JAN 23 Consolidation - Schedule of Line Items with - QAs - Updated 4-26-23.xlsx

XLSX spreadsheet 52 KB Posted

Attached to
6525--January 2023 Consolidation
Solicitation number
36A79723Q0004
Issued by

View the file

Other files

File Type Posted
662B30001 - 5343B5016 TS.zip ZIP file
693B30005 BM.zip ZIP file
Amendment 0001 - Continuation Page.pdf PDF
598B30004 - 662B30000 TS.zip ZIP file
504B30001 - 565B39003 TS.zip ZIP file
565B39004 - 593B30014 TS.zip ZIP file
36A79723Q0004 0001.docx DOCX document
VA Directive 6550 - New Appendix A - published Jun. 2019.pdf PDF
MAX Drive HTME User Guide.pdf PDF
537B38004 - 5343B5020 TS.zip ZIP file
590B39006 - 695B38011 TS.zip ZIP file
RFQ Instructions to Offerors - JAN 2023 Consolidation - Updated 3-29-23.pdf PDF
January 2023 Consolidation Schedule.pdf PDF
Memorandum for Turnkey.pdf PDF
593B30014 - 646B32001 TS.zip ZIP file
Vendor Workup Spreadsheet - 36A79723Q0004.xlsx XLSX spreadsheet
36A79723Q0004_1.docx DOCX document
Vendor Folders.zip ZIP file
565B39004 - 581B31001 TS.zip ZIP file
646B32002 - 675B37004 TS.zip ZIP file
644B38014 - 693B30005 BM.zip ZIP file
675B37005 - 757B30006 TS.zip ZIP file
JAN 23 Consolidation - Schedule of Line Items - Updated 3-29-23.xlsx XLSX spreadsheet
504B30001 - 534B33004 TS.zip ZIP file
Memorandum for Training.pdf PDF
506B30019 - 623B34008 BM.zip ZIP file
Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Jan 23 Schedule of Line Items

