLITION WORK AS REQUIRED TO ALLOW FOR
INSTALLATION OF NEW WORK AS SHOWN ON DRAWINGS.
3. PROVIDE NEW OPENINGS IN EXISTING CONSTRUCTION. REMOVE ONLY AS MUCH
EXISTING CONSTRUCTION AS REQUIRED TO PROVIDE NEW OPENING. COORDINATE SIZE
OF OPENING WITH FLOOR PLAN
4. COORDINATE ACTUAL SIZE, LOCATION AND EXTENT OF FLOOR SLAB REMOVAL WITH
MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS. SAW CUT CONCRETE SLAB.
JACKHAMMERS ARE NOT ALLOWED.
5. REMOVE EXISTING FLOORING IN AREAS OF NEW WORK IN THEIR ENTIRETY TO ALLOW
FOR SMOOTH SUBSTRATE FOR NEW FLOORING.
6. SHORE EXISTING CONSTRUCTION AS REQUIRED FOR DEMOLITION AND REMOVALS.
7. REMOVE DEBRIS FROM DEMOLITION AREA AS IT IS PRODUCED. LEGALLY DISPOSE OF
MATERIALS OFF SITE.
8. PROMPTLY REPAIR ADJACENT SURFACES DAMAGED BY THE DEMOLITION.
9. ALL DOORS, EQUIPMENT, FIXTURES, REGISTERS AND OTHER ITEMS REMOVED DURING
DEMOLITION ARE TO REMAIN THE PROPERTY OF THE OWNER UNLESS OTHERWISE
DIRECTED BY THE OWNER'S REPRESENTATIVE.
10. REUSE ITEMS REMOVED AS INDICATED ON DRAWINGS OR AS DIRECTED BY OWNER.
11. REMOVE ALL EXISTING EXPOSED OR CONCEALED CONDUIT, WIRING INSTALLATION,
WIRING DEVICES, ELECTRICAL EQUIPMENT, PIPING, DUCTWORK, AND EQUIPMENT
RENDERED OBSOLETE BY THE DEMOLITION OR ALTERATION. REMOVE PIPING TO THE
NEAREST MAIN.
12. RESTORE ANY EXISTING ELECTRICAL INSTALLATION DISTURBED DURING THE COURSE
OF CONSTRUCTION AND NOT INDICATED FOR REMOVAL.
13. ALL EXTERIOR DOORS AND WINDOWS TO REMAIN, UNLESS OTHERWISE INDICATED.
14. PROVIDE FIRE SAFING AND FIRESTOP SEALANT ALL PIPING AND CONDUIT REMOVALS AS
REQUIRED TO MAINTAIN WALL/ FLOOR RATINGS.
15. CAREFULLY REMOVE PARTITIONS AROUND COLUMNS AND AT PARTITIONS TO REMAIN.
TO AVOID DAMAGING COLUMNS AND MINIMIZE DAMAGE TO CONSTRUCTION TO REMAIN.
16. PRIOR TO DEMOLITION NOTIFY OWNER OF ALL FIXTURES, DEVICES, ETC. TO BE
DISCARDED AND SET ASIDE THOSE THE OWNER WANTS TO SALVAGE.
HYMAN
HAYES
ASSOCIATES
6 Wembley Court, Albany, NY 12205
(518) 452-3470 www.hymanhayes.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ARCHITECT:
VA MEDICAL CENTER SYRACUSE
3RD & 4TH fOOR 'D' WING
RENOVATIONS
VAMC, SYRACUSE, NY
528A7-19-708
10/21/20
C T e m p \R e v it F ile s \S y ra c u s e
V A
D W in g
R e n o v a ti o n s m p a tt e rs o n
C J
.r v t
/2
/2
:1
:2
P
M
1-AD-101
THIRD & FOURTH FLOOR
DEMOLITION PLAN
SCALE: 1/8" = 1'-0"1-AD-101
2 4TH FLOOR DEMOLITION PLAN
PROJECT
NORTH
KEY PLAN- 4TH FLOOR
SCALE: 1/8" = 1'-0"1-AD-101
1 3RD FLOOR DEMOLITION PLAN
PROJECT
NORTH
PROJECT
NORTH
1 COORDINATE EXISTING PLUMBING FIXTURE W/ ASBESTOS
REMOVALS; VERIFY EXTENT OF ALL PLUMBING REMOVALS
WITH PLUMBING DOCUMENTS.
2 REMOVE AND DISPOSE OF EXISTING CASEWORK;
COUNTERTOPS WILL BE REMOVED BY OTHERS PRIOR TO
START OF CONSTRUCTION
3 REMOVE AND DISPOSE OF EXISTING SOLID SURFACE WINDOW
SILL AND APRON
4 REMOVE AND DISPOSE OF ALL PLUMBING FIXTURES AND
ASSOCIATED PLUMBING; VERIFY EXTENT OF ALL REMOVALS
WITH PLUMBING DOCUMENTS
5 REMOVE AND DISPOSE OF EXISTING 4" MASONRY INTERIOR
WALL TO ALLOW FOR PROPOSED CONSTRUCTION
6 REMOVE AND DISPOSE OF EXISTING DOOR AND FRAME TO
ALLOW FOR PROPOSED CONSTRUCTION
8 REMOVE AND DISPOSE OF ALL EXISTING FINISHED FLOORING,
WALL BASE & ADHESIVES TO CONCRETE SLAB
9 REMOVE AND DISPOSE OF EXISTING SUSPENDED CEILING
SYSTEM TO ALLOW FOR PROPOSED CONSTRUCTION
10 REMOVE AND DISPOSE OF EXISTING METAL PARTITION
SYSTEMS TO ALLOW FOR PROPOSED CONSTRUCTION
11 REMOVE AND DISPOSE OF EXISTING WALL MOUNTED
PLUMBING FIXTURES, PATCH EXISTING WALL TO ALLOW FOR A
SMOOTH EVEN SURFACE TO MATCH EXISTING ADJACENT
CONDITIONS
12 REMOVE EXISTING WALL PROTECTION/WALL TILE TO ALLOW
FOR A SMOOTH & CLEAN SURFACE FOR PROPOSED
CONSTRUCTION (TYP.) OF ENTIRE ROOM
13 REMOVE AND SALVAGE EXISTING METAL LOCKER SYSTEM TO
ALLOW FOR PROPOSED REINSTALLATION; COORDINATE WITH
PROPOSED CONSTRUCTION
14 DISASSEMBLE EXISTING HOT/COLD UNITS & ASSOCIATED
PLUMBING/ELECTRICAL AS NEEDED TO ALLOW FOR SALVAGE
AND RELOCATION; COORDINATE ALL PLUMBING & ELECTRICAL
REMOVALS WITH M.E.P. DRAWINGS.
15 REMOVE AND DISPOSE OF EXISTING WALL MOUNTED SHELVING
TO ALLOW FOR PROPOSED CONSTRUCTION
16 REMOVE AND DISPOSE OF EXISTING DOOR, FRAME & METAL
FRAMING W/ GWB SHEATHING AS NEEDED TO ALLOW FOR
PROPOSED CONSTRUCTION
7 REMOVE AND DISPOSE OF EXISTING METAL FRAMING W/ GWB
SHEATHING EA. SIDE TO ALLOW FOR PROPOSED
CONSTRUCTION
17 REMOVE AND DISPOSE OF EXISTING 2X4 SUSPENDED CEILING
SYSTEM AS NEEDED TO ALLOW FOR PROPOSED
CONSTRUCTION. COORDINATE W/ SHEET A3.01 PRIOR TO
DEMOLITION.
KEY NOTES
THIRD FLOOR ASBESTOS ABATEMENT TO BE COMPLETED PRIOR TO
START OF CONSTRUCTION. PROPOSED WORK TO BE BASED ON TESTING
REPORT. COORDINATE ALL DEMOLITION WORK WITH ASBESTOS REPORT
RESULTS AND ABATEMENT SCOPE.
FOURTH FLOOR ASBESTOS ABATEMENT TO BE COMPLETED PRIOR TO
START OF CONSTRUCTION. PROPOSED WORK TO BE BASED ON TESTING
REPORT. COORDINATE ALL DEMOLITION WORK WITH ASBESTOS REPORT
RESULTS AND ABATEMENT SCOPE.
18 COORDINATE REMOVE AND DISPOSE OF ALL EXISTING
FINISHED FLOORING & WALL BASE W/ ASBESTOS REMOVALS
REMOVE & DISPOSE OF ALL WALL ADHERED
ACOUSTICAL PANELS & ADHESIVE TO CMU WALL. CMU
WALL TO BE CLEAN & SMOOTH TO ALLOW FOR
PROPOSED PRIMER & PAINT FINISH. (TYP.)
19 COORDINATE REMOVE AND DISPOSE OF ALL EXISTING FRP
WALL COVERINGS AND ADHESIVES TO ALLOW FOR PROPOSED
CONSTRUCTION
EXISTING 3RD FLOOR DOORS TO BE REMOVED BY ASBESTOS
CONTRACTOR. ALL EXISTING METAL DOOR FRAMES @ MASONRY WALLS
TO REMAIN.
EXISTING 4TH FLOOR DOORS TO BE REMOVED BY ASBESTOS
CONTRACTOR. ALL EXISTING METAL DOOR FRAMES @ MASONRY WALLS
TO REMAIN. ALL FRAMES TO BE REMOVED AT EXISTING WALLS DESIGNED
TO BE REMOVED.
