3. Attach A ACM Test Report.pdf

PDF 1 MB Posted

Attached to
Water Damage Reconstruction at Columbia Basin Job Corps Center
Solicitation number
1282A723Q0051
Issued by

About this file

This document contains two asbestos testing reports and information about a related federal contract opportunity for water damage reconstruction.

The first report details asbestos testing on four samples from a project at Columbia Job Corps and identifies chrysotile asbestos in vinyl floor tiles and mastic. The second report provides results for 24 samples from Columbia Basin Job Corps, finding no asbestos in materials like drywall, cove base, mastic and flooring.

The related solicitation is number 1282A723Q0051 from the Department of Agriculture Forest Service for water damage reconstruction at Columbia Basin Job Corps Center. The opportunity type is a solicitation and no further details are provided on response dates, pricing terms, set asides or other salient information.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SanAir ID#: 23000030

Project #: ML-22-0776 WTR Project Name: Columbia Job Corp Report Date: 1/3/2023

Analysis Report prepared for Just Right Cleaning & Construction, Inc.

Dear Matt Kohl, We at SanAir would like to thank you for the work you recently submitted. The 4 sample(s) were received on Tuesday, January 03, 2023 via UPS. The final report(s) is enclosed for the following sample(s): 01, 02, 03, 04.

These results only pertain to this job and should not be used in the interpretation of any other job. This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.

Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory

Final Report Includes:

- Cover Letter

- Analysis Pages

- Disclaimers and Additional Information

Sample conditions:

- 4 samples in Good condition.

10501 Trade Ct., N. Chesterfield, VA 23236 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

ML-22-0776 WTRProject Number:

P.O. Number:

Project Name: Columbia Job Corp

12/30/2022Collected Date:

1/3/2023 10:05:00 AMReceived Date:

1/3/2023 11:36:50 AM

23000030 SanAir ID Number

FINAL REPORT

Just Right Cleaning & Construction, Inc.Name:

Address: 6446 Rd 3 NE

Moses Lake, WA 98837

509-765-4138Phone:

Analyst: Moore, Brandi

Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers 01 / 23000030-001 Vinyl Tile & Mastic Up Classroom, Tile

Red Non-Fibrous

Homogeneous

96% Other 4% Chrysotile

01 / 23000030-001 Vinyl Tile & Mastic Up Classroom, Mastic

Black Non-Fibrous

Homogeneous

100% Other None Detected

02 / 23000030-002 Vinyl Tile & Mastic Up Classroom, Tile

Red Non-Fibrous

Homogeneous

96% Other 4% Chrysotile

02 / 23000030-002 Vinyl Tile & Mastic Up Classroom, Mastic

Black Non-Fibrous

Homogeneous

100% Other None Detected

03 / 23000030-003 Sheet Vinyl Up Classroom

Off-White Non-Fibrous

Heterogeneous

15% Cellulose 5% Glass

80% Other None Detected

04 / 23000030-004 Sheet Vinyl Up Classroom

Off-White Non-Fibrous

Heterogeneous

15% Cellulose 5% Glass

80% Other None Detected

Analyst:

Analysis Date: 1/3/2023 Date: 1/3/2023

Approved Signatory:

ML-22-0776 WTRProject Number:

P.O. Number:

Project Name: Columbia Job Corp

12/30/2022Collected Date:

1/3/2023 10:05:00 AMReceived Date:

1/3/2023 11:36:50 AM

23000030 SanAir ID Number

FINAL REPORT

Just Right Cleaning & Construction, Inc.Name:

Address: 6446 Rd 3 NE

Moses Lake, WA 98837

Disclaimer

This report is the sole property of the client named on the SanAir Technologies Laboratory chain-of-custody (COC). Results in the report are confidential information intended only for the use by the customer listed on the COC. Neither results nor reports will be discussed with or released to any third party without our client's written permission. The final report shall not be reproduced except in full without written approval of the laboratory to assure that parts of the report are not taken out of context. The information provided in this report applies only to the samples submitted and is relevant only for the date, time, and location of sampling. The accuracy of the results is dependent upon the client’s sampling procedure and information provided to the laboratory by the client. SanAir assumes no responsibility for the sampling procedure and will provide evaluation reports based solely on the sample(s) in the condition in which they arrived at the laboratory and information provided by the client on the COC, such as: project number, project name, collection dates, po number, special instructions, samples collected by, sample numbers, sample identifications, sample type, selected analysis type, flow rate, total volume or area, and start stop times that may affect the validity of the results in this report. Samples were received in good condition unless otherwise noted on the report. SanAir assumes no responsibility or liability for the manner in which the results are used or interpreted. This report does not constitute and shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any other U.S. governmental agencies and may not be certified by every local, state, and federal regulatory agencies.

Samples are held for a period of 60 days. Fibers smaller than 5 microns cannot be seen with this method due to scope limitations.

For NY state samples, method EPA 600/M4-82-020 is performed.

NYELAP Disclaimer:

Polarized- light microscopy is not consistently reliable in detecting asbestos in floor covering and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos containing.

Asbestos Certifications NVLAP lab code 200870-0 City of Philadelphia: ALL-460 PA Department of Environmental Protection Number: 68-05397 California License Number: 2915 Colorado License Number: AL-23143 Connecticut License Number: PH-0105 Massachusetts License Number: AA000222 Maine License Number: LB-0075, LA-0084 New York ELAP lab ID: 11983 Rhode Island License Number: PCM00126, PLM00126, TEM00126 Texas Department of State Health Services License Number: 300440 Commonwealth of Virginia 3333000323 Washington State License Number: C989 West Virginia License Number: LT000616 Vermont License: AL166318 Louisiana Department of Environmental Quality: 212253, Cert 05088

Revision Date: 8/14/2020

Page 1 of 1Page 4 of 5

SanAir ID#: 23000037

Project #: 22-0776 Project Name: Columbia Basin Jog Cores Report Date: 1/3/2023

Analysis Report prepared for Just Right Cleaning & Construction, Inc.

Dear Zake Warian, We at SanAir would like to thank you for the work you recently submitted. The 24 sample(s) were received on Tuesday, January 03, 2023 via UPS. The final report(s) is enclosed for the following sample(s): 001, 002, 003, 004, 005, 006, 007, 008, 009, 010, 011, 012, 013, 014, 015, 016, 017, 018, 019, 020, 021, 022, 023, 024.

These results only pertain to this job and should not be used in the interpretation of any other job. This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.

Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory

Final Report Includes:

- Cover Letter

- Analysis Pages

- Disclaimers and Additional Information

Sample conditions:

- 24 samples in Good condition.

10501 Trade Ct., N. Chesterfield, VA 23236 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

22-0776Project Number:

P.O. Number:

Project Name: Columbia Basin Jog Cores

12/30/2022Collected Date:

1/3/2023 10:05:00 AMReceived Date:

1/3/2023 12:35:31 PM

23000037 SanAir ID Number

FINAL REPORT

Just Right Cleaning & Construction, Inc.Name:

Address: 6446 Rd 3 NE

Moses Lake, WA 98837

Analyst: Pisula, Nicholas

Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers 001 / 23000037-001 Hallway, Base Cove, Cove Base

