The file's text, extracted by GovTribe without its formatting.
Sources Sought Notice Sources Sought Notice
| SUBJECT* |
| NX EQ Capsule Endoscopy (VA-26-00006488) |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 22408-2697 |
| SOLICITATION NUMBER* |
| 36C10G25Q0114 |
| RESPONSE DATE/TIME/ZONE |
| 08-22-2025 15:30 EASTERN TIME, NEW YORK, USA |
| ARCHIVE |
| 90 DAYS AFTER THE RESPONSE DATE |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| 6515 |
| CONTRACTING OFFICE ADDRESS |
| U.S. Department of Veterans Affairs |
OPAL | Strategic Acquisition Center
10300 Spotsylvania Ave | STE 400 Fredericksburg VA 22408-2697
POINT OF CONTACT*
Contracting Specialist Hosea Berkley hosea.berkley@va.gov 202-276-2992
PLACE OF PERFORMANCE
POSTAL CODE
COUNTRY
ADDITIONAL INFORMATION
| AGENCY’S URL |
| https://www.va.gov/opal/sac/index.asp |
| URL DESCRIPTION |
| VA | OALC | OPAL | SAC |
| AGENCY CONTACT’S EMAIL ADDRESS |
| hosea.berkley@va.gov |
| EMAIL DESCRIPTION |
| hosea.berkley@va.gov |
DESCRIPTION
1. DESCRIPTION
The Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Capsule Endoscopy System product line as a candidate for a VA-wide (otherwise referred to as “national”) single Requirements contract award.
The North American Industry Classification System (NAICS) code for Capsule Endoscopy System is 334510 – Endoscopic equipment, electromedical (e.g., bronchoscopes, colonoscopes, cystoscopes), manufacturing: 6515 – Medical and Surgical Instruments, Equipment, and Supplies.
2. SCOPE
This requirement will be IAW FAR clause 6.303, Brand Name which requires the quoter indicate that the product being offered is a Capsule Endoscopy System from Medtronic.
Capsule Endoscopy systems are designed to examine various points along the intestinal tract using images captured with a tiny ingestible video camera. These systems typically consist of three components: a disposable ingestible camera pill/capsule that is swallowed by the patient and that transmits video images as it passes through the gastrointestinal tract, a recorder used by the patient (e.g., worn on a belt around the waist) that receives the signals transmitted by the camera, and a workstation appropriate for processing and displaying the images from the recorder. Ingestible camera endoscopic video systems are used to detect abnormalities (e.g., angioectasia, ulcers, tumors) especially in areas of the small intestine that are difficult or impossible to reach using endoscopes.
| Contract Line Items |
| Manufacturer |
| Part Number |
| Description |
| 0001 |
| Medtronic |
| FGS-0504 |
| USBC 2PK |
| 0002 |
| Medtronic |
| FGS-0688 |
| PillCam® GENIUS SB 1 PK US |
| 0003 |
| Medtronic |
| FGS-0802 |
| SOFTWARE PillCam® 9.7 US |
| 0004 |
| Medtronic |
| FGS-0806 |
| Genius Sync Agent (GSA) OFFLINE PillCam® US |
| 0005 |
| Medtronic |
| FGS-0808 |
| BARCODE SCANNER |
| 0006 |
| Medtronic |
| FGS-0668 |
| PillCam® Patency Capsule 5-Pack |
| 0007 |
| Medtronic |
| FGS-0347 |
| PillCam® RECORDER DR3 X1 |
| 0008 |
| Medtronic |
| FGS-0355 |
| PillCam® RECORDER CRADLE DR3X1 |
| 0009 |
| Medtronic |
| FGS-0362 |
| PillCam® RECORD ACCESSORIESDR3 |
| 0010 |
| Medtronic |
| FGS-0498 |
| PillCam® SB 3-EX CAPSULE 5-PACK |
| 0011 |
| Medtronic |
| FGS-0499 |
| PillCam® SB 3-EX CAPSULE 10-PK |
| 0012 |
| Medtronic |
| FGS-0590 |
| PillCam® SENSOR BELT MS SB |
| 0013 |
| Medtronic |
| FGS-0591 |
| PillCam® SENSOR ARRAY MS |
