36C24219B0037-004.pdf
PDF 11 MB Posted
- Solicitation number
- 36C24219B0037
About this file
36C24219B0037 630A4_MH-00100-signed.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24219B0037-0003003.pdf | ||
| 36C24219B0037-0003000.docx | DOCX document | |
| 36C24219B0037-0003001.pdf | ||
| 36C24219B0037-0003002.pdf | ||
| 36C24219B0037-0002001.pdf | ||
| 36C24219B0037-0002000.docx | DOCX document | |
| 36C24219B0037-0001000.docx | DOCX document | |
| 36C24219B0037-003.pdf | ||
| 36C24219B0037-005.pdf | ||
| 36C24219B0037-009.pdf | ||
| 36C24219B0037-011.pdf | ||
| 36C24219B0037-008.pdf | ||
| 36C24219B0037-001.docx | DOCX document | |
| 36C24219B0037-002.pdf | ||
| 36C24219B0037-010.pdf | ||
| 36C24219B0037-006.pdf | ||
| 36C24219B0037-007.pdf | ||
| 36C24219B0037-000.docx | DOCX document |
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SYMBOL LIST AND ABBREVIATIONS
EXISTING WORK TO REMAIN
DIRECTION OF FLOW
NEW WORK
FLEXIBLE CONNECTION
FIRE & SMOKE DAMPERS W/ACCESS DOOR
RECTANGULAR ELBOW WITH TURNING VANES
IN DUCT AT WALL
FC
FC
RETURN OR EXHAUST DUCT DOWN
RETURN OR EXHAUST DUCT UP
SUPPLY DUCT DOWN
SUPPLY DUCT UP
CEILING DIFFUSER
CEILING REGISTER
MOTORIZED DAMPER
TEMPERATURE SENSOR
CEILING DIFFUSER W/150 CFM SUPPLY AIR CD CD(150)
ACOUSTICAL LINED DUCT
VOLUME DAMPER
VD
VD
VD
STRAINER WITH BLOW-OFF VALVE
UNION
REDUCER
THREE WAY CONTROL VALVE
COMBINATION MEASURING, BALANCING &
SOLENOID VALVE
COCK VALVE
GATE VALVE / SHUT-OFF VALVE
GLOBE VALVE
CHECK VALVE
WATER PRESSURE GAUGE
TWO WAY CONTROL VALVE
THERMOMETER
BUTTERFLY VALVE
PIPE DOWN
PIPE UP
END CAP
SHUT-OFF VALVE
CAV-6
(600)
CAV
EXISTING WORK TO BE DEMOLISHED
SG
RG
SG(300)
RG(300)
SUPPLY AIR GRILLE 300 CFM
RETURN AIR GRILLE 300 CFM
CONSTANT AIR VOLUME BOX W/REHEAT COIL #
6, 600 CFM
HUMIDITY SENSOR
POINT OF CONNECTION NEW TO EXISTING
POINT OF DISCONNECTION FOR REMOVAL
LOW PRESSURE RETURN
MEDIUM PRESSURE RETURN
HIGH PRESSURE STEAMHPS
MPR
LOW PRESSURE STEAM
EXHAUST AIR
ACCESS DOOR
SYMBOL LIST AND ABBREVIATIONS
CUBIC FEET PER MINUTE
ABOVE FINISHED FLOOR
GALLON PER MINITE
ACOUSTICAL LINING
300 CUBIC FEET OF AIR PER MINUTE
CEILING GRILLE
BRITISH THERMAL UNIT
BUILDING AUTOMATION SYSTEM
CEILING DIFFUSER
CEILING REGISTER
HORSE POWER
HEATING COIL
LEAVING WATER TEMPERATURE
LOCKED ROTOR AMPS
LEAVING AIR TEMPERATURE
LRA
LWT
KW
HP
LAT
GPM
HC
EA
DN
CR
KILOWATT
DOWN
CFM
CD
CG
BTU
BAS
AFF
AL
AD
(300)
VFD
W/WMS
WMS
CAV
VARIABLE FREQUENCY DRIVE
WIRE MESH SCREEN
WITH WIRE MESH SCREEN
CONSTANT AIR VOLUME
LVG LEAVING
EEF EFFICIENCY
DWG DRAWING
FC FLEXIBLE CONNECTION
HEATINGHTG
DDC DIRECT DIGITAL CONTROL
FPM FEET PER MINUTE
FT FEET
ELEV ELEVATION
FSD FIRE/SMOKE DAMPER
CHWS
CHWR CHILLED WATER RETURN
CHILLED WATER SUPPLY
OUTSIDE AIR INTAKE
OUTSIDE AIR
NOT TO SCALE
NORMALLY CLOSED
NOT IN THIS CONTRACT
OAI
OA
NTS
NIC
NC
MIN MINIMUM
SA
RA
SUPPLY AIR
RETURN AIR
TYP TYPICAL
MECH MECHANICAL
DET DETAIL
FTR FIN TUBE RADIATION
MAT MIXED AIR TEMPERATURE
MAX MAXIMUM
MBH THOUSANDS BTU PER HOUR
MD MOTORIZED DAMPER
RHC REHEAT COIL
WPD WATER PRESSURE DROP
ABBREV. SYMBOL DESCRIPTIONS ABBREV. SYMBOL DESCRIPTIONS
FSD/AD, SFD, FSD,
F/SD
1. ALL PIPING AND DUCTWORK SHALL BE SUSPENDED FROM BUILDING STRUCTURE ONLY, EXCEPT AS SPECIFICALLY ALLOWED IN THE SPECIFICATIONS. HVAC CONTRACTOR SHALL PROVIDE SUPPLEMENTARY STEEL AS NECESSARY TO SUPPORT PIPES AND DUCTS FROM BUILDING STRUCTURE. THE ARCHITECT AND STRUCTURAL ENGINEER SHALL BE THE SOLE DETERMINANT AS TO PERMISSIBILITY OF HANGING NEW WORK FROM BUILDING STRUCTURE AND SLABS.
2. PIPING AND DUCTWORK PROVIDED UNDER THIS CONTRACT SHALL BE COORDINATED UNDER THIS CONTRACT WITH
WORK BEING PROVIDED BY OTHER TRADES.
3. FINAL LOCATION OF ALL CEILING DIFFUSERS, RETURN REGISTERS AND CEILING GRILLES SHALL BE AS SHOWN ON THE ARCHITECTURAL DRAWINGS. QUANTITIES OF THESE DEVICES SHALL BE PROVIDED AS SHOWN ON THE HVAC DRAWINGS.
ANY DISCREPANCIES BETWEEN THE HVAC DRAWINGS AND THE ARCHITECTURAL DRAWINGS SHALL BE BROUGHT TO THE
ATTENTION OF THE ARCHITECT FOR RESOLUTION PRIOR TO BID.
4. WHILE THE DRAWINGS SHALL BE ADHERED TO AS CLOSELY AS POSSIBLE, THE ARCHITECT'S RIGHT IS RESERVED TO VARY THE RUN AND SIZE OF DUCTS DURING THE PROGRESS OF THE WORK IF REQUIRED TO MEET CEILING HEIGHTS, TO MEET STRUCTURAL AND FIELD CONDITIONS. CONTRACTOR SHALL PROVIDE REDRAWING OF SHOP DRAWINGS AS NECESSARY TO ACCOMMODATE THE ARCHITECT'S REQUIREMENTS, AT NO ADDITIONAL COST TO THE OWNER. REFER TO
ARCHITECTURAL REFLECTED CEILING PLANS FOR REQUIRED CEILING HEIGHTS.
5. INSTALL ALL DUCTWORK IN STRICT ADHERENCE TO THE CEILING HEIGHTS INDICATED ON THE ARCHITECT'S DRAWINGS.
CONSULT WITH OTHER CONTRACTORS AND IN CONJUNCTION WITH THE OTHER CONTRACTORS, ESTABLISH THE
NECESSARY SPACE REQUIREMENTS FOR EACH TRADE.