1 - ADDENDUM 2 Date1-28-21
ALIGN
CODE
ACCESSORY LEGEND
ITEM
PROVIDED BY
O = OWNER/ C = CONTRACTOR
INSTALLED BY
MODEL NUMBER
OCODE BLUECB O SEE SPECS
CCLOTHING HOOKCH C SEE SPECS
GRAB BARGB SEE SPECS
OHAND SANITIZER DISPENSERHSD SEE SPECS
OLIQUID SOAP DISPENSERLSD C SEE SPECS
CMIRRORMR C SEE SPECS
ONURSE CALLNC C SEE SPECS
OPAPER TOWEL DISPENSERPTD C SEE SPECS
OSANITARY NAPKIN DISPOSALSND C SEE SPECS
C C
C
OTOILE TISSUE DISPENSERTTH C SEE SPECS
OWASTE BASKET WB O SEE SPECS
FEC SIGNAGE
H T
TEL/
DATA
TWIST LOCK
RECEPTACLE
RECEPTACLE
'-6
'-0
DOOR
ACTUATOR
LIGHTING
SWITCHES
HUMIDISTAT
THERMOSTAT
ALARM
PANEL
FIRE HOSE
CABINET (FHC)
'-0
'-0
'-0
ZONE VALVE BOXES
Z.V. Z.V.
ELECTRIC
PANEL (E.P.)
'-6
'-0
FEC
'-6
" A T
S T
A F
F /D
U T
Y S
T A
T
IO
N S
'-9
NURSE
CALL
NC
'-0
'-1
CH
'-4
SHARPS BOX
PTD
'-2
LSD
'-6
SND
'-3
'-0
HOLDER OUTLET
AND TOP EDGE
OF DISPOSAL
TYPICAL MOUNTING HEIGHTS, EXCLUDES
TOILET ROOMS UNLESS OTHERWISE NOTED.
SOFFIT
3" LIGHT VALANCE,
AS INDICATED
COUNTERTOP AND
BACKSPLASH AS
INDICATED
SINK AND FAUCET -
SEE PLUMBING
DRAWINGS
DOOR SWING
WALL BASE
ADJUSTABLE SHELVES ON BRACKETS
STANDARDS
RECEPTACLE - COORDINATE WITH
ELECTRICAL DRAWINGS
WORK SURFACE
FABRIC WRAPPED TACK PANEL, AS INDICATED
BACKSPLASH, AS INDICATED
METAL
SUPPORT
BRACKET
WALL CABINET
CABINET
MICROWAVE
OPEN
WALL CABINET
WALL SHELVES
ADJUSTABLE
COUNTER/ SINK BASE CABINET
(1) DRAWER
BASE CABINET/ BASE CABINET
(4) DRAWER
BASE CABINET/
W/ BACKSPLASH
WORKSURFACE
NOTE:
CABINET TYPE LEGEND GRAPHICALLY DENOTES MILLWORK
TYPES FOUND IN INTERIOR ELEVATIONS. SEE 1-AS-701
DRAWING SERIES FOR CORRESPONDING MILLWORK
SECTIONS.
DOOR PULLS
V A
R
IE
S
C O
U N
T E
R H
E
IG
H T
SLOPED TOP, AS
INDICATED
OPEN
U .N
.O
MICROWAVE
SINK APRON
NOTE:
ELEVATION IS FOR GENERIC HEIGHTS & LOCATIONS. NOT
ALL OF THE ELEMENTS SHOWN ARE PROVIDED ON THE
CONTRACT DOCUMENTS
GENERAL NOTES
1. ALL WORK SHALL COMPLY WITH ALL APPLICABLE GOVERNMENT CODES INCLUDING BUT
NOT LIMITED TO OSHA, ADA, AND NFPA.
2. ALL ENTRANCES SHALL COMPLY WITH THE ARCHITECTURAL BARRIERS ACT (ABA)
ACCESSIBILITY STANDARDS.
3. CONTRACTOR IS TO PERFORM A SITE VISIT TO BECOME FAMILIARIZED WITH EXISTING
CONDITIONS BEFORE SUBMITTING PRICING.
4. CONTRACTOR SHALL REVIEW ALL DRAWINGS AND SPECIFICATIONS AND NOTIFY VA COR
OF ANY INACCURACIES PRIOR TO COMMENCEMENT OF WORK.
5. THE CONTRACTOR SHALL HOLD THE OWNER, ARCHITECT AND ENGINEERS HARMLESS
AGAINST ANY AND ALL CLAIMS ARISING FROM WORK PERFORMED ON THE
CONSTRUCTION SITE.
6. COMMENCE WORK IMMEDIATELY UPON AWARD OF THE CONTRACT. PROCEED
DILIGENTLY AND CONTINUOUSLY TO COMPLETION.
7. PRIOR TO STARTING WORK, SUBMIT FOR OWNER'S APPROVAL A DETAILED SCHEDULE
INDICATING ALL WORK THAT MIGHT AFFECT OWNER'S USE OF BUILDING SUCH AS
UTILITY SHUT DOWNS, NOISE GENERATING CONSTRUCTION, ETC.
8. EXISTING FACILITY WILL REMAIN IN OPERATION DURING THIS WORK. ENSURE SAFE
PASSAGE OF ALL PERSONS AROUND WORK AREAS. ERECT BARRIERS AS REQUIRED
AND/OR AS DIRECTED BY OWNER. MAINTAIN ALL REQUIRED EGRESS ROUTES. DO NOT
LIMIT OWNER'S USE OF FACILITY WITHOUT OWNER'S APPROVAL.
9. CONTRACTOR SHALL TAKE PRECAUTIONS TO AVOID ANY DISRUPTION, DAMAGE OR
HAZARD TO OWNER AND OWNER'S CLIENTS DURING CONSTRUCTION. MAINTAIN
BUILDING SECURITY AND PROTECTION FOR OCCUPANTS SAFETY.
10. PATCH FIRE PROTECTION DAMAGED DURING CONSTRUCTION TO RESTORE EXISTING
FIRE RATING.
11. DO NOT INTERRUPT EXISTING UTILITY SERVICE WITHOUT OWNER AUTHORIZATION.
PROVIDE SERVICE DURING INTERRUPTIONS.
12. PERFORM WORK IN A MANNER WHICH MINIMIZES NOISE. SCHEDULE OPERATIONS AS
MAY BE DIRECTED BY OWNER.
13. PROVIDE OWNER WITH TIMELINE SCHEDULE FOR INSTALLATION OF OWNER-PROVIDED,
CONTRACTOR INSTALLED EQUIPMENT.
14. CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIALS REQUIRED TO COMPLETE
THE WORK.
15. PROVIDE ALL MATERIALS AND PERFORM ALL WORK IN ACCORDANCE WITH RECOGNIZED
GOOD STANDARD PRACTICES.
16. ALL MATERIALS SHALL BE AS SPECIFIED, OR AS EQUAL AS APPROVED BY ARCHITECT.
MATERIALS SPECIFIED INDICATE QUALITY INTENT THAT WILL BE USED AS A BASIS FOR
REVIEW OF SUBSTITUTES.
17. ALL ITEMS WHICH ARE NOT SPECIFICALLY REFEREED TO ON THESE DRAWINGS ARE TO
BE SELECTED BY THE OWNER FROM THE MANUFACTURER'S STANDARD SAMPLES
SHOWING FULL RANGE OF TEXTURES AND COLORS AVAILABLE.
18. FOLLOW MANUFACTURER'S SPECIFICATIONS AND INSTRUCTIONS FOR INSTALLATION OF
ALL MATERIALS.
19. SURVEY PROJECT AREA FOR ANY OPENINGS THAT ARE UNSEALED IN FLOORS OR FIRE
BARRIERS OR SMOKE BARRIERS. SEAL ALL PENETRATIONS AS REQUIRED BY PARTITION
TYPE.
20. THE WORDS "PROVIDE" OR "SUPPLY" SHALL INCLUDE BOTH FURNISHING AND
INSTALLING THE SPECIFIED OR DETAILED ITEM, IN PLACE AND READY FOR OPERATION
AND USE.
21. CONTRACTOR SHALL STORE MATERIALS IN OWNER DESIGNATED AREAS. MATERIAL
DELIVERY SHALL BE AS DIRECTED BY OWNER.
22. FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO BEGINNING WORK.
23. ALL DIMENSIONS SHALL BE FIELD VERIFIED. DO NOT SCALE DRAWINGS. INDICATED
DIMENSIONS ARE TO CENTERLINE OF STEEL, FACE OF EXISTING GYPSUM BOARD
PARTITIONS, FACE OF STUDS AT NEW GYPSUM BOARD PARTITIONS OR FACE OF CMU.
24. MINOR ITEMS OF WORK SUCH AS CUTTING, BLOCKING, TRIM, ETC. SHALL BE
PERFORMED AS REQUIRED TO MAKE THE WORK COMPLETE WHETHER SHOWN ON THE
CONTRACT DOCUMENTS OR NOT.
25. PROTECT FINISHED FLOORS AND OTHER SURFACES WITH DURABLE SHEET MATERIALS
FROM TRAFFIC, DIRT, WEAR, DAMAGE OR MOVEMENT OF HEAVY OBJECTS.
26. PRIOR TO DEMOLITION, NOTIFY OWNER OF ALL FIXTURES, DEVICES, ETC. TO BE
DISCARDED AND SET ASIDE THOSE THE OWNER WANTS TO SALVAGE.
27. NOTIFY OWNER OF ALL TELEPHONE, DATA CABLE(S) AND DEVICES INDICATED TO BE
REMOVED OR DISCONNECTED PRIOR TO TAKING ACTION. OWNER MAY OPT TO REMOVE.
ELECTRICAL CONTRACTOR TO REMOVE RACEWAY.
28. USE SUITABLE METHODS TO LIMIT DUST/DIRT FROM ADJACENT SURFACES DIRTIED BY
THE REMOVALS.
29. CONTROL ACCUMULATION OF WASTE MATERIALS AND RUBBISH FROM CONSTRUCTION.
LEAVE PROJECT AREA BROOM CLEAN AT THE END OF EACH DAY. REMOVE ALL DEBRIS
FROM THE SITE IN ACCORDANCE WITH STATE AND LOCAL CODES. COORDINATE
REMOVAL WITH OWNER.