Green Non-Fibrous

Homogeneous

100% Other None Detected

001 / 23000037-001 Hallway, Base Cove, Mastic

White Non-Fibrous

Homogeneous

100% Other None Detected

002 / 23000037-002 Hallway, Base Cove, Cove Base

Green Non-Fibrous

Homogeneous

100% Other None Detected

002 / 23000037-002 Hallway, Base Cove, Mastic

White Non-Fibrous

Homogeneous

100% Other None Detected

003 / 23000037-003 Hallway, Drywall, Drywall

Grey Non-Fibrous

Homogeneous

5% Cellulose 95% Other None Detected

003 / 23000037-003 Hallway, Drywall, Texture

White Non-Fibrous

Homogeneous

100% Other None Detected

004 / 23000037-004 Hallway, Drywall, Drywall

Grey Non-Fibrous

Homogeneous

5% Cellulose 95% Other None Detected

004 / 23000037-004 Hallway, Drywall, Texture

White Non-Fibrous

Homogeneous

100% Other None Detected

005 / 23000037-005 Classroom 004, Base Cove, Cove Base

Green Non-Fibrous

Homogeneous

100% Other None Detected

005 / 23000037-005 Classroom 004, Base Cove, Mastic

White Non-Fibrous

Homogeneous

100% Other None Detected

Analyst:

Analysis Date: 1/3/2023 Date: 1/3/2023

Approved Signatory:

22-0776Project Number:

P.O. Number:

Project Name: Columbia Basin Jog Cores

12/30/2022Collected Date:

1/3/2023 10:05:00 AMReceived Date:

1/3/2023 12:35:31 PM

23000037 SanAir ID Number

FINAL REPORT

Just Right Cleaning & Construction, Inc.Name:

Address: 6446 Rd 3 NE

Moses Lake, WA 98837

Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers 006 / 23000037-006 Classroom 004, Base Cove, Cove Base

Green Non-Fibrous

Homogeneous

100% Other None Detected

006 / 23000037-006 Classroom 004, Base Cove, Mastic

White Non-Fibrous

Homogeneous

100% Other None Detected

007 / 23000037-007 Classroom 004, Drywall, Drywall

Grey Non-Fibrous

Homogeneous

5% Cellulose 95% Other None Detected

007 / 23000037-007 Classroom 004, Drywall, Texture

White Non-Fibrous

Homogeneous

100% Other None Detected

008 / 23000037-008 Classroom 004, Drywall, Drywall

Grey Non-Fibrous

Homogeneous

5% Cellulose 95% Other None Detected

008 / 23000037-008 Classroom 004, Drywall, Texture

White Non-Fibrous

Homogeneous

100% Other None Detected

009 / 23000037-009 Classroom 003, Base Cove, Cove Base

Green Non-Fibrous

Homogeneous

100% Other None Detected

009 / 23000037-009 Classroom 003, Base Cove, Mastic

White Non-Fibrous

Homogeneous

100% Other None Detected

010 / 23000037-010 Classroom 003, Base Cove, Cove Base

Green Non-Fibrous

Homogeneous

100% Other None Detected

010 / 23000037-010 Classroom 003, Base Cove, Mastic

White Non-Fibrous

Homogeneous

100% Other None Detected

Analyst:

Analysis Date: 1/3/2023 Date: 1/3/2023

Approved Signatory:

10501 Trade Ct., N. Chesterfield, VA 23236 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

22-0776Project Number:

P.O. Number:

Project Name: Columbia Basin Jog Cores

12/30/2022Collected Date:

1/3/2023 10:05:00 AMReceived Date:

1/3/2023 12:35:31 PM

23000037 SanAir ID Number

FINAL REPORT

Just Right Cleaning & Construction, Inc.Name:

Address: 6446 Rd 3 NE

Moses Lake, WA 98837

Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers 011 / 23000037-011 Classroom 003, Drywall, Drywall