6. THE SHEET METAL DUCTWORK SHALL, WHETHER INDICATED OR NOT, RISE AND/OR DROP AND/OR CHANGE IN SHAPE TO CLEAR ANY AND ALL OTHER DUCTWORK, CONDUITS, LIGHTING FIXTURES, PLUMBING AND HEATING/COOLING MAINS TO MAINTAIN THE DESIRED CEILING HEIGHTS AND TO PROVIDE ADEQUATE MAINTENANCE ROOM AND HEADROOM IN MECHANICAL EQUIPMENT ROOMS. THE DRAWINGS, IN GENERAL, DO NOT SHOW ALL RISES, DROPS AND DUCT
TRANSITIONS REQUIRED. THE DRAWINGS SHOW GENERAL ROUTING REQUIREMENTS ONLY.
7. ALL RECTANGULAR DUCTWORK, UNLESS OTHERWISE NOTED, SHALL BE BUILT FROM GALVANIZED SHEET STEEL AND THOROUGHLY BRACED AND STIFFENED. SEE SPECIFICATIONS FOR DUCTS REQUIRED TO BE FABRICATED OF ALUMINUM AND STAINLESS STEEL. ALL DUCTS WITH ROOMS WITH OPEN TANKS SHALL BE STAINLESS STEEL.
8. PROVIDE A MANUAL VOLUME DAMPER UPSTREAM OF EACH VAV/CAV TERMINAL BOX WHETHER INDICATED OR NOT ON THE DRAWINGS. PROVIDE AN ACCESS DOOR LOCATED BETWEEN VAV/CAV TERMINAL BOX AND VOLUME DAMPER.
PROVIDE ACCESS DOOR IMMEDIATELY DOWNSTREAM OF ANY VAV/CAV BOX REHEAT COIL, WITH BOX BEING PROVIDED
WITH AD UPSTREAM OF REHEAT COIL.
9. ALL VALVES, REHEAT COIL, TERMINAL BOXES (VAV AND CV), DAMPERS AND OTHER EQUIPMENT LOCATED ABOVE THE CEILING, WHICH REQUIRE MAINTENANCE, SHALL BE LOCATED SO AS TO PERMIT MAINTENANCE. IN HIGH FLOOR TO FLOOR AREAS, THIS EQUIPMENT SHALL BE LOCATED AS LOW AS POSSIBLE IN THE CEILING CAVITY FOR EASIER ACCESS. LOCATE SUCH EQUIPMENT ABOVE ACCESSIBLE CEILINGS TO THE EXTENT POSSIBLE TO AVOID ACCESS DOORS IN THE CEILING.
10. PROVIDE ISOLATION VALVES WHERE TYING NEW PIPING INTO THE EXISTING SYSTEM. REFER TO THE VALVES SPECIFICATIONS FOR THE PROPER VALVE TYPE FOR THE SERVICE. REFER TO THE DRAWINGS FOR THE PIPE/VALVE SIZE.
IN ADDITION TO THE ISOLATION VALVES AT THE TIE-IN POINTS, ALSO PROVIDE A BALANCING VALVE ON THE SUPPLY SIDE FOR CHILLED WATER, CHILLED GLYCOL/BRINE, CONDENSER WATER AND HEATING/REHEAT HOT WATER SYSTEM TIE-INS.
11. ALL BIDDERS ARE REQUIRED TO REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OF ALL MEP/FP COMPONENTS FOR FULL INTEGRATION INTO ARCHITECTURAL DESIGN. BIDDERS ARE TO IMMEDIATELY CALL TO THE ARCHITECT'S ATTENTION ANY DISCREPANCIES IN QUANTITIES, TYPES AND SCOPE FOR ALL DISCIPLINES/TRADES.
12. SEE ARCHITECTURAL REFLECTED CEILING PLAN (RCP), DRAWINGS AND FLOOR PLANS FOR LOCATION OF ALL CEILING MOUNTED DEVICES. SEE ARCHITECTURAL DRAWINGS FOR LOCATION OF ALL WALL MOUNTED DEVICES.
13. SYMBOLS AND ABBREVIATIONS SHOWN ON THE DRAWINGS ARE FOR MECHANICAL DRAWINGS ONLY. SEE ARCHITECTURAL DRAWING AND OTHER TRADES DRAWINGS FOR THEIR RESPECTIVE SYMBOLS AND ABBREVIATIONS.
14. PRIOR TO PERFORMING ANY CORE DRILLING OR CUTTING OF EXISTING FLOOR OR ROOF SLAB, CONTRACTOR SHALL PERFORM A SCAN OF THE SLAB USING GROUND PENETRATING RADAR (GPR) TO CONFIRM THAT THERE ARE NO EXISTING
CONDUITS OR PIPES IN THE AREA OF CORE DRILL OR CUTTING OF THE SLAB.
15. SEE ARCHITECTURAL DWG AS101 FOR PHASING NOTES.
1. DEMOLITION OF HVAC ITEMS SHALL BE PERFORMED UNDER THE HVAC CONTRACT.
2. LOCATION OF THE EXISTING DUCTWORK & PIPING AS SHOWN ON DRAWINGS IS APPROXIMATE.
3. PROVIDE TEMPORARY SUPPORTS WHERE REQUIRED.
4. DURING DEMOLITION, PROPERLY CAP AND PROTECT ALL DUCTWORK, EQUIPMENT, AND PIPING THAT WILL REMAIN IN OPERATION.
5. WHERE EXISTING INSULATION TO REMAIN IS DAMAGED BY THE REQUIREMENTS OF THE WORK, REPLACE ANY DAMAGED INSULATION TO
MATCH EXISTING.
6. DEMOLISH ALL EQUIPMENT AS INDICATED, FIXTURES AND/OR MISCELLANEOUS ARTICLES IN THEIR ENTIRETY INCLUDING AUXILIARY
EQUIPMENT, PIPING, WIRING, CONDUIT AND DUCTWORK.
7. MATERIALS RESULTING FROM THE DEMOLITION OPERATIONS SHALL NOT BE ALLOWED TO ACCUMULATE ON THE FLOORS AND ROOF SURFACES, EXTERIOR GRADE SURFACES OR OTHER PARTS OF THE PREMISES, AND SHALL BE PROMPTLY REMOVED AND DISPOSED OF
AWAY FROM THE PREMISES.
8. INCLUDE ALL DEMOLITION OF SYSTEMS AND COMPONENTS WHERE SYSTEMS SHALL BE REPLACED BY NEW WORK. REFER TO THE DRAWINGS AND SPECIFICATIONS FOR THE SCOPE OF NEW AND RECONNECTED WORK. THE INTENT OF THIS REQUIREMENT IS TO HAVE THE CONTRACTOR DISCONNECT, DEMOLISH AND REMOVE ALL EXPOSED AND CONCEALED WORK WHERE BEING REPLACED OR
CONNECTED TO THE NEW LAYOUTS.
9. COORDINATE ELECTRICAL POWER DISCONNECTION PRIOR TO DEMOLITION WITH ELECTRICAL CONTRACTOR.
10. PROTECT ALL HVAC WORK AND WORK OF OTHER TRADES WHICH IS TO REMAIN, FROM DAMAGE DURING DEMOLITION.
11. ALL PIPING AND DUCTWORK TO REMAIN SHALL HAVE ENDS TERMINATED IN A NEAT MANNER READY FOR CONNECTION OF NEW WORK.
ALL EXPOSED ENDS OF PIPING AND DUCTWORK SHALL BE CAPPED. SCREWED PIPING SHALL END ON A SCREWED JOINT. FLANGED PIPE SHALL END WITH A FLANGED JOINT. WELDED PIPING SHALL BE MECHANICALLY CUT, CLEANED OF BURRS AND A CAP WELDED TO THE
PIPE. DUCTWORK SHALL BE CAPPED WITH SHEET METAL CONNECTED TO THE DUCT TO REMAIN.
12. REMOVAL OF EQUIPMENT, PIPING AND DUCTWORK SHALL INCLUDE ALL HANGERS & SUPPORT ASSOCIATED WITH THE EQUIPMENT, PIPING AND DUCTWORK TO BE REMOVED.