30. PERFORM FINAL CLEANING AT THE END OF THE CONTRACT. CLEAN INTERIOR
SURFACES, EQUIPMENT, FIXTURES AND PLENUMN. REPLACE FILTERS AT MECHANICAL
EQUIPMENT.
31. CONTRACTOR SHALL SECURE AND PAY FOR ALL REQUIRED PERMITS.
5/8" TYPE "X" MMR GYPSUM
WALLBOARD, EACH SIDE
3 1/2" MINERAL WOOL
INSULATION
3 5/8" 20 GA @ 16"
O.C. STEEL STUD
FRAMING. BRACING
@ 4'-0" OC
J08
PARTITION TYPE
SCALE: 1" = 1'-0"
4 1/4"
(5/8" CEMENT BACKER BOARD
@ ALL WALL TILE LOCATIONS)
5/8" TYPE "X" MMR GYPSUM
WALLBOARD, EACH SIDE
3 5/8" x 20 GA @ 16"
O.C. STEEL STUD
FRAMING
3 1/2" MINERAL
WOOL INSULATION
J18
PARTITION TYPE
SCALE: 1" = 1'-0"
STC 46 UL DESIGN No. U465
(WHERE 1 HR.
RATING NOTED)
4 7/8"
5/8" TYPE "X" GYPSUM
WALLBOARD, EACH SIDE
3 5/8" x 20 GA @ 16" O.C.
STEEL STUD FRAMING
3 1/2" MINERAL WOOL
INSULATION
J10
PARTITION TYPE
SCALE: 1" = 1'-0"
STC 46 UL DESIGN No. U465
(WHERE 1 HR.
RATING NOTED)
4 7/8"
5/8" TYPE "X" GYPSUM
WALLBOARD, EACH SIDE
6" x 20 GA @ 16" O.C.
STEEL STUD FRAMING
5 1/2" MINERAL
WOOL INSULATION
L10
PARTITION TYPE
SCALE: 1" = 1'-0" STC 49 UL DESIGN No. U465 (WHERE 1 HR.
RATING NOTED)
7 1/4"
A08
PARTITION TYPE
5/8" TYPE "X" MMR
GYPSUM WALLBOARD,
ONE SIDE
7/8" x 20 GA FURRING HAT
CHANNEL @ 16" O.C.
EXISTING WALL
SCALE: 1" = 1'-0"
1 1/2"
(5/8" CEMENT BACKER BOARD
@ ALL WALL TILE LOCATIONS)
3 5/8" x 20 GA @ 16" O.C.
STEEL STUD FRAMING
(2) LAYERS 5/8" TYPE "X"
MMR GYPSUM WALLBOARD,
EACH SIDE - STAGGER
JOINTS
3 1/2" MINERAL
WOOL INSULATION
J14
PARTITION TYPE
SCALE: 1" = 1'-0" STC 56 UL DESIGN No. U411 (WHERE 2 HR.
RATING NOTED)
6 1/8"
EXISTING CONCRETE DECK
FIRESTOP SEALNT
STEEL TRACK
MECHANICALLY FASTEN
24" O.C. MAX
5/8" TYPE-X
GYPSUM BOARD
3 5/8" STEEL STUD
16" O.C. (SEE PARTITION TYPE FOR STEEL GAGE)
MINERAL WOOL INSULATION
FLEXIBLE SEALANT1
/4
M
IN
/4
M
A X
HEAD OF WALL - 1HR
UL DESIGN: HW-D-0079
UL DESIGN: HW-D-0083
PARTITION - 1HR
UL DESIGN: U465
UL DESIGN: V438
EXISTING CONCRETE DECK
FIRESTOP SEALNT
STEEL TRACK
MECHANICALLY FASTEN
24" O.C. MAX
(2) LAYERS 5/8" TYPE-X
GYPSUM BOARD
3 5/8" STEEL STUD
16" O.C. (SEE PARTITION TYPE FOR STEEL GAGE)
MINERAL WOOL INSULATION
FLEXIBLE SEALANT1
/4
M
IN
/4
M
A X
.HEAD OF WALL - 2HR
UL DESIGN: HW-D-0079
UL DESIGN: HW-D-0083
PARTITION - 2HR
UL DESIGN: U411
UL DESIGN: V438
POLTETHYLENE BACKER
ROD OR MINERAL WOOL
A0
PARTITION TYPE
5/8" TYPE "X" GYPSUM
WALLBOARD, ONE SIDE
1 5/8" x 20 GA @ 16" O.C.
STEEL STUD FURRING
EXISTING WALL
SCALE: 1" = 1'-0"
3 3/4"
1.5" MINERAL FIBER BOARD
INSULATION ADHERED TO EXTERIOR
WALL & TAPED @ ALL JOINTS
(5/8" CEMENT BACKER BOARD
@ ALL WALL TILE LOCATIONS)
FLOOR PLAN LEGEND:
FIRE EXTINGUISHER CABINET
DETAIL/CALLOUT KEY
ROOM TAG
ELEVATION KEY
SECTION KEY
ALIGN KEY
DOOR NUMBER
CORNER GUARD
EXISTING DOOR AND FRAME
NEW DOOR AND FRAME
EXISTING WALL
X
AX.XX
FEC
CG
X
AX.XX
X
AX.XX
NEW PARTITION
FIRE HOSE CABINETFHC
ZONE VALVE BOX. COORDINATE
WITH PLUMBING DRAWINGS.
ZV
MED GAS ALARM PANEL COORDINATE
WITH PLUMBING DRAWINGS.
AP
ELECTRICAL PANEL COORDINATE
WITH ELECTRICAL DRAWINGS.
EP
X
WINDOW TAG/ DESIGNATION
WALL MOUNTED GAS OUTLET
(0-OXYGEN, V-VACUUM, MA-MEDICAL AIR)
AX.XX
HATCH INDICATED AREA NOT IN CONTRACT
XXXX
RELOCATED DOOR
XXXX
Room name
XXXX
DIMENSION TO CENTERLINE OF OBJECT
MR
PTD
'-4
1'-3"
'-1
MIN.
8"
LEG CLEARANCE
11" MIN.
CLEARANCE
9" TOE
'-3
LAVATORY
'-1
'-1
/2
MR
LIQUID SOAP
DISPENSER
LSD
CLEAR KNEE SPACE
TYPICAL MOUNTING HEIGHTS AT TOILET
ROOMS UNLESS OTHERWISE NOTED.
1'-6"
3'-6" 1'-0"
'-1
'-9
'-6
39" TO 41"
3'-0" 6"
TOILET - FLOOR MOUNTED
'-5
'-6
7" TO 9"
'-0
NC
GB
GB
TTH
GB
PVC LAVATORY SHIELD (TYP.)
(PROVIDE VA STANDARD)
HYMAN
HAYES
ASSOCIATES
6 Wembley Court, Albany, NY 12205
(518) 452-3470 www.hymanhayes.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ARCHITECT:
VA MEDICAL CENTER SYRACUSE
3RD & 4TH fOOR 'D' WING
RENOVATIONS
VAMC, SYRACUSE, NY
528A7-19-708
10/21/20
C T e m p \R e v it F ile s \S y ra c u s e
V A
D W in g
R e n o v a ti o n s m p a tt e rs o n
C J
.r v t
/2
/2
:1
:2
P
M
1-AS-001
GENERAL NOTES, TYPICAL
ELEVATIONS
SCALE: 1/2" = 1'-0"1-AS-001
3 TYPICAL MOUNTING HEIGHTS
SCALE: 1/2" = 1'-0"1-AS-001
2 TYPICAL TOILET ROOM MOUNTING HEIGHTS
SCALE: 1/2" = 1'-0"1-AS-001
4 TYPICAL CABINET TYPE LEGEND
NOTE:
ALL ITEMS INDICATED ON THIS SHEET MAY
NOT BE PRESENT IN THE SCOPE OF WORK.
NOTE:
STC RATINGS INDICATED VALID WHEN PARTITION
EXTENDS TO DECK ABOVE AND SEALED.
SCALE: 1 1/2" = 1'-0"1-AS-001
6 1HR RATED ASSEMBLY TO CONCRETE DECK
SCALE: 1 1/2" = 1'-0"1-AS-001
7 2HR RATED ASSEMBLY TO CONCRETE DECK
SCALE: 1/2" = 1'-0"1-AS-001
1 TOILET ROOM FIXTURE LOCATIONS
Revisions: Date:
1 - ADDENDUM 2 Date1-28-21
SS SS
S S
REF.
LIFE SAFETY LEGEND:
EGRESS PATH
EXIT SIGN (E-EXISTING)
1 HR FIRE BARRIER / SMOKE
BARRIER (45 MINUTE DOOR AND
FIRE / SMOKE DAMPERS)
EXISTING AREA TO REMAIN
(NOT IN CONTRACT)
INDICATES EXIT ACCESS POINT
2 HR FIRE RATED PARTITION/ SMOKE
BARRIER (1 1/2 HOUR DOOR AND
FIRE / SMOKE DAMPERS
FIRE EXTINGUISHER CABINETFEC
NON FIRE BARRIER SMOKE
LIMITING BARRIER
HORIZONTAL EXIT
1 HR FIRE BARRIER
(45 MINUTE DOOR)
2 HR FIRE BARRIER (1 1/2 HR DOOR
AND FIRE DAMPERS)
FIRE HOSE CABINETFHC
HE
NOTE:
GENERAL CONTRACTOR TO VERIFY INTEGRITY OF
RATED PARTITIONS INDICATED AS EXISTING WITHIN THE
PROJECT AREA. PROVIDE SAFING/ AND PATCHING AS
REQUIRED TO ACHIEVE RATING INDICATED.
A B BB C
CONF.
