36C24220Q0349-005.docx

DOCX document Posted

Attached to
J065--630-20-2-4454-0071 | Stryker Stretchers Maintenance (VA-20-00027543)
Solicitation number
36C24220Q0349
Issued by

About this file

36C24220Q0349 36C24220Q0349_1.docx

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project No: 630-20-2-4454-0071 1 3/2/2020

8 3/2/2020 Contract Opportunity Presolicitation Notice

CLASSIFICATION CODE

SUBJECT

CONTRACTING OFFICE'S

ZIP-CODE

SOLICITATION NUMBER

RESPONSE DATE (MM-DD-YYYY)

ARCHIVE

DAYS AFTER THE RESPONSE DATE

RECOVERY ACT FUNDS

SET-ASIDE

NAICS CODE

CONTRACTING OFFICE

ADDRESS

POINT OF CONTACT

(POC Information Automatically Filled from User Profile Unless Entered)

DESCRIPTION

See Attachment

AGENCY'S URL

URL DESCRIPTION

AGENCY CONTACT'S EMAIL

ADDRESS

EMAIL DESCRIPTION

ADDRESS

POSTAL CODE

COUNTRY

ADDITIONAL INFORMATION

GENERAL INFORMATION

PLACE OF PERFORMANCE

* = Required Field Contract Opportunity Presolicitation Notice J065 630-20-2-4454-0071 | Stryker Stretchers Maintenance

(VA-20-00027543)

10468-3904 36C24220Q0349 N 811219 Department of Veterans Affairs Network Contracting Office 2 James J. Peters VA Medical Center 130 West Kingsbridge Road Bronx NY 10468-3904 Marshand Boone https://www.va.gov https://www.va.gov marshand.boone@va.gov marshand.boone@va.gov The Department of Veteran Affairs, Veterans Health Administration, Network Contracting Office 2, Bronx NY intends to award a sole source Firm-Fixed Price contract for maintenance of Stryker Zoom Stretchers Models 1125 and 1025 for the VA New York Harbor Healthcare System (Brooklyn Campus) in accordance with 41 U.S.C. §3304(a)(1) as implemented by FAR 6.302-1 Only One Responsible Source. This is not a request for competitive offers and no solicitation is available. Market research has determined that these services are highly specialized are only available from a single source without an unacceptable delay or duplication of cost and no other type of services will satisfy agency requirements. The Government intends to award the contract on or around 3/20/2020t o Stryker Corporation, 3800 E Centre Ave, Portage, MI 49002-5826.

Stryker Corporation medical division certifies that it is the original equipment manufacturer or sole source distributor of parts for Stryker products. All parts are manufactured at Stryker or by an outside supplier specifically for Stryker. An untrained individual would not have access to the proprietary tools and replacement parts necessary to repair the listed equipment (see attached draft SOW for details).

This synopsis announcement is being issued for information purposes only and does not constitute a solicitation or request for competitive proposals. If a firm believes it is capable of meeting the Government's requirement, it may identify their interest and capability to the Contracting Officer by contacting Marshand Boone via e-mail at marshand.boone@va.gov. Telephone inquiries will not be accepted. Those interested firms must indicate whether they are large, small, small-disadvantaged, 8(a) or woman owned business and whether they are U.S. or foreign owned. Respondents who submit proprietary data shall clearly mark the data with appropriate markings. The Government will not pay for any information submitted as a result of this synopsis. This synopsis shall not be construed as an obligation on the part of the Government to acquire any products or services. Responses are due by Friday, March 6, 2020, at 4 PM EST

New York Harbor Healthcare System Brooklyn, New York

Statement of Work (SOW) – Stryker Zoom Stretchers

Background: The VA NYHHS in Brooklyn, New York is currently seeking a service contract for the maintenance of Stryker Zoom Stretchers Models 1125 and 1025. The contract will have a length of a base period and 4 option years. The base period will be effective from date of award to 12/31/2020. Each option year thereafter will be 1/1-12/31 of the following years.

This Full Service contract is to include all necessary labor, full service, maintenance, tools, equipment, transportation and parts (excluding non-Stryker parts) required to perform repairs, recalls, and Preventive Maintenance (PM) on listed equipment. All equipment shall be maintained in proper operating condition as specified by the manufacturer. Vendor must have manufacturer certification to service and maintain the devices and have access to Original Equipment Manufacturers (OEM) parts, manuals and schematics to perform the service. Vendors must have their own schematics available on site at time of service.

