36A79720Q0003 0001 01-TEAM A - Vendor Q_A September 2019 Consolidation - 12.31.2019.xlsx

View the file

Other files

File Type Posted
36A79720Q0003-0002000.docx DOCX document
36A79720Q0003-0002001.zip ZIP file
36A79720Q0003-0001357.zip ZIP file
36A79720Q0003-0001380.zip ZIP file
36A79720Q0003-0001375.zip ZIP file
36A79720Q0003-0001353.pdf PDF
36A79720Q0003-0001359.zip ZIP file
36A79720Q0003-0001374.zip ZIP file
36A79720Q0003-0001369.zip ZIP file
36A79720Q0003-0001386.zip ZIP file
36A79720Q0003-0001372.zip ZIP file
36A79720Q0003-0001373.zip ZIP file
36A79720Q0003-0001360.zip ZIP file
36A79720Q0003-0001385.zip ZIP file
36A79720Q0003-0001368.zip ZIP file
36A79720Q0003-0001377.zip ZIP file
36A79720Q0003-0001352.pdf PDF
36A79720Q0003-0001378.zip ZIP file
36A79720Q0003-0001361.zip ZIP file
36A79720Q0003-0001366.zip ZIP file
36A79720Q0003-0001388.zip ZIP file
36A79720Q0003-0001371.zip ZIP file
36A79720Q0003-0001387.zip ZIP file
36A79720Q0003-0001367.zip ZIP file
36A79720Q0003-0001389.zip ZIP file
36A79720Q0003-0001362.zip ZIP file
36A79720Q0003-0001351.docx DOCX document
36A79720Q0003-0001376.zip ZIP file
36A79720Q0003-0001379.zip ZIP file
36A79720Q0003-0001363.zip ZIP file
36A79720Q0003-0001382.zip ZIP file
36A79720Q0003-0001358.zip ZIP file
36A79720Q0003-0001384.zip ZIP file
36A79720Q0003-0001364.zip ZIP file
36A79720Q0003-0001383.zip ZIP file
36A79720Q0003-0001381.zip ZIP file
36A79720Q0003-0001370.zip ZIP file
36A79720Q0003-0001356.zip ZIP file
36A79720Q0003-0001365.zip ZIP file
36A79720Q0003-0001355.zip ZIP file
36A79720Q0003-042.zip ZIP file
36A79720Q0003-047.zip ZIP file
36A79720Q0003-057.zip ZIP file
36A79720Q0003-060.zip ZIP file
36A79720Q0003-064.zip ZIP file
36A79720Q0003-017.pdf PDF
36A79720Q0003-009.zip ZIP file
36A79720Q0003-005.pdf PDF
36A79720Q0003-058.zip ZIP file
36A79720Q0003-021.zip ZIP file
Show 40 more