D325
OFFICE
D323A
OFFICE
D323B
SWING SPACE
D321
SWING SPACE
D305
SWING SPACE
D304
D301
JAN. (E)
OFFICE
D308
LAB
D311
OFFICE
D323
OFFICE
D324
'-8
/2
(E
'-7
(E
'-0
(E
'-2
(E
'-6
(E
HOOD
M A
X D
E A
D E
N D
C O
R R
ID
O
R
M A
X C
O M
M O
N P
A T
H O
F T
R A
V E
L
M A
X T
R A
V E
L D
IS
T
A N
C E
39'-3" V.I.F.
20'-3" (E) 6'-8" (E) 13'-7" (E)
'-8
/2
V
.I .F
'-6
(E
'-1
(E
'-4
(E
9'-9" (E) 10'-1" (E) 18'-9" (E)
'-5
(E
'-4
(E
'-4
(E
'-4
(E
'-4
(E
'-5
(E
'-6
(E
'-8
(E
'-1
(E
'-1
/8
(E
'-8
/8
(E
'-0
(E
'-1
(E
OFFICE
D322
TOILET
D303 D320
LAB
D314
HOT/COLD PROCESSING
D313
FEC
FEC
19'-3" (E) 20'-2" (E)
HE
D307A
BLS-3 LAB
D307
BLS-3 ANTE
ROOM
BUSINESS
II (0,0,0)
74'-0"' (COMPLIES) 3RD FLR
51'-0" (COMPLIES) 3RD FLR
22'-0" (COMPLIES) 3RD FLR
VARIES: 8'-0" TO 6'-0"
(COMPLIES)
(2) EXITS (COMPLIES)
NA
.3" / OCCUPANT=13"
7.3.3.1
N.A.
N.A.
.2" / OCCUPANT=8.8"
7.3.3.1
72" (COMPLIES)
2-HR RATED
(COMPLIES)
2 HR-4 STORIES & MORE
1 HR-3 STORIES & LESS
7.1.3.2.1
OCCUPANCY: BUSINESS
MAXIMUM DEAD
END CORRIDOR
COMMON PATH
OF TRAVEL
RATINGS -
CORRIDORS
RATINGS -
STAIRS
2 HR-4 STORIES & MORE
1 HR-3 STORIES & LESS
BUT NO LESS THAN
FLOOR RATING
8.6.5
RATINGS -
SHAFTS
ACTUAL / REMARKS
(IF APPLICABLE)
NFPA 101
PROJECT/BUILDING INFORMATION
BUILDING SQUARE FOOTAGE: NA
BUILDING IS FULLY SPRINKLERED
PROJECT IS LOCATED AT THE 3RD & 4TH FLOOR OF HOSPITAL
HOSPITAL HAS TOTAL OF 9 FLOORS PLUS BASEMENT
LIFE SAFETY SCHEDULE
CODE
OCCUPANCY
CONSTRUCTION
TYPE
MAX. TRAVEL
DISTANCE
300' 38.2.6
REMOTENESS OF
EXITS
REQUIRED NUMBER
OF EXITS
MINIMUM
CORRIDOR WIDTH
REQUIRED EGRESS
WIDTH (PROJECT
CORRIDOR)
REQUIRED STAIR
DIMENSIONS (EXIST)
WIDTH
LANDINGS
RISERS
TREADS
HEAD HEIGHT
REQUIRED EGRESS
WIDTH (STAIRS)
RATING-STORAGE
OCCUPANT LOAD 1 OCCUPANT/100 SF 44 OCCUPANTS MAX
NEW BUSINESS
CHAPTER 38
100' 38.2.5.3
50' 38.2.5.2
NOT LESS THAN 1/3
MAX DISTANCE (126'-6")
7.5.4.2
(COMPLIES)
38.2.4.2
44" (3'-8") 38.2.3.2
44" MIN.
7 1/2" MAX.
10" MIN.
6'-8" MIN.
NO RATING REQUIRED
38.3.6
2-HR RATED
(COMPLIES)
RATING-SOILED/
WASTE
1 HR OR SPRINKLER W/
SMOKE BARRIER 38.3.2.1
& 8.7.1.1
1-HR RATED
(COMPLIES)
2-HR RATED
(COMPLIES)
1-HR RATED
(COMPLIES)
ALLOWABLE
STORIES & HEIGHT
ALLOWABLE AREA
FLOOR TO FLOOR HEIGHT: 10'-0"
1 HR OR SPRINKLER W/
SMOKE BARRIER 38.3.2.1
& 8.7.1.2
58'-0"' (COMPLIES) 4TH FLR
52'-0" (COMPLIES) 4TH FLR
42'-0" (COMPLIES) 4TH FLR
42'-0"
NANA
NANA
HYMAN
HAYES
ASSOCIATES
6 Wembley Court, Albany, NY 12205
(518) 452-3470 www.hymanhayes.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ARCHITECT:
VA MEDICAL CENTER SYRACUSE
3RD & 4TH fOOR 'D' WING
RENOVATIONS
VAMC, SYRACUSE, NY
528A7-19-708
10/21/2020
C T e m p \R e v it F ile s \S y ra c u s e
V A
D W in g
R e n o v a ti o n s m p a tt e rs o n
C J
.r v t
/1 /2
:4
:3
A
M
1-AS-101
THIRD FLOOR LIFE SAFETY PLAN
PROJECT
NORTH
KEY PLAN- 4TH FLOOR
SCALE: 1/8" = 1'-0"1-AS-101
1 THIRD FLOOR PLAN LIFE SAFETY
PROJECT
NORTH
STAIR EXITS TO FIRST
FLOOR CORRIDOR
SS SS
S S
78 SF
OFFICE
D425
77 SF
OFFICE
D423
78 SF
OFFICE
D421
87 SF
OFFICE
D411A
198 SF
SCI / RESEARCH LAB
D407
390 SF
SCI PROCEDURE RM
D405
106 SF
TOILET (E)
D412
105 SF
D408
BREAK
ROOM 78 SF
SOILED UTILITY
D402
72 SF
TOILET
D401
764 SF
MECHANICAL
D417
STORAGE
D404
219 SF
C429
LARGE
EXAM
HOME
CARE
NURSE
257 SF
CUBICLES (4)
D426
79 SF
OFFICE
D419
210 SF
C426
EXAM
177 SF
C428
EXAM
204 SF
C423
LARGE
EXAM
130 SF
C432
HOME
CARE
NURSE
180 SF
C430
EXAM
226 SF
C434
LARGE
EXAM
JAN. (E)
D406
39'-9" (E)
'-8
/2
V
.I .F
39'-3" V.I.F.
M A
X D
E A
D E
N D
C O
R R
ID
O
R
M A
X C
O M
M O
N P
A T
H O
F T
R A
V E
L
M A
X T
R A
V E
L D
IS
T
A N
C E
STAIR EXITS TO FIRST FLOOR
CORRIDOR
20'-4 1/2" 18'-4 1/2"
'-3
'-1
/2
'-6
/2
'-7
'-1
/2
'-9
(E
'-1
/4
(E
'-2
(E
'-1
(E
'-8
(E
'-8
/2
(E
'-2
/2
(E
'-4
(E
13'-3 1/2" (E)
15'-8 1/2" (E)
18'-7" (E)
239 SF
CONF. ROOM
D409
'-3
'-1
/2
'-7
'-9
/2
371 SF
D415
CUBICLES
96 SF
D411B
OFFICE
88 SF
D411C
OFFICE
PRINTER/MAIL
AREA
'-4
'-7
FEC
FEC
FEC
HE
LIFE SAFETY LEGEND:
EGRESS PATH
EXIT SIGN (E-EXISTING)
1 HR FIRE BARRIER/ SMOKE
BARRIER (45 MINUTE DOOR AND
FIRE / SMOKE DAMPERS)
EXISTING AREA TO REMAIN
(NOT IN CONTRACT)
INDICATES EXIT ACCESS POINT
2 HR FIRE BARRIER/ SMOKE
BARRIER (1 1/2 HOUR DOOR AND
FIRE / SMOKE DAMPERS
FIRE EXTINGUISHER CABINETFEC
NON FIRE BARRIER SMOKE
LIMITING BARRIER
HORIZONTAL EXIT
1 HR FIRE BARRIER
(45 MINUTE DOOR)
2 HR FIRE BARRIER
(1 1/2 HR DOOR AND FIRE DAMPERS)
FIRE HOSE CABINETFHC
HE
BUSINESS
II (0,0,0)
74'-0"' (COMPLIES)
51'-0" (COMPLIES)
22'-0" (COMPLIES)
VARIES: 8'-0" TO 6'-0"
(COMPLIES)
(2) EXITS (COMPLIES)
NA
.3" / OCCUPANT=13"
7.3.3.1
N.A.
N.A.
.2" / OCCUPANT=8.8"
7.3.3.1
72" (COMPLIES)
2-HR RATED
(COMPLIES)
2 HR-4 STORIES & MORE
1 HR-3 STORIES & LESS
7.1.3.2.1
OCCUPANCY: BUSINESS
MAXIMUM DEAD
END CORRIDOR
COMMON PATH
OF TRAVEL
RATINGS -
CORRIDORS
RATINGS -
STAIRS
2 HR-4 STORIES & MORE
1 HR-3 STORIES & LESS
BUT NO LESS THAN
FLOOR RATING
8.6.5
RATINGS -
SHAFTS
ACTUAL / REMARKS
(IF APPLICABLE)
NFPA 101
PROJECT/BUILDING INFORMATION
BUILDING SQUARE FOOTAGE: NA
BUILDING IS FULLY SPRINKLERED
PROJECT IS LOCATED AT THE 3RD & 4TH FLOOR OF HOSPITAL
HOSPITAL HAS TOTAL OF 9 FLOORS PLUS BASEMENT
LIFE SAFETY SCHEDULE
CODE
OCCUPANCY
CONSTRUCTION
TYPE
MAX. TRAVEL
DISTANCE
300' 38.2.6
REMOTENESS OF
EXITS
REQUIRED NUMBER
OF EXITS
MINIMUM
CORRIDOR WIDTH
REQUIRED EGRESS
WIDTH (PROJECT
CORRIDOR)
REQUIRED STAIR
DIMENSIONS (EXIST)
WIDTH
LANDINGS
RISERS
TREADS
HEAD HEIGHT
REQUIRED EGRESS
WIDTH (STAIRS)
RATING-STORAGE
OCCUPANT LOAD 1 OCCUPANT/100 SF 44 OCCUPANTS MAX
NEW BUSINESS
CHAPTER 38
100' 38.2.5.3
50' 38.2.5.2
NOT LESS THAN 1/3
MAX DISTANCE (126'-6")
7.5.4.2
COMPLIES
38.2.4.2
44" (3'-8") 38.2.3.2
44" MIN.
