36C10G18R0151-0001001.xlsx

XLSX spreadsheet 18 KB Posted

Attached to
NX EQ Stretchers; Stryker Brand Name or Equal
Solicitation number
36C10G18R0151
Issued by

About this file

36C10G18R0151 0001 Revised Attachment B Minimum Salient Characteristics_Product Description.xlsx

View the file

Other files

File Type Posted
36C10G18R0151-0001000.docx DOCX document
36C10G18R0151-0001002.docx DOCX document
36C10G18R0151-006.docx DOCX document
36C10G18R0151-002.xlsx XLSX spreadsheet
36C10G18R0151-005.xls XLS spreadsheet
36C10G18R0151-001.xlsx XLSX spreadsheet
36C10G18R0151-004.docx DOCX document
36C10G18R0151-003.docx DOCX document
36C10G18R0151-000.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1 This requirement will be IAW FAR clause 52.211-6, “Brand Name or Equal” which requires that the offeror indicate each product that is being offered as an “equal” product. The Brand Name or Equal Provision applies only to CLINs 0001-0005 and their corresponding Option Year CLINs only. For each equal product, the offeror must include a description reflecting the characteristics and level of quality that will satisfy the salient physical, functional, or performance characteristics of the equal product(s) specified in the solicitation. The offeror also must clearly identify the item by brand name (if any) and make/model number. Finally, the offeror must include descriptive literature, such as illustrations, drawings, or a clear reference to previously furnished descriptive data or information available to the contracting officer, and clearly describe any modifications it plans to make to a product to make it conform to the solicitation requirements.

The power-drive stretchers will be used to reduce forces on staff and avoid resulting injuries during transfer and handling of patients of sizes up to 700 pounds.

Type 1: Power Drive Stretcher – Transport is expected to be used for patients of sizes up to 700 pounds who are being transported through facilities but for whom neither long stays nor weighing nor repositioning on the stretcher is expected. Areas that may use this type of stretcher include Escort, although long stays may lead toward more complex stretchers. Position adjustments including back raising and knee gatch are necessary for patient comfort, but high frequency of repositioning patients on these stretchers is not expected.

Type 2: Power Drive Stretcher - Multiple-Hour (such as ED or Same Day Surgery) is expected to be used for patients of sizes up to 700 pounds who are being transported through facilities and for whom long stays, repositioning and/or weighing are required. Features including powered positioning, patient controls, and scales, help to prevent wounds, minimize extra transfers, save time, and prevent injuries related to raising the head of the bed. Fall protection features and the ability to transport equipment that hangs off horizontal bars would also be of value on these stretchers. Areas that may use this type of stretcher include Emergency, Same Day Surgery, GI lab, Spinal Cord Injury, Dialysis, and others.

Contract Line Item Number (CLIN) 0001: Stryker Transport Stretchers / Part Number 1105000030 / Prime 5th Wheel, 30IN (FIFTH WHEEL--Helps Steer the Stretcher Straight)

Specification NumberMinimum Technical Specifications (SPEC)Capable of Meeting This SPEC (Y/N)Alternate/Equal Brand Part NumberLocation in Literature Which Indicates SC is MetVendor Comments
SC 1Must have width of at least 30 inches and length of at least 75.25”
SC 2Must accommodate minimum of 700 pounds weight capacity
SC 3Must have lift assist back rest that uses patient’s weight to help raise the head of the bed and drops hips to reduce need for boosting
SC 4Must have a minimum of 25 degrees of knee gatch to prevent slipping down, with a manual assisted control
SC 5Must have a minimum of 12° Trendelenburg/Reverse Trendelenburg position available
SC 6Must have single point activation four wheel brake system with controls at head and foot ends
SC 7Must have a minimum 2-year warranty including parts, labor and travel
SC 8Must have recovery chair position
SC 9Must have a oxygen holder mounted on litter
SC 10Must have steering handles at head end
SC 11Must have hydraulic foot control pedals on both sides with uni-lower pedal
SC 12Must be Power washable
SC 13Must have 23”-34” height range
SC 14Must have large 8” casters with covers
SC 15Must have a base with storage tray
SC 16Must have extended side rails with a minimum of 14 inches height
SC 17Must have Side rails that fold underneath the frame
SC 19Must have color options for easy identification
SC 20Must have a minimum of 1 permanent collapsible IV pole
Contract Line Item Number (CLIN) 0002: Stryker Transport Stretchers / Part Number 1115000030 / Prime Big Wheel, 30IN

