36C10G25Q0023.docx
DOCX document 42 KB Posted
- Attached to
- 6515--NX EQ Disinfectors: Liquid Germicide: Flexible Scope Automated Endoscope Reprocessor (AER)
- Solicitation number
- 36C10G25Q0023
About this file
This document is a Sources Sought Notice issued by the Department of Veterans Affairs (VA) Office of Procurement, Acquisition and Logistics (OPAL) Strategic Acquisition Center (SAC) on behalf of the Veterans Health Administration (VHA). The VA is seeking qualified vendors to provide Steris brand name or equal Disinfectors: Liquid Germicide: Flexible Scope Automated Endoscope Reprocessors (AERs) on an enterprise-wide basis. The anticipated contract will be a 12-month base period with four 12-month option periods. The NAICS code is 339113 Surgical Appliance and Supplies Manufacturing with a size standard of 800 employees. Vendors must be registered in SAM and certified with the appropriate NAICS code. SDVOSB/VOSB offerors must be verified in the SBA database.
The VA is seeking AERs that meet specified salient characteristics related to safety, design, performance, and quality/construction. Responses must include technical literature demonstrating the offered products meet the requirements, as well as company/vendor information and the ability to provide a national supply. The VA may consider additional beneficial product solutions or configurations as part of the responses.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sources Sought Notice
| SUBJECT* |
| NX EQ Disinfectors: Liquid Germicide: Flexible Scope Automated Endoscope Reprocessor (AER) |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 22408-2697 |
| SOLICITATION NUMBER* |
| 36C10G25Q0023 |
| RESPONSE DATE/TIME/ZONE |
| 12-06-2024 16:30 CENTRAL TIME, CHICAGO, USA |
| ARCHIVE |
| 60 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| 6515 |
| NAICS CODE* |
| 339113 |
| CONTRACTING OFFICE ADDRESS |
| U.S. Department of Veterans Affairs |
OPAL | Strategic Acquisition Center
10300 Spotsylvania Ave | STE 400 Fredericksburg VA 22408-2697
POINT OF CONTACT*
Contract Specialist Courtney Chattman Courtney.Chattman@va.gov
PLACE OF PERFORMANCE
| ADDRESS |
| Enterprise-wide |
POSTAL CODE
| COUNTRY |
| USA |
ADDITIONAL INFORMATION
| AGENCY’S URL |
| https://www.va.gov/opal/sac/index.asp |
| URL DESCRIPTION |
| To learn more about SAC and its mission, please click here |
AGENCY CONTACT’S EMAIL ADDRESS
EMAIL DESCRIPTION
DESCRIPTION
| *= Required Field |
| Sources Sought Notice |
Sources Sought Notice
1.0 DESCRIPTION
The Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Disinfectors: Liquid Germicide: Flexible Scope Automated Endoscope Reprocessors (AER) product line as a candidate for an Enterprise-wide (otherwise referred to as “national”) single Requirements contract award.
The Department of Veterans Affairs’ (VA) Office of Procurement, Acquisition and Logistics (OPAL) Strategic Acquisition Center (SAC) on behalf of VHA is issuing this Sources Sought in accordance with the FAR 10.002(b)(2) to determine the availability and technical capabilities of qualified sources.
The SAC in conjunction with VHA is seeking a qualified source to provide Steris® brand name or equal Disinfectors: Liquid Germicide: Flexible Scope AERs on an agency wide basis. VA intends to award a Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contract to a supplier of this equipment. Vendors will be required to deliver Disinfectors: Liquid Germicide: Flexible Scope AERs to VA medical centers and facilities throughout the United States.
The anticipated period of performance is for one 12-month base period with four 12-month option periods from the date of award. However, the Government's decision as to whether or not to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need.