7 1/2" MAX.
10" MIN.
6'-8" MIN.
NO RATING REQUIRED
38.3.6
2-HR RATED
(COMPLIES)
RATING-SOILED/
WASTE
1 HR OR SPRINKLER W/
SMOKE BARRIER 38.3.2.1
& 8.7.1.1
1-HR RATED
(COMPLIES)
2-HR RATED
(COMPLIES)
1-HR RATED
(COMPLIES)
ALLOWABLE
STORIES & HEIGHT
ALLOWABLE AREA
FLOOR TO FLOOR HEIGHT: 10'-0"
1 HR OR SPRINKLER W/
SMOKE BARRIER
PARTITION 38.3.2.1 & 8.7.1.2
58'-0"' (COMPLIES)
52'-0" (COMPLIES)
42'-0" (COMPLIES)
42'-0"
HYMAN
HAYES
ASSOCIATES
6 Wembley Court, Albany, NY 12205
(518) 452-3470 www.hymanhayes.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ARCHITECT:
VA MEDICAL CENTER SYRACUSE
3RD & 4TH fOOR 'D' WING
RENOVATIONS
VAMC, SYRACUSE, NY
528A7-19-708
10/21/2020
C T e m p \R e v it F ile s \S y ra c u s e
V A
D W in g
R e n o v a ti o n s m p a tt e rs o n
C J
.r v t
/1 /2
:4
:2
P M
1-AS-102
FOURTH FLOOR LIFE SAFETY PLAN
PROJECT
NORTH
SCALE: 1/8" = 1'-0"1-AS-102
1 FOURTH FLOOR PLAN LIFE SAFETY
Revisions: Date:
JStasack Snapshot
R E
F
REF.
ALIGN
mm
VERTICAL
US
HORIZONTAL
MOVEMENT ±
mm US
JOINT WIDTH
US mm
4" [102mm]
10 3/8" [264mm]
1/4" [6mm]
CONT. ALUM. TAPERED
CENTER PLATE (J4C004)
CONT. ALUM. SURFACE
MOUNT FRAME (J4A013)
STEEL CENTERING BAR
(7 PER PLATE @ 18"
[457mm] O.C.) (J4J017)
FIN. FLR.
(BY OTHERS)
1/4" x 2 1/4” [M6x56] HEX
HEAD CONCRETE
SCREW (7 PER FRAME @
18" [457mm] O.C.) (JK001)
1/4" x 2 1/4” [M6x56] FLAT
HEAD CONCRETE SLEEVE
ANCHOR (7 PER PLATE @
18" [457mm] O.C.) (JK020)
HIGH STRENGTH EPOXY
GROUT (BY OTHERS)
4 1/8" [104mm]
MIN. BLOCKOUT
1 1/2"
[38mm]
CONT. ALUM.
RECESSED FRAME
(J4A004)
1/4-20 X 3" PHILLIPS FLAT
HEAD MACHINE SCREW W/
COMPRESSION SPRING
ASSEMBLY (7 PER PLATE
@ 18" [457mm] O.C.) (JK123)
461-A01-100
4" 102 2" 51 1" 25
PARTITION TYPE SYMBOLS
--S
PARTITION TYPE
HOURLY FIRE RATING: PARTITION EXTENDS
TO BOTTOM OF STRUCTURE ABOVE.
PARTITION TYPE
PARTITION EXTENDS TO DECK
ABOVE AND SEALED WITH SAFING.
FRAMING EXTENDS TO BOTTOM
OF STRUCTURE ABOVE.
PARTITION TYPE
FINISHES ONE SIDE EXTEND TO 6"
ABOVE HIGHEST ADJACENT CEILING.
FINISHES ONE SIDE EXTEND TO
BOTTOM OF STRUCTURE ABOVE.
PARTITION FRAMING EXTENDS TO
STRUCTURE ABOVE. GYPSUM WALL
BOARD TERMINATES 6" ABOVE HIGHEST
ADJACENT CEILING.
PARTITION TYPE
SUFFIX "S" INDICATES SMOKE BARRIER -
SEAL ONE SIDE TO DECK AND AROUND
ALL PENETRATIONS.
INFILL OPENING. MATCH WALL THICKNESS
AND ALIGN WITH EXISTING WALL.
INFILL
PARTIAL HEIGHT WALL TO UNDERSIDE OF
COUNTER UNLESS OTHERWISE NOTED.
PART
1. THE PARTITION TYPE SYMBOLS WILL KEY THE PARTITION TYPES ON PLANS.
2. ANY PENETRATION THROUGH HOURLY RATED PARTITIONS SHALL BE
FIRESTOPPED WITH MATERIALS TO EQUAL THE HOURLY RATING OF THE
PARTITION SYSTEM IN ACCORDANCE WITH THE SPECIFICATIONS. EXISTING
WALLS WITH NEW PENETRATIONS ARE TO BE SEALED AS REQUIRED TO
MAINTAIN RATING.
3. ALL NEW PARTITIONS TO BE UNLESS OTHERWISE NOTED.
COORDINATE WITH PARTITION TYPE SCHEDULE.
4. ALL CHASES AND DUCT/ PIPE/ COLUMN ENCLOSURES TO BE UNLESS
OTHERWISE NOTED.
5. ALL SINK CARRIER WALLS TO BE UNLESS OTHERWISE NOTED.
PARTITION TYPE NOTES
J18
J08
L10
CONSTRUCTION NOTES:
1. LOCATE SIDE OF DOOR FRAMES 4" FROM PERPENDICULAR
WALL UNLESS OTHERWISE INDICATED.
2. CONTRACTOR TO COORDINATE LOCATION OF ALL
PARTITIONS ENCLOSING EQUIPMENT WITH APPROVED SHOP
DRAWINGS.
3. PROVIDE 1/2" X 6" FIRE RETARDANT PLYWOOD BLOCKING OR
6" HIGH X 18 GA SHEET BLOCKING IN PARTITIONS AT ALL
LOCATIONS WITH SURFACE APPLIED EQUIPMENT OR
ACCESSORIES SUCH AS HANDRAILS, TOILET ACCESSORIES,
WALL BUMPERS, WALL MOUNTED DOOR STOPS AND FOR
SUPPORT OF WALL CABINETS, SHELVES, EQUIPMENT, ETC.
4. CONFIRM CHASE WALL DIMENSIONS WITH PLUMBING
CONTRACTOR, NOTIFY VA COORDINATOR OF ANY
DISCREPANCIES.
5. CUT AND PATCH EXISTING CONSTRUCTION AS REQUIRED TO
COMPLETE THE WORK.
6. MINOR ITEMS OF WORK SUCH AS CUTTING, BLOCKING, TRIM,
ETC. SHALL BE PERFORMED AS REQUIRED TO MAKE THE
WORK COMPLETE WHETHER SHOWN OR NOTED ON THE
CONTRACT DOCUMENTS OR NOT.
7. RESTORE DAMAGED AND EXPOSED FINISHES OR PATCHED
AREAS IN A MANNER WHICH ELIMINATES EVIDENCE OF
PATCHING AND REFINISHING.
A B BB C
78 SF
OFFICE
D425
77 SF
OFFICE
D423
78 SF
OFFICE
D421
87 SF
OFFICE
D411A
198 SF
SCI / RESEARCH LAB
D407
390 SF
SCI PROCEDURE RM
D405
106 SF
TOILET (E)
D412
105 SF
D408
BREAK
ROOM
78 SF
SOILED UTILITY
D400
72 SF
TOILET
D401
764 SF
MECHANICAL
D417
STORAGE
D404
219 SF
C429
LARGE
EXAM
HOME
CARE
NURSE
257 SF
CUBICLES (4)
D426
79 SF
OFFICE
D419
210 SF
C426
EXAM
177 SF
C428
EXAM
204 SF
C423
LARGE
EXAM
130 SF
C432
HOME
CARE
NURSE
180 SF
C430
EXAM
226 SF
C434
LARGE
EXAM
JAN. (E)
D406
1-AS-402
1-AS-403
1-AS-402
1-AS-404
1-AS-404
'-3
/8
'-1
/2
'-7
'-7
/2
'-0
/2
'-9
(E
10'-7 3/4"
6'-7 1/2"
135.00°
20'-4 5/8" 18'-5 1/2"
'-8
/8
'-6
/2
'-8
5'-7"135.00°
39'-9" V.I.F.
5' -1
1"
5'-1 1/4"
D426
D425
D423
D421
D405A
D407
D401
D470CD419
D411A
D411C
C436F
C429
C434
D405B
9'-1"
'-0
9'-3"
3'-2 1/2"
4'-3"
18'-7"
C426
'-8
/2
V
.I .F
J10
J10
J10
J10
J10
J10 J10
J10
J10
J10
PART
J10
PART
J10
J08
39'-3" V.I.F.
J10
1-AS-402
J10
J10
D409
J18
1-AS-404
1-AS-402
2'-5 1/2"
ALL FURNITURE SHOWN FOR REFERENCE ONLY.