HTME VISNStationRequisition Number in ActionEquipment TypeQTYBM/TS
VISN 17: VA Heart of Texas Health Care Network504 AMARILLO, TX504B30001XR CATH LAB1TS
VISN 10: VA Healthcare System of Ohio506 ANN ARBOR, MI506B30019XR HYBRID1BM
VISN 10: VA Healthcare System of Ohio506 ANN ARBOR, MI506B30025XR US1BM
VISN 10: VA Healthcare System of Ohio506 ANN ARBOR, MI506B30026XR PORT CARM1BM
VISN 7: VA Southeast Health Care Network508 DECATUR, GA508B32004NM SPECT CT1BM
VISN 7: VA Southeast Health Care Network509 AUGUSTA, GA509B32015XR RAD1TS
VISN 7: VA Southeast Health Care Network509 AUGUSTA, GA509B32016XR RAD1TS
VISN 7: VA Southeast Health Care Network509 AUGUSTA, GA509B32017XR MRI1TS
VISN 7: VA Southeast Health Care Network509 AUGUSTA, GA509B32018XR CATH LAB IR1TS
VISN 5: VA Capitol Health Care Network512 BALTIMORE, MD512B31007XR PORT C-ARM1TS
VISN 5: VA Capitol Health Care Network512 BALTIMORE, MD512B31008XR RAD1TS
VISN 5: VA Capitol Health Care Network517 BECKLEY, WV517B31001XR PORT RAD2TS
VISN 20: VA Northwest Network531 BOISE, ID531B32213XR CT1TS
VISN 7: VA Southeast Health Care Network534 CHARLESTON, SC5343B5016XR RF1TS
VISN 7: VA Southeast Health Care Network534 CHARLESTON, SC5343B5017XR CATH LAB IR1TS
VISN 7: VA Southeast Health Care Network534 CHARLESTON, SC5343B5020XR CATH LAB C1TS
VISN 7: VA Southeast Health Care Network534 CHARLESTON, SC534B33004XR RF1TS
VISN 12: VA Great Lakes Health Care System537 CHICAGO, IL537B38004XR MAMMO1TS
VISN 12: VA Great Lakes Health Care System537 CHICAGO, IL537B38005XR MAMMO2TS
VISN 12: VA Great Lakes Health Care System537 CHICAGO, IL537B38006XR US2TS
VISN 7: VA Southeast Health Care Network544 COLUMBIA, SC544B32009XR RF1BM
VISN 17: VA Heart of Texas Health Care Network549 DALLAS, TX549B30451XR HYBRID1TS
VISN 10: VA Healthcare System of Ohio552 DAYTON, OH552B20003XR CATH LAB1BM
VISN 10: VA Healthcare System of Ohio553 DETROIT, MI553B30009XR US4BM
VISN 10: VA Healthcare System of Ohio554 DETROIT, MI553B30010XR RAD1BM
VISN 10: VA Healthcare System of Ohio555 DETROIT, MI553B30011XR RAD1BM
VISN 10: VA Healthcare System of Ohio556 DETROIT, MI553B30012XR RAD1BM
VISN 10: VA Healthcare System of Ohio557 DETROIT, MI553B30015XR RAD1BM
VISN 10: VA Healthcare System of Ohio559 DETROIT, MI553B30017XR US4BM
VISN 19: VA Rocky Mountain Network554 AURORA, CO554B33004XR US1TS
VISN 2: VA Healthcare Network Upstate New York561 EAST ORANGE, NJ561B20030XR US1BM
VISN 6: VA Mid-Atlantic Health Care Network565 FAYETTEVILLE, NC565B39002XR CT1TS
VISN 6: VA Mid-Atlantic Health Care Network565 FAYETTEVILLE, NC565B39003XR RAD1TS
VISN 6: VA Mid-Atlantic Health Care Network565 FAYETTEVILLE, NC565B39004XR RF1TS
VISN 6: VA Mid-Atlantic Health Care Network565 FAYETTEVILLE, NC565B39005XR US7TS
VISN 21: VA Sierra Pacific Network570 FRESNO, CA570B30004XR US1TS
VISN 21: VA Sierra Pacific Network570 FRESNO, CA570B30005XR RAD1TS
VISN 8: VA Sunshine Healthcare Network573 GAINESVILLE, FL573B35006XR RF1TS
VISN 8: VA Sunshine Healthcare Network573 GAINESVILLE, FL573B35007XR RAD1TS
VISN 8: VA Sunshine Healthcare Network573 GAINESVILLE, FL573B35008XR PORT C-ARM1TS
VISN 8: VA Sunshine Healthcare Network573 GAINESVILLE, FL573B35009XR PORT C-ARM1TS
VISN 8: VA Sunshine Healthcare Network573 GAINESVILLE, FL573B35010XR PORT C-ARM5TS
VISN 12: VA Great Lakes Health Care System578 HINES, IL578B38001XR US1BM
VISN 5: VA Capitol Health Care Network581 HUNTINGTON, WV581B31001XR US1TS
VISN 6: VA Mid-Atlantic Health Care Network590 HAMPTON, NY590B39006NM PET CT1TS
VISN 21: VA Sierra Pacific Network593 LAS VEGAS, NV593B30014XR CT1TS
VISN 21: VA Sierra Pacific Network593 LAS VEGAS, NV593B30017XR CT1TS
VISN 4: VA Stars & Stripes Healthcare Network595 LEBANON, PA595B39003XR C-ARM1TS
VISN 9: VA Mid South Healthcare Network596 LEXINGTON, KY596B30005NM BONE DEN1TS
VISN 16: South Central VA Health Care Network598 LITTLE ROCK, AR598B30004XR US1TS
VISN 16: South Central VA Health Care Network598 LITTLE ROCK, AR598B30006XR US1TS
VISN 22: VA Desert Pacific Healthcare Network605 LOMA LINDA, CA605B20027WORKSTATION1BM
VISN 21: VA Sierra Pacific Network612 MATHER, CA612B39001XR CT1TS
VISN 5: VA Capitol Health Care Network613 MARTINSBURG, WV613B31006XR RAD1TS
VISN 5: VA Capitol Health Care Network613 MARTINSBURG, WV613B31007XR RF1TS
VISN 7: VA Southeast Health Care Network619 MONTGOMERY, AL619B32006XR URO1BM
VISN 7: VA Southeast Health Care Network619 MONTGOMERY, AL619B32007XR RF1BM
VISN 19: VA Rocky Mountain Network623 MUSKOGEE, OK623B34008XR US1BM
VISN 21: VA Sierra Pacific Network640 PALO ALTO, CA640B34003XR RF1TS
VISN 22: VA Desert Pacific Healthcare Network644 PHOENIX, AZ644B38014NM PET CT1BM
VISN 4: VA Stars & Stripes Healthcare Network646 PITTSBURGH, PA646B32001XR CATH LAB1TS
VISN 4: VA Stars & Stripes Healthcare Network646 PITTSBURGH, PA646B32002XR CATH LAB1TS
VISN 4: VA Stars & Stripes Healthcare Network646 PITTSBURGH, PA646B32004XR EP LAB1TS
VISN 20: VA Northwest Network648 PORTLAND, OR648B38011XR MRI1TS
VISN 6: VA Mid-Atlantic Health Care Network652 RICHMOND, VA652B29004XR US1BM
VISN 6: VA Mid-Atlantic Health Care Network652 RICHMOND, VA652B29005XR US1BM
VISN 6: VA Mid-Atlantic Health Care Network652 RICHMOND, VA652B39005XR MRI1BM
VISN 6: VA Mid-Atlantic Health Care Network652 RICHMOND, VA652B39006XR MRI1BM
VISN 6: VA Mid-Atlantic Health Care Network652 RICHMOND, VA652B39007NM SPECT1BM
VISN 6: VA Mid-Atlantic Health Care Network652 RICHMOND, VA652B39008NM PET CT1BM
VISN 6: VA Mid-Atlantic Health Care Network652 RICHMOND, VA652B39009NM SPECT CT1BM
VISN 6: VA Mid-Atlantic Health Care Network652 RICHMOND, VA652B39010XR CT1BM
VISN 6: VA Mid-Atlantic Health Care Network652 RICHMOND, VA652B39011XR CT1BM
VISN 6: VA Mid-Atlantic Health Care Network652 RICHMOND, VA652B39012XR RF1BM
VISN 6: VA Mid-Atlantic Health Care Network652 RICHMOND, VA652B39013XR RAD3BM
VISN 6: VA Mid-Atlantic Health Care Network652 RICHMOND, VA652B39014XR CATH LAB IR1BM
VISN 6: VA Mid-Atlantic Health Care Network652 RICHMOND, VA652B39015XR MAMMO1BM
VISN 6: VA Mid-Atlantic Health Care Network659 SALISBURY, NC659B29004XR US4TS
VISN 21: VA Sierra Pacific Network662 SAN FRANCIS, CA662B30000XR CATH LAB C1TS
VISN 21: VA Sierra Pacific Network662 SAN FRANCIS, CA662B30001XR MRI1TS
VISN 17: VA Heart of Texas Health Care Network671 SAN ANTONIO, TX671B30015XR RAD1TS
VISN 8: VA Sunshine Healthcare Network675 ORLANDO, FL675B37002XR US3TS
VISN 8: VA Sunshine Healthcare Network675 ORLANDO, FL675B37003XR US1TS
VISN 8: VA Sunshine Healthcare Network675 ORLANDO, FL675B37004XR PORT C-ARM1TS
VISN 8: VA Sunshine Healthcare Network675 ORLANDO, FL675B37005XR US1TS
VISN 12: VA Great Lakes Health Care System676 TOMAH, WI676B37008XR PORT C-ARM1BM
VISN 22: VA Desert Pacific Healthcare Network678 TUCSON, AZ678B32002XR US1BM
VISN 5: VA Capitol Health Care Network688 WASHINGTON, DC688B30005XR CATH LAB C1TS
VISN 5: VA Capitol Health Care Network688 WASHINGTON, DC688B30008XR URO1TS
VISN 4: VA Stars & Stripes Healthcare Network693 WILKES-BARRE, PA693B30004XR US1BM
VISN 4: VA Stars & Stripes Healthcare Network693 WILKES-BARRE, PA693B30005XR PORT RAD4BM
VISN 12: VA Great Lakes Health Care System695 MILWAUKEE, WI695B38009XR US4TS
VISN 12: VA Great Lakes Health Care System695 MILWAUKEE, WI695B38010XR US1TS
VISN 12: VA Great Lakes Health Care System695 MILWAUKEE, WI695B38011XR PORT RAD2TS
VISN 17: VA Heart of Texas Health Care Network740 HARLINGEN, TX740B30010XR US4TS
VISN 17: VA Heart of Texas Health Care Network740 HARLINGEN, TX740B30012XR RF MOBILE1TS
VISN 17: VA Heart of Texas Health Care Network756 EL PASO, TX756B35006XR MRI1TS
VISN 17: VA Heart of Texas Health Care Network756 EL PASO, TX756B35007XR CT1TS
VISN 10: VA Healthcare System of Ohio757 COLUMBUS, OH757B30003XR US1TS
VISN 10: VA Healthcare System of Ohio757 COLUMBUS, OH757B30004XR US1TS
VISN 10: VA Healthcare System of Ohio757 COLUMBUS, OH757B30005XR US1TS
VISN 10: VA Healthcare System of Ohio757 COLUMBUS, OH757B30006XR US1TS