GENERAL NOTES:
GENERAL DEMOLITION NOTES:
NOTE:
SYMBOLS AND ABBREVIATIONS LISTED IN THE TABLES ABOVE ARE TYPICAL FOR HVAC AIR AND WATER DISTRIBUTION SYSTEMS. NOT ALL OF LISTED SYMBOLS OR ABBREVIATIONS WERE USED IN THIS PROJECT.
EF EXHAUST FAN
LAB EXHAUST FANLE
AIR HANDLERAH
FFU FAN FILTER UNIT
CONDENSATE PUMPCP
SG STEAM GENERATOR
INCHES OF WATER GAUGEIN. W.G.
T
H
DP DIFFERENTIAL PRESSURE SENSOR
LPS
LPR
FFU-1
(400) FAN FILTER UNIT FFU-1, 600 CFM
INDUCTION UNITIU
PUMP CONDENSATEPC
SECONDARY WATER SUPPLYSWS
SECONDARY WATER RETURNSWR
DRAIND
LOW PRESSURE RETURNLPR
STEAM TRAP
TH COMBINED TEMPERATURE AND
HUMIDITY SENSORS
1-MH001
SYMBOLS, ABBREVIATIONS
AND GENERAL NOTES
J.O. N.R.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
100% CDOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
MEP Consultant:
Project Director
05 Feb 2019Revisions: Date:
630A4-17-490
800 POLY PLACE, BROOKLYN, NY
RENOVATE ONCOLOGY
PHARMACY
MICHAEL AVRAMIDES ARCHITECT
319 E 50TH STREET, STUDIO E
NEW YORK, NY 10022
T:917.855.8111
ONSULTING NGINEERS
KALLEN & LEMELSON, LLP
P: (212) 643-9898 F: (212) 643-2332
IGHTH VENUE, TH LOOR, EW ORK, 520 E
A 17 F N Y
C E
NY 10018
(E) 42x42 DN
(E) 42x42 UP 42x42
42x42 28x20
33x9
33x9
33x9
12x10 12x612x8 12x5
12"Ø
12"Ø
12"Ø
12"Ø
12"Ø
12"Ø
12"Ø
12"Ø
33x8
(E) IU (E) IU (E) IU (E) IU (E) IU (E) IU
(E) IU (E) IU
(E) 25x23
SUPPLY
(E) 25x25
SUPPLY
(E) 12x6 CR (150)
(E) 12x6 CR (100)
(E) 12x12 CR (250)
12x4
SWSSWS SWS SWS SWS
SWR SWR SWR SWR SWR SWR
SWS
(E) IU- EXISTING INDUCTION UNIT
(E) 1¼" MPR
(E) 6" SCR
(E) 8" SWR
(E) 6" CHWR
(E) LPR
(E) 6"HPS
(E) 6" CHWS
DISCONNECT AND REMOVE
STEAM FIN TUBE RADIATION AND
CONVECTOR COVER
DISCONNECT AND REMOVE
STEAM FIN TUBE RADIATION AND
CONVECTOR COVER
(E) FD
(E) FD
(E) FD
KEY MAP - BLDG 1 : 8TH FLOOR
8TH FLOOR DEMOLITION HVAC PART PLAN
1-MD101
J.O. N.R.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
100% CDOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
MEP Consultant:
Project Director
05 Feb 2019Revisions: Date:
630A4-17-490
800 POLY PLACE, BROOKLYN, NY
RENOVATE ONCOLOGY
PHARMACY
MICHAEL AVRAMIDES ARCHITECT
319 E 50TH STREET, STUDIO E
NEW YORK, NY 10022
T:917.855.8111
ONSULTING NGINEERS
KALLEN & LEMELSON, LLP
P: (212) 643-9898 F: (212) 643-2332
IGHTH VENUE, TH LOOR, EW ORK, 520 E
A 17 F
N Y
FOR MECH ROOM LAYOUT
SEE DWG. MH--500
NOTE:
1. CONTRACTOR SHALL RELOCATE ALL EXISTING PIPING AND CONDUITS AS
REQUIRED TO INSTALL NEW WORK.
2. LINE OF PHASE 1 TEMPORARY CONSTRUCTION BARRIER SEE DWG. AD101.
3. REFER TO DWG. AS101 AND SPECIFICATIONS FOR PHASING SEQUENCE OF
DEMOLITION AND NEW WORK.
26x12
(E) 42x42 DN
(E) 42x42 UP 42x42
42x42 28x20
33x9
33x9
33x9
12x10 12x612x8 12x5
12"Ø
12"Ø
12"Ø
12"Ø
12"Ø
12"Ø
12"Ø
12"Ø
33x8
(E) IU
(E) IND
(E) 25x23
SUPPLY
(E) 25x25
SUPPLY
(E) 12x6 CR (150)
(E) 12x6 CR (100)
(E) 12x12 CR (250)
12x4
SWSSWS SWS SWS SWS
SWR SWR SWR SWR SWR SWR
SWS
(E) 1¼" MPR
(E) 6" SCR
(E) 8" SWR
(E) 6" CHWR
(E) LPR
(E) 6"HPS
(E) 6" CHWS
5 1/8"Ø
CAV-4
(300)
CD
(300)
FFU-3
(800)
16x10CAV-2 (800)16x10
24x1214x1212x8
12x8 7 1/8"Ø
FFU-4
(700)
14x10
CAV-3
(700)
14x10
12x10
CAV-1
(460)
FC
14x12
CAV-10
(160)
14x10
FFU-1
(460)
FFU-2
(460)
VD
8x8
CAV-6
(500)
VD
12x10
14x1212x8 VD
CR
(350)
14x10 14x10
12x8
8x8
8x812x8
12x8
8x8
8x8
CAV-12
(310)
12x8
CAV-7
(100)
CAV-8
(380)
CR
(380)
12x8
12x8 12x8 12x8
CAV-11
(700)
14x12
FC
FC
M
MOTORIZED RELIEF
AIR DAMPER
PLENUM 36x24x1210x8 DN 8x8 BR 6" AFF
RF-1
(1010) 14x12
14x10 DN 12x10 BR 6" AFF
CAV-9
(100)
8x8
CR
(100)
CR
(100)
(680) (620)
12" Ø ID, 14Ø OD STAINLESS STEEL
EXHAUST DUCT FOR CONTINUATION
OF SS DUCT SEE DWG MP-102
16x10 8x8
16x10 DN 14x10 BR 6" AFF
CAV-5
(350)
FFU-5
(500)
16x10 DN 14x10 BR
6" AFF
12x8
12x8
T
DP
DP
DP
DP
TH
TH
TH
DN
(E) FD
(E) FD
(E) FD
OFFICE
ANTE ROOM
STERILE
COMPOUNDING
STORAGE
(191.25 SQ. FT.)
37.3 AC/H
POSITIVE PRESSURE
+0.02" W.G.
(166 SQ. FT.), 57.8 AC/HR
POSITIVE PRESSURE
+.02" W.G.
(198 SQ. FT.), 11.4 AC/HR
NEGATIVE TO CORRIDOR
NEGATIVE PRESSURE
-0.01" W.G.
(54 SQ. FT.), 14.8 AC/HR
NEGATIVE PRESSURE
-0.01" W.G.
EXHAUST AIR
(1000 CFM)
EXHAUST AIR
(100 CFM)
TOTAL SUPPLY 2260 CFM
TOTAL EXHAUST 300 CFM
TOTAL RETURN 1510 CFM
ISO 7
CLEAN ROOM
RETURN AIR
(350 CFM)
SUPPLY AIR
(300 CFM)
TRANFER AIR
(50 CFM)
TRANSFER AIR
(100 CFM)
TRANSFER AIR
(200 CFM)
RETURN AIR
(500 CFM)
SUPPLY AIR
(700 CFM)
TRANSFER AIR
(200 CFM)
RECIRCULATION
AIR (700 CFM)
TRANSFER AIR
(200 CFM)
CHEMO BUFER ROOM
(155 SQ. FT.), 41.3 AC/HR
NEGATIVE PRESSURE
-0.02" W.G.