Latest 50 of 180 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Team A

Requisition Number in ActionHTME VISNConsolidation PeriodConsolidation TypeEquipment TypeStationColumn1
402B91001VISN 01: VA New England Healthcare SystemSEP 2019CONSOLIDATIONXR RAD402 AUGUSTA, ME
402B91002VISN 01: VA New England Healthcare SystemSEP 2019CONSOLIDATIONXR RF402 AUGUSTA, ME
402B91003VISN 01: VA New England Healthcare SystemSEP 2019CONSOLIDATIONXR MRI402 AUGUSTA, ME
523B91005VISN 01: VA New England Healthcare SystemSEP 2019CONSOLIDATIONXR RF523 W ROXBURY, MA
523B91016VISN 01: VA New England Healthcare SystemSEP 2019CONSOLIDATIONRT LINAC523 BOSTON, MA
608B93006VISN 01: VA New England Healthcare SystemSEP 2019CONSOLIDATIONXR RAD608 MANCHESTER, NH
561B82013VISN 02: VA Healthcare Network Upstate New YorkSEP 2019CONSOLIDATIONXR MRI561 LYONS, NJ
630B90044VISN 02: VA Healthcare Network Upstate New YorkSEP 2019CONSOLIDATIONXR CT630 BROOKLYN, NY
595B99012VISN 04: VA Stars & Stripes Healthcare NetworkSEP 2019CONSOLIDATIONXR RAD595 LEBANON, PA
646B92005VISN 04: VA Stars & Stripes Healthcare NetworkSEP 2019CONSOLIDATIONXR RAD646 PITTSBURGH, PA
693B79081VISN 04: VA Stars & Stripes Healthcare NetworkSEP 2019CONSOLIDATIONXR CATH LAB693 WILKES-BARRE, PA
512B91006VISN 05: VA Capitol Health Care NetworkSEP 2019CONSOLIDATIONNM SPECT512 BALTIMORE, MD
540B90203VISN 05: VA Capitol Health Care NetworkSEP 2019CONSOLIDATIONNM PET CT540 CLARKSBURG, WV
558B70017VISN 06: VA Mid-Atlantic Health Care NetworkSEP 2019CONSOLIDATIONXR HYBRID558 DURHAM, NC
508B92021VISN 07: VA Southeast Health Care NetworkSEP 2019CONSOLIDATIONXR CT508 DECATUR, GA
508B92027VISN 07: VA Southeast Health Care NetworkSEP 2019CONSOLIDATIONNM SPECT508 DECATUR, GA
521B92017VISN 07: VA Southeast Health Care NetworkSEP 2019CONSOLIDATIONXR CT521 BIRMINGHAM, AL
521B92026VISN 07: VA Southeast Health Care NetworkSEP 2019CONSOLIDATIONXR RAD521 BIRMINGHAM, AL
521B92029VISN 07: VA Southeast Health Care NetworkSEP 2019CONSOLIDATIONNM SPECT521 BIRMINGHAM, AL
521B92030VISN 07: VA Southeast Health Care NetworkSEP 2019CONSOLIDATIONXR RAD521 BIRMINGHAM, AL
521B92032VISN 07: VA Southeast Health Care NetworkSEP 2019CONSOLIDATIONNM SPECT521 Birmingham, AL
521B92033VISN 07: VA Southeast Health Care NetworkSEP 2019CONSOLIDATIONXR RF521 BIRMINGHAM, AL
521B92034VISN 07: VA Southeast Health Care NetworkSEP 2019CONSOLIDATIONXR RF521 BIRMINGHAM, AL
534B92026VISN 07: VA Southeast Health Care NetworkSEP 2019CONSOLIDATIONXR CATH LAB534 CHARLESTON, SC
534B92034VISN 07: VA Southeast Health Care NetworkSEP 2019CONSOLIDATIONXR MRI534 CHARLESTON, SC
534B92036VISN 07: VA Southeast Health Care NetworkSEP 2019CONSOLIDATIONNM PET CT534 CHARLESTON, SC
534B92037VISN 07: VA Southeast Health Care NetworkSEP 2019CONSOLIDATIONXR CT534 CHARLESTON, SC
534B92038VISN 07: VA Southeast Health Care NetworkSEP 2019CONSOLIDATIONXR CT534 CHARLESTON, SC
534B92039VISN 07: VA Southeast Health Care NetworkSEP 2019CONSOLIDATIONXR RAD534 CHARLESTON, SC
534B92040VISN 07: VA Southeast Health Care NetworkSEP 2019CONSOLIDATIONXR RAD534 CHARLESTON, SC
534B92042VISN 07: VA Southeast Health Care NetworkSEP 2019CONSOLIDATIONXR RAD534 CHARLESTON, SC
534B92043VISN 07: VA Southeast Health Care NetworkSEP 2019CONSOLIDATIONXR RAD534 CHARLESTON, SC
534B92044VISN 07: VA Southeast Health Care NetworkSEP 2019CONSOLIDATIONXR MRI534 CHARLESTON, SC
544B92035VISN 07: VA Southeast Health Care NetworkSEP 2019CONSOLIDATIONXR CT544 COLUMBIA, SC
544B92036VISN 07: VA Southeast Health Care NetworkSEP 2019CONSOLIDATIONXR CATH LAB544 COLUMBIA, SC
619B92002VISN 07: VA Southeast Health Care NetworkSEP 2019CONSOLIDATIONXR CT619 MONTGOMERY, AL
619B92003VISN 07: VA Southeast Health Care NetworkSEP 2019CONSOLIDATIONXR RF619 MONTGOMERY, AL
546B90016VISN 08: VA Sunshine Healthcare NetworkSEP 2019CONSOLIDATIONRT LINAC546 MIAMI, FL
603B93051VISN 09: VA Mid South Healthcare NetworkSEP 2019CONSOLIDATIONXR MRI603 LOUISVILLE, KY
626B90130VISN 09: VA Mid South Healthcare NetworkSEP 2019CONSOLIDATIONXR MRI626 NASHVILLE, TN
506B90079VISN 10: VA Healthcare System of OhioSEP 2019CONSOLIDATIONNM SPECT506 ANN ARBOR, MI
538B90025VISN 10: VA Healthcare System of OhioSEP 2019CONSOLIDATIONNM SPECT538 CHILLICOTHE, OH
538B90030VISN 10: VA Healthcare System of OhioSEP 2019CONSOLIDATIONNM SPECT538 CHILLICOTHE, OH
541B90005VISN 10: VA Healthcare System of OhioSEP 2019CONSOLIDATIONRT LINAC541 CLEVELAND, OH
541B93002VISN 10: VA Healthcare System of OhioSEP 2019CONSOLIDATIONXR MAMMO541 CLEVELAND, OH
541B93007VISN 10: VA Healthcare System of OhioSEP 2019CONSOLIDATIONXR RAD541 CLEVELAND, OH
541B93008VISN 10: VA Healthcare System of OhioSEP 2019CONSOLIDATIONXR CATH LAB541 CLEVELAND, OH
541B93027VISN 10: VA Healthcare System of OhioSEP 2019CONSOLIDATIONXR MAMMO541 CLEVELAND, OH
541B93037VISN 10: VA Healthcare System of OhioSEP 2019CONSOLIDATIONXR MAMMO541 CLEVELAND, OH
541B93041VISN 10: VA Healthcare System of OhioSEP 2019CONSOLIDATIONNM SPECT CT541 CLEVELAND, OH
553B90045VISN 10: VA Healthcare System of OhioSEP 2018CONSOLIDATIONXR RAD553 DETROIT, MI
553B90054VISN 10: VA Healthcare System of OhioSEP 2019CONSOLIDATIONXR CT553 DETROIT, MI
583B90015VISN 10: VA Healthcare System of OhioSEP 2019CONSOLIDATIONXR CT583 INDIANAPOLIS, IN
583B90024VISN 10: VA Healthcare System of OhioSEP 2019CONSOLIDATIONNM SPECT CT583 INDIANAPOLIS, IN