The associated North American Industrial Classification System (NAICS) code for this procurement is 339113 Surgical Appliance and Supplies Manufacturing and the associated size standard is 800 employees. The FAR Provision found at 52.204-7(b)(1) requires that “All interested Offerors must be registered in SAM prior to submitting an offer or proposal.” You may access the SAM website at Home | SAM.gov. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the Small Business Administration (SBA) database at Veteran Small Business Certification (VetCert) database at: Veteran Small Business Certification (sba.gov) at the time of proposal submission.
This notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes.
2.0 SCOPE
Disinfectors: Liquid Germicide: Flexible Scope AERs are designed to standardize and automate the preparation of a manually precleaned endoscope so that it is safe for immediate reuse. These units typically use a liquid chemical germicidal agent for reprocessing. Automatic reprocessors can reduce the likelihood that a crucial reprocessing step will be skipped, help ensure that reprocessing is performed consistently using a recommended protocol and reduce personnel exposure to the irritating effects of liquid disinfectants/sterilant. Most reprocessors provide documentation of the disinfection/sterilization cycle, either in the system's memory or as a hard-copy printout.
The following Contract Line Items are being considered:
| Contract Line Item# |
| Brand |
| Part Number |
| Description |
| Base Year |
| Option Year I |
| Option Year II |
| Option Year III |
| Option Year IV |
| 0001 |
| Steris |
| ADV1007 |
| ADV SU RAP PA 110V W/AIR - AER Plymouth - Advantage Plus |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0002 |
| Steris |
| ADV1008 |
| ADV SU RAP PA 110V NO AIR - AER Plymouth - Advantage Plus |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0003 |
| Steris |
| ADVPT3007 |
| ADV+ PT 120V 30C W/AIR - AER Plymouth - Advantage Pass Thru |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0004 |
| Steris |
| ADVPT3008 |
| ADV+ PT 120V 30C NO AIR - AER Plymouth - Advantage Pass Thru |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0005 |
| Steris |
| 67199157 |
| BARCODE, ADV 100-199 |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0006 |
| Steris |
| 67199158 |
| BARCODE, ADV 200-299 |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0007 |
| Steris |
| 67199541 |
| BARCODE, ADV 300-399 |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0008 |
| Steris |
| 67199660 |
| BARCODE, ADV 400-499 |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0009 |
| Steris |
| ADV1063 |
| ADV, PRINTER SYSTEM |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0010 |
| Steris |
| 40100104 |
| PAPER, ADV PRINTER, 6PK |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0011 |
| Steris |
| 72233310 |
| WALL MOUNT BRACKET |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0012 |
| Steris |
| 78400915 |
| ASSY, HOOKUP STORAGE RACK |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0013 |
| Steris |
| 78400931 |
| ASSY, HOOKUP RACK, SHORT |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0014 |
| Steris |
| 78400924 |
| KIT, INTERCEPT UPTAKE 1G |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0015 |
| Steris |
| 78400974 |
| SPILL KIT RAP PA |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0016 |
| Steris |
| ADV1062 |
| ADV, ACTIVE VAPOR MGT |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0017 |
| Steris |
| CAS1000 |
| MODEL CAS-1000 ASSY, CASSETTE, TRANSPORT |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0018 |
| Steris |
| CB120002 |
| BAG, SMALL ACCESSORY 2/PK |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0019 |
| Steris |
| 100555 |
| MODEL 100555 UCR ADAPTER [1 EA] |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0020 |
| Steris |
| CLM110HU0108 |
| MODEL CLM-110-HU0108 HOOKUP, ADPTR AIR/WTR |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0021 |
| Steris |
| 28001 |
| MODEL 2-8-001 HU ZERO CHANNEL NO LT |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0022 |
| Steris |
