This is a Sources Sought Notice issued by the Department of Veterans Affairs, Boston Healthcare System for market research purposes to identify potential sources for an automated medication dispensing cabinet (ADC) system. The VA White River Junction VAMC requires a specialized ADC system with software designed specifically for operating room and anesthesia care environments. The system must store medications and supplies while supporting anesthesia-specific clinical workflows and meeting rigorous security, chain-of-custody, and regulatory compliance requirements for controlled substance management.

The salient characteristics required include OR-purpose-built workflows, anesthesia-exclusive virtual inventory management, personalized user-specific medication kits, two-step provider handoff capabilities with chain-of-custody transfer, multispectral biometric (fingerprint) authentication with DEA EPCS certification, demand-activated drawer mechanisms for high-risk medications, tamper-evident rear panel alarms, dual asymmetric keyed rear panel locks, 35-minute minimum battery backup, native integration with safe medication labeling systems, and WPA3 Enterprise wireless security. Respondents must indicate whether the product is domestically or non-domestically manufactured and provide compliance status with the Trade Agreements Act and Buy American Act. The NAICS code is 339112 (Surgical and Medical Instrument Manufacturing) with a 1,000-employee size standard. Interested parties should submit responses by August 26, 2026 at 3:00 pm EST to Contract Specialist Kim McCarthy at kim.mccarthy@va.gov. This notice explicitly states it does not obligate the Government to award a contract and is for informational and planning purposes only.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sources Sought Notice Sources Sought Notice

SUBJECT*
Automated Medication Management System

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
02301
SOLICITATION NUMBER*
36C24126Q0732
RESPONSE DATE/TIME/ZONE
08-25-2026 15:00 EASTERN TIME, NEW YORK, USA
ARCHIVE
45 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N

SET-ASIDE

PRODUCT SERVICE CODE*
6515
NAICS CODE*
339112
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

VA Boston Healthcare System Contracting Officer (90C) 940 Belmont Street Brockton MA 02301

POINT OF CONTACT*

Contract Specialist Kim McCarthy kim.mccarthy@va.gov

PLACE OF PERFORMANCE

ADDRESS
VAMC White River Junction

215 North Main Street

White River Junction VT

POSTAL CODE
05009-0001

COUNTRY

ADDITIONAL INFORMATION

AGENCY’S URL

URL DESCRIPTION

AGENCY CONTACT’S EMAIL ADDRESS
kim.mccarthy@va.gov

EMAIL DESCRIPTION

DESCRIPTION

SOURCES SOUGHT NOTICE

This is a Sources Sought Notice for market research purposes only. This is NOT a solicitation or request for proposal/quote, and does not obligate the Government to award a contract.

1. Purpose The Department of Veterans Affairs (VA) is conducting market research to identify potential sources capable of providing the item(s) described below that are domestically and non-domestically manufactured. This notice is issued solely for informational and planning purposes.

2. Background The White River Junction, VT VAMC has a requirement for the provision, installation, and implantation of an automated medication dispensing cabinet (ADC) system, and necessary software, specifically designed for use in the operating room (OR) and anesthesia care environment. The system must store both medications and related supplies, support anesthesia-specific clinical workflows, and meet stringent security, chain-of-custody, and regulatory compliance requirements applicable to controlled substance management in a perioperative setting.

3. NAICS Code / Size Standard NAICS Code: 339112 – Surgical and Medical Instrument Manufacturing Size Standard: 1,000 employees

4. Salient Characteristics The item sought must meet or exceed the following salient characteristics. Respondents proposing an equal product must demonstrate that their item meets each characteristic listed below.

· OR-purpose-built workflows not available in general-purpose ADCs

· Anesthesia-exclusive virtual inventory management allowing providers to issue, transfer, return, or waste medication from a personally managed drug tray without prior patient selection

· Personalized, user-specific medication kits accessible only to the assigned provider, at any compatible station facility-wide

· Two-step provider handoff (chain-of-custody transfer) enabling mid-case transfer of accountability between anesthesia providers while maintaining patient selection and drawer access continuity

· Multispectral biometric (fingerprint) authentication capturing both surface and subsurface characteristics, suitable for OR clinical conditions, and DEA EPCS-certified

· Electronic biometric consent capture and automatic template purge upon user decline

· Demand-activated ("pop-open") drawer mechanism for high-risk medications such as Propofol, without a handle or front-panel position sensor

· Tamper-evident rear panel alarm with electronic logging of unauthorized access attempts

· Dual asymmetric keyed rear panel locks with keys controlled exclusively by the customer

· Minimum 35-minute internal battery backup with automatic data preservation during power loss

· Native integration with a safe medication labeling system supporting scan-to-decrement and common sign-on/sign-off for TJC-compliant syringe labeling

· WPA3 Enterprise wireless security with 802.1X authentication support These requirements are necessary to ensure medication safety, chain-of-custody integrity, regulatory compliance (DEA, TJC), and interoperability with the VA's existing perioperative medication management workflows and infrastructure.

5. Domestic / Non-Domestic Sourcing Respondents must indicate whether the proposed item is manufactured domestically or non-domestically, and specify:

· Country of origin

· Compliance status with the Trade Agreements Act (TAA), 19 U.S.C. § 2501 et seq., and/or the Buy American Act (BAA), as applicable to this procurement

· Whether the item is listed on the applicable GSA Federal Supply Schedule as TAA-compliant, if known

6. Information Requested from Respondents Interested parties are requested to submit the following information:

1. Company Information: Name, address, point of contact, phone number, and email address

2. Business Size/Status: Indicate business size (large/small) and any applicable socioeconomic status (e.g., SDVOSB, VOSB, HUBZone, WOSB, 8(a)), with proof of certification/verification (e.g., SAM.gov, VetCert)

3. Capability Statement: A statement addressing your firm's ability to provide an item meeting all salient characteristics listed in Section 4, including identification of any characteristics your proposed item does not meet

4. Product Information: Manufacturer name, model/part number, and product literature or specification sheets sufficient to demonstrate compliance with Section 4

5. Sourcing: Domestic or non-domestic origin and TAA/BAA compliance status, per Section 5

6. Contract Vehicle: Whether the item is available on an existing Government Wide Acquisition Contract vehicle, and the associated contract number

7. Disclaimer This Sources Sought Notice is for informational and market research purposes only and does not constitute a solicitation. The Government will not pay for any information submitted in response to this notice, nor will it compensate any respondent for costs incurred in developing a response. Responses will not be returned. The Government reserves the right to consider a Small Business Set-Aside, Service-Disabled Veteran-Owned Small Business Set-Aside, or Full and Open Competition based on the responses received to this notice. No solicitation currently exists; therefore, do not request a copy of a solicitation.

8. Response Instructions Interested parties should submit responses via email to Kim McCarthy at kim.mccarthy@va.gov no later than August 26, 2026 at 3:00 pm EST.

Subject Line: Sources Sought Response – 36C24126Q0732– Anesthesia Automated Dispensing Cabinet

9. Point of Contact Contract Specialist: Kim McCarthy, kim.mccarthy@va.gov

*= Required Field