QAs

SortVISN #VISNStationRequisition NumberQUESTIONSGOVT Response
410VISN 10: VA Healthcare System of Ohio506 ANN ARBOR, MI506B30026This is labeled XR Port Rad but is clearly a 3D C-Arm. Can you tell us what department this will be used in? Everything leads to mobile C-Arm but we wanted to check.The modality should be XR Port C Arm. The device will be used by the Respiratory Therapy department.
5410VISN 10: VA Healthcare System of Ohio552 DAYTON, OH552B20003What disciplines will use this room? (Cardiac Cath, EP, Vascular?)Cardia Cath and EP will use the room. All peripheral vascular is done in IR/Surgery
5510VISN 10: VA Healthcare System of Ohio552 DAYTON, OH552B20003What steps/initiatives are they taking to reduce dose to the patient and staff? How important is dose reduction?We use ALARA, rad pads, lead and time, distance for protection. Does reduction is extremely important.
5610VISN 10: VA Healthcare System of Ohio552 DAYTON, OH552B20003In terms of criteria, what are the top 3?Ease of use, newest technology, dose reduction capabilities
5710VISN 10: VA Healthcare System of Ohio552 DAYTON, OH552B20003Page 12 indicates an ISP radiology upgrade that would not apply to a Cath Lab as the obligation states. Please clarify requirement.Those items are moved to Added Value and will not be considered as part of the main technical specifications.
5810VISN 10: VA Healthcare System of Ohio552 DAYTON, OH552B20003In the quote on page 34, it is requesting an upgrade to Philips Intellispace, **NIC582, NICA797, FIC0163, 98901200844. To allow for competition, please remove this line item.Those items are moved to Added Value and will not be considered as part of the main technical specifications.
5910VISN 10: VA Healthcare System of Ohio552 DAYTON, OH552B20003Please provide the date of installation for the Philips Allura Xper FD10.The Cath Lab was installed November of 2009 and was updated in 2016
6010VISN 10: VA Healthcare System of Ohio554 DETROIT, MI553B300101): Please remove 12x9 as this is a non-standard detector size and change to a 10x12" to maximize competition: 2) Please remove 23.8" monitor as this is vendor specific 3) Is there trade in and de-installation of existing room required?1) This is based on a benchmark quote, site is open to 10 x12 “ detector size, 2) This is a benchmark quote 3) no trade in
6110VISN 10: VA Healthcare System of Ohio554 DETROIT, MI553B30010Please clarify if all wireless detectors are being offered and no fixed detectors. How many detectors would do you prefer?Two
6210VISN 10: VA Healthcare System of Ohio555 DETROIT, MI553B30011Please clarify if all wireless detectors are being offered (no fixed detectors), how many detectors would you like prefer?Two
6310VISN 10: VA Healthcare System of Ohio556 DETROIT, MI553B30012Please clarify if all wireless detectors are being offered and no fixed detectors. How many detectors would do you prefer?Two
6410VISN 10: VA Healthcare System of Ohio557 DETROIT, MI553B30015Please clarify if all wireless detectors are being offered and no fixed detectors. How many detectors would do you prefer?
Please clarify if this is a wall stand only configuration.This is a wall stand only configuration.
6510VISN 10: VA Healthcare System of Ohio559 DETROIT, MI553B30017Please change modality to XR US to match with benchmark or correct redacted quote if solicitation is supposed to be XR RAD.Yes, XR US
6610VISN 10: VA Healthcare System of Ohio559 DETROIT, MI553B30017The Benchmark file is labeled as XR RAD. Can you confirm if there are Trade-in Systems (if so provide the details)?Modality is XR US

Trade in Philips Epiq 7

27510VISN 10: VA Healthcare System of Ohio757 COLUMBUS, OH757B30006Could you expand the range of acceptable monitor size to include a minimum of 18 inches to allow for increased competition?
a. Minimum screen size [in]21”

Could you expand the range of acceptable active screen size to include a minimum of 18 inches to allow for increased competition?

b. Minimum active screen size [in]21”No, The minimum screen size of 21” is required.
27610VISN 10: VA Healthcare System of Ohio757 COLUMBUS, OH757B30006Section 8 Transducers - Can you verify if these are the only transducers required.
Section 9, a., b., c., and d. - Can you verify if these are required and there are no applicable transducers specified to complete these items.Yes, all transducers required for this acquisition have been included.

Yes, the features identified in Section 9, a, b, c, and d are required.

45 12 VISN 12: VA Great Lakes Health Care System 537 CHICAGO, IL 537B38004 1. Does Customer want a Vacuum system?

2. Does Customer want a biopsy chair?

3. Does Customer want ICAD?

4. Does Customer want to do needle locations?

5. Does customer need a CAD? If so is 2D or 3D CAD preferred? 1. Does Customer want a Vacuum system? Yes

2. Does Customer want a biopsy chair? Yes

3. Does Customer want ICAD? Not for stereotactic system

4. Does Customer want to do needle locations? Yes

5. Does customer need a CAD? If so is 2D or 3D CAD preferred? No CAD for stereotactic system 46 12 VISN 12: VA Great Lakes Health Care System 537 CHICAGO, IL 537B38004 Requirement Overview 15. Please clarify this is for 1 of 2 total systems for this requisition.

1.20c. Please change generator ampere range to 40-100mA.

1.24g. Please change SID to 66cm to allow full and fair competition

2. Additional Specifications. Please specify which vacuum assisted biopsy device you plan to use.

3. Technical Specifications. Please verify if you want 2D and 3D included.

3. Technical Specifications. Please clarify if this a prone position system.

5.54f. What is the Software version, Agfa PACS software version and Change PACS software version? Which one is used for storage, which is for reading of the mammography studies? Requirement Overview 15. Please clarify this is for 1 of 2 total systems for this requisition.

537B38004 is requesting one stereotactic mammography system. 537B38005 is requesting two 3D Mammography systems

1.20c. Please change generator ampere range to 40-100mA. Changed specs 1.24g. Please change SID to 66cm to allow full and fair competition Changed specs

2. Additional Specifications. Please specify which vacuum assisted biopsy device you plan to use. Depends on the vendor we use. Hologic Atec is an option. We are looking for a vacuum-assisted biopsy device for use for stereotactic and tomosynthesis guided biopsies.