583B90025VISN 10: VA Healthcare System of OhioSEP 2019CONSOLIDATIONNM PET CT583 INDIANAPOLIS, IN
583B90026VISN 10: VA Healthcare System of OhioSEP 2019CONSOLIDATIONNM PET CT583 INDIANAPOLIS, IN
610B94049VISN 10: VA Healthcare System of OhioSEP 2019CONSOLIDATIONXR RAD610 MARION, IN
610B94050VISN 10: VA Healthcare System of OhioSEP 2019CONSOLIDATIONNM SPECT610 MARION, IN
610B95052VISN 10: VA Healthcare System of OhioSEP 2019CONSOLIDATIONNM SPECT610 MARION, IN
537B98020VISN 12: VA Great Lakes Health Care SystemSEP 2019CONSOLIDATIONXR RAD537 CHICAGO, IL
537B98021VISN 12: VA Great Lakes Health Care SystemSep 2019CONSOLIDATIONXR RF537 CHICAGO, IL
550B90036VISN 12: VA Great Lakes Health Care SystemSEP 2019CONSOLIDATIONXR RF550 DANVILLE, IL
550B90037VISN 12: VA Great Lakes Health Care SystemSEP 2019CONSOLIDATIONXR RAD550 DANVILLE, IL
556B68228VISN 12: VA Great Lakes Health Care SystemSEP 2019CONSOLIDATIONXR MRI556 NORTH CHICAGO,IL
556B93709VISN 12: VA Great Lakes Health Care SystemSEP 2019CONSOLIDATIONXR RAD556 NORTH CHICAGO,IL
556B93716VISN 12: VA Great Lakes Health Care SystemSEP 2019CONSOLIDATIONNM SPECT556 NORTH CHICAGO,IL
556B93717VISN 12: VA Great Lakes Health Care SystemSEP 2019CONSOLIDATIONXR RAD556 NORTH CHICAGO,IL
556B93718VISN 12: VA Great Lakes Health Care SystemSEP 2019CONSOLIDATIONXR RAD556 NORTH CHICAGO,IL
578B78022VISN 12: VA Great Lakes Health Care SystemSEP 2019CONSOLIDATIONXR CT578 HINES, IL
578B98056VISN 12: VA Great Lakes Health Care SystemSEP 2019CONSOLIDATIONXR RF578 HINES, IL
578B98059VISN 12: VA Great Lakes Health Care SystemSEP 2019CONSOLIDATIONXR RAD578 HINES, IL
578B98074VISN 12: VA Great Lakes Health Care SystemSEP 2019CONSOLIDATIONXR MRI578 HINES, IL
578B98075VISN 12: VA Great Lakes Health Care SystemSEP 2019CONSOLIDATIONRT LINAC578 HINES, IL
695B98040VISN 12: VA Great Lakes Health Care SystemSEP 2019CONSOLIDATIONXR RAD695 MILWAUKEE, WI
695B98049VISN 12: VA Great Lakes Health Care SystemSEP 2019CONSOLIDATIONXR HYBRID695 MILWAUKEE, WI
657B93016VISN 15: VA Heartland NetworkSEP 2019CONSOLIDATIONXR CT657 POPLAR BLUFF, MO
657B93017VISN 15: VA Heartland NetworkSEP 2019CONSOLIDATIONXR RAD657 POPLAR BLUFF, MO
580B90013VISN 16: South Central VA Health Care NetworkSEP 2019CONSOLIDATIONRT LINAC580 HOUSTON, TX
580B90014VISN 16: South Central VA Health Care NetworkSEP 2019CONSOLIDATIONRT LINAC580 HOUSTON, TX
504B97003VISN 17: VA Heart of Texas Health Care NetworkSEP 2019CONSOLIDATIONXR MRI504 AMARILLO, TX
504B97004VISN 17: VA Heart of Texas Health Care NetworkSEP 2019CONSOLIDATIONXR CT504 AMARILLO, TX
504B97010VISN 17: VA Heart of Texas Health Care NetworkSEP 2019CONSOLIDATIONXR RAD504 AMARILLO, TX
674B90376VISN 17: VA Heart of Texas Health Care NetworkSEP 2019CONSOLIDATIONXR RAD674 TEMPLE, TX
674B90377VISN 17: VA Heart of Texas Health Care NetworkSEP 2019CONSOLIDATIONXR RAD674 TEMPLE, TX
756B95050VISN 17: VA Heart of Texas Health Care NetworkSEP 2019CONSOLIDATIONXR RF756 EL PASO, TX
442B90025VISN 19: VA Rocky Mountain NetworkSEP 2019CONSOLIDATIONXR RAD442 CHEYENNE, WY
442B90026VISN 19: VA Rocky Mountain NetworkSEP 2019CONSOLIDATIONXR RF442 CHEYENNE, WY
442B90027VISN 19: VA Rocky Mountain NetworkSEP 2019CONSOLIDATIONXR CT442 CHEYENNE, WY
635B90011VISN 19: VA Rocky Mountain NetworkSEP 2019CONSOLIDATIONXR RAD635 OKLAHOMA CITY, O
635B90013VISN 19: VA Rocky Mountain NetworkSEP 2019CONSOLIDATIONXR RAD635 OKLAHOMA CITY, O
666B90040VISN 19: VA Rocky Mountain NetworkSEP 2019CONSOLIDATIONXR CT666 SHERIDAN, WY
648B98030VISN 20: VA Northwest NetworkSEP 2019CONSOLIDATIONXR RF648 PORTLAND, OR
648B98083VISN 20: VA Northwest NetworkSEP 2019CONSOLIDATIONXR CATH LAB648 PORTLAND, OR
663B90043VISN 20: VA Northwest NetworkSEP 2019CONSOLIDATIONXR CATH LAB663 SEATTLE, WA
663B90044VISN 20: VA Northwest NetworkSEP 2019CONSOLIDATIONXR CATH LAB663 SEATTLE, WA
692B92008VISN 20: VA Northwest NetworkSEP 2019CONSOLIDATIONXR RF692 WHITE CITY, OR
612B96008VISN 21: VA Sierra Pacific NetworkSEP 2019CONSOLIDATIONXR CT612 REDDING, CA
612B96009VISN 21: VA Sierra Pacific NetworkSEP 2019CONSOLIDATIONXR RF612 REDDING, CA
605B90005VISN 22: VA Desert Pacific Healthcare NetworkSEP 2019CONSOLIDATIONNM SPECT CT605 LOMA LINDA, CA
605B90006VISN 22: VA Desert Pacific Healthcare NetworkSEP 2019CONSOLIDATIONNM SPECT CT605 LOMA LINDA, CA
605B90007VISN 22: VA Desert Pacific Healthcare NetworkSEP 2019CONSOLIDATIONNM PET CT605 LOMA LINDA, CA
664B90009VISN 22: VA Desert Pacific Healthcare NetworkSEP 2019CONSOLIDATIONXR CATH LAB664 SAN DIEGO, CA
664B90012VISN 22: VA Desert Pacific Healthcare NetworkSEP 2019CONSOLIDATIONXR RF664 SAN DIEGO, CA
664B90013VISN 22: VA Desert Pacific Healthcare NetworkSEP 2019CONSOLIDATIONXR RAD664 SAN DIEGO, CA
664B90014VISN 22: VA Desert Pacific Healthcare NetworkSEP 2019CONSOLIDATIONXR RAD664 SAN DIEGO, CA
664B90015VISN 22: VA Desert Pacific Healthcare NetworkSEP 2019CONSOLIDATIONXR RF664 SAN DIEGO, CA
618B99005VISN 23: VA Midwest Health Care NetworkSEP 2019CONSOLIDATIONXR RAD618 MINNEAPOLIS, MN
618B99006VISN 23: VA Midwest Health Care NetworkSEP 2019CONSOLIDATIONXR RAD618 MINNEAPOLIS, MN
636B94051VISN 23: VA Midwest Health Care NetworkSEP 2019CONSOLIDATIONXR RAD636 IOWA CITY, IA
636B94052VISN 23: VA Midwest Health Care NetworkSEP 2019CONSOLIDATIONXR MAMMO636 IOWA CITY, IA