OWNER TO SUPPLY AND INSTALL UNLESS
OTHERWISE NOTED
J10
J10
EXISTING EXPANSION JOINT LOCATION
COORDINATE FINISHED FLOOR & WALL BASE
INSTALLATION. CONTRACTOR TO REPLACE
EXISTING EXPANSION JOINT AS SPECIFIED BY
MAUFACTURER SEE DETAIL 6/1-AS-103
EXPANSION JOINT REPLACEMENT
A08
D411B
1-AS-404
1-AS-405
D403
D410
D414
D416
D405A
D415
88 SF
D411C
OFFICE
96 SF
D411B
OFFICE
239 SF
CONF. ROOM
D409
J10
J10
J10
1-AS-405
A0
A0
A0
A0
A0
A0
A0
A0
A0
A0
A0
A0
A0
A0
PROVIDE CEMENTIOUS UNDERLAYMENT
THROUGHOUT D WING PROPOSED FLOOR
REPLACMENT 3RD & 4TH FLOOR
'-0
J18
'-1
'-3
'-4
NOTE: AFTER DEMO & PRIOR TO START OF PROPOSED CONSTRUCTION; CONTRACTOR TO
PROVIDE CEMENTITIOUS UNDERLAYMENT OVER ENTIRE SUBFLOOR OF D-WING PROJECT AREA
(APPROXIMATELY - 3,820 SQFT) TO ALLOW FOR A LEVEL FINISHED FLOORING INSTALLATION.
FILL/PLUG ALL HOLES WATER TIGHT & TO APPROPRIATE FIRE RATING TO MATCH EXISTING
ADJACENT PRIOR TO INSTALLATION, SEE DETAIL 6/1-AS-103.
1-AS-103
1-AS-103
1-AS-103
27 SF
STORAGE
C441A
D415
PROVIDE WALL PROTECTION,
HANDRAIL & WALL PNT TO
MATCH EXISTING ADJACENT
FEC
FEC
FEC
96 SF
C420
TELEHEALTH
D432
CORRIDOR
D432A
CORRIDOR PROVIDE WALL PROTECTION,
HANDRAIL & WALL PNT TO
MATCH EXISTING ADJACENT
1'-6"
11'-7 1/2"
'-1
'-7
3'-2 3/8"
J08
L14
L14
G08
L14
D402
D404
D406
D408
D414
D410
D416
D432
D417
D412
D432A
PROVIDE NEW WALL SHEATHING AND FINISHES
TO MATCH EXISTING ADJACENT MATERIALS @
ALL CHASE LOCATIONS DISTURBED BY
ASBESTOS ABATEMENT. COORDINATE ALL
WORK W/ ASBESTOS ABATEMENT PLANS PRIOR
TO CONSTRUCTION. (TYP. FOR ROOMS C434,
C432, C430, C429, C428, C426 & C423.)
4'-10 1/2"
7'-7"
ON EXISTING DOOR PROVIDE AUTOMATIC DOOR
OPERATORS AND CONTROLS PER
SPECIFICATION SECTION 087113. ALL HARDWARE
SHOULD BE CONSISTENT WITH HARDWARE
GROUP 10A
PROVIDE WALL MOUNTED CASEWORK @ EXISTING SINK
LOCATION
A B BB C
8'-0"
10'-4"8'-0"
19'-8"
8'-0" (E)
19'-3" (E)
1'-5"
'-0
10'-9"
20'-2" (E)
10'-4" (E)
'-0
(E
'-6
(E
3'-6" (E)
1'-0"
6'-0"
'-1
'-0
6'-0" (E)
'-4
(E
'-7
(E
'-2
(E
'-0
(E
20'-3" (E) 6'-8" (E)
'-5
(E
'-4
(E
'-4
(E
'-4
(E
'-4
(E
'-5
(E
13'-10" (E)
6'-7" (E)
CONF.
D325
OFFICE
D323A
OFFICE
D323B
SWING SPACE
D321
SWING SPACE
D305
SWING SPACE
D304
D301
JAN. (E)
OFFICE
D308
LAB
D311
OFFICE
D323
OFFICE
D324
'-1
13'-7" (E)
9'-9" (E) 10'-1" (E) 18'-9" (E)
2'-6"
'-7
7"
2'-1 1/2"
'-2
1'-6"
'-8
20'-2" (E)
'-1
(E
'-1
'-2
/2
2'-1 1/2"
'-1
1'-8 1/2"
19'-6" (E)
'-7
/2
(E
'-0
/2
'-8
/2
(E
'-7
(E
'-0
(E
'-2
(E
'-6
(E
'-6
(E
H O
O D
1-AS-401
D304E
J10
LAB
D314
D313
HOT/COLD
PROCESSING
HOOD
'-0
'-8
/4
OFFICE
D322
TOILET
D303
INFILL
J08
INFILL
J08
L18
J18
SEE SHEET 1-AS-001 FOR TYP.
BATHROOM ELEVATIONS
RELOCATE EXISTING HOT/COLD UNITS & PROVIDE
ALL ASSOCIATED MECH., PLUMBING &
ELECTRICAL AS NEEDED TO ALLOW FOR PROPER
INSTALLATION. INSTALL NEW FLOORING &
CEILING TO ALLOW FOR PROPER ALIGNMENT
6'-0"
D322
D320
D303
STORAGE
D320
12'-6"
8'-5 1/2"3'-8"
J18
J18
D312
D306
1-AS-401
HOOD
D310
A0
A0
A0A0
A0
A0
A0
A0
A0
A0
A0
'-9
/2
A0
A0
'-7
/4
'-4
'-0
CONTRACTOR TO PROVIDE CEMENTITIOUS UNDERLAYMENT
@ ALL EXISTING ROOMS TO RECIEVE NEW FINISHED
FLOORING. FILL/PLUG ALL HOLES WATER TIGHT & TO
APPROPRIATE FIRE RATING TO MATCH EXISITNG ADJACENT,
SEE DETAIL 6/1-AS-103
FEC
FEC
D300A
CORRIDOR
D300
CORRIDOR
A0A08
D307A
BLS-3 LAB
D307
BLS-3 ANTE
ROOM
D313A
Room
D313B
Room
D323B D323A
D323
D325
D324
D321 D301
D304
D305
D308
D306
D310
D312
D311
D314D313
1-AS-405
CONTRACTOR TO PROVIDE ELEVATOR CONTROL
SEQUENCING. COORDINATE W/ OWNER'S
VENDOR TO ALLOW FOR PROPOSED
CONSTRUCTION
D344
SEALANT BOTH SIDES
VARIES
1/2" THICK NEOPRENE PAD
LINE OF EXISTING WINDOW FRAME
METAL END CAP, MATCH WINDOW
SEALANT FULL PERIMETER
WALL PARTITION
WINDOW MULLION
LINE OF WINDOW
FRAME- BEYOND
LINE OF WINDOW
FRAME- BEYOND
/8
METAL END CAP.PAINT
TO MATCH MULLION,
TO BE CONTINUOUS
AROUND THE NEW
PARTITION
LINE OF SILL BELOW
SEALANT
EQ EQ
X
DIAMETER
CORED HOLE
EXISTING CONCRETE SLAB
STEEL CHANNEL
WIDTH = X+2
LENGTH = X+6
1/2" DIA. x 2" LONG EMBEDED HILTI
HDI DROP IN ANCHOR (TYP.)
FILL CORED HOLE W/ NON-
SHRINK GROUT
NOTE:
COORDINATE FLOOR OPENING W/
MEP DRAWINGS
HYMAN
HAYES
ASSOCIATES
6 Wembley Court, Albany, NY 12205
(518) 452-3470 www.hymanhayes.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ARCHITECT:
VA MEDICAL CENTER SYRACUSE
3RD & 4TH fOOR 'D' WING
RENOVATIONS
VAMC, SYRACUSE, NY
528A7-19-708
10/21/20
C T e m p \R e v it F ile s \S y ra c u s e
V A
D W in g
R e n o v a ti o n s m p a tt e rs o n
C J
.r v t
/2
/2
:1
:3
P
M
1-AS-103
THIRD & FOURTH FLOOR PLANS
PROJECT
NORTH
SCALE: 1/8" = 1'-0"1-AS-103
2 FOURTH FLOOR PLAN
PROJECT
NORTH
KEY PLAN- 4TH FLOOR
SCALE: 1/8" = 1'-0"1-AS-103
1 THIRD FLOOR PLAN
PROJECT
NORTH
SCALE: 1 1/2" = 1'-0"1-AS-103
3 PARTITION TO WINDOW
1 PREPARE EXISTING SUBFLOOR TO ALLOW FOR PROPOSED
NEW FLOORING; COORDINATE INSTALLATION W/
MANUFACTURER'S SPECIFICATIONS
2 PREPARE EXISTING CMU WALL SURFACES TO RECEIVE NEW
PAINT COORDINATE W/ MANUFACTURER'S SPECIFICATIONS
3 VERIFY EXISTING CONDITION OF ALL DOORS, FRAMES &
FINISHES TO REMAIN. REPORT TO VA COR ANY ADVERSE
CONDITIONS
4 EXISTING FINISHED FLOORING TO REMAIN @ CORRIDOR;
COORDINATE FLOORING REPLACEMENT W/ PROPOSED C429
RENOVATIONS AND WALL INFILL, REPLACE FLOORING TO
MATCH EXISTING ADJACENT AS NEEDED TO ALLOW FOR
PROPOSED CONSTRUCTION
5 PATCH & PAINT EXISTING GWB WALL FINISH @ ALL PROPOSED
WALL INFILL AND PROPOSED NEW DOOR & FRAME LOCATIONS
AS NEEDED TO ALLOW FOR A CONTINUOUS SMOOTH SURFACE.