3. Technical Specifications. Please verify if you want 2D and 3D included. yes 2D and 3D

3. Technical Specifications. Please clarify if this a prone position system. yes prone system. Would consider upright system as well 5.54f. What is the Software version, Agfa PACS software version and Change PACS software version? Which one is used for storage, which is for reading of the mammography studies? Version Agfa Impax is 6.55, Version Change (undecided until we know the go live date.). Site will eventually be transitioning from Agfa to Change Healthcare 47 12 VISN 12: VA Great Lakes Health Care System 537 CHICAGO, IL 537B38005 1. Does customer need Spot & Mag Views on 2 systems?

2. Does customer need 2D or 3D CAD? 1. Does customer need Spot & Mag Views on 2 systems? Yes, we need to do spot and mag views on both systems.

2. 2D CAD

48 12 VISN 12: VA Great Lakes Health Care System 537 CHICAGO, IL 537B38005 Requirement Overview. Please clarify if this requisition is Quantity 1 of 2 total systems for this site or if this requisition is 2 systems plus 1 system for requisition 537B38004.

3.48. CAD - AI Detection. Are you looking for 2D and 3D CAD.

3.49i. HD Imaging. Please remove as this is Vendor Specific.

4.56f. Curved compressions. Please remove Curved Compressions (small medium large) as this is Vendor Specific.

5.54f. What is the Software version, Agfa PACS software version and Change PACS software version? Which one is used for storage, which is for reading of the mammography studies? Requirement Overview. Please clarify if this requisition is Quantity 1 of 2 total systems for this site or if this requisition is 2 systems plus 1 system for requisition 537B38004.

537B38004 is requesting one stereotactic mammography system. 537B38005 is requesting two 3D Mammography systems

3.48. CAD - AI Detection. Are you looking for 2D and 3D CAD. 2D CAD 3.49i. HD Imaging. Please remove as this is Vendor Specific. Changed specs 4.56f. Curved compressions. Please remove Curved Compressions (small medium large) as this is Vendor Specific. Moved to added value 5.54f. What is the Software version, Agfa PACS software version and Change PACS software version? Which one is used for storage, which is for reading of the mammography studies? Version Agfa Impax is 6.55, Version Change (undecided until we know the go live date.). Site will eventually be transitioning from Agfa to Change Healthcare

24712VISN 12: VA Great Lakes Health Care System695 MILWAUKEE, WI695B38011Would you please remove the ET Tube placement specification as it limits competition?Moved to added value section to ensure requirements can be met by 2 vendors
24812VISN 12: VA Great Lakes Health Care System695 MILWAUKEE, WI695B38011Would you please remove the Pneumothorax detection specification as it only applies to one vendor?Moved to added value section to ensure requirements can be met by 2 vendors
24912VISN 12: VA Great Lakes Health Care System695 MILWAUKEE, WI695B38011Q: 1r) Please change tilt to -10/90 to maximize competition
2e) Please change to 150micron to maximize competitionOk, Changed tube tilt to requirement to -10/90

Ok, changed max pixel size to 150 micron

25012VISN 12: VA Great Lakes Health Care System695 MILWAUKEE, WI695B380111.39v. Please change maximum system dimensions to 54.52"x22.5" to allow for full and fair competition.
Please advise if detectors will be included with portable trade in. If so please include detector dimensions and verify if they are operational with software disks.Changed

Yes, each system has an operational 14x17 detector

25112VISN 12: VA Great Lakes Health Care System695 MILWAUKEE, WI695B38011Can the VA please comfirm if the use of standard transducers is required in system core configuration: C5-1 Abdominal/Hips, L12-3 Ergo Vascular/MSK, eL18-4 EMT Small Parts/MSK/Superficial?No, Meant for 695B38010?
25212VISN 12: VA Great Lakes Health Care System695 MILWAUKEE, WI695B38011Can the VA please confirm if Fusion-Targeted Biopsy System is required?No, Meant for 695B38010?
25312VISN 12: VA Great Lakes Health Care System695 MILWAUKEE, WI695B38011Can the VA please confirm if Cardiovascular Clinical, Mitral Valve Navigator, and/or Cardiac 3D Quantification is required?No, Meant for 695B38010?
25412VISN 12: VA Great Lakes Health Care System695 MILWAUKEE, WI695B3801125in (635mm) is unavailable on most portable systems. Please expand the specification (32in is reasonable).Ok, change min tube reach to 32”
25512VISN 12: VA Great Lakes Health Care System695 MILWAUKEE, WI695B38011+110/-10 is not available on most XR systems. Please expand the specification (+90/-10) to ensure maximum competitionOk, Change tube tilt to requirement to -10/90
25612VISN 12: VA Great Lakes Health Care System695 MILWAUKEE, WI695B38011100um is not a common specification in general DR, has a limited clinical application, and additional load for PACS storage/compatibility. Please relieve the specification to ensure maximum competition.
140um is reasonable for most clinical requirements.Ok, changed max pixel size to 150 micron
25712VISN 12: VA Great Lakes Health Care System695 MILWAUKEE, WI695B38011Please clarify if this means AEC (Automatic Exposure Control) or just automatic X-ray parameter setting.Ok, changed max pixel size to 150 micron
25812VISN 12: VA Great Lakes Health Care System695 MILWAUKEE, WI695B38011Please remove 'ET Tube placement' or modify to 'Tube enhancement software' to ensure maximum competition.Changed to automatic x-ray parameter setting
25912VISN 12: VA Great Lakes Health Care System695 MILWAUKEE, WI695B38011Pneumothorax detection' is not available for most portable DR systems. Please remove 'Pneumothorax detection' to ensure maximum competition.Moved to added value section to ensure requirements can be met by 2 vendors
12816VISN 16: South Central VA Health Care Network598 LITTLE ROCK, AR598B30004Is a touchscreen monitor clinically necessary?Moved to added value section to ensure requirements can be met by 2 vendors
12916VISN 16: South Central VA Health Care Network598 LITTLE ROCK, AR598B30006Can you please clarify if the requirement is for a volume (3D) or a 2D phased transducer?Yes, 3D capability desired
117VISN 17: VA Heart of Texas Health Care Network504 AMARILLO, TX504B300011. Section 1 Unit physical specifications , aa. Can you please change the minimum workstation requirement to 500GB in the interests of fair competitive competition?