ISO 7
CLEAN ROOM
SUPPLYAIR
(800 CFM)
SUPPLY AIR
(460 CFM)
RECIRCULATION
AIR (500 CFM)
EXHAUST AIR
(100 CFM)
RETURN AIR
(160 CFM)
ISO 7
CLEAN ROOM
KEY MAP - BLDG 1 : 8TH FLOOR
8TH FLOOR NEW HVAC PART PLAN
1-MH101
J.O. N.R.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
100% CDOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT MEP Consultant:
Project Director
05 Feb 2019Revisions: Date:
630A4-17-490
800 POLY PLACE, BROOKLYN, NY
RENOVATE ONCOLOGY
PHARMACY
MICHAEL AVRAMIDES ARCHITECT
319 E 50TH STREET, STUDIO E
NEW YORK, NY 10022
T:917.855.8111
ONSULTING NGINEERS
KALLEN & LEMELSON, LLP
P: (212) 643-9898 F: (212) 643-2332
IGHTH VENUE, TH LOOR, EW ORK, 520 E
A 17 F
N Y
(2) 14"Ø WELDED
12" ID & 14" OD
316 STAINLESS
STEEL EXHAUST
DUCT DOWN3'-7" HIGH
PARAPET
FENCE
CHEMO EF-1
ON 12" HIGH CURB
NOTE:
SCAFFOLDING AND SIDEWALK
SHED AND BRIDGING ARE
REQUIRED FOR INSTALLATION OF
THE EXTERIOR CONDUITS AND
DUCTWORK.
VFD'S
FENCE
14" EXHAUST DUCT
TO FAN ON ROOF
CHEMO EF-2
ON 12" HIGH CURB
VFD'S.
FOR LOCATION
OF VFD'S, SEE
ELEC. DWG.
1-EP102
14" EXHAUST DUCT
TO FAN ON ROOF
STAINLESS STEEL DUCT SUPPORT EVERY
10 FT. SEE DWG. MH-703 DETAIL 21.
NOTES:
1. LENGTH OF DUCT 322'
FROM FAN TO WINDOW
3'-7" HIGH
PARAPET
(2) 12"Ø ID, 14"Ø OD 316 STAINLESS STEEL
MANUFACTURED EXHAUST DUCT
STAINLESS STEEL DUCT SUPPORT EVERY
10 FT. SEE DWG. MH-703 DETAIL 21.
(2)12"Ø ID, 14"Ø OD 316 STAINLESS STEEL
MANUFACTURED EXHAUST DUCT
BYPASS AIR
PLENUM
12" ROOF
(TYPICAL)
CHEMO EF-2
ROOF
134.00
CHEMO EF-1
14" EXHAUST DUCT
TO FAN ON ROOF
14"Ø FENCE
ROOF HVAC PART PLAN & ELEVATION
FOR LAB EXHAUST
1-MH102J.O. N.R.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
100% CDOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
MEP Consultant:
Project Director
05 Feb 2019Revisions: Date:
630A4-17-490
800 POLY PLACE, BROOKLYN, NY
RENOVATE ONCOLOGY
PHARMACY
MICHAEL AVRAMIDES ARCHITECT
319 E 50TH STREET, STUDIO E
NEW YORK, NY 10022
T:917.855.8111
ONSULTING NGINEERS
KALLEN & LEMELSON, LLP
P: (212) 643-9898 F: (212) 643-2332
IGHTH VENUE, TH LOOR, EW ORK, 520 E
A 17 F
N Y
C E
NY 10018
KEY MAP - BLDG 1 : 8TH FLOOR
ROOF PART PLAN
SECTION PART PLAN
12"Ø
SWS
SWR
SWS
6" HIGH CONCRETE CURB PAINTED
SAFETY YELLOW, SEE A-5-200 FOR
DETAILS
AHU-1
NEW AIR CONDITIONING UNIT
AHU-1 TO BE INSTALLED
SD
INTEGRAL FACE AND BYPASS
STEAM COIL
CHILLED WATER COIL
HUMIDIFIER SECTION
FAN
FILTERS
(E) 42x42 DN
(E) 42x42 UP 42x42
42x42 28x20
33x9
33x9
33x9
12x10 12x612x8 12x5
12"Ø
12"Ø
12"Ø
12"Ø
12"Ø
12"Ø
12"Ø
12"Ø
33x8
(E) IU
(E) IU
(E) 25x25
SUPPLY
(E) 12x6 CR (150)
(E) 12x6 CR (100)
(E) 12x12 CR (250)
12x4
SWSSWS SWS SWS SWS
SWR SWR SWR SWR SWR SWR
SWS
(E) 1¼" MPR
(E) 6" SCR
(E) 8" SWR
(E) 6" CHWR
(E) LPR
(E) 6"HPS
(E) 6" CHWS
3/4"
3/4"
1¼"HWS&R
HWS&R
FROM HX
1" MPR
1" HPS
3/4"
RHC-4
RHC-2
RHC-3
RHC-1
1"HWS&R
1"
1½" CHWS&R
TRAP 1" MPC TO
FLUSH TANK
1½" CHWS&R
1" MPR
1" HPS
FOR MECH ROOM LAYOUT
OF PIPING AND DUCTWORK
SEE DWG. MH--500
FOR HVAC DUCTWORK IN
THIS AREA SEE MH-101
1"MPC
TRAP 1" MPC TO
FLUSH TANK
1½" CHWS&R
3/4"
3/4"
KEY MAP - BLDG 1 : 8TH FLOOR
8TH FLOOR HVAC PIPING PLAN
1-MP103
J.O. N.R.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
100% CDOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
MEP Consultant:
Project Director
05 Feb 2019Revisions: Date:
630A4-17-490
800 POLY PLACE, BROOKLYN, NY
RENOVATE ONCOLOGY
PHARMACY
MICHAEL AVRAMIDES ARCHITECT
319 E 50TH STREET, STUDIO E
NEW YORK, NY 10022
T:917.855.8111
ONSULTING NGINEERS
KALLEN & LEMELSON, LLP
P: (212) 643-9898 F: (212) 643-2332
IGHTH VENUE, TH LOOR, EW ORK, 520 E
A 17 F
N Y
HVAC
SCHEDULES 1
1-MH401
J.O. N.R.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
100% CDOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
MEP Consultant:
Project Director
05 Feb 2019Revisions: Date:
630A4-17-490
800 POLY PLACE, BROOKLYN, NY
RENOVATE ONCOLOGY
PHARMACY
MICHAEL AVRAMIDES ARCHITECT
319 E 50TH STREET, STUDIO E
NEW YORK, NY 10022
T:917.855.8111
ONSULTING NGINEERS
KALLEN & LEMELSON, LLP
P: (212) 643-9898 F: (212) 643-2332
IGHTH VENUE, TH LOOR, EW ORK, 520 E
A 17 F N Y
HVAC
SCHEDULES 2
1-MH402
J.O. N.R.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
100% CDOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
MEP Consultant:
Project Director
05 Feb 2019Revisions: Date:
630A4-17-490
800 POLY PLACE, BROOKLYN, NY
RENOVATE ONCOLOGY
PHARMACY
MICHAEL AVRAMIDES ARCHITECT
319 E 50TH STREET, STUDIO E
NEW YORK, NY 10022
T:917.855.8111
ONSULTING NGINEERS
KALLEN & LEMELSON, LLP
P: (212) 643-9898 F: (212) 643-2332
IGHTH VENUE, TH LOOR, EW ORK, 520 E
A 17 F
N Y
6" HIGH CONCRETE
CURB PAINTED SAFETY YELLOW,
SEE A-5-200 FOR DETAILSAC-1
NEW AIR CONDITIONING UNIT AC-1 TO BE INSTALLED
1" HPS
1" PC
2"Ø COPPER ATMOSPHERIC
STEAM TO HUMIDIFIER
STEAM EXCHANGE
STEAM GENERATOR SG-1,
WALL MOUNTED 3'-0 " AFF
20x10
20x10 DN TO UNIT W/FC
(2400)
CONDENSATE PUMP CP-1
ON 4" CONCRETE PAD
PAINTED YELLOW
SD
PRV VALVE ASSEMBLY
(10"-0" LONG 9'-0" AFF)
FLASH TANK WESSELS
FTA-6V 4 GALLONS VERTICAL
FLASH TANK OR EQUAL.