PRIME & PAINTED TO MATCH EXISTING ADJACENT WALL FINISH
6 PROVIDE WALL INFILL TO MATCH EXISTING ADJACENT
CONSTRUCTION & FINISHES TO ALLOW FOR A CONTINUOUS
SMOOTH SURFACE
7 PROVIDE ALUMINUM J- CHANNEL @ ALL PROPOSED GWB WALL
FINISH TO EXISTING CMU WALL TRANSITIONS. FINISHED GWB
SURFACE TO BE IN ALIGNMENT W/ FACE OF CMU. PROVIDE FIRE
SEALANT @ ALL RATED ASSEMBLIES
8 PATCH AND PAINT EXISTING WALL SURFACE TO ALLOW FOR A
SMOOTH CONTINUOUS SURFACE FLUSH WITH EXISTING
ADJACENT WHERE ALL WALL MOUNTED ITEMS WERE
REMOVED.
KEY NOTES:
SCALE: 1" = 1'-0"1-AS-103
4 PARTITION TO WINDOW MULLION
PHASE 1: 3RD FLOOR D-WING PHASE 2A: 4TH FLOOR D-WING
PHASE 2B: 4TH FLOOR C-WING,
SCI EXAM ROOMS
PHASE 2C: 4TH FLOOR C-WING
SCALE: 1" = 1'-0"1-AS-103
5 CORE HOLE INFILL - TYPICAL
SCALE: 3" = 1'-0"1-AS-103
6 EXPANSION JOINT
BLS-3 LAB (307A) & BLS-3 ANTE (307) TO REMAIN
OPERATIONAL THROUGHOUT ENTIRETY OF CONSTRUCTION
F
A B BB C
D325
D323AD323B
D323
D324
D301
D321
D305
D311
D308
D304
D313
D314
D322
D303
1-AS-401
8'-0" 8'-0"
8'-0"
8'-0" 8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
1-AS-401
8'-0"
D300
D300A
ALL CEILING HEIGHTS ARE FROM FINISHED FLOOR
D320
1-AS-405
8'-0"
5/8" GWB
SUSPENDED
CEILING
SEE REFLECTED
CEILING PLAN
SEE REFLECTED
CEILING PLAN
SEE REFLECTED
CEILING PLAN
EXIST. CONCRETE DECK
3 5/8" x 20 GA. METAL STUDS @
1'-4" O.C. ANCHORED TO
UNDERSIDE OF EXISTING DECK.
BRACE STUDS @ STRUCTURE
ABOVE AS REQUIRED
EXIST. CONCRETE DECK
3 5/8" x 20 GA. METAL STUDS
@ 1'-4" O.C. ANCHORED TO
UNDERSIDE OF EXISTING
DECK
5/8" GWB
3 5/8" MTL. STUD BRACING AT 2'-8" O.C.
SUSPENDED CEILING
(SEE REFLECTED CEILING PLAN)
VARIES
SEE REFLECTED
CEILING PLAN
SEE REFLECTED
CEILING PLAN
SEE REFLECTED
CEILING PLAN
REFLECTED CEILING PLAN NOTES
1. VERIFY FINAL LOCATION OF ALL CEILING PENETRATIONS WITH OWNER,
MECHANICAL AND ELECTRICAL CONTRACTORS PRIOR TO INSTALLATION OF
CEILING SYSTEM.
2. SOFFITS ARE TO BE 5/8" GYPSUM WALL BOARD ON 3 5/8" METAL STUDS AT
1'-4" O.C. UNLESS OTHERWISE NOTED.
3. REMOVE EXISTING CEILING SYSTEM, INCLUDING OUTSIDE OF PROJECT
WORK AREA AS REQUIRED FOR INSTALLATION OF DUCTWORK, AND
ELECTRICAL WIRING/ CONDUIT NOT SHOWN ON THESE DRAWINGS.
REINSTALL FOLLOWING COMPLETION OF WORK NOTED. SEE MECHANICAL,
PLUMBING AND ELECTRICAL DRAWINGS.
4. ALL SOFFITS AT WALL CABINETS TO OVERHANG EXPOSED CABINET SIDES 1".
BOTTOM OF ALL SUCH SOFFITS TO BE 7'-0" A.F.F. UNLESS NOTED
OTHERWISE.
5. ALL AREAS NOT DESIGNATED TO RECEIVE A NEW CEILING HAVE AN EXISTING
CEILING OR ARE TO HAVE EXPOSED STRUCTURE.
6. REPLACE ANY EXISTING CEILINGS DAMAGED AS A RESULT OF THE NEW
WORK. MATCH EXISTING CONSTRUCTION.
7. ALL DIMENSIONS ON REFLECTED CEILING PLAN ARE TO FACE OF FINISHED
SURFACE UNLESS NOTED OTHERWISE.
8. LIGHT FIXTURES, SPRINKLER HEADS, ETC. TO BE LOCATED CENTERED ON
CEILING TILE UNLESS OTHERWISE INDICATED.
9. ALL SUSPENDED CEILING SYSTEMS ARE TO BE CENTERED WITHIN THE
OVERALL DIMENSIONS OF THE ROOM UNLESS NOTED OTHERWISE.
10. REFER TO FINISH SCHEDULE FOR ADDITIONAL CEILING FINISH INFORMATION.
11. REFER TO FINISH SCHEDULE FOR ALL CEILING HEIGHTS NOT DESIGNATED.
WALL / CEILING MOUNTED EXIT SIGN
CEILING GRID START POINT
SUPPLY GRILLE - COORDINATE WITH
MECHANICAL DRAWINGS
NEW 2'x2' ACOUSTICAL TILE CEILING
GYPSUM BOARD CEILING,
BULKHEAD, SOFFIT AND
FASCIA
RECESSED LIGHT FIXTURE
2'x4' RECESSED LIGHT FIXTURE
2'x2' RECESSED LIGHT FIXTURE
CEILING LEGEND:
EXHAUST/ RETURN GRILLE - COORDINATE
WITH MECHANICAL DRAWINGS
PRIVACY CURTAIN TRACK
1'x4' RECESSED LIGHT FIXTURE
1'x4' SUSPENDED LIGHT FIXTURE
CEILING MOUNTED PATIENT LIFT
SPRINKLER HEAD REF. FIRE PROTECTION DWGS.
A B BB C
D401
D405
D426
D425
D423
D407
D421
D419
D406 D404
D408
D411A
D412
D417
D400
C426
C428
C430
C432
C434
C429
C423
1-AS-104
1-AS-104
1-AS-104
1-AS-104
COORDINATE CEILING & LIGHTING INSTALLATION W/
PROPOSED 3-D PATIENT LIFT (TYP.).
PROVIDE 3-D PATIENT LIFT & ASSOCIATED DECK
MOUNTING BRACKETS; INSTALL PER MANUFACTURER'S
SPECIFICATIONS (TYP.) 6/1-AS-104
'-7
'-8
1-AS-402
1-AS-402
1-AS-402
1-AS-402
1-AS-403
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
1-AS-104
2'-2"
1-AS-404
1-AS-405
1-AS-405
1-AS-104
COORDINATE CEILING & LIGHTING INSTALLATION W/
PROPOSED 3-D PATIENT LIFT (TYP.).
PROVIDE 3-D PATIENT LIFT & ASSOCIATED DECK
MOUNTING BRACKETS; INSTALL PER MANUFACTURER'S
SPECIFICATIONS (TYP.) 6/1-AS-104
8'-0"
8'-0"
ALL CEILING HEIGHTS ARE FROM FINISHED FLOOR
D409
D411CD411B
1-AS-104
1-AS-104
EXISTING DIFFUSER LOCATIONS TO REMAIN;
COORDINATE PROPOSED GRID INSTALLATION (TYP.)
EXISTING DIFFUSER LOCATIONS TO REMAIN;
COORDINATE PROPOSED GRID INSTALLATION (TYP.)
EXISTING DIFFUSER LOCATIONS TO REMAIN;
COORDINATE PROPOSED GRID INSTALLATION (TYP.)
EXISTING DIFFUSER LOCATIONS TO REMAIN;
COORDINATE PROPOSED GRID INSTALLATION (TYP.)
8'-0"
8'-0"
8'-0"
D415
D432
D432A
D411
D405A
OPEN TO STRUCTURE
7'-10"
C441A
7'-10"
7'-0"
8'-0"
7'-0"
7'-10"7'-0"
7'-10"
7'-10"
7'-0"
1-AS-104
EXIST. CONCRETE DECK
3 5/8" x 20 GA. METAL STUDS @
1'-4" O.C. ANCHORED TO
UNDERSIDE OF EXISTING DECK
5/8" GWB
3 5/8" MTL. STUD
BRACING AT 2'-8" O.C.
SUSPENDED CEILING
SEE REFLECTED
CEILING PLAN
SEE REFLECTED
CEILING PLAN
VARIES
1" OVERHANG TYP.
