This is a product specification document for Milwaukee County Mitchell International Airport outlining requirements for the procurement of one new electric micro slim slab scissor lift. The lift must meet minimum performance standards including a 550-pound platform capacity, ability to accommodate two personnel, 25 percent gradeability, and electric proportional drive and control systems. The specification establishes working height requirements of 31 feet minimum for indoor use and 24 feet minimum for outdoor use, with corresponding platform heights of 25 feet and 18 feet respectively. The stowed height cannot exceed 90.3 inches to permit passage through standard commercial doorways. The unit must feature a rollout deck extension with incremental locking positions, a full-height swing gate for safe platform access, and a minimum of two lanyard attachment points. The equipment is intended for delivery FOB destination to 5300 S. Howell Avenue, Milwaukee, Wisconsin, fully assembled and ready for operation.
The specification is performance-based and nonproprietary, permitting any manufacturer's product meeting or exceeding all stated requirements to be considered equivalent. Bidders must submit manufacturer's published specifications, documentation of safety and standards compliance, warranty terms, and standard and optional features being supplied. The unit must include a maintenance-free AGM-type battery system with minimum 240 ampere-hour capacity, automatic onboard charger, proportional controls with removable upper control box, nonmarking tires suitable for indoor use, and comprehensive safety features including emergency stop controls, descent alarm, drive-speed interlock, automatic parking brakes, and laser perimeter lighting. Warranty requirements include a minimum one-year warranty on defective components and five-year warranty on structural components, with battery coverage of not less than 90 days or the manufacturer's standard, whichever is greater. Delivery documentation must include operator's manual, service and maintenance manual, warranty registration information, and all keys and control devices. The maximum machine weight is approximately 4,190 pounds.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 2-Milwaukee County Terms and Conditions.pdf | ||
| 1-Bid Prerequisite Requirements Scissor Lifts.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PRODUCT SPECIFICATIONS
ELECTRIC MICRO SLIM SLAB SCISSOR LIFT (OR EQUIVALENT)
1. GENERAL
1.1 Provide and deliver new electric micro slim slab scissor lifts meeting or exceeding the minimum performance, dimensional, safety, and warranty requirements set forth in this specification.
1.2 Quantity
· Base bid quantity: One (1) electric scissor lift.
· The Owner reserves the right to increase or decrease quantities.
1.3 Application Units shall be suitable for indoor and outdoor use in restricted spaces and building interiors, including operation through standard commercial doorways.
1.4 Non‑restrictive Specification / “Or Equivalent”
· This is a performance‑based, non‑proprietary specification.
· Any manufacturer’s product that meets or exceeds all stated requirements will be considered.
· Any reference in supporting material to a particular configuration is intended only as a standard of quality and performance, not as a brand requirement.
1.5 Bidder Responsibility Bidders shall provide descriptive literature and technical data demonstrating that the proposed unit(s):
· Conform to all minimum requirements in these specifications, and
· Are equivalent in performance, quality, durability, and safety to the standards described herein.
The Owner reserves the right to determine whether any proposed equipment is equal or equivalent.
2. PERFORMANCE AND CAPACITY
2.1 Platform Capacity
· Minimum platform capacity: 550 lb.
2.2 Personnel Rating
· Minimum personnel rating:
· 2 people
2.3 Gradeability
· Minimum gradeability: 25%.
2.4 Drive and Control
· Electric drive system.
· Proportional drive and lift controls for smooth, precise operation.
2.5 Speed Requirements
· Raise/lower speed (approximate, nominal values acceptable):
· Raise: about 30 seconds,
· Lower: about 25 seconds.
· Drive speed:
· Stowed: approximately 3 mph,
· Elevated: approximately 0.5 mph.
3. WORKING HEIGHT AND DIMENSIONS
3.1 Working Heights
· Minimum indoor working height: 31 ft or greater.
· Minimum outdoor working height: 24 ft or greater.
3.2 Platform Heights
· Minimum indoor platform height: 25 ft or greater.
· Minimum outdoor platform height: 18 ft or greater.
3.3 Stowed Height
· Stowed height to top of guardrail shall be no more than 90.3 in to allow passage through standard commercial doorways.
3.4 Platform and Chassis Dimensions
· Maximum overall width: 31.9 in.
· Overall length (stowed): approximately 74 in (shorter acceptable if requirements are met).
· Platform length (retracted): approximately 68 in.
· Platform length (with deck extended): approximately 103.5 in.
· Roll‑out deck extension length: approximately 35.5 in.
· Must include incremental locking positions
· Platform width (outside): approximately 29.1 in.