| 0014 |
| Medtronic |
| FGS-0453 |
| PillCam® SENSOR SLEEVES 10-PACK |
The Department of Veterans Affairs (VA) is seeking vendors who can provide Medtronic Capsule Endoscopy System as listed below which meet all the following salient characteristics:
| SC # |
| SALIENT CHARACTERISTICS |
| Applicable CLIN |
| METHOD OF EVALUATION |
| SC – Literature Map |
| SC 1 |
| Allow for direct visualization of small bowel via the paired recorder |
| 0010, 0011 |
| Literature Review |
| Medtronic |
Page #39, 57
| SC 2 |
| Adaptive frame technology allows the capsule to capture images faster if the capsule is moving faster and slower if the capsule is moving slower and produces quality images |
| 0002, 0010, 0011 |
| Literature Review |
| Medtronic |
Page #40
| SC 3 |
| Software for enhanced reading capabilities and reduced reading time |
| 0003 |
| Literature Review |
| Medtronic |
Page #67
| SC4 |
| Optimized optics that deliver clear images and provide greater diagnostic ability |
| 0002, 0010, 0011 |
| Literature Review |
| Medtronic |
Page #67 - 70
| SC 5 |
| Recorder which actively communicates with the capsule and indicates when paired with capsule |
| 0002 |
| Literature Review |
| Medtronic |
Page #9
| SC 6 |
| Pillcam does not need to be retrieved to read data. |
| 0002, 0010, 0011 |
| Literature Review |
| Medtronic |
Page #14, 40
| SC 7 |
| System must have FDA 510 K Approval |
| All |
| Literature Review |
| Medtronic |
Page #56 - 66
| SC 8 |
| The Recorder system must have the ability to take video and still images. |
| 0010, 0011 |
| Literature Review |
| Medtronic |
Page #57
| SC 9 |
| Patency capsule that can be used to verify an unobstructed small bowel prior to capsule endoscopy procedure |
| 0002, 0010, 0011 |
| Literature Review |
| Medtronic |
Page #41
| SC 10 |
| Capable of remote ingestion |
| 0002, 0010, 0011 |
| Literature Review |
| Medtronic |
Page #40
| SC 11 |
| System does not require capital equipment |
| 0002 |
| Literature Review |
| Medtronic |
Page #40
| CLINs |
| MANUFACTURERS |
| PART NUMBERS |
| DESCRIPTION |
| BASE YEAR |
| OPTION YEAR ONE |
| OPTION YEAR TWO |
| OPTION YEAR THREE |
| OPTION YEAR FOUR |
Responses to this Sources Sought Notice shall include the following:
1) Full name and address of company
2) DUNS number/ CAGE Code/ SAM UIE
3) Business Size
4) Manufacturer or Distributor
a. If distributor provide full name, business size and address of manufacturer.
5) Country of Origin designation for all products.
6) Ability to provide uninterrupted supply of products on a national scale.
7) Technical Literature that clearly shows product(s) meet the identified salient characteristics (if submitting an “or-equal” item).
8) Any additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.
9) All small business, VOSB, SDVOSB distributors shall provide a valid letter of authorization from the manufacturer of the product/brand that you intend to offer. The letter shall be printed on the manufacturers letter head and be no older than 6 months old. The letter shall also clearly state how long your agreement is place with the manufacturer, e.g., 6 month, 4 years, expires 4 years from XXX, end of 2025, etc. The letter shall also be signed by a legally, authorized representative of the manufacturer.
Authorized Distributor Letter Certified by OEM with a current date.
| *= Required Field |
| Sources Sought Notice |
Sources Sought Notice