1/2" LPC
TO CP-1
1" LPC
1/2" LPS
40" x 52" x 28" D PLENUM
1" PC
1"Ø COOLING COIL CONDENSATE TO
DRAIN
1 1/2" LPS
1" DRAIN
1" CW
44"X12"X48"
PLENUM
8X24 AD
1" LPS
1" LPC
FOR CONTINUATION
SEE DWG. MH-101
CHILLED WATER COIL
1"Ø DRAIN FROM HUMIDIFIER
NEW LOUVER IN WINDOW OPENING BLANKED OFF
WITH INSULATED PANEL EXCEPT BOTTOM 34x24.
SEE ARCHITECTURAL DWG. FOR DETAILS
1" LPC
TO CP-1
1 1/2"
CHWS&R
BMS CONTROL PANEL
ELECTRICAL PANEL
NOTE:
1. CONTRACTOR SHALL RELOCATE ALL EXISTING PIPING AND CONDUITS AS
REQUIRED TO INSTALL NEW WORK.
2. LINE OF PHASE 1 TEMPORARY CONSTRUCTION BARRIER SEE DWG. AD101.
3. REFER TO DWG. AS101 AND SPECIFICATIONS FOR PHASING SEQUENCE OF
DEMOLITION AND NEW WORK.
DRIP
TRAP
1" MPC
TO FLASH
TANK
1/2" LPC
DRIP
TRAP
2" RELIEF VENT TO OUTSIDE
14x12
26x12
BM
S
1" PC
INTEGRAL FACE AND
BYPASS STEAM COIL
1" LPC
1" LPS
HX-1
ET-1
ABOVE
AS-1
1"
P-1 & P-2
1/2" LPC
1"
1 1/2"
HWS&R
1" MPC
FROM TRAP IN
CORRIDOR HPS
TO FLASH TANK
24x12 TO UNIT W/FC
10'-4"
2'
9'-0"
10'-2"
9'-8"
12" w x 48" H x 44" D PLENUM
20x10 DN TO UNIT W/FC
52" x 28" x 40" D PLENUM
4" HIGH CONCRETE CURB
PAINTED SAFETY YELLOW, SEE
ARCHITECTURAL FOR DETAILS
8"x24"ACCESS DOOR
MIXING PLENUM
RA DAMPER
OA DAMPER
FILTERS
INTERNAL FACE & BYPASS STEAM COIL
24x36 OAI LOUVER IN
THE WINDOW OPENING
CHILLED WATER COIL HUMIDIFIER SECTION
FAN
NEW LOUVER IN WINDOW OPENING BLANKED OFF
WITH INSULATED PANEL EXCEPT BOTTOM 24x36
ACCESS
SD
x
OA AIRFLOW SENSOR
ACCESS ACCESS
ACCESS
ACCESS
STEAM EXCHANGE
STEAM GENERATOR GS-1,
WALL MOUNTED 3'-0" AFF
CONDENSATE PUMP CP-1
ON 4" CONCRETE PAD
PAINTED YELLOW
CHILLED WATER COIL
AC-1
(2400)
BM
S
INTEGRAL FACE AND
BYPASS STEAM COIL
HUMIDIFIER SECTION
BMS CONTROL PANEL
ELECTRICAL PANEL
FAN
FILTERS
ACCESS AREAS
FLASH
TANK
8TH FLOOR NEW WORK
HVAC MER PART PLAN AND SECTION
1-MH500
J.O. N.R.
0 1' 2' 4'
SCALE: 1/2" = 1'-0"
0 1' 2' 4'
SCALE: 1/2" = 1'-0"
8TH FLOOR NEW WORK HVAC MER SECTION A-A
0 1' 2' 4'
SCALE: 1/2" = 1'-0"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
100% CDOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
MEP Consultant:
Project Director
05 Feb 2019Revisions: Date:
630A4-17-490
800 POLY PLACE, BROOKLYN, NY
RENOVATE ONCOLOGY
PHARMACY
MICHAEL AVRAMIDES ARCHITECT
319 E 50TH STREET, STUDIO E
NEW YORK, NY 10022
T:917.855.8111
ONSULTING NGINEERS
KALLEN & LEMELSON, LLP
P: (212) 643-9898 F: (212) 643-2332
IGHTH VENUE, TH LOOR, EW ORK, 520 E
A 17 F N Y
C E
NY 10018
8TH FLOOR NEW WORK HVAC MER PART PLAN
MER EQUIPMENT ACCESS PART PLAN
STEAM SUPPLY
SHUT-OFF VALVE
CONDENSATE RETURN
GATE VALVE (TYP.)
CHECK VALVE
STEAM TRAP TEST TEE
FLOAT & THERMOSTATIC TRAP
(TWICE COIL CAPACITY)
Y-STRAINER W/BLOW-OFF VALVE
CAP
6" MINIMUM
FULL SIZE COIL TAPPING
UNION OR FLANGE
(AS REQUIRED TYP.)
VACUUM BREAKER
STEAM COIL
CONTROL
VALVE
BYPASS
LINE
GLOBE VALVE
HVAC DETAILS 1
1-MH701
J.O. N.R.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
100% CDOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
MEP Consultant:
Project Director
05 Feb 2019Revisions: Date:
630A4-17-490
800 POLY PLACE, BROOKLYN, NY
RENOVATE ONCOLOGY
PHARMACY
MICHAEL AVRAMIDES ARCHITECT
319 E 50TH STREET, STUDIO E
NEW YORK, NY 10022
T:917.855.8111
ONSULTING NGINEERS
KALLEN & LEMELSON, LLP
P: (212) 643-9898 F: (212) 643-2332
IGHTH VENUE, TH LOOR, EW ORK, 520 E
A 17 F N Y
HVAC DETAILS 2
1-MH702
J.O. N.R.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
100% CDOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
MEP Consultant:
Project Director
05 Feb 2019Revisions: Date:
630A4-17-490
800 POLY PLACE, BROOKLYN, NY
RENOVATE ONCOLOGY
PHARMACY
MICHAEL AVRAMIDES ARCHITECT
319 E 50TH STREET, STUDIO E
NEW YORK, NY 10022
T:917.855.8111
ONSULTING NGINEERS
KALLEN & LEMELSON, LLP
P: (212) 643-9898 F: (212) 643-2332
IGHTH VENUE, TH LOOR, EW ORK, 520 E
A 17 F
N Y
HVAC DETAILS 3
1-MH703
J.O. N.R.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
100% CDOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
MEP Consultant:
Project Director
05 Feb 2019Revisions: Date:
630A4-17-490
800 POLY PLACE, BROOKLYN, NY
RENOVATE ONCOLOGY
PHARMACY
MICHAEL AVRAMIDES ARCHITECT
319 E 50TH STREET, STUDIO E
NEW YORK, NY 10022
T:917.855.8111
ONSULTING NGINEERS
KALLEN & LEMELSON, LLP
P: (212) 643-9898 F: (212) 643-2332
IGHTH VENUE, TH LOOR, EW ORK, 520 E
A 17 F N Y
SSO-1
WATSON MCDANIEL 1"
(20mm)
HD REGULATOR WITH
SOLENOID PILOT
MPS
45 PSIG
LPS
15 PSI
PS-2
CONTROL ASSOCIATES
ALARM 2-POINT ALARM
PANEL 120VAC
NTS
4) ALL VALVES, REGULATORS & CONTROLS SHALL BE PURCHASED FROM A SINGLE ENTITY
AND THE AUTHORIZED REPRESENTATIVE;
CONTROL ASSOCIATES, INC.
(201) 934-5001 20 COMMERCE DRIVE ALLENDALE, NJ 07401
GENERAL NOTES:
1) REGULATOR BODY MATERIAL TO BE CONSTRUCTED OF DUCTILE IRON.
2) REGULATOR PILOT TO HAVE INTEGRAL STRAINER WITH BLOW DOWN CAPABILITIES.
3) REGULATOR DIAPHRAGM TO BE CONSTRUCTED OF PHOSPHOR BRONZE MATERIAL.