· Wheelbase: approximately 55 in.
· Ground clearance (stowed): approximately 3 in.
3.5 Guardrails and Toe boards
· Guardrail height: approximately 43.5 in.
· Toe board height: minimum 6 in.
3.6 Machine Weight
· Maximum machine weight: approximately 4,190 lb, or less, while meeting all stated requirements.
4. PLATFORM FEATURES AND MATERIAL HANDLING
4.1 Deck Extension
· Roll‑out deck extension with incremental locking positions.
· Minimum deck extension capacity: 250 lb.
4.2 Access and Tie‑Off
· Full‑height swing gate or equivalent safe access system for entering and exiting the platform.
· Minimum of two (2) lanyard attachment points on the platform.
5. POWER AND ELECTRICAL SYSTEM
5.1 Battery System
· Maintenance‑free battery system with total capacity of approximately 240 Ah or greater.
· AGM Type battery
5.2 Charging System
· Onboard, fully automatic battery charger with voltage‑compensating capability or equivalent.
· Battery charge indicator visible to the operator.
5.3 Control System
· Proportional controls for drive and lift.
· Removable upper control box.
6. SAFETY, STANDARDS, AND PROTECTION
6.1 Standards Compliance Units shall comply with all applicable current aerial work platform standards (e.g., relevant ANSI and CSA standards for mobile elevating work platforms).
6.2 Safety Features (Minimum) Units shall include, at minimum:
· Lift control design to reduce entrapment risk.
· Dedicated compartments that protect electrical and hydraulic components.
· Emergency stop controls at both upper and lower control stations.
· Non‑skid metal platform surfaces.
· Descent alarm.
· Drive-speed interlock
· Automatic parking brakes.
· Automatic pothole protection system.
· Scissor maintenance lock.
· Machine tie‑down provisions for transport.
6.3 Tires
· Non‑marking tires suitable for indoor use.
· Approximate tire size: 12 in × 5 in or equivalent providing similar load support and clearance.
6.4 Additional Safety and Visibility Features The following shall be included as part of the base configuration:
· System designed to contain or control potential hydraulic leaks to protect finished floors or sensitive environments.
· Visual warning device (such as a flashing beacon) to enhance visibility.
· Laser perimeter lighting with toggle switch.
· Motion or travel alarm(s) to indicate movement of the machine.
7. SERVICEABILITY AND MAINTENANCE
7.1 Service Access
· Components shall be arranged to allow convenient maintenance access, including swing‑out or easily opened compartments for major electrical and hydraulic systems.
7.2 Low‑Maintenance Design
· Use of lubrication‑free or low‑maintenance bearings in the scissor stack or equivalent design to minimize routine greasing.
7.3 Parking Brake Release
· Means to manually release parking brakes for controlled movement of a non‑powered machine.
7.4 Monitoring
· Hour meter or equivalent device to record machine usage hours.
8. WARRANTY
8.1 Minimum Warranty Requirements
· Minimum 1‑year warranty on defective components (parts and labor).
· Minimum 5‑year warranty on structural components.
· Battery warranty not less than 90 days or manufacturer’s standard, whichever is greater.
8.2 Warranty Documentation
· Bidders shall include full written warranty terms with the bid submission, clearly identifying coverage, exclusions, and claim procedures.
9. DELIVERY AND COMMISSIONING
9.1 Delivery Terms
· Units shall be delivered FOB destination, fully assembled and ready for operation, to the location designated by the Owner (5300 S. Howell Avenue Milwaukee, WI)
9.2 Condition at Delivery
· Units shall be delivered in ready‑to‑use condition, with all safety systems functional, batteries charged, and pre‑delivery inspection completed by the vendor.
9.3 Documentation on Delivery At the time of delivery, the vendor shall provide:
· Operator’s manual(s).
· Service/maintenance manual(s) or equivalent technical documentation.
· Warranty registration information.
· All keys and control devices.
10. EQUIVALENT PRODUCTS
10.1 Equivalents Allowed
· Any current production model electric micro scissor lift that meets or exceeds all stated requirements in this specification is acceptable.
· No particular brand or model is specified or implied.
10.2 Supporting Documentation To demonstrate equivalency, bidders shall submit:
· Manufacturer’s published specifications (capacity, heights, dimensions, weight).
· Standard and optional features being supplied, clearly identified.
· Safety and standards compliance information.
· Warranty terms meeting or exceeding Section 8.
10.3 Determination of Equivalency the Owner will determine, at its sole discretion, whether a proposed product is equivalent in all material respects to the requirements of this specification.