Questions and Answers

Requisition NumberQUESTIONSANSWERS
N/AIn both Team A & Team B Instructions to Offerors the Attention line in the address is the same. Can you please confirm that if we are responding to both Team A & Team B opportunities that we should have 2 separate CDs. Can they be mailed together and just reference Sept 2019 Consolidation or do we need to mail separately and reference Team A or B in the Attention line?Please submit two CDs, one for each team consolidation. Include the following: Team A - Iliana Jorge and Team B - Michael Kuchyak
N/AIn Section 2.0 Offers, 2.8, in the Information folder it requests the Federal Information Processing Standard (FIPS) 140-2 certification. How imperative is it that this certification is included at this time with the consolidation bid? We do not have a FIPS 140-2 certification for RT LINAC or any other sub-systems in the solution. Acquiring this certification could take up to a year plus investments.This requirement is only for use of wireless functionality. This requirement does not apply if equipment does not use wireless technology.
N/A•Is the FIPS 140-2 Certification required for LINAC submissions? It was not a requirement of the BPA.FIPS 140-2 is a requirement for any wireless communication between medical device and VA network
N/AThe Generic benchmarks take a lot more time than the Vendor benchmarks and many will require additional work once the questions are answered. Once the questions are answered, we may need to revise the quote, the vendor matrix and the vendor spreadsheet for each line that has a question. Given the current timeline, we really need at least four weeks from the time the questions are answered and to when final offers are due to the NAC. GE Healthcare is requesting a Due date extension, for the September 2019 Consolidation Team A, to January 29. The extension will allow time to properly answer the generic benchmarks and respond with a compliant offer after vendor questions have been answered.Consolidation schedule has been updated and uploaded. Deadline for Vendor to submit quotes to NAC has been moved to 1/22/2020.
N/APlease provide guidance on how we should respond to generic benchmarks when the answer to a question may change the original matrix. Will you provide a new Matrix or should we note the change in our comments?Benchmark quotes do not require a compliance matrix responses. Technical Specifications will required a compliance matrix to be part of the response and if questions change the technical specifications updated technical specifications and corresponding compliance matrix will be provided in the amendment.
N/AConfirming that for Team A Consolidation Bid that the Compliance Matrix Spreadsheets are not required/applicable as stated in Section 4.4.1. Compliance Matrix SpreadsheetsCompliance matrix spreadsheets are required for those requirements utilizing technical specifications in leu of benchmark quotes.
N/AOn beta.sam.gov website it says Offer Due Date is Jan 14, 2020 but on Consolidation – Team A instructions it says Jan 15, 2020. Which is correct date/time?Consolidation schedule has been updated and uploaded. Deadline for Vendor to submit quotes to NAC has been moved to 1/22/2020.
N/A•The LINAC category is missing from the response folder structure, should we add it or use another one?
Please add it.
N/A•When responding with an alternate to the specifications requested, can we schedule time to present the alternate offering to the requestor?Presentations during technical evaluations are scheduled by the station and contracting if needed. If one vendor is allowed a presentation during technical evaluation then all vendors that bid on that item are allowed the same opportunity.
402B91001System configuration

1.a Fixed Wall Digital Detector, 1.b. Fixed Digital Detector, 1.c. Wireless digital detector Question: Please clarify When the wall stand and/or table detectors can be used as fixed or wireless do you still require a third wireless detector?

2.j. Minimum table height from floor [in] Question: Please change this requirement to 20 inches to allow for fair competition.

Workstation Requirements 4.b. LCD touchscreen acquisition workstation monitor Question: Please expand this requirement to touchscreen or mouse control to allow for fair competition.

Trade-In

Question: Please provide the following information to determine an accurate trade-in value: Manufacture date, year of installation, and projected deinstall date.1a. Yes, we do need a wireless detector. 2J. We agree with minimum table height of inches. 4b. No, Togus needs a touchscreen operator console. Trade in: MFR date 2008, Installation date 2009, projected de-install date 2021
402B91001• Maximum table patient weight of 550 lbs is minimum requirement. Believe this should be minimum table patient weight of 550 lbs.Max table weight should be 550lbs or greater.
402B91002Unit Physical Specifications

1.g. Minimum SID range Question: Please change the minimum requirement 45 in.

Additional Specifications 2.o. Table and upright auto tracking package Question: Please change this minimum requirement to just Auto Tracking package.

2.s. Automatic tube crane, protocol-based movement Question: Please expand to automatic movement on the overhead suspension or fluoro tube.

2.x. Ability to send images directly from the control panel (no separate workstation required) Question: Please define “control panel” – is this requirement for the operator’s console?

2.aa. Auto tracking of the tube and detector during vertical adjustment at the wall stand and/or tube Question: Please remove this requirement to allow for fair competition

2.bb. Tilt-able detector holder with inherent grid (-20 degrees to 90 degrees) Question: Please remove this requirement to allow for fair competition.

2.ee. LCE In Room Monitor Ceiling Mounted Question: Please remove this as a minimum requirement or make it optional

Table Requirements 2.jj. Articulation Question: Please clarify this requirement.

2.rr. Ability to lower tabletop heights to at least 18” from the floor Question: Please change this requirement to a minimum of 18.5” from the floor to allow for full competition.

Software Requirements 3.a. Monitoring Dosage….reproducible with <2% deviation.

Question: In order to allow for full competition please change this requirement to 5% deviation.

Security/Connectivity Requirements 4.c. Encrypted hard drive

Question: Please expand this requirement to include a hard drive that is protected.1g. No, Togus needs industry standards minimum of 40in. 2o. Ok, Togus concurs with Auto tracking package. 2s. Please quote as option. 2x. Yes, we want to send images directly from the operators console. 2aa. No, Togus requires this feature. 2bb. Togus agrees to change requirement to 0 to 90 degrees. 2ee. Please quote as option. 2jj. Togus concurs to remove requirement. 2rr. Yes, we concur to the change.
402B91003Advanced Applications

7.m Integration to third party Advanced Visualization System Question: Please clarify this specification and define “integration.”

7.n. Mobile Trailer Requirements Question: Please clarify this specification:

•Is this for an interim solution? If so, how many months should be accounted for?
•Is a mobile van required for the full system? If yes, please include the specifications and should we include

Trade-In Question: Please provide the following information to determine an accurate trade-in value: Software Level, List of Coils and Channels, Software Level, Year of Installation, and Projected De-Installation date. 7m. We need as a destination in DICOM section.

7n. Yes, it is for a interim solution, no more than 4 months. Yes, as an option not a requirement. Year of Manufacture: I don’t have the date of manufacture, but the startup date was 24-May-2010.

Gradient Strength: X, Y & Z 33Mt/m | Minimum Rise Time 330 µs | Slew Rate 100 T/m/s | Max Gradient Current 625 A | Maximum Voltage 1200 V

Channel count on System: 18

Quench History: I am not seeing any quenches in the service history.

Helium Level: 62.0 % this morning.

Coils: Please see list from inventory below:

Component nameComponent IDSerial number
1.5T 4 Ch Flex large MR coil10142094282384
1.5T 4 Ch Flex Small MR coil10142094342387
1.5T 4 Ch Interface10142094522390
Coil Shoulder Array, large10138897568058
Coil Shoulder Array, small10138897557600
CP Extremity MR Coil103650701730106
Head Matrix MR Coil10142091795035
Neck Matrix MR Coil10142112944995
PA Matrix MR Coil10119860363228
Spine Matrix MR Coil10113531074591 Project de-installation date- TBD
442B90025• 800 lb table patient weight is excessive. The probability of even using a table with an 800 lb patient is low. Suggest lowering the spec to 650 lbs and allowing vendors to stated they exceed the minimum requirement with whatever weight their table holds.

