3-Crestview 2026.xlsx
XLSX spreadsheet 9 KB Posted
- Attached to
- Data Cable RFP - Crestview Middle School
- Solicitation number
- 26-13102
- Issued by
- Missouri
About this file
Crestview Location Data Summary
This file is a location data specification document for the Rockwood School District's Data Cable RFP for Crestview Middle School in Missouri. The project encompasses the installation of Cat6a drops, IDF (Intermediate Distribution Frame) racks and cabinets, and a fiber campus backbone across multiple school buildings. The infrastructure design includes 12 IDFs distributed across various campus locations: MDF A serving as the head end with 48 switch modules in wall configuration and 12 modules in cabinet configuration; IDF B through IDF K each housing between 6 and 24 switch modules depending on location and purpose. The document specifies 86 classrooms requiring 344 total data drops, with an additional 83 data points designated for specific operational areas such as the cafeteria, gymnasium facilities, pool area, administrative offices, and support spaces, totaling 408 drops across the campus. Specific termination requirements are detailed for each IDF, with several closets designated for fiber-only infrastructure containing no new copper connections.
The specification document provides detailed drop counts and IDF assignments for individual rooms and functional areas throughout the facility. Notable allocations include the Cafeteria requiring 12 drops via IDF D, gymnasium facilities requiring multiple drops via IDF E (4 drops in Main Gym, 2 in Lower Gym, with additional drops in Weight Rooms and Locker Rooms), administrative spaces including Office, Reception, Nurse, and Guidance areas requiring drops via IDF A, and specialized areas such as the Pool, Library, and Theatre with specified drop requirements. The document serves as an equipment and infrastructure inventory that supports the bidding process for qualified contractors to provide comprehensive data communications infrastructure improvements to Crestview Middle School.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 6-26-13102 Addendum 1.pdf | ||
| 1-Acknowledgement Form.pdf | ||
| 5-26-13102 Addendum 1.pdf | ||
| 4-Appendix B.pdf | ||
| 2-Appendix A - Parts List - E-Rate 2026.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1 Crestview Location
| Data Closet | 11 IDF's | 12 | ||
| MDF A (300s) (Wall) | 48 SM | |||
| MDF A (300s) (Cabinet) | 12 | Terminate in MDF A (Wall) | ||
| IDF B (UL 200s) | 6 SM | Terminate in MDF A, J | ||
| IDF C (LL 100s) | 6 SM | Terminate in MDF A, J | ||
| IDF D (CAFE) | 24 SM | Terminate in MDF A, J | ||
| IDF E (PE OFFICE) | 24 SM | Terminate in MDF A, J | ||
| IDF F (North Building) | 6 SM | Fiber Only | No New Copper Should Terminate in this Closet | Terminate in IDF E,A, or J |
| IDF G (Rm318) | 6 SM | Fiber Only | No New Copper Should Terminate in this Closet | Terminate in MDF A, J |
| IDF H (Office) | 6 SM | Fiber Only | No New Copper Should Terminate in this Closet | Terminate in MDF A, J |
| IDF I (Rm515) | 6 SM | Fiber Only | No New Copper Should Terminate in this Closet | Terminate in IDF E,A, or J |
| IDF J (DR/SERVER) MDF | Head End | Fiber Only | No New Copper Should Terminate in this Closet | |