The following stretchers will be covered:

Model #
Serial #
EE#
1025
810099850
139359
1025
810099851
139560
1025
810102538
139325
1025
810102539
139328
1025
810102540
139358
1025
810102541
139356
1025
810102542
139323
1025
810102581
139324
1025
810102583
139353
1025
810102589
139326
1025
810102590
139354
1025
810102591
139357
1025
810102592
139327
1025
810105095
139361
1125
1012033177
156753
1125
1012033178
156759
1125
1012033179
156752
1125
1012033180
156758
1125
1012033203
156755
1125
1012033204
156754
1125
1012033205
156760
1125
1012033206
156756
1125
1012033207
156757
1125
1012033229
156764
1125
1012033230
156765
1125
1012033231
156766
1125
1012033232
156767
1125
1012033233
156768
1125
1012033234
156769
1125
1012033235
156770
1125
1012033236
156771
1125
1012033237
156772
1125
1012033238
156773
1125
1109030556
158844
1125
2018007301010
53328
1125
2018007301011
53329
1125
2018007301012
53330
1125
2018007301013
53331
1125
2019007301053
56855
1125
2019007301055
56859
1125
2019007301058
56856
1125
2019007301059
56858

A. Scope of Work:

1. Contractor is required to furnish all original equipment manufacturer (OEM) parts and labor to provide maintenance of the Zoom Stretchers, in accordance with OEM guidelines. Contractor must have manufacturer certification to service and maintain the above equipment.

2. Contractor shall test the functionality of the equipment upon completion of repair. If this is a test for repair, the Test should ensure that damaged parts have been successfully repaired and all functions including, but not limited to those related to repaired parts, are operational. If this is a test for a routine PM service, inspection, etc., then the test should just ensure that the equipment is functioning within the guidelines of the OEM or the applicable standards (OSHA, ASSE, JCAHO, NEFP, etc).

3. Repair services, including support for recalls, will be provided at the request of the VA to diagnose and correct equipment malfunctions on a routine basis. All repairs shall be performed by a manufacturer-trained technician. Contractor will follow manufacturer's recommendations for PM, repair, calibration and modifications

4. Preventive maintenance: PMs will be scheduled in advance and conducted annually. It is the contractor's responsibility to schedule preventive maintenance as listed. PM procedures subscribed to must follow manufacturer’s specifications and must be documented and submitted in writing to biomedical engineering. Upon completion of PM procedures, an applicable label should be applied to the unit, indicating the date of PM performance, the next date following PM is due, as well as the initials of the individual that performed the PM. At inception of contract, PM shall include, at a minimum, electrical safety testing, lubrication adjustment, calibration, testing and replacement of faulty parts and/or parts which are likely to fail at no additional charge.

5. At the completion of each service call/PM, the contractor will provide a written service report to Biomedical Engineering. This report will clearly show the date of service, type of service performed, model and serial numbers, name of field technician(s) a description of the work performed, a list of any parts replaced, and the unit condition as left at the completion of said work. The contractor has the option of leaving the service report with Biomedical Engineering, Building #4 after servicing equipment or of sending the service report with the invoice. Leaving service reports with a person in the vicinity may be performed in addition to the previously stated requirement but is not to be used as a substitution. Certification of invoices is clearly dependent upon receipt of service reports as proof of services rendered. Payment may be delayed if proper documentation is not provided.

6. Response time: Contractor shall provide a phone call back by a qualified technician within 4 hours of a service request and an onsite response by a qualified technician within 24 hours of original request for service. Technical service personnel are required to sign in and out of engineering service, Bldg #4.

7. Liquidated Damages: Contractor shall be liable to the government for losses of production due to significant equipment downtime. Significant equipment downtime is that which exceeds ten (10) hours/month. Records regarding downtime will be kept by the Contracting Officers technical representative and the maintenance contractor. Equipment downtime is calculated only from those normal hours of coverage (see hours of coverage section), that the scheduled equipment is not fully operational. Downtime will begin when the contractor is required to be on the site after notification by the Contracting Officer, Contracting Officers Representative or designated alternate. Downtime will accumulate until the scheduled equipment is returned to full and usual operation and accepted as such by the contracting officer, contracting technical representative or designated alternate. If downtime exceeds sixteen (16) consecutive hours, the contracting officer may exercise the option to hire and alternate source to resolve the problem. The decision to exercise this alternative will reside exclusively with the contracting officer. All fees generated by the alternate contractor(s) will be handled in accordance with default clause.