Grey Non-Fibrous

Homogeneous

5% Cellulose 95% Other None Detected

011 / 23000037-011 Classroom 003, Drywall, Texture

White Non-Fibrous

Homogeneous

100% Other None Detected

012 / 23000037-012 Classroom 003, Drywall, Drywall

Grey Non-Fibrous

Homogeneous

5% Cellulose 95% Other None Detected

012 / 23000037-012 Classroom 003, Drywall, Texture

White Non-Fibrous

Homogeneous

100% Other None Detected

013 / 23000037-013 Classroom 003, Closet, Base Cove, Cove Base

Green Non-Fibrous

Homogeneous

100% Other None Detected

013 / 23000037-013 Classroom 003, Closet, Base Cove, Mastic

White Non-Fibrous

Homogeneous

100% Other None Detected

014 / 23000037-014 Classroom 003, Closet, Base Cove, Cove Base

Green Non-Fibrous

Homogeneous

100% Other None Detected

014 / 23000037-014 Classroom 003, Closet, Base Cove, Mastic

White Non-Fibrous

Homogeneous

100% Other None Detected

015 / 23000037-015 Classroom 003, Closet, Drywall, Drywall

Grey Non-Fibrous

Homogeneous

5% Cellulose 95% Other None Detected

015 / 23000037-015 Classroom 003, Closet, Drywall, Texture

White Non-Fibrous

Homogeneous

100% Other None Detected

Analyst:

Analysis Date: 1/3/2023 Date: 1/3/2023

Approved Signatory:

10501 Trade Ct., N. Chesterfield, VA 23236 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

22-0776Project Number:

P.O. Number:

Project Name: Columbia Basin Jog Cores

12/30/2022Collected Date:

1/3/2023 10:05:00 AMReceived Date:

1/3/2023 12:35:31 PM

23000037 SanAir ID Number

FINAL REPORT

Just Right Cleaning & Construction, Inc.Name:

Address: 6446 Rd 3 NE

Moses Lake, WA 98837

Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers 016 / 23000037-016 Classroom 003, Closet, Drywall, Drywall

Grey Non-Fibrous

Homogeneous

5% Cellulose 95% Other None Detected

016 / 23000037-016 Classroom 003, Closet, Drywall, Texture

White Non-Fibrous

Homogeneous

100% Other None Detected

017 / 23000037-017 Classroom 002, Base Cove, Cove Base

Black Non-Fibrous

Homogeneous

100% Other None Detected

017 / 23000037-017 Classroom 002, Base Cove, Mastic

White Non-Fibrous

Homogeneous

100% Other None Detected

018 / 23000037-018 Classroom 002, Base Cove, Cove Base

Black Non-Fibrous

Homogeneous

100% Other None Detected

018 / 23000037-018 Classroom 002, Base Cove, Mastic

White Non-Fibrous

Homogeneous

100% Other None Detected

019 / 23000037-019 Classroom 002, Drywall, Drywall

Grey Non-Fibrous

Homogeneous

5% Cellulose 95% Other None Detected

019 / 23000037-019 Classroom 002, Drywall, Texture

White Non-Fibrous

Homogeneous

100% Other None Detected

020 / 23000037-020 Classroom 002, Drywall, Drywall

Grey Non-Fibrous

Homogeneous

5% Cellulose 95% Other None Detected

020 / 23000037-020 Classroom 002, Drywall, Texture

White Non-Fibrous

Homogeneous

100% Other None Detected

Analyst:

Analysis Date: 1/3/2023 Date: 1/3/2023

Approved Signatory:

10501 Trade Ct., N. Chesterfield, VA 23236 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

22-0776Project Number:

P.O. Number:

Project Name: Columbia Basin Jog Cores

12/30/2022Collected Date:

1/3/2023 10:05:00 AMReceived Date:

1/3/2023 12:35:31 PM

23000037 SanAir ID Number

FINAL REPORT

Just Right Cleaning & Construction, Inc.Name:

Address: 6446 Rd 3 NE

Moses Lake, WA 98837

Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers 021 / 23000037-021 Classroom 002, Closet, Base Cove, Cove Base