SOV-1
1" (25mm)
PS-1
HIGH/LOW
SOV-3
1-1/2"
BPV-1
3/4"
STEAM PRV SCHEDULE
TAG
INLET - OUTLET
PRESSURE
(PSIG) (KPA)
FLOW RATE
(#/HR) KG/HR
SIZE
(INCHES) (MM)
DESCRIPTION
END
CONNECTIONS
SOV-1
45-45/0 (300)
3/4 (20)
POWELL FORGED STEEL
GATE VALVE
NPT
SSO-1
45-45/0 (300)
3/4 (20)
WATSON MCDANIEL HD
REGULATOR WITH PS
SOLENOID PILOT
NPT
SOV-2
45-45/0 (300)
3/4 (20)
POWELL FORGED STEEL
GATE VALVE
NPT
PRV-1
45-45/0 (300) 300 (136) 3/4 (20)
WATSON MCDANIEL HD
REGULATOR WITH PP
PRESSURE PILOT
NPT
SOV-3
15-15/0 (100)
1 (25)
POWELL FORGED STEEL
GATE VALVE NPT
BPV-1 MANUAL -
3/4 (20)
POWELL FORGED STEEL
GLOBE VALVE NPT
PS-1
2 STAGE PRESSURE
SWITCH WIRED TO ALARM
PANEL
PS-2
MANUAL RESET
PRESSURE SWITCH
OPERATES SSO
PRV-1
WATSON MCDANIEL 3/4" (20mm)
HD REGULATOR WITH
PRESSURE PILOT
1" (25mm) 1" (25mm)
1-1/2" (38mm)
3/4" (20mm)3/4" (20mm)
SOV-2
1" (25mm)
VALVE
STEAM
TRAP
UNION STRAINER
10'-0"
PRESSURE
REGULATING VALVE
BY-PASS VALVE
SAFETY SHUT-OFF
VALVE
D
D
19.540
12" FLANGE ADAPTER
FILTER
47.625" FILTER OR 23.8" FILTER
12" FLEXIBLE DUCT TO HARD DUCT
D
(20mm)
(38mm)
(300 KPA)
(100 KPA)
(305cm)
(496 mm)
(300 mm)
(300 mm)
(1220 mm) OR (605 mm)
HVAC DETAILS 4
1-MH704
J.O. N.R.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
100% CDOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Architectural Design Consultant:
Project Director
5 FEB 2019 MC TBRevisions: Date:
630A4-17-490
800 POLY PLACE, BROOKLYN, NY
RENOVATE ONCOLOGY
PHARMACY
THINKFORM DESIGN ARCHITECT LLC
38 EAST BROAD STREET
HOPEWELL, NJ 08525
T:855.821.0274 F:609.644.4397
MICHAEL AVRAMIDES ARCHITECT
319 E 50TH STREET, STUDIO E
NEW YORK, NY 10022
T:917.855.8111
TYPICAL TRANSVERSE CABLE BRACING
FOR DUCTWORK
THE VMC GROUP SPEC ISOLATOR TYPE C, D, E
THE VMC GROUP SPEC RESTRAINT TYPE V
DRAWING SGMEC-120
TYPICAL TRANSVERSE & LONGITUDINAL CABLE BRACING
FOR DUCTWORK
THE VMC GROUP SPEC ISOLATOR TYPE C, D, E
THE VMC GROUP SPEC RESTRAINT TYPE V
DRAWING SGMEC-122
TYPICAL TRANSVERSE SINGLE ARM BRACE
FOR CLEVIS -HUNG PIPING & CONDUIT
THE VMC GROUP SPEC RESTRAINT TYPE VI
DRAWING SGMEC-210
TYPICAL TRANSVERSE SINGLE ARM BRACE
FOR DUCTWORK
THE VMC GROUP SPEC RESTRAINT TYPE VI
DRAWING SGMEC-212
TYPICAL TRANSVERSE AND LONGITUDINAL CABLE BRACING
FOR INLINE FANS
THE VMC GROUP SPEC ISOLATOR TYPE C, D, E
THE VMC GROUP SPEC RESTRAINT TYPE V
DRAWING SGMEC-132
TYPICAL TRANSVERSE & LONGITUDINAL
SINGLE ARM BRACE FOR DUCTWORK
THE VMC GROUP SPEC RESTRAINT TYPE VI
DRAWING SGMEC-214
TYPICAL TRANSVERSE SINGLE ARM BRACE
FOR TRAPEZE-HUNG PIPING & CONDUIT
THE VMC GROUP SPEC RESTRAINT TYPE VI
DRAWING SGMEC-216
TYPICAL TRANSVERSE CABLE BRACING
FOR CLEVIS HUNG PIPING & CONDUIT
THE VMC GROUP SPEC RESTRAINT TYPE V
DRAWING SGMEC-110
TYPICAL CALCULATION SHEET HOUSEKEEPING PAD
REINFORCEMENT
SGMEC-800
TYPICAL ATTACHMENT OF RIGID SEISMIC BRACING TO
PIPE OR CLEVIS USING BEAM CLAMP
THE VMC GROUP SPEC RESTRAINT TYPE VI
DRAWING SGMEC-290
Floor Line
Pad Height
6"
Pad outline
Standard Floor
Reinforcing Rebar
2" min.
3"
"Z" bars tie to standard floor reinforcing rebar
3"
Pad Height
Embedment
Floor Line
Hilti Kwikbolt II concrete expansion anchor or equivalent
Length
22.5"
6"
6"
Width
15"
33.75"
#5 reinforcing rebar spaced at 12" o.c.e.w.*
Length = Per Project Req. Anchor size Embedment
Width = Per Project Req. 5/8" anchor 4"
Pad Height = Per Project Req. 3/4" anchor 4-3/4"
==> 3/4" dia. concrete expansion anchors or #6 rebar "Z" bars
==> 5/8" dia. concrete expansion anchors or #5 rebar "Z" bars
Notes:
1) All housekeeping pad reinforcing should conform to ACI Standards for minimum area and concrete coverage.
2) Minimum concrete strength of 3000 psi.
TYPICAL HOUSEKEEPING PAD TIE-DOWN REQUIREMENTS
6"
Pad outline
*O.C.E.W = ON CENTER EACH WAY
31 32
33 34 35 36 37
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
100% CDOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
MEP Consultant:
Project Director
05 Feb 2019Revisions: Date:
630A4-17-490
800 POLY PLACE, BROOKLYN, NY
RENOVATE ONCOLOGY
PHARMACY
MICHAEL AVRAMIDES ARCHITECT
319 E 50TH STREET, STUDIO E
NEW YORK, NY 10022
T:917.855.8111
ONSULTING NGINEERS
KALLEN & LEMELSON, LLP
P: (212) 643-9898 F: (212) 643-2332
IGHTH VENUE, TH LOOR, EW ORK, 520 E
A 17 F N Y
C E
NY 10018
HVAC DETAILS 5
1-MH705
J.O. N.R.