(BIG WHEEL--Reduces Start-up Pushing Force by 50%)

Specification NumberMinimum Technical Specifications (SPEC)Capable of Meeting This SPEC (Y/N)Alternate/Equal Brand Part NumberLocation in Literature Which Indicates SC is MetVendor Comments
SC 1Must have width of at least 30 inches and length of at least 75.25”
SC 2Must accommodate minimum of 700 pounds weight capacity
SC 3Must have lift assist back rest that uses patient’s weight to help raise the head of the bed and drops hips to reduce need for boosting
SC 4Must have a minimum of 25 degrees of knee gatch to prevent slipping down, with a manual assisted control
SC 5Must have a minimum of 12° Trendelenburg/Reverse Trendelenburg position available
SC 6Must have single point activation four wheel brake system with controls at head and foot ends
SC 7Must have a minimum 2-year warranty including parts, labor and travel
SC 8Must have recovery chair position
SC 9Has oxygen holder mounted on litter
SC 10Must have Pop-Up steering handles at head end
SC 11Must have a hydraulic foot control pedals on both sides with uni-lower pedal
SC 12Must be Power washable
SC 13Must have a 23”-34” height range
SC 14Must have large 8” casters with covers
SC 15Must have a base with storage tray
SC 16Must have extended side rails with a minimum of 14 inches height
SC 17Must have Side rails that fold underneath the frame
SC 19Must have color options for easy identification
SC 20Must have a minimum of 1 permanent collapsible IV pole
Contract Line Item Number (CLIN) 0003: Stryker Transport Stretchers / Part Number 1125000030 / Prime Zoom 30"

(Zoom Drive Almost Eliminates the Need for Physical Force to Push the Sttretcher)

Specification NumberMinimum Technical Specifications (SPEC)Capable of Meeting This SPEC (Y/N)Alternate/Equal Brand Part NumberLocation in Literature Which Indicates SC is MetVendor Comments
SC 1Must have width of at least 30 inches and length of at least 75.25”
SC 2Must accommodate minimum of 700 pounds weight capacity
SC 3Must have a lift assist back rest that uses patient’s weight to help raise the head of the bed and drops hips even when electric controls are not usable
SC 4Must have a minimum of 25 degrees of knee gatch to prevent slipping down, with a manual assisted control
SC 5Must have a minimum of 12° Trendelenburg/Reverse Trendelenburg position available
SC 6Must have extended side rails with a minimum of 14 inches height
SC 7Must have Side rails that fold underneath the frame
SC 8Must have a power assisted drive system that assists pushing, pulling, and steering
SC 9Must have a switch to allow manual drive in case of power system failure
SC 10Must have a single point activation four wheel brake system with controls at head and foot ends
SC 11Must have a minimum 2-year warranty including parts, labor and travel
SC 12Must be FDA Approved
SC 13Must have recovery chair position
SC 14Must have an automatic stop
SC 15Must have a oxygen holder mounted on litter
SC 16Must have pop-up steering handles at head end
SC 18Must have a base with storage tray
SC 19Must have a 23”-34” height range
SC 20Must have 8” casters
SC 22Must have hydraulic foot control pedals on both sides with uni-lower pedal
SC 23Must have color options for easy identification
Contract Line Item Number (CLIN) 0004: Stryker Transport Stretchers / Part Number 1125000000E / Prime Zoom, Electric

(Zoom Drive Almost Eliminates the Need for Physical Force to Push the Sttretcher)