2. Section Additional Specifications Line i. What size of Digital Detectors needed? Is there an injector needed? If so ceiling or floor? The requirement has been changed to 500GB The requirement for floor mounted injector has been included

217VISN 17: VA Heart of Texas Health Care Network504 AMARILLO, TX504B30001What size detector are you requesting?The requirement has been included to have to 12x12 in detector size
317VISN 17: VA Heart of Texas Health Care Network504 AMARILLO, TX504B300011. Please confirm if a UPS is desired, and if you require a full or partial UPS?

2. F. Rotational angiography Please clarify the need for Rotational angiography in the Cath Lab? If not needed, can this spec please be removed?

3. Please confirm if a new Injecotr is needed, or will an existing Injector be used? If existing, please provide details on what injector you have.

4. Would you like vendors to provide a Microphone communication System? Partial UPS required. The requirement has been changed to include a minimum total system run time of 15mins Requirement will remain as is. It is required The requirement for floor mounted injector has been included Yes the requirement has been changed to include the microphone communication system

5217VISN 17: VA Heart of Texas Health Care Network549 DALLAS, TX549B304511. Section 3 General Software Line J Can this characteristic be removed in there interests of fair competition? 2. Section 4 General Hardware Line d. Should the injector be ceiling or floor mounted?
3. Line f-Please clarify what type of UPS is requested-FULL 5-7 mins back up coverage or for workstations? 4. Added Value Section Line h. Per Turnkey Rubic from the NAC can not include ambient lightening (Human Factor systems for patient experience) please removeKeep specification as is. Enough vendors can meet this specification. The injector should be table-mounted per original specs

The UPS system needs to be able to keep workstations and system running for at least 10 minutes in order to close out case and get patient off table. The requirement will remain as is for the section line h, as this is not a turn key order.

5317VISN 17: VA Heart of Texas Health Care Network549 DALLAS, TX549B304516g: Ceiling Mounted - Please change this requirement to allow for more compettion and modern system architectures to include a laser-guided mobile gantry.Keep specification as is for ceiling-mounted system. Enough vendors can meet this specification.
20517VISN 17: VA Heart of Texas Health Care Network671 SAN ANTONIO, TX671B300151. Technical Requirements Section 1 Lines 19a-c Please clarify if the wall stand detector should be Fixed/static or do you want wireless detector for the wall stand?

2. Line 27: Please confirm that a total quantity of two wireless detectors is desired.

3. Line 59: In what application is Linear tomography requested for? Can this be removed as a minimum requirement to allow for more non vender specific bids?

4. Line 58: If the purpose of Dual-Energy is for bone suppression, please modify benchmark to say "Bone Suppression Capabilities" 1. The requirement will remain as is. Fixed detector on wall stand

2. Yes, total 2 (two) wireless detectors and 1 (one) fixed detector.

3. The requirement has been removed

4. The requirement will remain as is.

20617VISN 17: VA Heart of Texas Health Care Network671 SAN ANTONIO, TX671B30015a. Please verify if you are looking for a total of three 14x17 detectors for this system?The requirement will remain as is. 3 detectors total
20717VISN 17: VA Heart of Texas Health Care Network671 SAN ANTONIO, TX671B30015Can the VA please confirm that two 14x17” wireless detectors are required?Yes 2 (two) 14 X 17 wireless detectors
20817VISN 17: VA Heart of Texas Health Care Network671 SAN ANTONIO, TX671B30015Can the VA please confirm that the wireless detector weight limit does not apply to the fixed detector in the wall bucky?The requirement applies to both the fixed and wireless detectors
20917VISN 17: VA Heart of Texas Health Care Network671 SAN ANTONIO, TX671B30015Instead of physical grids for the wireless detector, will the VA accept gridless imaging software as an offering “exceeding expectations”?We would accept offerings of gridless imaging in addition to the physical attachment
21017VISN 17: VA Heart of Texas Health Care Network671 SAN ANTONIO, TX671B30015Will the VA please clarify if Section 3 subsection i. “Automatic tube crane, with protocol-based movement (option)?” is an option, value add, or required specification?The requirement will remain as is
21117VISN 17: VA Heart of Texas Health Care Network671 SAN ANTONIO, TX671B30015In Section 3 subsection n. the Compliance Matrix requests “Dual energy imaging,” while Section 5 subsection b. notes “Bone suppression.” As both these features achieve similar end results, can the VA please clarify if producing bone-suppressed images either via dual energy or bone suppression is acceptable, or if one option is preferable to the other?Dual energy is an absolute requirement. Bone suppression can be optional for now. The requirement will remain as is
21217VISN 17: VA Heart of Texas Health Care Network671 SAN ANTONIO, TX671B30015Will the VA please confirm that if only one workstation is required, then section 4 subsections c, d, e, and g are not needed?One acquisition workstation and one processing workstation required.
21317VISN 17: VA Heart of Texas Health Care Network671 SAN ANTONIO, TX671B30015Will the VA please clarify if the wireless detectors should be Cesium Iodide (CsI) based?Vendor should propose all offerings. No specification was set for this
21417VISN 17: VA Heart of Texas Health Care Network671 SAN ANTONIO, TX671B30015Will the VA please describe the desired weight-bearing capacity of each wireless detector with and without a protective cover?The requirement will remain as is. The absolute max is specified in the technical specifications
21517VISN 17: VA Heart of Texas Health Care Network671 SAN ANTONIO, TX671B30015Can the VA please confirm that linear tomography is an additonal required specification for the x-ray system?The requirement has been removed
21617VISN 17: VA Heart of Texas Health Care Network671 SAN ANTONIO, TX671B3001512in is not available for most XR room systems. Please open the specification to ensure maximum competition - (19in is reasonable).The minimum is set to 12in, please show all offerings within the set limit. The requirement will remain as is
21717VISN 17: VA Heart of Texas Health Care Network671 SAN ANTONIO, TX671B30015Motor-driven X-Y table top movement is not available for all DR room systems. It is a function for fluoroscopy. Please remove to ensure maximum competition.The requirement has been removed
21817VISN 17: VA Heart of Texas Health Care Network671 SAN ANTONIO, TX671B30015Please remove "Dual Energy" or modify to equivalent function of "bone suppression", which is to see soft tissue as the most common clinical requirement, to ensure maximum competition.The requirement will remain as is. Dual energy is required
21917VISN 17: VA Heart of Texas Health Care Network671 SAN ANTONIO, TX671B30015Please remove "Linear tomography" as this is not a common function for X-Ray. Does not ensure maximum competition.The requirement has been removed
22017VISN 17: VA Heart of Texas Health Care Network671 SAN ANTONIO, TX671B30015Please remove "Tomography' which is not common usage in general DR due to its processing speed and quality.The requirement has been removed
26017VISN 17: VA Heart of Texas Health Care Network740 HARLINGEN, TX740B30010Section #8, Line 94: Advance features in point B indicates the use of prostate scanning. There is no benchmark for an endo cavity probe listed under section 7. Will you need a endocavity probe? If so, please add to transducers section. If not, please clarify or remove the line 94 benchmark requirement.Please see the additional probes requested. This requirement has been modified
26117VISN 17: VA Heart of Texas Health Care Network740 HARLINGEN, TX740B30010Section 2 b., c., and d. - Can you verify if these are required?

