36C10G26Q0026.docx

DOCX document 27 KB Posted

Attached to
6515--NX EQ Neuromuscular Blockade Monitoring (VA-26-00024566)
Solicitation number
36C10G26Q0026
Issued by

About this file

This Sources Sought Notice is issued by the Department of Veterans Affairs (VA) Strategic Acquisition Center seeking qualified vendors to provide Neuromuscular Blockade Monitoring equipment, specifically the Blink Device TwitchView2 or equivalent, for VA medical centers nationwide. The anticipated contract is a Requirements Contract with Firm-Fixed Price (FFP) orders, covering one 12-month base period with four 12-month option periods, focusing on medical devices used to measure muscle relaxation during surgical procedures.

The solicitation (36C10G26Q0026) targets vendors in NAICS code 339112 with a 1000-employee size standard, seeking comprehensive neuromuscular monitoring systems that meet six specific salient characteristics. Key requirements include EMG-based quantitative monitoring, rechargeable battery, single-use patient sensors, integration with Anesthesia Record Keeping systems, noise cancellation capabilities, and simplified user workflow. Vendors must be registered in SAM.gov, with responses due by 12-31-2025 at 16:30 PM Eastern Time, and are required to provide detailed company information, product specifications, technical documentation, and service plan details.

View the file

Other files

File Type Posted
36C10G26Q0026 0002.docx DOCX document
36C10G26Q0026 0001 - Neuromuscular Blockade Monitoring.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sources Sought Notice

SUBJECT*
NX EQ Neuromuscular Blockade Monitoring (VA-26-00024566)

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
22408-2697
SOLICITATION NUMBER*
36C10G26Q0026
RESPONSE DATE/TIME/ZONE
12-31-2025 16:30 PM EASTERN TIME, NEW YORK, USA
ARCHIVE
99 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N

SET-ASIDE

PRODUCT SERVICE CODE*
6515
NAICS CODE*
339112
CONTRACTING OFFICE ADDRESS
U.S. Department of Veterans Affairs

OPAL | Strategic Acquisition Center

10300 Spotsylvania Ave | STE 400 Fredericksburg VA 22408-2697

POINT OF CONTACT*

Contract Specialist Michael Andrews michael.andrews6@va.gov

(678) 428-5319

PLACE OF PERFORMANCE

ADDRESS
Nationwide

POSTAL CODE

COUNTRY

ADDITIONAL INFORMATION

AGENCY’S URL
https://www.va.gov/opal/sac/index.asp
URL DESCRIPTION
VA | OALC | OPAL | SAC
AGENCY CONTACT’S EMAIL ADDRESS
michael.andrews6@va.gov
EMAIL DESCRIPTION
michael.andrews6@va.gov

DESCRIPTION

*= Required Field
Sources Sought Notice

Sources Sought Notice

1.0 DESCRIPTION

The Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Neuromuscular Blockade Monitoring product line as a candidate for a VA-wide (otherwise referred to as “national”) single Requirements contract award.

The Department of Veterans Affairs’ (DVA) Office of Procurement, Acquisition and Logistics (OPAL) Strategic Acquisition Center (SAC) on behalf of VHA is issuing this Sources Sought Notice in accordance with the FAR 10.002(b)(2) to determine the availability and technical capabilities of qualified sources.

The SAC in conjunction with VHA is seeking a qualified source to provide Blink Device TwitchView2® brand name or equal Neuromuscular Blockade Monitoring on an agency wide basis. VA intends to award a Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contract to a supplier of this equipment. Vendors will be required to deliver the Neuromuscular Blockade Monitoring to VA medical centers and facilities throughout the United States and its territories.

The anticipated period of performance is for one 12-month base period with four 12-month option periods from the date of award. However, the Government's decision as to whether to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need. The Contractor must demonstrate the ability to meet all requirements for the solicitation.

The associated North American Industrial Classification System (NAICS) code for this procurement is 339112- Neuromuscular Blockade Monitoring, Product Service Code: 6515 – Medical and Surgical Instruments, Equipment, and Supplies and the associated size standard is 1000 employees. The FAR Provision found at 52.204-7(b)(1) requires that “All interested Offerors must be registered in SAM.gov prior to submitting an offer or quotation.” You may access the website at SAM.gov | Home. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the SBA database at: https://veterans.certify.sba.gov/#search at the time of quote submission.

This notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought Notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes.

2.0 SCOPE

Neuromuscular Blockade Monitoring refers to the process of measuring and assessing the degree of muscle relaxation induced by neuromuscular blocking agents (NMBAs), which are drugs used to induce temporary paralysis, typically during surgical procedures or in intensive care settings. These agents inhibit the transmission of nerve impulses at the neuromuscular junction, leading to muscle relaxation. Monitoring is critical to ensure the appropriate depth of muscle relaxation is achieved and maintained, which helps in optimizing patient safety and the effectiveness of the procedure. Effective neuromuscular blockade monitoring helps in adjusting the dosage of NMBAs, avoiding both underdosing (which may lead to inadequate muscle relaxation) and overdosing (which can result in prolonged paralysis and complications), and ensuring timely and appropriate recovery of muscle function post-procedure.

