Att D salient characteristics - Chemo Gloves.pdf
PDF 139 KB Posted
- Solicitation number
- 36C24121Q0225
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Salient Characteristics –Chemotherapy Rated Gloves
• Must be Chemotherapy rated and labeled. Either of the below standards is acceptable.
o Should have ASTM D6978-05(2019) ‘Standard Practice for Assessment of Resistance of
Medical Gloves to Permeation by Chemotherapy Drugs’ 12” cuff (300mm) extended cuff gloves preferred for chemo administration
• Meet general standards of medical grade gloves
• Quality medical grade gloves – generally are between 3-4 mils thick; thicker gloves rip less and are more protective against needlestick injuries.
o Thicker gloves are better
• No talc or powder inside or out
• Medical grade gloves should meet ASTM D6319-19 standards o Have an ASTM AQL (acceptable quality level) overall rating of less than 2.5 AQL (1.0 is preferred)
Test D5151 – Water test = 2.5 AQL or lower (1.0 preferred) Test D6124 – Residual powder test = max of 2mg per glove for powder free gloves Test D1671 – Blood borne Pathogen test = must Pass Nitrile gloves:
• Test D6319 – Medical grade Nitrile = AQL of 2.5, tensile strength of at least 18MPa, and minimum of 500% elongation
Vinyl gloves:
• Test D5250 – Medical grade Vinyl = AQL of 2.5, tensile strength of at least 11MPa, and minimum of 300% elongation o Reference for standards: http://www.psggear.com/index.php/quality-standards
Comparible products
VersaShield Extended Cuff Powder-Free Nitrile Exam Gloves | Medline Industries, Inc.
VersaShield Extended Cuff Powder-Free Nitrile Exam Gloves Manufacturer: Medline
• VersaShield gloves offer dependable strength you can count on and have a long 12" cuff that helps provide an extra barrier for your wrists and arms; textured fingertips provide enhanced grip
• Barrier tested against fentanyl exposure up to 167 minutes to help protect you when treating overdose patients (permeation testing per ASTM D6978-05)
• Chemical tested to ASTM F739-12*
• Meets both ASTM D6978-05 and USP 800 Personal Protection Equipment requirement for use of chemotherapy gloves when handling hazardous drugs**
• Meet standards of the National Fire Protection Association (NFPA)***
* Tested chemicals available upon request.
** When used in accordance to the guidelines set forth in the USP 800 chapter. Tested http://www.psggear.com/index.php/quality-standards https://www.medline.com/product/VersaShield-Extended-Cuff-Powder-Free-Nitrile-Exam-Gloves/SensiCare/Z05-PF149181 chemotherapy drugs available upon request. Caution: Testing showed a minimum breakthrough time of 30.3 minutes with Carmustine, 91.0 minutes with Thiotepa.
*** Data on file.
VersaShield Extended Cuff Powder-Free Nitrile Exam Gloves
File details come from the government source that posted it. Updated .