36C10X26Q0167.docx
DOCX document 25 KB Posted
- Solicitation number
- 36C10X26Q0167
About this file
This is a Combined Synopsis/Solicitation Notice and Request for Quote (RFQ) issued by the Department of Veterans Affairs Strategic Acquisition Center in Frederick, Maryland for the procurement of Physiologic Monitor Modules: Pulse Oximetry equipment. The VA seeks to establish a single-award Requirements contract for Masimo O3 brand name or equal noninvasive patient monitoring systems that measure cerebral oxygen saturation using near-infrared spectroscopy (NIRS) technology. The requirement covers 18 Contract Line-Item Numbers (CLINs) including the Root Monitor, Regional Oximeter Module, sensors, clamps, cable tethers, roll stands, software applications, interface modules, barcode readers, and various service options such as installation, wireless site surveys, and concierge service plans. The contract will serve VA Medical Centers nationwide and is classified under NAICS code 339112 (Surgical and Medical Instrument Manufacturing) with a size standard of 800 employees.
The solicitation is unrestricted and full and open competition. Quotes are due by June 10, 2026 at 10:00 AM Eastern Time via email to Contract Specialist Jalima Jones and Contracting Officer Sara Vickroy, with questions due by May 29, 2026. The contract term consists of one 12-month base year with four 12-month option years, with delivery on a FOB destination basis and firm-fixed price orders. All vendors must be registered in the System for Award Management (SAM) prior to submission. Offerors proposing equal products must provide detailed descriptions of salient characteristics, brand names, make/model numbers, and descriptive literature demonstrating equivalence to the Masimo O3 specification. Five salient characteristics are specified: continuous non-invasive cerebral oxygen saturation values, bilateral sensor placement capability, configurable desaturation alarms, HL7 data connectivity for hospital information system integration, and FDA clearance for cerebral oximetry in anesthesiology and perioperative care.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Combined Synopsis/Solicitation Notice Combined Synopsis/Solicitation Notice
| SUBJECT* |
| Physiologic Monitor Modules: Pulse Oximetry |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 21703 |
| SOLICITATION NUMBER* |
| 36C10X26Q0167 |
| RESPONSE DATE/TIME/ZONE |
| 06-10-2026 10:00am EASTERN TIME, NEW YORK, USA |
| ARCHIVE |
| 99 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| 6515 |
| NAICS CODE* |
| 339112 |
| CONTRACTING OFFICE ADDRESS |
| Strategic Acquisition Center - Frederick |
Department of Veterans Affairs
5202 Presidents Court, Suite 103 Frederick MD 21703
POINT OF CONTACT*
Contract Specialist Jalima J. Jones Jalima.Jones@va.gov
PLACE OF PERFORMANCE
| ADDRESS |
| Nationwide |
POSTAL CODE
COUNTRY
ADDITIONAL INFORMATION
| AGENCY’S URL |
| https://www.va.gov/opal/sac/index.asp |
| URL DESCRIPTION |
| VA | OALC | OPAL | SAC |
| AGENCY CONTACT’S EMAIL ADDRESS |
| Jalima.Jones@va.gov |
| EMAIL DESCRIPTION |
| Jalima.Jones@va.gov |
DESCRIPTION
Solicitation Number:
36C10X26Q0167 Notice Type:
Combined Synopsis/Solicitation
This is a combined synopsis/solicitation for brand name, or equal commercial items prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, “Streamlined Procedures for Evaluation and Solicitation for Commercial Items,” as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation will not be issued.
Solicitation number 36C10X26Q0167 is issued for this combined synopsis/solicitation; this solicitation is being issued as a Request for Quote (RFQ). This combined synopsis/solicitation incorporates provisions and clauses in effect through Federal Acquisition Circular (FAC) 2026-01, dated 13 March 2026.
Requirement Description:
VA has a requirement to purchase Physiologic Monitor Modules: Pulse Oximetry to deliver patient care to its VA Medical Centers around the country. The Physiologic Monitor Modules: Pulse Oximetry is a noninvasive patient monitoring system that continuously measures regional hemoglobin oxygen saturation specific tissues, such as the brain during anesthesia. It utilizes near-infrared spectroscopy (NIRS) technology through sensors placed on the skin, typically the forehead, to determine the balance between regional oxygen delivery and demand.
A single award Requirements contract will be awarded as a Brand Name or Equal in accordance with all terms, conditions, provisions, specifications, and schedule of this solicitation herein. Quotes shall contain the terms for cost/price and technical capabilities of the brand name or equal equipment. The Government reserves the right to award without discussions.
