335-00016 Sterilizer Brand Name or Equal.pdf

PDF 106 KB Posted

Attached to
Sterilizer - Parlier, CA
Solicitation number
12905B24Q0253
Issued by

About this file

This document is a Combined Synopsis/Solicitation for a commercial item - a sterilizer unit (autoclave) for the Insectary at the San Joaquin Valley Agricultural Sciences Center in Parlier, California. The solicitation is a Request for Quotation (RFQ) with a required delivery date of November 27, 2024. The product specifications call for a 20" x 20" x 38" chamber, single door sterilizer that is freestanding. This is a Total Small Business Set-Aside under NAICS code 339113 with an 800 employee size standard. Offers are due by 12:00 pm Central Time on August 21, 2024 and should be submitted to the email address provided. Questions regarding the solicitation must be submitted in writing by 12:00 pm Central Time on August 19, 2024. The Federal Agency issuing this solicitation is the Department of Agriculture, Agricultural Research Service, Pacific West Area.

View the file

Other files

File Type Posted
12905B24Q0253.pdf PDF
24Q0253 - Combined Syn-SOL - Description Notice - Supply.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Brand Name or Equal

The Commodity Protection and Quality research unit needs a sterilization unit (autoclave) for the Insectary. Through market research we identified Consolidated Sterilizer System that meets our requirements. Use the specifications below to provide a brand name or equal ICP-MS System to continue our research at the San Joaquin Valley Agricultural Sciences Center in Parlier, California.

Specifications for Insectary Sterilization Unit

1. Features CSS 3AV: 20” X 20” x 38” chamber single door sterilizer

• The system should be freestanding and occupy a footprint of >20”and <27”

• X1 Controls: Top Mount 7" Color Touchscreen, up to 50 programmable cycles SteriNET Dataport - USB Password Protection (up to 50 users & passwords) and Lockable Cycle Parameters

• Thermal Printer Controls: 110 Volts, 60 Hz (Standard)

• Service access on left side and limited to 6” rear access

• ProGEN Model Integral Electrically Heated Steam Generator - 25 KW

** Generator Voltage & Phase TBD - Please provide at time of order **

• Automatic Generator Blowdown With Motorized Ball Valve

• Hi-Vacuum System with Water Ejector (MINIMUM 45 psi dynamic water required)

Brass, Bronze, and Copper Piping

• EZ-Glide Vertical Sliding Door with Non-Stick Gasket

• Cabinet Mounting with Stainless Steel Front and Side Panels (Standard)

• WaterEco® Water Conservation & Monitoring System

• Automatic Jacket Blowdown for Liquids Cycle

• Bowie Dick Test and Vacuum Leak Test Whisper-Quiet On-Board Air Compressor

(Supplied if house air is not available) Emergency Stop Button

• 2 shelves – 1 stationary

• Service access on left side and limited to 6” rear access

• Emergency Stop Button

2. Standard Features

• EcoCalendar & Auto Idle Shut-Off capability for energy efficient control of steam

• ASME (American Society of Mechanical Engineers) U-1 Code Stamping

• 1/2" Thermocouple Port UL, cUL Listed

• End-of-Cycle Vacuum Drying

• Fully Opening Front Service Panel

• CSS Starter Kit including C3 cleaner and scrubbing pads, a pair of autoclave gloves, printer paper and printer ribbon (if applicable), and electronic manuals

3. Installation

• The system should be delivered with all necessary supplies and accessories required for the installation and start-up. The installation and training must be included.

• Old system should be de-installed and removed.

4. Delivery

USDA ARS

9611 S. Riverbend

Parlier, CA 93648

By 11/27/2024