Section 5 j - Can you verify if this is required?

Section 6 j., k., an l. - Can you verify if this is required?

Section 8 a. to h. - Can you verify if this is required?

All of the above items are typically not required for a system in the Pain Management Dept. Yes Yes Yes Yes These systems will be shared amongst services to include podiatry/pain/gynecology/cardiology and ortho

26217VISN 17: VA Heart of Texas Health Care Network740 HARLINGEN, TX740B30010Are 3D TTE and 3D TEE transducers required?No
26317VISN 17: VA Heart of Texas Health Care Network740 HARLINGEN, TX740B30012The documents (Compliance matrix and Tech spec) are labeled as XR PORT C ARM however the Schedule of Line items indicate, XR RF Mobile. Please confirm?Both names refer to the same equipment modality document
26417VISN 17: VA Heart of Texas Health Care Network756 EL PASO, TX756B350062.i not aware of a stepping table capability in MRI. Please consider removing this requirement for fair competitionThis has been removed
26517VISN 17: VA Heart of Texas Health Care Network756 EL PASO, TX756B350064.g this is a vendor specific capability. Please consider revising to a single acquisition station to allow fair competitionRequirement has been changed to one
26617VISN 17: VA Heart of Texas Health Care Network756 EL PASO, TX756B350061. Line 26: Please change the maximum weight not to exceed 16,250lbs to allow for less restrictive competition

2. Line 43: Please change the UPS minimum to 5-7 minutes to allow for less restrictive competition

3. Line 65: Can this specifications changed to say a rear MR bore LCD be acceptable to allow for less restrictive competition?

4. Line 65: This appears to have multiple requirements within the single line item. Please parse individual requirements to separate lines.

4. Line 68: Please change storage requirement to 500 GB to allow for less restrictive competition.

5. Line 129 "C" Per Memorandum of Training, the NAC will not approve off-site clinical applications training during the consolidation period. Please remove this line.

6. Line 130 "D" Per Memorandum of Training, the NAC will not approve off-site clinical applications training during the consolidation period. Please remove this line. 1. This requirement has been removed

2. Requirement will remain as is

3. Requirement has been changed to allow for rear bore LCD

4. Requirement has been changed to allow for rear bore LCD

5. Requirement will remain as is

6. Requirement will remain as is 267 17 VISN 17: VA Heart of Texas Health Care Network 756 EL PASO, TX 756B35006 1.f. Please change maximum Gradient Amplitude change to 45mT/m to allow full and fair competition 1.h. Please change Maximum system weight to15,000 lbs to allow full and fair competition

4. Please change 2nd Console monitor to optional/value add to allow full and fair competition 1.f. The requirement has been changed to 45mT/m 1.h. This requirement has been removed

4. This requirement has been changed to one for both

26817VISN 17: VA Heart of Texas Health Care Network756 EL PASO, TX756B350071.b Please consider changing minimium bore size to 78cm to promote fair competitionThis requirement has been changed to 78cm
26917VISN 17: VA Heart of Texas Health Care Network756 EL PASO, TX756B350071.f Please consider changing table height range to 40-94 to promote fair competitionRequirement will remain as is
27017VISN 17: VA Heart of Texas Health Care Network756 EL PASO, TX756B350071.i Please consider changing rotation time to 280ms to allow for fair competitionThe requirement has been changed to 280ms
27117VISN 17: VA Heart of Texas Health Care Network756 EL PASO, TX756B350071.k Is 5000lbs a physical limitation of the facility or can you consider increasing this to 5300lbs to promote fair competitionThe requirement has been changed to 5300lbs
27217VISN 17: VA Heart of Texas Health Care Network756 EL PASO, TX756B350073.a Please considering changing monitor size to 19" to promote fair competitionThe requirement has been changed to 19in for both workstations
27317VISN 17: VA Heart of Texas Health Care Network756 EL PASO, TX756B350071. Line 74 "C", Per Memorandum of Training, the NAC will not approve off-site clinical applications training during the consolidation period. Please remove this line.
2. Line 39: Please change the UPS minimum to 5-7 minutes to allow for less restrictive competition1. Requirement will remain as is

2. Requirement will remain as is 274 17 VISN 17: VA Heart of Texas Health Care Network 756 EL PASO, TX 756B35007 Please clarify if you need a Lung CAD solution or just Low Dose Lung screening capability?

Please change Minimum Slice Reconstructed width from .4mm- to .625 allow full and fair competition Please change Table Height range from floor 40-100cm to 50-100cm Please clarify if you would like a full or partial UPS Please remove 2p. Tin Filtration Tube Voltage Range 70-150kv as this is a Vendor Specific feature please adjust mA spec to industry standard minimum of 1200mA Please remove offsite Tech and Physician training to align with NAC instructions Please clarify minimum desired detector width to correspond to 128 slice spec. 40, 80, 160 mm Z axis coverage.

For the trade in, may we please have some more specifics?? What is the specifc model number that would indicate the size of the detector?? What is the estimated annual utilization on the CT tube and when was it last replaced?? 1. Low dose capability

2. The requirement has been changed to 0.625mm

3. Requirement will remain as is

4. Partial UPS

5. Requirement will remain as is

6. Requirement will remain as is

7. The requirement has been changed to 40, 80, 160 mm Z axis coverage

8. The model information is as provided by the manufacturer in our inventory

3420VISN 20: VA Northwest Network531 BOISE, ID531B322131.b Please consider changing minimium bore size to 78cm to promote fair competitionRequest approved and updated specs.
3520VISN 20: VA Northwest Network531 BOISE, ID531B322131.f Please consider changing table height range to 55-94 to promote fair competitionRequest approved and updated specs.
3620VISN 20: VA Northwest Network531 BOISE, ID531B322132b. Snapshot is a vendor specific marketing product. Please remove to promote fair competitionRequest approved and updated specs.
3720VISN 20: VA Northwest Network531 BOISE, ID531B322133.a Please considering changing monitor size to 19" to promote fair competitionRequest approved and updated specs.
3820VISN 20: VA Northwest Network531 BOISE, ID531B32213Please verify if you are looking for a Full UPS or partial UPSFull
17120VISN 20: VA Northwest Network648 PORTLAND, OR648B38011Please change minimum bore depth to 105cm to allow full and fair competition