CONCRETE SLAB
HILTI CONCRETE INSERT
P1000 UNISTRUT
SPRING NUT
FLAT WASHER
LOCK WASHER
3/8" HEX NUT
3/8" THREADED ROD
3/8" HEX NUT
LOCK WASHERFLAT WASHER
3/8 X 1/12" COUPLER
LOCK WASHER
3/8" HEX NUT
P1063 UNISTRUT
FLAT PLATE
3/8" HEX BOLT
CEILING BRACKET
TRACK
CEILING
COORDINATE TRACK INSTALLATION
SYSTEM W/ MANUFACTURER'S
SPECIFICATIONS
UNISRUT 45 ANGLE
UNISRUT 45 ANGLE
HILTI CONCRETE INSERT
HYMAN
HAYES
ASSOCIATES
6 Wembley Court, Albany, NY 12205
(518) 452-3470 www.hymanhayes.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ARCHITECT:
VA MEDICAL CENTER SYRACUSE
3RD & 4TH fOOR 'D' WING
RENOVATIONS
VAMC, SYRACUSE, NY
528A7-19-708
10/21/20
C T e m p \R e v it F ile s \S y ra c u s e
V A
D W in g
R e n o v a ti o n s m p a tt e rs o n
C J
.r v t
/2
/2
:1
:3
P
M
1-AS-104
THIRD & FOURTH FLOOR
REFLECTED CEILING PLAN
SCALE: 1/8" = 1'-0"1-AS-104
1 THIRD FLOOR REFLECTED CEILING PLAN
SCALE: 1" = 1'-0"1-AS-104
4 TYPICAL BULKHEAD DETAIL
SCALE: 1" = 1'-0"1-AS-104
3 TYPICAL SOFFIT DETAIL
SCALE: 1/8" = 1'-0"1-AS-104
2 FOURTH FLOOR REFLECTED CEILING PLAN
PROJECT
NORTH
PROJECT
NORTH
PROJECT
NORTH
KEY PLAN- 4TH FLOOR
SCALE: 1" = 1'-0"1-AS-104
5 DETAIL - GYPSUM WALLBOARD SOFFIT AT WALL
SCALE: 1 1/2" = 1'-0"1-AS-104
6 LIFT TRACK MOUNTING DETAIL
SOFFIT ELEVATION TO MATCH EXISTING BULK HEAD
Revisions: Date:
B B
B BB B
B
BBB B
ALIGN
ALIGN
ALIGN
ALIGN
ALIGN
ALIGN
ALIGN
D D
D D
D
D D
D D
D
DD DD
DD DD
AA A
AA
A A
A AA
A
A
AA AAA
A A
A
A A
A
A A
A A
A A
A A
A A
AA A
AA AAA
A A
A
A A
A A
A A
AA AA
AA AA
A
AA A
A A
A A
A AA A A
A A
A A
A
AA AAAA
A A
A A
A
AA A
AA AA
A
AA AAA
A
A
A
A A
A
AA A
A A
AA
AA
A A
A A
A A
A A A A
A A
A A
A
A A A AA A
A A
A A
A A A
A A
A A
A A
A AA
C CC
C C
C
CC C
CC CC
C C
C
BB BB
B B
B B
B B
B
B BB B
ALIGN
A
LI
G N
D DD D
A AA
B BB
C CC
SHEET
TOP CAP
OUTSIDE
CORNER
5/16 " 8mm
3/4", 1-1/2" OR 3"
[19mm, 38mm, or 76mm] WING
TAPE-ON CORNER GUARD
USE 535 PL PREMIUM
WHEN INSTALLING
WITHOUT TAPE
FOR .080" [2mm] THICK SHEET, USE 417 TOP CAP, 418 VERTICAL DIVIDER BAR AND 419 INSIDE CORNER
2 3 5
3/8 " 10mm
VERTICAL
DIVIDER BAR 4
INSIDE
CORNER
1/2" 13mm
BUTT
JOINT
1/16" [2mm]
COLOR
MATCHED
CAULK
A B BB C
D325
CONF.
D323A
OFFICE
D323B
OFFICE
D321
SWING
SPACE
D305
SWING
SPACE
D304
SWING
SPACE
D301
JAN. (E)
D308
OFFICE
D311
LAB
D323
OFFICE D324
OFFICE
H O
O D
D314
LAB
D313
HOT/COLD
PROCESSING
D322
OFFICE
D303
TOILET
D320
STORAGE
D312
FIRE APP.
D310
ELEC.
D306
ELEC.
V .I .F
'-7
D300
D300A
CG-1
CG-1
V .I .F
'-0
V.I.F
8'-10" +/-
'-1
V .I .F
'-9
FTS
A B BB C
D425
OFFICE
D423
OFFICE
D421
OFFICE
D411A
OFFICE
D407
SCI /
RESEARCH
LAB
D405
SCI
PROCEDURE
RM
D412
TOILET (E)
D408
BREAK
ROOM
D400
SOILED
UTILITY
D401
TOILET
D417
MECHANICAL
STORAGE
D404
C429
LARGE
EXAM
HOME
CARE
NURSE
D426
CUBICLES
(4)
D419
OFFICE
C426
EXAM
C428
EXAM
C423
LARGE
EXAM
C432
HOME
CARE
NURSE
C430
EXAM
C434
LARGE
EXAM
D406
JAN. (E)
STORAGE
C441A
D409
CONF.
ROOM
D411
PRINTER/MAIL
AREA
D411B
OFFICE
D411C
OFFICE
D415
CUBICLES
D410
D414
D416
D403
D405A
PROVIDE FLOORING TO MATCH EXISTING
ADJACENT AS NEEDED TO ALLOW FOR
PORPOSED CONSTRUTION
EXISTING FLOORING TO REMAIN
CG-1
CG-1 CG-1
CG-1
CG-1
CG-1
CG-1
CG-2
CG-2
CG-2
CG-1
CG-1
CG-1
CG-1
CG-1
CG-1
CG-1
CG-1
CG-1
CG-1
CG-1
V.I.F
6'-0" +/- V
.I .F
'-0
V.I.F
8'–9" +/-
V.I.F
5'–11" +/-
'-0
5'-0"
'-3
'-0
V.I.F
7'-6" +/-
V .I .F
EXISTING FLOORING TO REMAIN
FTS
FTS
NOTE: CONTRACTOR TO CONFIRM REDUCER TRANSITION STRIP COMPLIES WITH SUBMITTED FLOORING
MATERIALS.
FLOOR HATCH LEGEND:
WSF
PFTLVT-1
NOTE: NOT ALL FINISHES ARE
INDICATED ON PLANS. ONLY
ROOMS/COLORS WHERE
PATTERNS ARE REQUIRED. SEE
ROOM FINISH SCHEDULE FOR
FLOORING TYPES WHERE THERE
ARE NO FLOOR PATTERNS.
CONCLVT-2
LVT-3
CHAIR RAIL
(TARKETT RAMPART)
CHAIR RAIL ONLY
B
TOP OF
WALL PANEL
WALL PROTECTION
PANEL ONLY
A
'-6
U N
L E
S S
N O
T E
D O
T H
E R
W
IS
E
'-0
IN
S
C H
E D
U L E
TOP OF
WALL PANEL
WALL PROTECTION
PANEL AND WALL
GUARDS
C U N
L E
S S
N O
T E
D O
T H
E R
W
IS
E
'-0
IN
S
C H
E D
U L E
'-0
FULL HEIGHT
FRP PANEL
FRP PANEL ONLY
D
NOTE: CONTRACTOR TO COORDINATE MATERIALS AND FINISHES W/ FINISH LEGEND & SCHEDULE ON 1-AS-802
(NO WOOD)
WALL PROTECTION LEGEND
WALL PROTECTION PANEL ONLY
CHAIR RAIL ONLY
WALL PROTECTION AND WALL GUARDS
FRP WALL COVERING
LVT FLOORING
SCHLUTER "RENO-K"
TRANSITION STRIP, VERIFY
ASSEMBLY THICKNESS FOR
TRANSITION STRIP
SELECTION
CONCRETE
LVT TILE
CONCRETE FLOOR SLAB
SCHLUTER "SCHIENE"
TRANSITION STRIP,
VERIFY ASSEMBLY THICKNESS
FOR TRANSITION STRIP SELECTION
LVT
7-3/4”
197mm
CONTINUOUS ALUMINUM
RETAINER .080” [2mm]
VINYL
COVER
.080”
[2mm]
CONTINUOUS
IMPACT BUMPER
.080”
[2mm]
WALLGUARD
HEIGHT PER
PLAN
#10 X 1-3/4”
SHEET METAL
SCREW WITH
ALLIGATOR
ANCHOR
1”
25mm
FROM EACH
END FOR
ANCHORS
FIELD DIMENSION
(TYP ALL WALLS)
SPLICE
OUTSIDE CORNER
INSIDE CORNER
SPACE REMAINING HOLES
DRILLED FROM
EACH END
FOR ANCHORS
IN ZIGZAG PATTERN
EVENLY OVER LG
(10 ANCHORS/12’)
REVEAL
RETURN
DISTANCE TO BE
DETERMINED BY
INSTALLER
4"
4"
1 5/16"
1"
HYMAN
HAYES
ASSOCIATES
6 Wembley Court, Albany, NY 12205
(518) 452-3470 www.hymanhayes.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ARCHITECT:
VA MEDICAL CENTER SYRACUSE
3RD & 4TH fOOR 'D' WING
RENOVATIONS
VAMC, SYRACUSE, NY
528A7-19-708
10/21/2020
C T e m p \R e v it F ile s \S y ra c u s e
V A
D W in g
R e n o v a ti o n s m p a tt e rs o n
C J
.r v t
/3 /2
:5
:5
P
M
1-AS-105
THIRD & FOURTH FLOOR FINISH
PLAN
SCALE: 1/8" = 1'-0"1-AS-105
1 THIRD FLOOR FINISH PLAN
SCALE: 1/8" = 1'-0"1-AS-105
2 FOURTH FLOOR FINISH PLAN
PROJECT
NORTH
PROJECT
NORTH
FINISH LEGEND ABBREVIATIONS
APC ACOUSTICAL PANEL CEILING
AWP ACOUSTICAL WALL PANEL
BB BULLETIN BOARD
CBB CEMENT BOARD
CG CORNER GUARD
CONC CONCRETE
CPT CARPET
CR CHAIR RAIL
CT CERAMIC TILE
DP DECORATIVE PANEL
E- EXISTING
EFTR EXSITING FINISH TO REMAIN
EPX EPOXY PAINT
FF FACTORY FINISH
FTP FABRIC WRAPPED TACK PANEL
FTS FLOOR TRANSITION STRIP
GT GROUT
GWB GYPSUM WALL BOARD
HR HANDRAIL
IR IMPACT RESISTANT GWB
LCK LOCKER
LMC LINEAR METAL CEILING
LVT LUXURY VINYL TILE
MMMR MOISTURE MOLD MILDEW RESISTANT GWB
MT METAL TRIM
NF NATURAL FINSIH
PC PRIVACY CURTAIN
PFT PORCELAIN FLOOR TILE
PL PLASTIC LAMINATE
PLY PLYWOOD
PT PAINT
PWT PORCELAIN WALL TILE
QT QUARTZ SURFACE
RES RESINOUS PANEL
RFC RESINOUS FLOOR…