The associated North American Industrial Classification System (NAICS) code for this procurement is 339112 – Surgical and Medical Instrument Manufacturing, Product Service Code: 6515 Medical and Surgical Instruments, Equipment, and Supplies. The associated size standard is 800 employees. This procurement action is Unrestricted Full and Open.
This acquisition is for a single award Requirements contract in accordance with FAR Part 16.5 for Masimo O3® brand name or equal to The Physiologic Monitor Modules: Pulse Oximetry as identified in ATTACHMENT A – PRICE COST SCHEDULE - NX EQ PHYSIOLOGIC MONITOR MODULES: PULSE OXIMETRY. All interested companies shall provide a QUOTE for all Contract Line-Item Numbers (CLINs) listed in ATTACHMENT A – PRICE COST SCHEDULE - NX EQ PHYSIOLOGIC MONITOR MODULES: PULSE OXIMETRY.
The ordering period is for one 12-month base year with four 12-month option years. Delivery is a FOB destination. Firm-Fixed Price Orders will be placed against this contract in writing and will provide the delivery locations, delivery dates and exact quantities.
The FAR provision at 52.212-1, Instructions to Offerors – Commercial Products and Commercial Services, applies to this acquisition including attached addenda to the provision.
The FAR provision at 52.212-2, Evaluation -- Commercial Products and Commercial Services Items, and the specific evaluation criteria as attached addenda also applies to this acquisition.
Clause 52.212-4, Terms and Conditions -- Commercial Products and Commercial Services, applies to this acquisition and a statement regarding any addenda to the clause. Addendum is attached.
All interested quoters must be registered in the System for Award Management (SAM) prior to submitting a quote. You may access SAM at https://sam.gov/SAM/.
Questions regarding this combined synopsis/solicitation are due via email by 10:00 AM Eastern Standard Time (EST) on May 29, 2026, to Contract Specialist, Jalima Jones at Jalima.Jones@va.gov and Contracting Officer, Sara Vickroy at Sara.Vickroy@va.gov No calls will be accepted. Quotes are due via email by 10:00 AM EST on June 10, 2026, to Contract Specialist, Jalima Jones at Jalima.Jones@va.gov and Contracting Officer, Sara Vickroy at Sara.Vickroy@va.gov
1. SCOPE OF WORK
The Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified Physiologic Monitor Modules: Pulse Oximetry product line as a candidate for a VA-wide (otherwise referred to as “national”) single Requirements contract award.
The Physiologic Monitor Modules: Pulse Oximetry is a noninvasive patient monitoring system that continuously measures regional hemoglobin oxygen saturation specific tissues, such as the brain during anesthesia. It utilizes near-infrared spectroscopy (NIRS) technology through sensors placed on the skin, typically the forehead, to determine the balance between regional oxygen delivery and demand.
The Contractor must demonstrate the ability to meet all requirements for the solicitation. The objective is to provide Physiologic Monitor Modules: Pulse Oximetry to be used by VHA clinicians throughout the United States and its territories. The period of performance is for one 12-month base period with four 12-month option periods.
2. REQUIREMENT
This requirement will be, “Brand Name or Equal” which requires the quoter indicate that each product being offered as an “equal” product to Masimo O3® or equal Physiologic Monitor Modules: Pulse Oximetry. For each equal product, the quoter must include a description reflecting the salient characteristics (SCs) and level of quality that will satisfy the salient physical, functional, or performance characteristics of the equal product(s) specified in the solicitation. The quoter must also clearly identify the item by brand name (if any) and make/model number. Finally, the offeror must include descriptive literature, such as illustrations, drawings, or a clear reference to previously furnished descriptive data or information available to the Contracting Officer (CO) and clearly describe any modifications it plans to make to a product to make it conform to the solicitation requirements.