| 28010 |
| MODEL 2-8-010 ASSY, HOOK-UP, OLYMPUS |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0023 |
| Steris |
| 28030 |
| MODEL 2-8-030 ASSY, HOOKUP, PENTAX-0K |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0024 |
| Steris |
| 28030HAN |
| MODEL 2-8-030HAN ASSY, HOOKUP, PENTAX-OK |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0025 |
| Steris |
| 28040 |
| MODEL 2-8-040 ASSY, HKUP STORZ 0K |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0026 |
| Steris |
| 28040HAN |
| MODEL 2-8-040HAN ASSY, HKUP STORZ 0K |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0027 |
| Steris |
| 28112 |
| MODEL 2-8-112 ASSY, HOOKUP OLMPUS 1K |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0028 |
| Steris |
| 28112HAN |
| MODEL 2-8-112HAN ASSY, HOOK-UP OLYMPUS 1K |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0029 |
| Steris |
| 28210 |
| MODEL 2-8-210 ASSY, HOOK-UP OLYMPUS 2K |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0030 |
| Steris |
| 28218 |
| MODEL 2-8-218 ASSY HOOKUP OLY 2K |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0031 |
| Steris |
| 28245HAN |
| MODEL 2-8-245HAN ASSY, HOOKUP, STORZ-2K |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0032 |
| Steris |
| 28335HAN |
| MODEL 2-8-335HAN ASSY, HOOKUP, OLYMPUS |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0033 |
| Steris |
| 28437HAN |
| MODEL 2-8-437HAN ASSY, HOOK-UP, PENTAX |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0034 |
| Steris |
| 28511 |
| MODEL 2-8-511 ASSY, HOOK-UP, OLY |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0035 |
| Steris |
| 28511HAN |
| MODEL 2-8-511HAN ASSY, HOOK-UP, OLY |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0036 |
| Steris |
| 28537HAN |
| MODEL 2-8-537HAN ASSY HKUP, PTX90 4K+JET |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0037 |
| Steris |
| 28611 |
| MODEL 2-8-611 ASSY, HOOK-UP, OLY |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0038 |
| Steris |
| 28611HAN |
| MODEL 2-8-611HAN ASSY, HOOK-UP, OLY |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0039 |
| Steris |
| 28617HAN |
| MODEL 2-8-617HAN ASSY, HKUP, OLY 2 BIOPSY |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0040 |
| Steris |
| 28619 |
| MODEL 2-8-619 ASSY HU 140 W/MH-974 |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0041 |
| Steris |
| 28711 |
| MODEL 2-8-711 ASSY, HOOKUP, OLYMPUS 5K |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0042 |
| Steris |
| 28711HAN |
| MODEL 2-8-711HAN ASSY, HOOKUP, OLYMPUS-5K |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0043 |
| Steris |
| 28718HAN |
| MODEL 2-8-718HAN ASSY, HOOK-UP, OLY 160/180 |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0044 |
| Steris |
| 28753 |
| MODEL 2-8-753 ASSEMBLY, HOOKUP, OLY-4K |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0045 |
| Steris |
| 28811 |
| MODEL 2-8-811 ASSY HKUP OLY-ECHO+LIFT |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0046 |
| Steris |
| 28901 |
| MODEL 2-8-901 KIT TEE/TOE/RUS HU ADV+ |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0047 |
| Steris |
| 58010 |
| MODEL 5-8-010 ASSY, HOOKUP DBL LT |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0048 |
| Steris |
| 58030HAN |
| MODEL 5-8-030HAN ASSY, HOOKUP |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0049 |
| Steris |
| 58040HAN |
| MODEL 5-8-040HAN ASSY HOOKUP STORZ OK DBL |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0050 |
| Steris |
| 58050HAN |
| MODEL 5-8-050HAN ASSY, HOOKUP, DILATOR |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0051 |
| Steris |
| 58112 |
| MODEL 5-8-112 ASSY, HOOKUP 2-SCOPE 1-K |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0052 |
| Steris |
| INS1004 |
| INSTALL, ADVANTAGE PLUS BUSINESS DAY |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0053 |
| Steris |
| INS1005 |
| INSTALL, ADVANTAGE PLUS NON-BUSINESS DAY |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0054 |
| Steris |
| INS1015 |
| INSTALL, ADV-PASS THRU BUSINESS DAY |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0055 |
| Steris |
| INS1016 |