8. Privacy and Security: All contractor employees and subcontractors under this contract or order are required to complete the VA's on-line “VA Privacy and Information Security Awareness and Rules of Behavior Training” - TMS Code “10176”. Contractors must provide signed certifications of completion to the COR during each year of the contract. This requirement is in addition to any other training that may be required of the contractor and subcontractor(s).”

In the event that equipment/medical systems containing media (hard drives, optical disks, etc.) with VA sensitive information need to be taken off-site for repair or to be replaced – the media must not be returned to the vendor; the options are as follows:

a) Vendor must accept the system without the drive;

b) VA’s initial medical device purchase includes a spare drive which must be installed in place of the original drive at time of turn-in; or

c) VA must reimburse the company for media at a reasonable open market replacement cost at time of purchase.

9. VENDOR MUST COMPLY WITH:

VA HANDBOOK 6500.6 MARCH 12, 2010 APPENDIX C C-9 (4) Due to the highly specialized and sometimes proprietary hardware and software associated with medical equipment/systems, if it is not possible for the VA to retain the hard drive, then;

The equipment vendor must have an existing BAA if the device being traded in has sensitive information stored on it and hard drive(s) from the system are being returned physically intact; and Any fixed hard drive on the device must be non-destructively sanitized to the greatest extent possible without negatively impacting system operation. Selective clearing down to patient data folder level is recommended using VA approved and validated overwriting technologies/methods/tools. Applicable media sanitization specifications need to be pre- approved and described in the purchase order or contract.

A statement needs to be signed by the Director (System Owner) that states that the drive could not be removed and that (a) and (b) controls above are in place and completed. The ISO needs to maintain the documentation.

10. The C&A requirements do not apply, and that a Security Accreditation Package is not required

B. Safety Requirements

To be for consideration, offerors will have been engaged in maintaining/servicing the equipment listed for a period of no less than two (2) years (on model listed) and be capable of presenting certification of. No allowance will be made for the contractor not having qualified personnel available to respond as specified in this contract at all times with-in the contract period.

The Contracting Officer or his/her designee will notify the contractor of any noncompliance with the foregoing provisions and the action to be taken. The Contractor shall, after receipt of such notice, immediately correct the conditions to which attention has been directed. Such notice, when served on the Contractor or his/her representative at the site of the work, shall be deemed sufficient for the purpose aforesaid. If the Contractor fails or refuses to comply promptly, the Contracting Officer may issue an order stopping all and any part of the work and hold the Contractor in default.

C. Period of Performance

Contract hours will be 8:00AM-4:30PM, Monday-Friday, excluding Government Holidays

D. Place of performance

VAMC Brooklyn Campus, 800 Poly Place, Brooklyn, NY 11209

E. Inspection

If services do not include equipment, then an inspection shall be done by the VA COR/POC upon completion. (Window washing, Janitorial, tree cutting, snow removal, waste removal. The COR/POC will perform the inspection in the presence of the contractor personnel, prior to the contractor personnel leaving the facility. No invoices will be processed for payment prior to the completion of POC inspection. If the service is routine and/or performance based then inspections may not occur for every service date but may occur periodically as part of a Quality Assurance Surveillance Plan (QASP). If this is the case then a QASP will need to be provided as a separate document.

F. Drawings, and Other Attachments

N/A

G. Government Furnished Property

N/A

H. Other Related Services (Not Included in the Scope of Work)

Any services not expressly stated in this statement of work are not authorized. Services such as inspection, Original Equipment Manufacturer (OEM) required maintenance, or other maintenance and repair vital to the continued functioning of the systems may be added only after written modification from the contracting officer. No other person, including the COR or any other VA personnel are authorized to request additional work be performed by the contractor. Any additional services performed that are not authorized by the contracting officer will be considered inclusive.

Page 1 of

Page 1 of

File details come from the government source that posted it. Updated .