The following line-items comprise the Physiologic Monitor Modules: Pulse Oximetry product line:
Contract Line-Item Number
Brand
Part Number
Description
| 0001 |
| Masimo O3® |
| 9515 |
| Root Monitor |
| 0002 |
| Masimo O3® |
| 9637 |
| O3 Regional Oximeter Module |
| 0003 |
| Masimo O3® |
| 3756 |
| O3 Sensor, Adult (20/box) |
| 0004 |
| Masimo O3® |
| 4575 |
| O3 Module Clamp |
| 0005 |
| Curbell Medical |
| 15785 |
| Curbell Cable Tethers, 6" (12/box) |
| 0006 |
| Masimo O3® |
| 300238 |
| Root Roll Stand |
| 0007 |
| Masimo O3® |
| 28814 |
| DLMS Virtual Server |
| 0008 |
| Masimo O3® |
| 27161 |
| BAG ASSY, IRIS GTWY VIRTL APPL, V2.0.0.1 |
| 0009 |
| Masimo O3® |
| 27274 |
| BAG ASY, IRIS GTWY VRT APPL, TST SVR, V2001 |
| 0010 |
| Masimo O3® |
| 101138 |
| USB 1D/2D BARCODE READER |
| 0011 |
| Masimo O3® |
| 3963 |
| HL7, ADT, INTERFACE |
| 0012 |
| Masimo O3® |
| 4526 |
| HL7, NOTIFCATIONS |
| 0013 |
| Masimo O3® |
| 3964 |
| HL7, RESULTS OUT, INTERFACE |
| 0014 |
| Masimo O3® |
| 2456 |
| INSTALLATION SERVICES, SAFETY NET |
| 0015 |
| Masimo O3® |
| 9712-LIC |
| IRIS DCX PER BED LICENSE |
| 0016 |
| Masimo O3® |
| 102-3Y |
| IRIS SERVICE, 3 Yr |
| 0017 |
| Masimo O3® |
| 2457 |
| WIRELESS SITE SURVEY |
| 0018 |
| Masimo O3® |
| 114-3Y |
| CONCIERGE+ SERVICE PLAN FOR DEVICES, 3YR |
The Department of Veterans Affairs (VA) is seeking vendors who can provide Masimo O3® brand name or equal to Physiologic Monitor Modules: Pulse Oximetry as listed above which meet all the following salient characteristics.
Vendors may quote any product solution or configuration so long as they meet the salient characteristics. Products quoted in the technical volume must be captured on the Vendor’s pricing volume (Attachment A, Price Cost Schedule) of the solicitation. Vendors may quote any additional ancillary products which they deem to be essential to the functionality of the proposed solution; these items must be captured in the Vendor’s pricing volume with a quantity of zero.
| SC # |
| Salient Characteristics |
| Method of Evaluation |
| Applicable CLINs |
| Page # Where SC is Found in Technical Literature |
| SC 1 |
| Must provide continuous non-invasive Cerebral oxygen saturation (rSO₂) values as a stand-alone system. |
| Literature Review |
| 0001-0003 |
| SC2 |
| Must allow for placement of bilateral sensors to assess cerebral oxygenation. |
| Literature Review |
| 0001-0003 |
| SC3 |
| Must provide configurable alarms for cerebral desaturation thresholds. |
| Literature Review |
| 0001-0002 |
| SC4 |
| Data Output/Connectivity – Must support export of oximetry data for integration with hospital information systems (e.g., HL7, CIS/ARK, etc.). |
| Literature Review |
| 0001, 0007-0015 |
| SC5 |
| Regulatory Approval – Must have FDA clearance for cerebral oximetry applications in anesthesiology and perioperative care. |
| Literature Review |
| 0001-0003 |
The following attachments are incorporated by reference. All criteria outlined in the attachments are applicable to this combined synopsis/solicitation.
See attached document: ATTACHMENT A - PRICE COST SCHEDULE - NX EQ PHYSIOLOGIC MONITOR MODULES PULSE OXIMETRY.
See attached document: ATTACHMENT B - CONTRACT ADMINISTRATION - NX EQ PHYSIOLOGIC MONITOR MODULES PULSE OXIMETRY.
See attached document: ATTACHMENT C - CONTRACT CLAUSES - NX EQ PHYSIOLOGIC MONITOR MODULES PULSE OXIMETRY.
See attached document: ATTACHMENT D - SOLICITATION PROVISIONS - NX EQ PHYSIOLOGIC MONITOR MODULES PULSE OXIMETRY.
See attached document: ATTACHMENT E - REPORTING TOOL - NX EQ PHYSIOLOGIC MONITOR MODULES PULSE OXIMETRY.
See attached document: ATTACHMENT F - PAST PERFORMANCE REFERENCE - NX EQ PHYSIOLOGIC MONITOR MODULES PULSE OXIMETRY.
See attached document: ATTACHMENT G - PAST PERFORMANCE QUESTIONNAIRE - NX EQ PHYSIOLOGY MONITOR MODULES PULSE OXIMETRY.
| *= Required Field |
| Combined Synopsis/Solicitation Notice |
Combined Synopsis/Solicitation Notice
File details come from the government source that posted it. Updated .