• “Minimal footprint” – Suggest removal. Spec is too general. The requirement to have a typical drawing will allow the site to determine what footprint works best for them.

• “Grids and grid caps in various foci and radius”. The responses to this requirement will be very hard to evaluate “apples to apples”, as vendor A may provide 10 grid and grid cap combinations while vendor B may only provide 2 combinations, which will result in the value proposition not being evaluated equally.

• 24 inch acquisition workstation minimum requirement is unduly restrictive and overly specific. Request lowering to 20” and allowing those who exceed the spec to respond as such.1. Will lower the specification to 650lbs. 2. Will remove "minimal footprint". That must have not been deleted before sending out. 3. Will specify grid requirement to 72” 13:1 ratio, 57” 10:1 ratio and 40” 13:1 ratio wall stand grids (3); 14x17in 6:1 ratio wireless detector grid (1); 40’ 12:1 ratio grid (1) 4. Will move acquisition monitor size to 20" but keeping processing workstation at 24".
442B90026Unit physical specifications

1.a. Minimum wall detector size 17x17in Question: The 17x17 detector is an unduly restrictive requirement. Industry standard for systems with the same clinical requirements is a minimum of a 14x17 inches. Please change the minimum requirement to 14x17 inches.

2.r. Table and upright auto tracking package Question: Please change this minimum requirement to just Auto Tracking package.

2.v. Automatic tube crane, protocol-based movement Question: Please change this requirement to Automatic tube crane, protocol-based movement with fluoro tube.

2.ee. Automated movement for long axis stitching Question: Please change this requirement to Automated movement for long axis stitching at the table.

2.ff. Auto tracking of the tube and detector during vertical adjustment at the wall stand and/or tube.

Question: Please change this requirement to Auto tracking of the tube and detector during vertical adjustment at the table.

2.bbb. Ability to lower tabletop height to at least 18” from the floor in the horizontal position at stated maximum weight capacity.

Question: Please change the minimum specification from 18’ from the floor to 18.5” from the floor.

Software Requirements 3.a. Monitoring of dose…reproducible with <2% deviation Question: Please change the <2% deviation to a 5% deviation to allow for full and open competition.

3.b. Bone Suppression

Question: Please remove the Bone Suppression from the minimum specifications to allow for full and open competition.1.a. Per my research on ECRI most vendors can meet this requirement. A 17x17in detector is preferred as it covers a larger imaging area. 2.r. Will change specification to "Auto Tracking Package" 2.v. Will change specification to clarify 2.ee. Will change specification to clarify 2.ff. Will change specification to clarify 2.bbb. Will change to 18.5", most vendors can meet an 18.5" requirement. 3.a. Will change to 5% or less.To support VHA Directive 1105.04 we prefer as little deviation as possible. 3.b. Will remove bone suppression.
442B90027Unit physical specifications

1.j. Maximum system weight 2,090kg

Question: Please clarify if the Maximum system weight of 2,090kg is for the gantry only or gantry and table? If the spec is for the gantry and table please change this specification to 2,500kg.1.j. This specification is for the gantry and table. I will clarify that in the specifications and change the specification to 2,500.
504B97003Unit physical specifications

1.b Minimum bore width 74cm Question: The minimum 74cm bore requirement is restrictive requirement, please change the minimum specification to 70cm to allow for full and open competition.

1.c. Minimum bore depth 160cm.

Question: The minimum 160cm bore depth requirement is restrictive requirement, please change the minimum specification to 145cm to allow for full and open competition.

1.e. Minimum slew rate 32 T/m/s Question: The minimum 32 T/m/s seems to be an error. Please change this requirement to a minimum slew rate of 200 to allow for full and open competition.

1.f. Minimum number of channels 550 lbs.

Question: The minimum 550lbs requirement seems to be an error. Please confirm that the minimum channel requirement should be 32 channels?

1.h. Minimum UPS time at full functionality is 5700 lbs.

Question: The Maximum Patient Weight Requirement seems to be an error. Please change this requirement to full or partial UPS. If you are requesting a full UPS (ability to scan patients without power) please confirm that the facility has the room, the correct HVAC and power to install this unit.

1.g. Maximum Patient weight withstood 120s Question: The Maximum Patient Weight Requirement seems to be an error. Please change this requirement to 500lbs to allow for full and open competition?

Additional Specifications 2.z. Uninterruptible power supply Question: Please clarify this requirement to full or partial UPS. If you are requesting a full UPS (ability to scan patients without power) please confirm that the facility has the room, the correct HVAC and power to install this unit. 1.b - changed to 70cm 1.c.- changed to 145cm 1.e.-changed to 200 1.f - changed to 32 1.g - changed to 500 lbs 1.h - changed to partial UPS 2.z. - partial UPS required

504B97003 Section B 1 E. Minimum slew rate? Need a number?

H. Minimum UPS time at full functionality [s] Is this for computer software only or entire system including gantry?

Section B 2

d. Uninterruptible power supply Is this for computer software only or entire system including gantry?

z. Uninterruptible power supply Is this for computer software only or entire system including gantry?

Section B 3 Workstation Requirements -What is the workflow and requirements for the workstation?

d. Uninterruptible power supply Is this for computer software only or entire system including gantry?

z. Uninterruptible power supply Is this for computer software only or entire system including gantry? 1.e.-changed to 200 1.h - changed to partial UPS B2.d - Partial system UPS 2.z. - partial UPS required B3.

d. - partial system UPS

z. - partial system UPS

504B97004Provide correct MatrixMatrix provided
504B97004Please provide an updated excel version of the generic benchmark. The wrong document was attached

Technical Requirements 1.b Minimum gantry aperture 75cm Question: The minimum 75cm gantry aperture is restrictive requirement, please change the minimum specification to 70cm to allow for full and open competition.

1.f. Maximum patient weight supported 250kg.

Question: The minimum 250kg patient weight supported is restrictive requirement, please change the minimum specification to 226kg (500lbs) to allow for full and open competition.

1.h. Maximum system weight is 250kg Question: The maximum system weigh of 250kg is restrictive requirement, please change the minimum specification to 2877kg for gantry only and table weight of 800 kg to allow for full and open competition.

Additional Specifications 2.c Dual Energy Imaging (either at the radiation source or in the detector).

Question: Please clarify this request for all vendors. Is a value-based specification desired (e.g., rotate-rotate) or would the VA like to see a premium-level option quoted (e.g., rapid switching).