Specification NumberMinimum Technical Specifications (SPEC)Capable of Meeting This SPEC (Y/N)Alternate/Equal Brand Part NumberLocation in Literature Which Indicates SC is MetVendor Comments
SC 1Must have width of at least 30 inches and length of at least 75.25”
SC 2Must accommodate minimum of 700 pounds weight capacity
SC 3Must have electrical controls for up/down, head, and knees
SC 4Must have foot end patient lockout controls
SC 5Must have lift assist back rest that uses patient’s weight to help raise the head of the bed and drops hips even when electric controls are not usable
SC 6Must have a minimum of 25 degrees of knee gatch to prevent slipping down, with a manual assisted control
SC 7Must have a minimum of 12° Trendelenburg/Reverse Trendelenburg position available
SC 8Must have extended side rails with a minimum of 14 inches height
SC 9Must have Side rails that fold underneath the frame
SC 10Must have a power assisted drive system that assists pushing, pulling, and steering
SC 11Must have a switch to allow manual drive in case of power system failure
SC 12Must have a single point activation four wheel brake system with controls at head and foot ends
SC 13Must have a minimum 2-year warranty including parts, labor and travel
SC 14Must be FDA Approved
SC 15Must have recovery chair position
SC 16Must have a automatic stop
SC 17Must have a oxygen holder mounted on litter
SC 18Must have steering handles at head end
SC 19Must have a base with storage tray
SC 20Must have a 23”-34” height range
SC 21Must have 8” casters
SC 22Must have a scale
SC 24Must have a hydraulic foot control pedals on both sides with uni-lower pedal
SC 25Must have color options for easy identification
Contract Line Item Number (CLIN) 0005: STRYKER IV POLES
Specification NumberMinimum Technical Specifications (SPEC)Capable of Meeting This SPEC (Y/N)Alternate/Equal Brand Part NumberLocation in Literature Which Indicates SC is MetVendor Comments
SC 1Must have a minimum of 1 permanent collapsible IV pole
General DescriptionCapable of Providing Product (Y/N)Alternate/Equal Brand Part NumberLocation in LiteratureVendor Comments
0005AA0785-155-000IV CADDY
0005AB1105-035-33730IN IV POLE 3 STAGE HE PR
0005AC1105-035-33830IN IV POLE 2 STAGE HE PL
0005AD1105-035-33930IN IV POLE 3 STAGE FE PR
0005AE1105-035-34030IN IV POLE 2 STAGE FE PL
0005AF1105-035-34130IN IV POLE 2 STAGE HE PR
0005AG1105-035-34230IN IV POLE 3 STAGE HE PL
0005AH1105-035-34330IN IV POLE 2 STAGE FE PR
0005AJ1105-035-34430IN IV POLE 3 STAGE FE PL
0005AK1105-035-36130IN IV POLE 3 STAGE FE PR
0005AL1105-035-36230IN IV POLE 2 STAGE FE PL
0005AM1105-035-36330IN IV POLE 2 STAGE FE PR
0005AN1105-035-36730IN IV POLE 2 STAGE HE PL
0005AP1105-035-36830IN IV POLE 2 STAGE HE PR
0005AQ1105-035-36930IN IV POLE 3 STAGE HE PL
0005AR1125-035-3382 Stage Permanent Fold IV Pole - Head Left
0005AS1125-035-3412 Stage Permanent Fold IV Pole - Head Rt.
ACCESSORIES
CLINProduct PNGeneral DescriptionCapable of Providing Product (Y/N)Vendor Part NumberLocation in LiteratureVendor Comments
00061001-052-000Siderail Pads
00071008-015-020Foot end Nursing Controls
00081105-045-022HEEL PAD ASSEMBLY
00091105-045-500FOOTBOARD/CHARTHOLDER, WHITE
00101105-045-700SERVING TRAY, WHITE
00111105-900-292Custom Label
00121115-130-000UPRIGHT BOTTLE HOLDER, WHITE
00131806-034-300IsoFlex SE (Mattress)
00141018-025-3654 Sided Brake
00151105-003-220FRAME ASSY, SIDE CONTROL BRAKE
00161115-003-004SIDE CONTROL BRAKES
Hydraulic ControlsLocation in Literature
00171105-005-5103-Sided Hydraulics
00181115-005-610Three Sided Hydraulic Controls
Hydraulic Knee GatchLocation in Literature
00191105-010-303Pneumatic Backrest/Hydraulic Knee Gatch
Integrated scale systemLocation in Literature
00201070-010-001OPTION, SCALES
00211070-010-002OPTION, SCALES
00221070-010-100ASSEMBLY, SCALES LITTER
00231070-060-360OPTION, SCALE
LiftAssist Backrest/ Stationary FootLocation in Literature
00241105-010-30430IN DROP SEAT STATIONARY FOOT
Pop-up push handles (1105 and 1115 only)Location in Literature
00251105-048-030PUSH HANDLE ASSEMBLY 30IN
00261105-048-060ASSY, PUSH HANDLES, HE,
Recovery Chair PositionLocation in Literature
00271105-010-30230IN DROP SEAT W/GATCH WHITE