TYPICAL TRANSVERSE & LONGITUDINAL CABLE BRACING
FOR CLEVIS HUNG PIPING & CONDUIT
THE VMC GROUP SPEC RESTRAINT TYPE V
DRAWING SGMEC-112
TYPICAL TRANSVERSE CABLE BRACING FOR
TRAPEZE -HUNG PIPING & CONDUIT
THE VMC GROUP SPEC RESTRAINT TYPE V
DRAWING SGMEC-114
TYPICAL TRANSVERSE& LONGITUDINAL CABLE BRACING
FOR TRAPEZE HUNG PIPING & CONDUIT
THE VMC GROUP SPEC RESTRAINT TYPE V
DRAWING SGMEC-116
TYPICAL INSTALLATION OF FLOOR-MOUNTED
EQUIPMENT
THE VMC GROUP SPEC ISOLATOR TYPE B
THE VMC GROUP SPEC RESTRAINT TYPE I
DRAWING SGMEC-410
TYPICAL SEISMIC ATTACHMENT OF MECHANICAL EQUIPMENT
TO HOUSEKEEPING PAD OR STRUCTURAL DECK
THE VMC GROUP SPEC RESTRAINT TYPE IV
DRAWING SGMEC-910
TYPICAL ATTACHMENT OF RIGID SEISMIC BRACING TO
STRUCTURE USING BEAM CLAMP
THE VMC GROUP SPEC RESTRAINT TYPE VI
DRAWING SGMEC-292
SEISMIC ROD BRACING CLAMP
THE VMC GROUP SPEC RESTRAIN
TYPE V, VI
DRAWING SGMEC-190
TYPICAL SINGLE ARM BRACE ATTACHMENT
TO CONCRETE STRUCTURE
THE VMC GROUP SPEC RESTRAINT TYPE VI
DRAWING SGMEC-296
38 39 40 41
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
100% CDOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
MEP Consultant:
Project Director
05 Feb 2019Revisions: Date:
630A4-17-490
800 POLY PLACE, BROOKLYN, NY
RENOVATE ONCOLOGY
PHARMACY
MICHAEL AVRAMIDES ARCHITECT
319 E 50TH STREET, STUDIO E
NEW YORK, NY 10022
T:917.855.8111
ONSULTING NGINEERS
KALLEN & LEMELSON, LLP
P: (212) 643-9898 F: (212) 643-2332
IGHTH VENUE, TH LOOR, EW ORK, 520 E
A 17 F N Y
C E
NY 10018
HVAC DETAILS 6
1-MH706
OPTION 1
OPTION 2
OPTION 2
OPTION 1
OPTION 1
OPTION 2
TYPICAL SEISMIC CABLE RESTRAINT ATTACHMENT
OF TYPE SCR TO STRUCTURE
THE VMC GROUP SPEC RESTRAINT TYPE V
DRAWING SGMEC-194
TYPICAL SINGLE ARM BRACE
ATTACHMENT TO STRUCTURE
THE VMC GROUP SPEC RESTRAINT TYPE VI
DRAWING SGMEC-294
TYPICAL SEISMIC CABLE RESTRAINT ATTACHMENT
TO CONCRETE STRUCTURE
THE VMC GROUP SPEC RESTRAINT TYPE V
DRAWING SGMEC-192
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
100% CDOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
MEP Consultant:
Project Director
05 Feb 2019Revisions: Date:
630A4-17-490
800 POLY PLACE, BROOKLYN, NY
RENOVATE ONCOLOGY
PHARMACY
MICHAEL AVRAMIDES ARCHITECT
319 E 50TH STREET, STUDIO E
NEW YORK, NY 10022
T:917.855.8111
ONSULTING NGINEERS
KALLEN & LEMELSON, LLP
P: (212) 643-9898 F: (212) 643-2332
IGHTH VENUE, TH LOOR, EW ORK, 520 E
A 17 F N Y
C E
NY 10018
HVAC DETAILS 7
1-MH707
SYMBOLS AND ABBREVIATIONS
AI ANALOG INPUT
AO ANALOG OUTPUT
DI DIGITAL INPUT
DO DIGITAL OUTPUT
TEMPERATURE SENSORT
HUMIDITY SENSORH
DIFFERENTIAL PRESSURE SENSORDP
IFBD INTEGRAL FACE AND BYPASS DAMPER
MOTORISED VALVE
M
FREEZE STATFS
SD SMOKE DETECTOR
START / STOPS/S
PRESSURE SENSORP
SG CLEAN STEAM GENERATOR
CURRENT SENSORC/S
HIGH LIMIT HUMIDISTATHLH
RF-1 RETURN FAN
SF-1 SUPPLY FAM
LE-1 LAB EXHAUST FAN
DIFFERENTIAL PRESSURE SENSORDP
AIR FLOW SWITCHAFS
M
MOTORIZED DAMPER
HC-1 HEATING COIL
CC-1 COOLING COIL
PF-1 PRE - FILTER
AF-1 AFTER FILTER
S/S C/S
DIDO
LAB EXHAUST FAN
CHEMO EF-2
CONTROL DIAGRAM
CHEMO EF-2
S/S C/S
DIDO
AC-RF-1
T5 H5
AI AI
M RA
EA
M
RA
OA
M
HC-1PF-1
DP
AF-1
DP
MIFBD
LPS
M P
T2 FS
CC-1
M
CH
W R
CH
W
S
T T
AF
SG-1
M
S/S C/S
DO DI
SF-1
T4 HLH
SA
POWERED AND WIRED TO FA SYSTEM FOR AHU SHUTDOWN
SD
AO AO AO AI AI AO AOAI AI DI AI AIAO DI AO AI DI
CP-1
C/S
DI AI
LOW PRESSURE STEAM CONDENSATE PUMP CP-1
CONTROL DIAGRAM
TH DP FFU
VFD VARIABLE FREQUENCY DRIVE
SCR SILICON CONTROLLED RECTIFIER
P
CHEMO
ROOM
T
AI
SPACE TEMPERATURE SENSOR
(TYPICAL)
AF AIR FLOW SENSOR
CAV CONSTANT AIR VOLUME BOX
AF
T
AIAI HWR
CAV
CAV BOX DIAGRAM
(SUPPLY ONLY)
(SUPPLY ONLY)
LPS
HOT WATER HEATING COIL
(TYPICAL FOR SUPPLY)
T1
AI AI
T3
AI
M
AO
M
AOHWS
T
H
EXISTING OUTSIDE AIR SENSOR
V-1 V-2
V-3
V-4
T T
AC-1
Outside Air
O.A. Damper
Filter AF-1
Mixed Air T1
Return Air Fan RF-1
Heating Coil Steam Valve V1
Steam Pressure
Freezstat
Cooling Coil Chilled Water Valve V2
Chilled Water Temperature Supply Return
Cooling Coil Discharge Temperature T3
Steam Generator Contrl Valve V3
Discharge Air T4
Return Air T5, H5
CAV Boxes (12)
Cav Box Reheat Coil (Supply Only) (4)
Hot Water Supply & Return
Room Space Temperatures (4)
Room Humidity (3)
Filter PF-1
Return Air Damper
Relief Air Damper
Heating Coil Discharge Temperature T2
Fan Filter Units (5)
Differential Pressure Sensors (4)
NOTES:
PROVIDE HARD WIRED POINTS AS SCHEDULED AND SHOWN ON CONTROL DIAGRAMS.
REQUIRED POINTS ARE NOT LIMITED TO THOSE INCLUDED IN THE SUMMARY TABLE.
ADDITIONAL POINTS MAY BE INDICATED IN THE CONTROL DIAGRAM OR SEQUENCE OF OPERATION.
S/S C/S
DIDO
STANDBY
Lab Exhaust Fan & Standby (2)
Condensate Pump
Global Points
AIR HANDLING UNIT AC-1 CONTROL DIAGRAM
Supply duct RH High Limit
DI
AF
AI
COMBINED TEMPERATURE AND HUMIDITY SENSORTH
NOTES:
ALL CONTROL POINTS FOR AC-60, AC-1RF, AND EF-1 SHALL BE CONNECTED
TO FACILITY BMS.
DP
BACNET CONNECTION
TH DP TH
ANTE ROOM
(4)
THESE POINTS PROVIDED BY TERRA MODULAR CLEAN ROOM MANUFACTURER
T
OFFICE
AI
STORAGE
STERILE
COMPOUNDING
ROOM
HX-1
AI
T
T
AS
ET-1
S/S C/S
M
P
DOAO AI DI
LPS HWS
P-1
HWR
HOT WATER HEATER EXCHANGER AND PUMPS
AI AI
Heat Exchanger HX-1
Heat Exchanger Pump P-1 & P-2
P-2
S/S C/S
DO DI
DP
LPC
AI
SEQUENCE OF OPERATION
ALL AUTOMATIC TEMPERATURE CONTROLS SHALL BE PROVIDED THROUGH THE BMS. ALL SETPOINTS SHALL BE FULLY ADJUSTABLE THROUGH THE BMS.