Advanced Applications 4a.-e. Advanced applications integration to Tera Recon Question: The specification is requesting one post processing workstation, but then requests integration into TeraRecon. Please confirm that the request is for vendors to provide their own OEM advanced applications software for 4a. – 4.d. and then to confirm integration of the CT system (not the workstation) with TeraRecon? 1.b - changed to 70 cm 1.f - changed to 226 kg 1.h - spec removed 2c. - Dual Energy was moved to the value add section of the revised tech specs 4a-e - Both are required. Need a post processing workstation included and also need integration with TeraRecon

504B970041.In Section B-2, item j., the ask is for gantry mounted injector or ceiling mounted. We can supply either, so which one is preferred?
2.In Section B-3, the ask is for a Workstation, but in B-4 item e., the ask is for integration into TeraRecon, which is a workstation. So my question is, do they need a postprocessing workstation included or are they planning to purchase one from TeraRecon?
3.In Section B-2, item c., the ask is for Dual Energy Imaging? Do they want a Dual Imaging Scanner or would they like it in included as an option?B2 j - Pedestal mounted - spec has been updated

B3 - Both are required. Need a post processing workstation included and also need integration with TeraRecon B2- c - Dual Energy was moved to the value add section.

504B970104.d. LCD touchscreen monitor acquisition workstation monitor
Question: Please remove the word, touchscreen, from the workstation monitor description to allow for full competition.We have clinical/technical justification for this and multiple vendors can meet for this specification, therefore it will remain as is.
504B97010• Is maximum detector weight being evaluated with or without the detector battery. If the evaluation is being done with the detector battery, request increasing the minimum requirement to 10 lbs and letting those that exceed the spec state as such.

• Maximum pixel size of the detector is unduly restriction and clinically inconsequential. Request the minimum requirement be increased to 140 microns and allow vendors to exceed the minimum with whatever micron size they have.

• 24 inch acquisition workstation minimum requirement is unduly restrictive and overly specific. Request lowering to 20” and allowing those who exceed the spec to respond as such.updated tech spec
508B92027The spreadsheet has identified this opportunity as a SPECT/CT, however the benchmark quote is a SPECT only camera. Please confirm that the benchmark is the system the customer would like.Schedule of line items changed to reflect SPECT
512B91006Provide MatrixMatrix provided
512B91006Vendor Matrix was not in the SAMS posting please provide

1.d. Minimum Requirement 15.74 x 3.94cm Question: Some cardiac specific camera’s measure the field of view as spherical volume of interest (VOI) instead of a rectangular field of view. Please change the minimum requirement to 15.74 x 3.94cm (UFOV) or 19cm (VOI) to allow for full competition.

1.f. Minimum Workstation monitor Size 24 in Question: To allow for competition please change the minimum requirement to 23” 1.h. Maximum system dimensions (cm) 216cm x 173cm x190cm Question: Please change this specification to must fit in a specific room size. The dimensions above seem to be for a specific vendor.

1.i. Maximum System Weight 670kg Question: Please change the Maximum System weight to 1000kg to allow for full competition 1.j. Maximum Patient Weight 246kg Question: Please change the Maximum Patient Weight to 200kg (440lb) to allow for full and open competition

Additional Specifications 2.f. Open Gantry Question: Please change this requirement to Open or Ring Gantry to allow for full and open competition 2.g. Variable patient position (Upright to supine) Question: Please change this requirement to Variable Patient Position, Supine, Prone, or Dextra-cardia Imaging. While upright imaging is valid the ability to do supine and prone is clinically more relevant in its ability to identify diaphragmatic attenuation.

3.b. Minimum Workstation monitor Size 24 in Question: To allow for competition please change the minimum requirement to 23” Matrix provided 1.d - Specification has been removed.

1.f - Specification changed to 23 inches 1.h - Measurements of room added to the spec 1.i - Specification changed to Maximum floor loading 2.f - We have clinical justification for this and therefore this specification will remain as is.

2.g - We have clinical justification for this and therefore this specification will remain as is.

3.b - Specification changed to 23 inches

521B92026Confirm no trade inYes Trade In - GE Discovery XR650, Serial # 1024364WK0
521B92032The naming convention is incorrect, can this be fixed?NM SPECT is the naming convention used by the NAC for SPECT, Nuclear Medicine and DSPECT systems.
521B92033Confirm no trade inYes Trade In - Philips EasyDiagnost Eleva, Serial # 453387
521B92034Confirm no trade inYes Trade In - Siemens Axiom Sireskop SD, Serial # 400184070
523B91005Additional Specifications

2.d. Removeable lead curtains with counter weights for when curtains not in use Question: To allow for full and open competition please change this requirement to Removable lead curtains with counter weights for when the curtains are not in use or portable radiation shield.

2.s. Head holder device for prone position Question: Please remove this requirement as this seems to be a unique offering from a specific vendor.

Software Requirements

3. a. Monitoring of Dosage- The system must be able to supply a technology that allows for monitoring and tracking of radiation dose provided to a patient; DICOM structured reporting is preferred. DAP accuracy must be 99% reproducible with <2% deviation.

Question: Please change this specification to <5% deviation to allow for full competition.

Security/Connectivity Requirements 4.d. Encrypted hard drive Question: Please expand this requirement to include a hard drive that this protected.

Trade-In

Question: Please provide the following information to determine an accurate trade-in value: Manufacture date, year of installation, and projected deinstall date.2.d., 2.s., and 3.a.- please see attached updated Technical Specs 4.d. This is a national VA requirement. Trade-In: Manufacturer date: 2013, year of installation: 2013, projected deinstall date: ~Dec. 2020
534B92026Technical Requirements

1.d. Minimum image reconstruction rate – 5 second acquisition to yield results in 20 seconds Questions: In order to allow for full competition, please change this minimum requirement to, the system is capable of fast rotational imaging that minimizes breathing artifact

1.h. Minimal rotation rate 45 degrees Question: In order to allow for full competition, please change this minimum requirement to, the minimum rotation rate is capable of fast cone beam CT acquisition to minimize artifact

Additional Specifications 2.ff. MedRad Ceiling mounted contract injector and interface Question: Most interventional suites use a table mounted injector. Please clarify what is requested.

2.ii. Intravascular Ultrasound system (IVUS) Question: Please clarify, do you want the IVUS to display on a large display monitor? 1d. Updating wording to 5 second acquisition. Rate can be met by multiple vendors.

1h. Updating wording to 30 degrees 2ff. Updating to remove ceiling/table specification and allow vendors to bid best option for table proposed.

2ii. Yes, would like monitor to be able to toggle views to display IVUS when it is in use.

534B92034 Technical Requirements 1.f. Minimum number of channels (coil elements) 204 Question: The industry standards is to measure the number of channels, not a vendor specific requirement of coil elements. Please change this specification to 16 channels.

1.g. Maximum Patient weight withstood 550 lbs.

