NOTES:

- REINFORCING: AS SPECIFIED,

PEERLESS CONCRETE PRODUCTS

246 MAIN STREET

BUTLER, NJ 07405

973-838-3060

WWW.PEERLESSCONCRETE.COM

VARIES

60" DIA. SANITARY MANHOLE

GRADE 60 REBAR

- CONCRETE 5,000 PSI @ 28 DAYS

- LOAD RATING: HS-20

RISER SECTION

- STEPS: DOT APPROVED, STEEL REINFORCED

POLYPROPLENE COATED

- MANUFACTURED IN ACCORDANCE

WITH ASTM C-478

TOP VIEW

SIDE VIEW

FLAT TOP

FLAT TOP

CUSTOM DOGHOUSE

AutoCAD SHX Text

CONTRACTOR:

AutoCAD SHX Text

JOB:

AutoCAD SHX Text

STRUCTURE: 60" DIA. MANHOLE

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text 6"

AutoCAD SHX Text 60"

AutoCAD SHX Text 6"

AutoCAD SHX Text

30"OR AS REQUIRED

AutoCAD SHX Text

#5 REBAR @ 6" O/C B/W

AutoCAD SHX Text 60"

AutoCAD SHX Text 72"

AutoCAD SHX Text 12"

AutoCAD SHX Text 8"

AutoCAD SHX Text

30" OR AS REQUIRED

AutoCAD SHX Text

TWO ADDITIONAL #5 REBAR AROUND OPENING ALL SIDES

AutoCAD SHX Text

VARIES

AutoCAD SHX Text 8"

AutoCAD SHX Text

30"OR AS REQUIRED

AutoCAD SHX Text

#5 REBAR @ 6" O/C B/W

AutoCAD SHX Text

DOGHOUSE OPENING

AutoCAD SHX Text

0.12 SQ. IN. PER VERT. FT. CIRCUMFERENTIAL REINFORCEMENT (SIDE WALLS)

AutoCAD SHX Text

EXTERIOR COATED