Black Non-Fibrous

Homogeneous

100% Other None Detected

021 / 23000037-021 Classroom 002, Closet, Base Cove, Mastic

White Non-Fibrous

Homogeneous

100% Other None Detected

022 / 23000037-022 Classroom 002, Closet, Base Cove, Cove Base

Black Non-Fibrous

Homogeneous

100% Other None Detected

022 / 23000037-022 Classroom 002, Closet, Base Cove, Mastic

White Non-Fibrous

Homogeneous

100% Other None Detected

023 / 23000037-023 Classroom 002, Closet, Drywall, Drywall

Grey Non-Fibrous

Homogeneous

5% Cellulose 95% Other None Detected

023 / 23000037-023 Classroom 002, Closet, Drywall, Texture

White Non-Fibrous

Homogeneous

100% Other None Detected

024 / 23000037-024 Classroom 002, Closet, Drywall, Drywall

Grey Non-Fibrous

Homogeneous

5% Cellulose 95% Other None Detected

024 / 23000037-024 Classroom 002, Closet, Drywall, Texture

White Non-Fibrous

Homogeneous

100% Other None Detected

Analyst:

Analysis Date: 1/3/2023 Date: 1/3/2023

Approved Signatory:

10501 Trade Ct., N. Chesterfield, VA 23236 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

22-0776Project Number:

P.O. Number:

Project Name: Columbia Basin Jog Cores

12/30/2022Collected Date:

1/3/2023 10:05:00 AMReceived Date:

1/3/2023 12:35:31 PM

23000037 SanAir ID Number

FINAL REPORT

Just Right Cleaning & Construction, Inc.Name:

Address: 6446 Rd 3 NE

Moses Lake, WA 98837

Disclaimer

This report is the sole property of the client named on the SanAir Technologies Laboratory chain-of-custody (COC). Results in the report are confidential information intended only for the use by the customer listed on the COC. Neither results nor reports will be discussed with or released to any third party without our client's written permission. The final report shall not be reproduced except in full without written approval of the laboratory to assure that parts of the report are not taken out of context. The information provided in this report applies only to the samples submitted and is relevant only for the date, time, and location of sampling. The accuracy of the results is dependent upon the client’s sampling procedure and information provided to the laboratory by the client. SanAir assumes no responsibility for the sampling procedure and will provide evaluation reports based solely on the sample(s) in the condition in which they arrived at the laboratory and information provided by the client on the COC, such as: project number, project name, collection dates, po number, special instructions, samples collected by, sample numbers, sample identifications, sample type, selected analysis type, flow rate, total volume or area, and start stop times that may affect the validity of the results in this report. Samples were received in good condition unless otherwise noted on the report. SanAir assumes no responsibility or liability for the manner in which the results are used or interpreted. This report does not constitute and shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any other U.S. governmental agencies and may not be certified by every local, state, and federal regulatory agencies.

Samples are held for a period of 60 days. Fibers smaller than 5 microns cannot be seen with this method due to scope limitations.

For NY state samples, method EPA 600/M4-82-020 is performed.

NYELAP Disclaimer:

Polarized- light microscopy is not consistently reliable in detecting asbestos in floor covering and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos containing.

Asbestos Certifications NVLAP lab code 200870-0 City of Philadelphia: ALL-460 PA Department of Environmental Protection Number: 68-05397 California License Number: 2915 Colorado License Number: AL-23143 Connecticut License Number: PH-0105 Massachusetts License Number: AA000222 Maine License Number: LB-0075, LA-0084 New York ELAP lab ID: 11983 Rhode Island License Number: PCM00126, PLM00126, TEM00126 Texas Department of State Health Services License Number: 300440 Commonwealth of Virginia 3333000323 Washington State License Number: C989 West Virginia License Number: LT000616 Vermont License: AL166318 Louisiana Department of Environmental Quality: 212253, Cert 05088

Revision Date: 8/14/2020

Page 1 of 1Page 8 of 10

23000030_Columbia Job Corp_202313114513
23000037_Columbia Basin Jog Cores_202313124354

File details come from the government source that posted it. Updated .