Question: In order to allow for full competition, please change this specification to Maximum Patient Weight withstood 500 lbs. 1f. Updating to 32 channels. (Coil elements per application will be viewed on a value added basis).

1g. Clinical need, multiple vendors can meet requirement.

534B92036 Technical Requirements 1.d. Minimum gantry 30 degrees Question: Tilting gantries are an element in CT, but not PET/CT. Please remove this minimum requirement.

1.m. Minimum time of flight resolution 375 ps.

Question: The time of flight specification of 375 ps., is a restrictive requirement please change this requirement to 385 ps., to allow for full and open competition.

1.n. Minimum time of flight coincidence window 4.5ns.

Question: The time of flight specification of 4.5ns., is a restrictive requirement, please change this requirement to 5.25 ns, to allow for full and open competition.

1.s. Workstation operating system, Win 10 or above at time of delivery Question: Not all systems have a Windows Operating system, please change this requirement to Win 10, Linux or above at time of delivery. 1d. Removing requirement.

1m. Updating to 385 ps 1n. Updating to 4.9 ns 1s. Updating to Windows 10 or above, Linux equivalent generation or above, or other unique operating system of equivalent generation or above at time of delivery.

534B92037 Technical Requirements 1.a. Minimum number of slices 64 Question: Please confirm requirement that the CT must have a minimum of 64 independent detector rows?

1.j. Workstation Operating System Win10 or above at time of delivery.

Question: To allow for full and open competition, please change this requirement to Win10 (or above) or Linux Operating System at time of delivery Additional Specifications 2.r. 3D visualization and processing capabilities for reading Question: Please confirm that vendors should include independent 3d workstation capable of post processing 3D CT data? 1a. Confirmed as a 64.

1j. Updating to Windows 10 or above, Linux equivalent generation or above, or other unique operating system of equivalent generation or above at time of delivery.

2r. 3D post-processing is required, either on a independent workstation or included on primary workstation is acceptable.

534B92038 Technical Requirements 1.a. Minimum number of slices 64 Question: Please confirm requirement that the CT must have a minimum of 64 independent detector rows?

1.j. Workstation Operating System Win10 or above at time of delivery.

Question: To allow for full and open competition, please change this requirement to Win10 (or above) or Linux Operating System at time of delivery Additional Specifications 2.r. 3D visualization and processing capabilities for reading Question: Please confirm that vendors should include independent 3d workstation capable of post processing 3D CT data? 1a. Confirmed as a 64.

1j. Updating to Windows 10 or above, Linux equivalent generation or above, or other unique operating system of equivalent generation or above at time of delivery.

2r. 3D post-processing is required, either on a independent workstation or included on primary workstation is acceptable.

534B92039, 534B92040, 534B92042, 534B92043 Additional Specifications 2.b. Ability to accept multipower feeds from 110v to 440v Question: Please change this requirement to 3 phase, 480 volts to accommodate modern XR power requirements.

2.c. Floor mount tube with bucky tracking for wall stand Question: Section 1.n. identifies this requirement as a ceiling mounted system. Please remove, “Floor Mount” to the 2.c specification. 2b. Updated to ability to accommodate multi-phase, 480V 2c. Updated to remove floor mount

534B92039, 534B92040, 534B92042, 534B92043• The spec requests a standard table patient weight limit of 500 lbs, then a maximum bariatric table patient weight limit of 750 lbs. Bariatric tables are generally wider than standard tables. Does the site want a bariatric table or a standard table? Is the weight limit a dynamic or static?
• 1 TB workstation minimum requirement for workstations is unduly restrictive. Request the minimum requirement be lowered to 250GB and then those vendors with larger hard drives can state they exceed the minimum.- Two x-ray rooms going into each CBOC site. Requirements are the same for the two rooms, with the exception of one room having a standard table and one room having a bariatric table. Please quote a standard table for B92039 and B92042 and a bariatric table for B92040 and B92043.

- This requirement is specific to the acquisition workstation that stores images. 250GB is insufficient for clinic need. Requirement will remain at 1 TB of hard drive space and requirement added of 16 GB of RAM.

534B92044 Technical Requirements 1.f. Minimum number of channels (coil elements) 204 Question: The industry standards is to measure the number of channels, not a vendor specific requirement of coil elements. Please change this specification to 64 channels.

1.g. Maximum Patient weight withstood 550 lbs.

Question: In order to allow for full competition, please change this specification to Maximum Patient Weight withstood 500 lbs. 1f. Updating to 32 channels. (Coil elements per application will be viewed on a value added basis).

1g. Clinical need, multiple vendors can meet requirement.

537B98020Confirm no trade inPresent equipment should be traded in: GE Definium 8000 with table and wall stand
541B93002, 541B93027, 541B93037Please confirm that VA Cleveland is asking for three Mammography Systems and one biopsy device? We understood the customer wanted two systems and one biopsy device.Cleveland VA is requesting three Mammography Systems, 541B93002, 541B93027 and 541B93037. With requisition 541B93037 there is a requirement to include a biopsy device.
549B90568Listed in pre-solicitation list but were not included in the Solicitation list. Please confirm that it was removed.This is part of Team B
550B90036Confirm no trade inConfirmed no trade-in
550B90037need more information for the system being traded in. The only information provided is the name of the system, Phillips Optimus.
At minimum we would need an Install year, Serial number and any other information they can provide.The Philips Diagnost digital X-ray system was installed January of 2011, has SN of 00003D/C34911, and includes wall bucky, transparent grid, polydoros tube, touchscreen central console, and Eleva software
556B68228Provide MatrixMatrix provided
556B68228Is missing the vendor matrix spreadsheet from the information sent from the NAC. Can you please provide?Matrix provided
556B68228Please provide the excel version of this generic specification.

1.j. Maximum System Weight 12,000 lbs.

Question: In order to allow full competition please change this requirement to 17,000 lbs. or allow vendors to quote an extended installation proposal that may include additional structural support.

Trade-In Question: Please provide the following information to determine an accurate trade-in value: Software Level, List of Coils and Channels, Software Level, Year of Installation, and Projected De-Installation date. 1.j. We cannot raise the weight limit above 12,000 pounds. We also do not want the floor modified to provide structural support.

