3 - EPR to trophon2 specs brochure.pdf

PDF 2 MB Posted

Attached to
Trophon Devices: Trophone EPR High Level Disinfection of Ultrasound probes
Solicitation number
IHS1503681
Issued by

About this file

This is a product brochure for the trophon2 ultrasound probe disinfection system by Nanosonics. The document introduces the next generation of their trophon EPR device, which uses sonically activated hydrogen peroxide technology for high-level disinfection of ultrasound probes.

The trophon2 includes several key improvements over the original EPR model: digital audit-ready records with AcuTrace RFID technology, automated compliance tracking, downloadable disinfection reports via USB, adjustable warm-up and sleep timer settings, a new chamber design for curved probes, compatibility with over 1,000 probe types, and an enhanced user interface with a color touchscreen. The system maintains the core benefits of fast disinfection while reducing exposure to toxic chemicals. This document appears to be associated with a pre-solicitation notice from the Navajo Area Indian Health Service seeking to procure trophon units for their Chinle Comprehensive Health Care Facility.

View the file

Other files

File Type Posted
IHS IEE Representation Form.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Introducing trophon®2.

The world’s best just got better.

We’ve taken the EPR and transformed it at every level.

trophon® technology revolutionized high-level disinfection around the world

1. Nanosonics microbial test reports on file.

The launch of trophon2 takes ultrasound probe reprocessing to a new level The trophon family now includes the trophon EPR and trophon2 devices, which share the same core technology of sonically activated hydrogen peroxide.

trophon2 offers an advanced user experience to deliver greater workflow efficiencies and demonstrated compliance.

Going beyond the global requirements for endocavitary and surface probes used in semi-critical and critical procedures, trophon technology has demonstrated microbial efficacy against an extensive range of clinically relevant species.1

Some key highlights of what’s new Demonstrates compliance across the workflow

• Supports digital audit-ready records with AcuTrace® RFID technology

• Printer label and digital records include probe, operator and cycle data

• Download detailed disinfection reports to USB

• RFID enabled workflow, accessories and consumables.

Smart workflow efficiencies

• Daily warm up: Adjustable ‘wake up’ times for each day, so it is ready to start when your day begins

• Sleep timer: Enters power-saving mode when not in use. Adjust in hourly increments or option to turn off

• Purge now or defer feature when disinfectant has reached expiry in the device.

Extensive probe compatibility

• New chamber shape and integrated probe positioner for curved probes

• Approved, endorsed and recommended by ultrasound manufacturers

• Compatible with over 1,000 probes

• Universal Cable Clamp for a wide range of cable diameters.

Enhanced usability

• Easy-close door that automatically seals tight

• Simple to use color touchscreen with animations that navigate you through the disinfection process

• View last cycle disinfection record on screen

• Guided initial software setup and simple access to settings menu.

In 2009, Nanosonics launched the trophon EPR, setting a completely new global standard in the disinfection of ultrasound probes.

trophon was a faster, simpler alternative to the existing disinfection processes, mitigating the risk of exposure to toxic chemicals. It was superior and safer for both patients and health care professionals.

Nanosonics Limited 14 Mars Road, Lane Cove, NSW 2066, Australia T: +61 2 8063 1600 E: info@nanosonics.com.au W: www.nanosonics.com.au

Nanosonics, Inc. (Distributor) 7205 E 87th Street, Indianapolis, IN 46256, USA T: 1-844-TROPHON (1-844-876-7466) E: info@trophon.com W: www.trophon.us © 2020 Nanosonics Limited. All rights reserved. NAN0275. MM01451-USA & CA-BR V2. September 2020.