The following Contract Line-Items Number (CLIN) are being considered:

Contract Line Items
Manufacturer
Part Number
Description
0001
Blink
P-TVSYS-02
TwitchView2 System/ Pole Mount
0002
Blink
B-TVSYS-02
TwitchView2 System/ Ball Mount
0003
Blink
TVARM-DSL
TwitchArm Double Short Long
0004
Blink
TVESA03
3-Year TwitchView2 Extended Service Agreement
0005
Blink
TVESA05
5-Year TwitchView2 Extended Service Agreement
0006
Blink
TVAEA025
TwitchView2 Adult Electrode Array (Case of 25)
0007
Blink
TVCAB-02
TwitchView2 Patient Cable 12 FT
0008
Blink
TVCAB-03
TwitchView2 Patient Cable 14 FT
0009
Blink
TVINSERVICE
Clinical In-service Training 1-day
0010
Blink
TVST-01
TwitchView2 System Tester
0011
Blink
TVCPS-02
TwitchView2 Capsule/Draeger Cable

The Department of Veterans Affairs (VA) is seeking vendors who can provide TwitchView2® brand name or equal Neuromuscular Blockade Monitoring as listed above or equal commodities which meets all the following Salient Characteristics (SC):

SC #

SALIENT CHARACTERISTICS

METHOD OF EVALUATION

SC 1
The system shall provide electromyography (EMG)-based quantitative neuromuscular monitoring of neuromuscular transmission, measuring both Train-of-Four (TOF) count/ratio and Post-Tetanic Count (PTC) when applicable.
Literature Review
SC 2
Rechargeable battery with at least 6 hours of use fully charged
Literature Review
SC 3
Must have single-use patient sensors. The device itself must have written cleaning instructions
Literature Review
SC 4
Must have capability and required cable to integrate with Anesthesia Record Keeping (ARK) Systems.
Literature Review
SC 5
Must have noise cancellation that produces clear, diagnostic signal throughout the case, able to filter out interference from surrounding equipment (such as RF interference from electrosurgical unit
Literature Review
SC 6
User Workflow / Ease-of-Use: The system shall support a simplified workflow: the electrode is placed, “Play/Start” pressed, and monitoring begins; minimal set-up time to be achieved (e.g., within ~ 20 seconds).
Literature Review

The Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer (OEM) and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the salient characteristics. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.

Responses to this Sources Sought Notice shall include the following:

1. Company information

a. Full name and address of company

b. SAM Unique Entity Identifier (UEI)

c. Business size

d. If authorized distributor, provide evidence that your firm is an authorized distributor for the OEM of the products proposed.

e. Point of contact name and email address

2. Information on your product/solution

a. Does your product have FDA clearance for clinical use in the United States?

b. Please provide a yes or no, with a brief point-by-point explanation of how your product can or cannot meet each draft salient characteristic, in a chart/table format.

c. Please provide OEM technical literature that clearly shows how your product meets each salient characteristic. Please ensure the OEM technical literature is properly mapped with respective page numbers so it is easy to reference and connect to the draft salient characteristics.

d. What are the unique or highlighted features of your neuromuscular blockade monitor — specifically, the key physical, functional, or performance characteristics?

e. What are your product solutions or configurations for this anticipated Neuromuscular Blockade Monitoring procurement? Please provide model name(s) and part number(s).

f. What are your product’s sensor placement options, and how does it work for amputee patients where standard wrist placement sites may not be an option?

g. Please describe your product’s wireless and wired setup. For example, are the sensors wireless or wired? How does your product integrate or communicate with the VA’s ARK information system?

h. Can sensors from other brands/manufacturers be used with your product? Or can sensors only from your own brand/OEM be utilized with your product?

i. Are your sensors reusable or single-use only? If disposable, what are the protocols for handling, storage, and disposal?

j. What is your company’s ability to provide uninterrupted supply of products on a national scale?

k. What is the country-of-origin designation for your product/solution?

3. Draft salient characteristics/requirements

a. Considering our draft salient characteristics, are there any additional salient characteristics you recommend incorporating, and why?

4. Does vendor offer an annual service plan?

a. If Yes:

i. What does the plan cover?

ii. Does plan cover software updates only?

iii. Does the plan cover parts repair and/or replacement?

iv. Does the plan cover both software and parts?

v. Provide documentation that shows information and details of your service plans.

vi. Is the service provided by the OEM or a subcontractor?

*= Required Field
Sources Sought Notice

Page 1 of

Page 1 of

Sources Sought Notice

File details come from the government source that posted it. Updated .