| INSTALL, ADV-PASS THRU NON-BUSINESS DAY |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0056 |
| Steris |
| SE2000121 |
| DEINSTALL ADVANTAGE PLUS |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0057 |
| Steris |
| SE2000221 |
| DEINSTALL ADVANTAGE PASS THRU |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0058 |
| Steris |
| SE2000900071 |
| DISPOSAL OF AER |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0059 |
| Steris |
| SE20001696 |
| ADVANTAGE TRAINING - 1 PRODUCT (PER STUDENT) |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 0060 |
| Steris |
| SE20002696 |
| ADV PASS-THRU - 1 PRODUCT (PER STUDENT) |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
The VA is seeking vendors who can provide Steris® Disinfectors: Liquid Germicide: Flexible Scope AERs or equal as listed above which meet all the following salient characteristics (SC):
CLIN’s 0001-0004 apply to the following SC’s:
| SC # |
| SALIENT CHARACTERISTICS |
| METHOD OF EVALUATION |
| SC 1 |
| The unit should be a floor configuration that must be capable of efficiently cleaning and high-level disinfection (HLD) of all major brand endoscopes. |
| Literature Review |
| SC 2 |
| The unit must have visual and/or audible alarms to alert the user if there is a problem with the cycle or when the reprocessor requires maintenance (i.e. filter changes, etc.) |
| Literature Review |
| SC3 |
| The unit must have automated leak detection capabilities. |
| Literature Review |
| SC 4 |
| The unit must have the ability to electronically document, at a minimum: cycle parameters, times, and dates. |
| Literature Review |
Sub-factors
· Safety Safety features and functions of the offered equipment will be evaluated. Areas may include but are not limited to the following:
· Type of germicide used i.e. single or multi-use;
· Cross contamination reduction;
· Hands-free operation;
· Chemical storage;
· Blockage detection;
· Maintain air pressure during reprocessing to allow for cleaning of damaged endoscope;
· Final rinse water.
· Design Design features and functions of the offered equipment will be evaluated. Areas may include but are not limited to the following:
· Compatibility with major brand scopes, probes, and dilators;
· Compatibility with other sterile processing equipment;
· Automated cleaning/disinfection;
· Reprocessing temperatures;
· Cycles;
· Hands free operation;
· Visual display;
· Barcode scanner;
· Control panel;
· Scope hookup;
· Chemical storage;
· Solutions software.
· Performance Equipment will be evaluated for its ability to perform its intended function. Areas may include but are not limited to:
· Number of scopes processed per cycle;
· Ability to integrate with an instrument tracking system (i.e. CensiTrac or equivalent);
· Processing temperature;
· Cycle time, minutes;
· Self-decontamination;
· No-touch workflow;
· Pressure monitoring;
· Channel monitoring;
· Blockage detection;
· Leak detection;
· Final rinse.
· Quality/Construction Aspects of the construction and quality of material of the equipment will be evaluated and may include but not limited to:
· Life Span/Warranty
· Training
· Applicable accessories
For each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the SCs specified above.
The Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the SCs. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.
Responses to this Sources Sought Notice shall include the following:
1) Full name and address of company;
2) Unique Entity Identifier (UEI) number;
3) Business Size;
4) Manufacturer or Distributor;
a. If distributor provide full name, business size and address of manufacturer.
5) Country of Origin designation for all products;
6) Ability to provide uninterrupted supply of products on a national scale;
7) Technical Literature that clearly shows product(s) meet the identified SCs (if submitting an “or-equal” item);
8) Any additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.
Although not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.
| *= Required Field |
| Sources Sought Notice |
Page 1 of
Sources Sought Notice
File details come from the government source that posted it. Updated .