3138106_QAIRQMT_REPORT.pdf

PDF 82 KB Posted

Attached to
Overhaul of the F100 PW-220/220E #4 Bearing Air Seal NSN: 2840-00-343-7939/PN 4036962
Solicitation number
FA8121-22-R-0007
Issued by

View the file

Other files

File Type Posted
FA812122R0007.pdf PDF
FA812122R0007.pdf PDF
3226725_DID 81838.pdf PDF
Transportation1.pdf PDF
3138132_RDL_REPORT.pdf PDF
3226727_DID 81995A.pdf PDF
3290165_DID 80441D.pdf PDF
3226739_DID 81534A.pdf PDF
3290181_DID 81534A.pdf PDF
3226741_DID 81535A.pdf PDF
3290229_DID 80229D.pdf PDF
3226735_DID 80441D.pdf PDF
3279442_CDRL1_REPORT.pdf PDF
3264504_TRNSPDATA_REPORT.pdf PDF
CDRL DR 21-32578.pdf PDF
FA812122R0007.pdf PDF
3290182_DID 81535A.pdf PDF
CDRL Status Report 21-32578.pdf PDF
3226723_DID 81634C.pdf PDF
3290171_DID 81838.pdf PDF
3138076_QUALRQMT.pdf PDF
3246217_PWS.doc DOC document
3264473_PKGRQMT_REPORT.pdf PDF
Packaging1.pdf PDF
DR DID.pdf PDF
Transportation.pdf PDF
3290173_DID 82128A.pdf PDF
Packaging.pdf PDF
3290169_DID 81634C.pdf PDF
3226736_DID 80229D.pdf PDF
3290225_DID 81995A.pdf PDF
Show all 31

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RECOMMENDED QUALITY ASSURANCE PROVISIONS

AND SPECIAL INSPECTION REQUIREMENTS

1. PR / MIPR NUMBER

2. NATIONAL STOCK NUMBER

2840003437939NZ

3. POINT OF INSPECTION

SOURCE DESTINATION

X

SEE DFARS 246.402

4. POINT OF ACCEPTANCE

SOURCE DESTINATION

X

5. ITEM MANAGER / PHONE

Franzoni, Jacob R / 405-734-5507

6. EQUIPMENT SPEC / PHONE

KOPP, STEPHEN / 405-734-0244

7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS

CERTIFICATE OF CONFORMANCE

FAR 52.246-15

CONTRACT RESPONSIBILITY

FOR INSPECTION

FAR 52.246-1

STANDARD INSPECTION

FAR 52.246-2,-3,-4,-5 OR -6

AS APPLICABLE TO CONTRACT

X HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS

ISO 9001:2000

COMMERCIAL ITEM INSPECTION

FAR 52.212-4

OTHER (Describe in Block 8)

8. REMARKS

Olsson, James DNAME: 20 NOV 2020DATE:

This is a Critical Safety Item (CSI)

Sanor, Dacota RNAME: 02 APR 2019DATE:

HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS

FAR 52-246-11

ISO 9001-2008

8a. OZONE DEPLETING SUBSTANCES (ODS)

X STATEMENT

"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN

ONLY BE MET BY THE USE OF A CLASS I ODS."

WAIVER (SEE AF FARS 5323)

NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.

9. QUALITY PRE-AWARD SURVEY

YES NEW SOURCE

X PREVIOUS SOURCEX NO

AFMC PARTICIPATION

RECOMMENDED

10. CODES

A. I&A

B. CQR

G

11. SIGNATURE OF TECHNICAL AUTHORITY

Olsson, James D

ORGANIZATION / SYMBOL

AFLCMC / LPEA2

PHONE

405-622-7829 / 892-7829

DATE

20 NOV 2020

Page 1 of 1AFMC FORM 807, 20060111, V1 Version 4Generated by PRPS using Jasper Reports on 29 Jul 2021