Trade In information:

Software version: 6.1V5 Release 3.2.3.5 Coil list:

1 8 channel Head 1 XL 16 channel Torso coil 1 15 channel Spine 1 16 channel NV coil 1 8 channel wrist coil 1 16 channel TR Knee coil 1 8 channel foot ankle coil 1 8 channel knee coil 1 6 channel CTL coil 1 6 channel cardiac coil 1 intera torso coil 1 6 channel breast coil 1 2 channel TR head coil 1 Sense flex large coil 1 Sense flex medium coil

556B68228missing the vendor matrix spreadsheet from the information sent from the NAC. Can you please provide?Matrix provided
556B93709Confirm no trade inThere should be a trade in: PHILIPS ESSENTA DR S/N: 9000020 Acquired APR 24,2009
556B93717Confirm no trade inThere should be a trade in: Siemens Multix MT S.N: 10220 Acquired 4-Nov-2011
556B93718Confirm no trade inThere should be a trade in: Siemens Multix MT S.N: 10221 Acquired 4-Nov-2011
558B70017Item 43 EPIQ7 Ci Integration Kit – This item is only available from one vendor and is unduly restrictive. Please remove this from the minimum requirements.

Item 49 CVX-300 Excimer Laser System – This item is only available from one vendor and is unduly restrictive. Please remove this from the minimum requirements. Item 43: integration kit is required to connect the cardiac ultrasound and the echo interventional navigation tool for fusing live X-ray and live echo. Anatomical intelligence fusion imaging must be able to fuse live 3D transesophageal echo (TEE) and live X-ray in real time so care-giver can intuitively guide the device in the 3D space quickly. (facility will accept "removal of "model name")

Item 49: Excimer laser system and disposable catheters for the treatment of peripheral and coronary arterial disease. Photoablation is the use of light to break down, vaporize and remove matter. The excimer laser system facilitates photoablation via a variety of laser catheters to remove binding arterial plaques. (facility will accept "removal of "model name") 561B82013 • Wireless cardiac gating Question: To allow fair competition please remove this specification and permit all cardiac gating devices.

•32 Ch vs 16 Ch
Question: Both a 16 and 32 Ch system are referenced in the benchmarked quotation. What is the minimum system channel requirement?Ok to remove “wireless”

Minimum 32 channel 578B78022 Technical Requirements 1.d. Maximum Patient Weight Supported 295kg Question: Please clarify the maximum weight required, if the linear accelerator weight maximum is 227kg/500lb should this requirement be the same.

Additional Specifications 2.a. The CT scanner shall provide the ability for the user to independently operate the table, gantry and CT Fluoroscopy mode from the control room.

Question: Please clarify with the customer that CT Fluro is required or should be removed.

2.b. Modeled iterative reconstruction/Noise reduction. Vendors are encouraged to propose the greatest available noise reduction.

Question: Please clarify that the iterative reconstruction is a requirement. We understood that they customer does not plan to use this system for diagnostic CT and would, therefore, not utilize iterative reconstruction.

2.d. Full UPS Question: Please clarity this requirement, a full system UPS is very large and may not fit in the room. Does the customer want a full system UPS that will allow the facility to continue to scan if power is lost or a partial system UPS that will keep the scanner on and allow the therapist to get the patient off the table and save the data, but not continue scanning?

2.g. Wall or table mounted patient respiratory gating camera Question: Please update this specification to Wall mounted, Table mounted or Deviceless patient respiratory gating.

Question – We did not see Metal Artifact Reduction on the Generic Quote. Please ask this customer if this should be added to the minimum specifications 1.d. 500 lbs. is acceptable 2.a. CT Flouro should be included.

2.b. Iterative reconstruction should be included.

2.d. Provide a partial system UPS.

2.g. Metal artifact reduction should be included.

578B98056labeled XR RAD. Confirm this is actually an RF System.Corrected modality to RF
578B98056Confirm no trade inPresent equipment should be traded in - Philips MultiDiagnost Eleva (SN: 41445017)
578B98059Confirm no trade inPresent equipment should be traded in - 2 GE Definiums 8000s (SNs: 09210078 & 59623HL9)
595B99012We would like to request that Agfa be given the opportunity for an on-site presentation for VAMC Lebanon and Pittsburgh following the closing date of January 15, 2020.
Please advise if there is a Project Manager for each one of these projects that we could contact for an in person discussion or if you will communicate this request to the appropriate parties.No onsite presentations are allowed at this time in the solicitation
595B99012System Configuration

1.a Fixed Wall Digital Detector, 1.b. Fixed Digital Detector, 1.c. Wireless digital detector Question: Please clarify When the wall stand and/or table detectors can be used as fixed or wireless do you still require a third wireless detector?

Unit physical specifications 2.h. Maximum 2nd wireless detector [in x in] Question: Please change this requirement to 17inx17in to allow for fair competition.

2.m. Minimum tube height from floor when used with wall stand [in] Question: Depending on confirmation of type of tube mount please increase to 15.7 inches if Floor-Mounted tube or 11 inches if ceiling suspend tube.

2.n. Minimum image plate height from floor [in] Question: Depending on confirmation of type of tube mount please increase to 15.7 inches if Floor-Mounted tube or 11 inches if ceiling suspend tube.

Additional Specifications 3.n. Tube Mount: Floor-Mounted Question: Other specifications for this obligation would lean toward a ceiling suspended tube. Please confirm that a floor-mounted tube mount is indeed the requirement.

Workstation Requirements 4.d. LCD touchscreen monitor acquisition workstation monitor Question: Please remove the word, touchscreen, from the workstation monitor description to allow for full competition. 1.a. Only two detectors are required if the wall stand or table detectors can be used as fixed or wireless.

2.h. Changed in tech specs.

2.m. Changed in tech specs

2.n Changed in tech specs.

3.n Change to ceiling mount in tech specs.

4.d. Removed touchscreen. Changed in tech specs

595B99012• “Maximum 2nd Wireless detector size” of 16”x16” is unduly restriction. Most vendors other than GE make a 14”x17” wireless detector or a 17”x17” wireless detector. Request max 2nd detector size be changed to a more standard 14”x17” minimum specification and let vendors exceed the minimum.
• Minimum specs state minimum patient weight of 550 lbs, but additional specifications state the table has to be bariatric. Does this indicate the customer wants a bariatric table or a standard table with a minimum patient weight of 550 lbs? Bariatric tables usually have a much higher weight limit and are wider. Please clarify.Changed the specs for 2nd detector to 14”x17”

Either would be fine. As long as the table holds a minimum of 550lbs.

595B99012Requirement N states the tube mount should be floor mounted. Is that accurate? It seems like they want full functionality (dual energy, etc.), which can be done, but not as efficiently as with an OTC.Changed to ceiling mounted per previous information.
603B93051Is there a trade? If so we need information on it for accurate pricingWe will be trading in Philips 1.5T Achieva MR system S/N 32384
603B93051Is there a trade? If so we need information on it for accurate pricingWe will be trading in Philips 1.5T Achieva MR system S/N 32384
608B93006System Configuration

1.a Fixed Wall Digital Detector, 1.b.