Please change maximum system dimensions to 100x100x100in to allow full and fair competition Please change minimum patient table load to 500lbs to allow full and fair competition Please change ceiling mounted injector to pedestal injector to align to industry safety standards Please remove OFF site clinical applications for technologists to align with NAC instructions of no offsite training

Please remove OFF site clinical applications for physicians to align with NAC instructions of no offsite trainingAccepted all of the requests.
8921VISN 21: VA Sierra Pacific Network570 FRESNO, CA570B30004Section # 8 - do you plan to scan prostates? If so, should an Endocavity probe be listed/required?No prostate scans will be done. Endocavity probe is not needed. Removed 8b
9021VISN 21: VA Sierra Pacific Network570 FRESNO, CA570B30004Request the following be removed or added to Value Add: 8.e Ability to overlay previous biopsy images on top of real-time prostate images, 8.f 3D-generated model of prostate that can be exported to report adjusted by additional non-imaging information, such as pathology-related data, and 8.g Semi-robotic arm.Requirements moved to Added Value section.
9121VISN 21: VA Sierra Pacific Network570 FRESNO, CA570B300051) Please reduce pixel pitch requiremnt to 139micron to broaden competition 3) Mechanical indexes for positoining (2pieces) - Can you elaborate on the use case for this item? 4a) Min Acquisition workstation monitor 24" - Please lower to 23" to broaden competition1) Changed pixel pitch to 140 micron 3) Removed mechanical indexes requirement 4a) Reduced minimum acquisition monitor size to 23”
9221VISN 21: VA Sierra Pacific Network570 FRESNO, CA570B30005Please change 17x17 detector weight to 8.4lbs to allow full and fair competition

Please change 14x17 detector weight to 7lbs to allow full and fair competition Please remove Pregnancy status to allow full and fair competition

Please clarify what the clinical ask for Mechanical Indexes for position 2 pieces isChanged weight specs on 17x17 detector to 8.5 lbs. Removed mechanical indexes requirement
9321VISN 21: VA Sierra Pacific Network570 FRESNO, CA570B300056.17lbs for a 17"x17" detector with battery is very uncommon for most XR room systems. Considering that the detector will be used and reside in the wall bucky, please relieve the specification to 9 lbs to ensure maximum competition.Changed requirement to 8.5 lbs
9421VISN 21: VA Sierra Pacific Network570 FRESNO, CA570B3000512.4in is not available for most XR room systems. Please open the specification to ensure maximum competition - (19in is reasonable).Changed requirement to 20 inches
9521VISN 21: VA Sierra Pacific Network570 FRESNO, CA570B30005650lbs requirement is on most DR systems. Please expand to 400~500lbs to increase competition.Multiple vendors can meet this requirement.
9621VISN 21: VA Sierra Pacific Network570 FRESNO, CA570B30005Motor-driven X-Y table top movement is not available for all DR room system. It is a function for fluoroscopy. Please remove to ensure maximum competition.Moved to Added Value
11421VISN 21: VA Sierra Pacific Network593 LAS VEGAS, NV593B300141.b Please consider changing minimium bore size to 78cm to promote fair competitionChanged to 78cm
11521VISN 21: VA Sierra Pacific Network593 LAS VEGAS, NV593B300141.f Please consider revising max mA to 900 to allow fair competitionChanged to 900 mA
11621VISN 21: VA Sierra Pacific Network593 LAS VEGAS, NV593B300141.g Please consider changing table height range to 55-94 to promote fair competitionChanged to 55-94
11721VISN 21: VA Sierra Pacific Network593 LAS VEGAS, NV593B300141.j please consider revising to 0.5mm to promote fair competitionChanged to 0.5mm
11821VISN 21: VA Sierra Pacific Network593 LAS VEGAS, NV593B300141.l Please consider increasing system max length to 90" to promote fair competitionChanged to 90”
11921VISN 21: VA Sierra Pacific Network593 LAS VEGAS, NV593B30014Please clarify full or partial UPS

Do you plan to process stroke on the console or a post processing workstation Please verify if you are looking for a low dose lung screening program or in fact a full Lung CAD solution? Full Either – Please see stipulation in section 3 Full Lung CAD; removed “within one-second” from 2.q

12021VISN 21: VA Sierra Pacific Network593 LAS VEGAS, NV593B300171.b Please consider changing minimium bore size to 78cm to promote fair competitionChanged to 78cm
12121VISN 21: VA Sierra Pacific Network593 LAS VEGAS, NV593B300171.f Please consider revising max mA to 900 to allow fair competitionChanged to 900 mA
12221VISN 21: VA Sierra Pacific Network593 LAS VEGAS, NV593B300171.g Please consider changing table height range to 55-94 to promote fair competitionChanged to 55-94
12321VISN 21: VA Sierra Pacific Network593 LAS VEGAS, NV593B300171.j please consider revising to 0.5mm to promote fair competitionChanged to 0.5mm
12421VISN 21: VA Sierra Pacific Network593 LAS VEGAS, NV593B300171.l Please consider increasing system max length to 90" to promote fair competitionChanged to 90”
12521VISN 21: VA Sierra Pacific Network593 LAS VEGAS, NV593B30017Please clarify full or partial UPS

Do you plan to process stroke on the console or a post processing workstation Please verify if you are looking for a low dose lung screening program or in fact a full Lung CAD solution? Full Either – Please see stipulation in section 3 Full Lung CAD; removed “within one-second” from 2.q

13021VISN 21: VA Sierra Pacific Network612 MATHER, CA612B39001Please clarify if you are seeking a full or partial UPS
Please verify the trade in system for this offer, is the Canon Aquilion One Genesis listed in fact the correct system being traded in?Partial UPS.

Trade in system in tech specs is correct.

13821VISN 21: VA Sierra Pacific Network640 PALO ALTO, CA640B340031) Would a non-tradional pullover tower style remote control room with an overhead tube be considered?No, we do not want another remote room
13921VISN 21: VA Sierra Pacific Network640 PALO ALTO, CA640B34003The tech spec and matrix seem to not align with each other. It looks like the PDF may be correct, and the excel was not filled in to match. Can you please confirm?Tech Specs were edited and Matrix was re-generated
14021VISN 21: VA Sierra Pacific Network640 PALO ALTO, CA640B34003Note: The Vendor Matrix Excel and PDF do not align on this obligation.