START OPERATION
ON A COMMAND FROM THE BMS, THE OUTSIDE AIR DAMPER OF AC-1 SHALL OPEN TO THE MINIMUM POSITION, THE RETURN AIR DAMPER SHALL OPEN, THE RELIEF AIR DAMPER SHALL REMAIN CLOSED, AIR HANDLER FAN AC-1 SHALL START, AND THE RETURN AIR FAN AC-RF-1 SHALL START. THE OUTSIDE AIRFLOW ENTERING THE AIR HANDLER THROUGH THE OUTSIDE AIR DAMPER SHALL BE MEASURED. THE LAB EXHAUST FAN CHEMO EF-1 AND EF-2 SHALL RUN CONTINUOUSLY. IF THE FIRST LAB EXHAUST DOES NOT START OR STOPS OPERATINGTHE STANDBY LAB EXHAUST FAN SHALL START. THE MAIN AND STANDBY
LAB EXHAUST FAN SHALL ALTERNATE EVERY 168 HOURS (ADJUSTABLE) OF OPERATION.
HEATING OPERATION
WHEN THE OUTSIDE AIR TEMPERATURE IS LESS THAN 32 F (ADJUSTABLE), THE PREHEAT STEAM CONTROL VALVE SHOULD BE OPEN, AND THE
INTEGRAL FACE AND BYPASS DAMPER ON THE STEAM COIL SHALL MODULATE TO MAINTAIN THE DISCHARGE SETPOINT OF 52 F (ADJUSTABLE).
WHEN THE OUTSIDE AIR TEMPERATURE IS ABOVE 32 F (ADJUSTABLE), AND HEATING IS REQUIRED, THE FACE AND BYPASS DAMPER SHALL BE
OPEN TO THE PREHEAT COIL FACE, AND THE STEAM CONTROL VALVE SHALL MODULATE TO MAINTAIN THE DISCHARGE SETPOINT OF 52 F
(ADJUSTABLE). IF THE FREEZESTAT SENSOR TEMPERATURE IS BELOW 32 F (ADJUSTABLE), THE AIR HANDLER SHALL SHUT SHALL DOWN, THE
OUTSIDE AIR DAMPER SHALL CLOSE, AND THE RETURN FAN SHALL SHUT DOWN.
HUMIDIFIER OPERATION
THE HUMIDIFIER OPERATION SHALL BE ENABLED WHENEVER THE OUTSIDE AIR TEMPERATURE IS BELOW 60 F (ADJUSTABLE). THE HUMIDIFIER CLEAN STEAM GENERATOR STEAM CONTROL VALVE SHALL MODULATE STEAM FLOW TO MAINTAIN A MINIMUM RELATIVE HUMIDITY OF 30% (ADJUSTABLE) AND A MAXIMUM RELATIVE HUMIDITY OF 50 %( ADJUSTABLE) IN THE CHEMO BUFFER ROOM, THE STERILE COMPOUNDING ROOM, AND THE ANTE ROOM. IF THE HIGH LEVEL HUMIDITY SENSOR IN THE SUPPLY DUCT IS OVER 90% RELATIVE HUMIDITY, OR THERE IS NO AIRFLOW, THE STEAM GENERATOR CONTROL VALVE
SHALL SHUT DOWN.
COOLING OPERATION
WHEN THE OUTSIDE AIR TEMPERATURE IS GREATER THAN 52 F (ADJUSTABLE), AND CHILLED WATER IA AVAILABLE COOLING SHALL BE PROVIDED BY MODULATING THE COOLING COIL CHILLED WATER CONTROL VALVE TO MAINTAIN A DISCHARGE TEMPERATURE OF 52 F (ADJUSTABLE).
ECONOMIZER CYCLE
WHEN THE OUTSIDE AIR TEMPERATURE IS HIGHER THAN 32 F (ADJUSTABLE) BUT LOWER THAN 52 F (ADJUSTABLE), THE OUTSIDE AIR, RETURN AIR AND RELIEF DAMPERS SHALL MODULATE TO MAINTAIN A DISCHARGE AIR TEMPERATURE OF 52 F (ADJUSTABLE). WHEN THE OUTSIDE AIR TEMPERATURE IS BETWEEN 52 F (ADJUSTABLE) AND 70 F (ADJUSTABLE), THE OUTSIDE AIR DAMPER SHALL BE OPEN, THE RETURN AIR DAMPER SHALL BE CLOSED AND THE RELIEF AIR DAMPER OPEN. WHEN THE OUTSIDE AIR TEMPERATURE IS ABOVE 70 F (ADJUSTABLE), THE OUTSIDE AIR DAMPER SHALL BE CLOSED TO MINIMUM
POSITION.
CAV BOXES WITH REHEAT
THE CAV BOXES SHALL MODULATE TO MAINTAIN A FIXED AIR FLOW RATE. THE HOT WATER REHEAT VALVES SHALL MODULATE TO MAINTAIN THE ROOM TEMPERATURES OF 68 F (ADJUSTABLE) IN THE CHEMO BUFFER ROOM, THE STERILE COMPOUNDING ROOM, AND THE ANTE ROOM. THE HOT WATER REHEAT VALVES SHALL MODULATE TO MAINTAIN A TEMPERATURE OF BETWEEN 70 F (ADJUSTABLE) IN THE WINTER AND 75 F (ADJUSTABLE) IN THE SUMMER IN THE OFFICE. THE BAS SHALL MONITOR THE AIRFLOW OF ALL CAV BOXES AND THE SUPPLY AND RETURN WATER TEMPERATURES TO THE REHEAT COILS AND
ALARM WHEN AIRFLOWS OR WATER TEMPERATURES VARY SIGNIFICANTLY FROM SETPOINT.
FAN FILTER UNITS (FFUS), TEMPERATURE AND HUMIDITY SENSOR AND DIFFERENTIAL PRESSURE SENSORS
THE BAS SHALL MONITOR ALL FFU AIRFLOWS, ROOM TEMPERATURE AND RELATIVE HUMIDITIES, AND DIFFERENTIAL STATIC PRESSURE IN THE CHEMO ROOM, STERILE COMPOUNDING ROOM, AND THE ANTE ROOM AND ALARM WHEN AIRFLOW, TEMPERATURE, RELATIVE HUMIDITY AND STATIC PRESSURE VARY
SIGNIFICANTLY FROM SETPOINT.
SMOKE DETECTOR
THE SMOKE DETECTOR IN THE SUPPLY DUCT SHOULD BE WIRED TO THE FIRE ALARM SYSTEM. THE FIRE ALARM SYSTEM WILL SHUT DOWN THE AIR HANDLER
HOT WATER REHEAT WATER SYSTEM
WHEN THE HOT WATER REHEAT WATER SYSTEM IS ENABLED ,THE HOT WATER PUMP P-1 SHALL RUN CONTINUOUSLY.THE STEAM CONTROL VALVE FOR THE BRAZED PLATE HEAT EXCHANGER HX-1 SHALL MODULATE TO MAINTAIN A SUPPLY WATER TEMPERATURE OF 180 F(ADJUSTABLE). IF PUMP P-1 FAILS, THE STANDBY PUMP P-2 SHALL START AND RUN CONTINUOUSLY. THE MAIN PUMP AND THE STANDBY PUMP SHALL ALTERNATE EVERY 168 HOURS (ADJUSTABLE)
OF OPERATION.
S/S C/S
DIDO
LAB EXHAUST FAN
CHEMO EF-1
CONTROL DIAGRAM
CHEMO EF-1
S/S C/S
DIDO
STANDBY
HVAC CONTROL
DIAGRAM
1-MI800
J.O. N.R.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
100% CDOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
MEP Consultant:
Project Director
05 Feb 2019Revisions: Date:
630A4-17-490
800 POLY PLACE, BROOKLYN, NY
RENOVATE ONCOLOGY
PHARMACY
MICHAEL AVRAMIDES ARCHITECT
319 E 50TH STREET, STUDIO E
NEW YORK, NY 10022
T:917.855.8111
ONSULTING NGINEERS
KALLEN & LEMELSON, LLP
P: (212) 643-9898 F: (212) 643-2332
IGHTH VENUE, TH LOOR, EW ORK, 520 E
A 17 F N Y
| Sheets and Views |
| M001 |
| MD-101 |
| MH-101 |
| MH102 |
| MP-103 |
| MH401 |
| MH402 |
| MH500 |
| MH701 |
| MH702 |
| MH703 |
| MH704 |
| MH705 |
| MH706 |
| MH707 |
| MI800 |