| IDF K (Library) | 6 SM | Fiber Only | No New Copper Should Terminate in this Closet | Terminate in MDF A, J |
| Appendix B; Classroom (86) DATA (344) | 83 | 332 | 408 | |||
| Room # | Feet | Drops | AP | FxSwitch | ||
| 101 | IDF C | 4 | ||||
| 102 | IDF C | 4 | ||||
| 103 | IDF C | 4 | ||||
| 104 | IDF C | 4 | ||||
| 105 | IDF C | 4 | ||||
| 106 | IDF C | 4 | ||||
| 107 | IDF C | 4 | ||||
| 108 | IDF C | 4 | ||||
| 109 | IDF C | 4 | ||||
| 110 | IDF C | 4 | ||||
| 111 | IDF C | 4 | ||||
| 112 | IDF C | 4 | ||||
| 113 | IDF C | 4 | ||||
| 114 | IDF C | 4 | ||||
| 114 (switches) | IDF C | 4 | ||||
| 200 | IDF B | 4 | ||||
| 201 | IDF B | 4 | ||||
| 202 | IDF B | 4 | ||||
| 203 | IDF B | 4 | ||||
| 204 | IDF B | 4 | ||||
| 205 | IDF B | 4 | ||||
| 206 | IDF B | 4 | ||||
| 207 | IDF B | 4 | ||||
| 208 | IDF B | 4 | ||||
| 209 | IDF B | 4 | ||||
| 210 | IDF B | 4 | ||||
| 211 | IDF B | 4 | ||||
| 212 | IDF B | 4 | ||||
| 213 | IDF B | 4 | ||||
| 214 | IDF B | 4 | ||||
| 301 | IDF A | 4 | ||||
| 302 | IDF A | 4 | ||||
| 303 | IDF A | 4 | ||||
| 304 | IDF A | 4 | ||||
| 305 | IDF A | 4 | ||||
| 306 | IDF A | 4 | ||||
| 307 | IDF A | 4 | ||||
| 308 | IDF A | 4 | ||||
| 309 | IDF A | 4 | ||||
| 310 | IDF A | 4 | ||||
| 312 | IDF A | 4 | ||||
| 313 | IDF A | 4 | ||||
| 314 | IDF A | 4 | ||||
| 315 | IDF A | 4 | ||||
| 316 | IDF A | 4 | ||||
| 317 | IDF A | 4 | ||||
| 318 | IDF A | 4 | ||||
| 318 (IDF) | IDF A | 4 | Run 4 Drops into the Data Cabinet) | |||
| 319 | IDF A | 4 | ||||
| 320 | IDF A | 4 | ||||
| 321 | IDF A | 4 | ||||
| 322 | IDF A | 4 | ||||
| 331 | IDF A | 4 | ||||
| 401 | IDF D | 4 | ||||
| 402 | IDF D | 4 | ||||
| 403 | IDF D | 4 | ||||
| 404 | IDF D | 4 | ||||
| 405 | IDF D | 4 | ||||
| 406 | IDF D | 4 | ||||
| 407 | IDF D | 4 | ||||
| 408 | IDF D | 4 | ||||
| 410 | IDF D | 4 | ||||
| 411 | IDF D | 4 | ||||
| 412 | IDF D | 4 | ||||
| 413 | IDF D | 4 | ||||
| 414 | IDF D | 4 | ||||
| 415 | IDF D | 4 | ||||
| 416 | IDF D | 4 | ||||
| 417 | IDF D | 4 | ||||
| 418 | IDF D | 4 | ||||
| 419 | IDF D | 4 | ||||
| 501 | IDF E | 4 | ||||
| 508 | IDF E | 4 | ||||
| 507 | IDF E | 4 | ||||
| 506 | IDF E | 4 | ||||
| 505 | IDF E | 4 | ||||
| 509 | IDF E | 4 | ||||
| 510 | IDF E | 4 | ||||
| 511 | IDF E | 4 | ||||
| 512 | IDF E | 4 | ||||
| 513 | IDF E | 4 | ||||
| 514 | IDF E | 4 | ||||
| 515 | IDF E | 4 |
| Appendix C; Specific Copper Data Drops | 76 | ||
| Cafeteria | IDF D | 12 | 2@AP, 2@AP, 8@Cafe Registers |
| Cafe Office | IDF D | 4 | 4 In office |
| Custodian Office | IDF D | 2 | 2 In office |
| Theatre | IDF B | 3 | 1 each side of stage plus on wall |
| MAIN GYM | IDF E | 4 | 2@AP, 2@AP (Each Corner) |
| Lower GYM | IDF E | 2 | 2@AP |
| Weight Room | IDF E | 2 | 2@AP |
| Weight Room | IDF E | 2 | 2 Near door |
| Boys Locker Room | IDF E | 6 | 2 at each desk |
| Girls Locker Room | IDF E | 6 | 2 at Each desk |
| Pool | IDF E | 3 | 2@AP 1@DESK |
| Office | IDF A | 4 | 2@AP, 2 to DeskPC Reception |
| Nurse | IDF A | 2 | 2@AP |
| 325 | MDF A | 2 | 2 @ AP |
| 116 | IDF C | 2 | 2@AP |
| 117 | IDF C | 2 | 2@AP |
| 115 | IDF C | 2 | 2@AP |
| 323 | MDF A | 8 | Building Tech Office |
| Guidance Office | 4 | 2 In celing, 2 in wall for outside AP | |
| Pool Pump Room | 2 | 2 at Pool Pump Controller | |
| Library | 2 | 2@AP |
File details come from the government source that posted it. Updated .