Please change Table detector from wireless to fixed to allow full and fair competition Please clarify if you would like a Full or Partial UPS Please remove changing from upright bucky from tube head functionality to allow full and fair competition Please advise if you would prefer the in room monitor (in the exam room) ceiling mounted or on a mobile cart?

Please change maximum lowest table height from floor from 60” to 39” to align with industry standards Please remove free floating manual table top to allow full and fair competition Please remove bone suppression to allow full and fair competition

Please clarify what HIPPA requirements you are requesting?Changes have been made to Tech Specs to reflect the following:
a.Table detector changed to Fixed, though wireless is also acceptable.
b.Removed requirement to be able to change between tabletop, upright bucky and table bucky from tube head.
c.Changed max lowest table height to 39”.
d.Removed requirement for free floating manual table top.
•UPS required is as listed: full functionality for 10 minutes.
•Ceiling mounted monitors are desired.
•We need bone suppression.

HIPPA requirements are listed as “if possible”. Whatever the vendor has available in a package.

20121VISN 21: VA Sierra Pacific Network662 SAN FRANCIS, CA662B30000Line 26 on technical specifications spreadsheet indicatees11" as table height range - this is less than any vendors capability - is this correct? If not, please specify.Requirement removed.
20221VISN 21: VA Sierra Pacific Network662 SAN FRANCIS, CA662B300002o. Please clarify if you are asking for a MAC LAB in addition to this offer or are you looking for us to integrate with your existing hemodynamic system?
Please clarify if you are looking for a Full or Partial UPSTo integrate with the existing MacLab AltiX system

Full UPS

20321VISN 21: VA Sierra Pacific Network662 SAN FRANCIS, CA662B30001Minimum number of channels is listed as 64 - is this within a FOV of 50 cm?Yes
20421VISN 21: VA Sierra Pacific Network662 SAN FRANCIS, CA662B30001Please verify if you do have a Trade in to include in this obligation? Please include System ID, Serial Number, Cryogen levels and channel count.

Please clarify if you specially want an endorectal coil or would like the clinical capability to do prostate?

Please remove Offsite clinical applications for technologists per NAC proposal guidance Please remove offsite clinical applications for physicians per NAC proposal guidance Trade-in specified.

Prostate.

Off-site clinical training removed.

141 22 VISN 22: VA Desert Pacific Healthcare Network 644 PHOENIX, AZ 644B38014 Please verify if there is a trade in to be included in this obligation? If so please provide system, install date, Serial Number and Asset ID.

Please clarify how much Applications Traning should be included, the BM appears to only include 1 day?

Should vendors include an ECG trigger?

Should vendors include a Main disconnect panel?

Should vendors include Calcium Scoring?Trade in information:
ManufacturerSiemens
ModelBiograph mCT
EE/Asset Number67726
Serial Number11056

Current Condition Operational Installation Date 2011

Contrast Injector

ManufacturerMedrad
ModelStellant
EE/Asset Number87248
Serial Number301422642692

Current Condition Operational Installation Date 2011

There should be: Pre-installation clinical applications training, on-site clinical applications training during go live, and on site follow-up clinical application training.

Yes, ECG trigger should be included.

Yes, a Main disconnect panel should be included.

Yes, Calcium Scoring should be included.

23122VISN 22: VA Desert Pacific Healthcare Network678 TUCSON, AZ678B32002Is this ultrasound system going to be located in Interventional Radiology?No – this system will be utilized in the Facility Pain Clinic
1264VISN 4: VA Stars & Stripes Healthcare Network595 LEBANON, PA595B39003What navigation system or tool are you utilizing for your bronchoscopy?Medtronic Illumisite
1424VISN 4: VA Stars & Stripes Healthcare Network646 PITTSBURGH, PA646B320011.g Please consider minimum requirement of 27-42 inches to promote fair competitionMade requested change
1434VISN 4: VA Stars & Stripes Healthcare Network646 PITTSBURGH, PA646B320011.h Please consider minimum requirement of 7.9 inches of table lateral movement to promote fair competition.Made requested change
1444VISN 4: VA Stars & Stripes Healthcare Network646 PITTSBURGH, PA646B320011.l Please consider minimum requirement of 27-42 inches to promote fair competitionUnsure of ask as this addressed a different spec.
1454VISN 4: VA Stars & Stripes Healthcare Network646 PITTSBURGH, PA646B320011.v Please confirm you would like quantity of “3” additional exam room monitors in addition to the 54” monitor requirement in line 1.xClarified total quantity of monitors and sizes requested.
1464VISN 4: VA Stars & Stripes Healthcare Network646 PITTSBURGH, PA646B320012.q Please consider removing this line item to promote fair competitionCurrent practice is to use touchscreen now.
1474VISN 4: VA Stars & Stripes Healthcare Network646 PITTSBURGH, PA646B320013.c Please indicate if this is valvular or vasculature stenosis?Updated to Vasculature Stenosis
1484VISN 4: VA Stars & Stripes Healthcare Network646 PITTSBURGH, PA646B32002Please confirm that specs are for Cathlab and Not an R/F system as stated in line item 13.This system serves multiple uses at VAPHS and we feel that the IR specs better encapsulate the ask for this system. Adjusted phrasing on first section to better reflect the ask.
1494VISN 4: VA Stars & Stripes Healthcare Network646 PITTSBURGH, PA646B320021.a Please consider minimum requirement of 12 x 16 inches to promote fair competition.Since the device is used for EP cases, the larger detector provides a better FOV.
1504VISN 4: VA Stars & Stripes Healthcare Network646 PITTSBURGH, PA646B320021.c Please consider minimum requirement of 2 inches to promote fair competitionMinimum listed is less than 2in. Changed minimum value to in to reflect more accurately.
1514VISN 4: VA Stars & Stripes Healthcare Network646 PITTSBURGH, PA646B320021.e Please consider minimum requirement of 294- 45.5 cm to promote fair competition.2Made requested change
1524VISN 4: VA Stars & Stripes Healthcare Network646 PITTSBURGH, PA646B320021.f Please consider minimum requirement of 72-106 cm to promote fair competition.Made requested change
1534VISN 4: VA Stars & Stripes Healthcare Network646 PITTSBURGH, PA646B320021.g Please consider minimum requirement of 20 cm to promote fair competition.Made requested change
1544VISN 4: VA Stars & Stripes Healthcare Network646 PITTSBURGH, PA646B320022.f Please elaborate on “integrated” lead shieldingRemoved Requirement
1554VISN 4: VA Stars & Stripes Healthcare Network646 PITTSBURGH, PA646B320022.m Please remove to promote fair competitionMade requested change