The document is a detailed technical drawing set for fence and gate details, specifically Attachment B, which provides a 6-foot chain link fence detail. The drawing is part of a larger set of site details for a project, created by Stantec, a professional services firm. The technical drawing includes comprehensive specifications for a 6-foot chain link fence, showing precise measurements, materials, and construction methods.
The chain link fence detail specifies a 6-foot tall fence with vertical posts at corners and gates, featuring a vertical barbed wire line post arm. The fence includes top and brace rails, with 9ga ties and a 3/8" truss rod with tightener. The fence is anchored into a concrete sub strip with 36-inch deep concrete footings. Additional details include galvanized tension wire, specific post dimensions (3" corner posts), and precise installation guidelines for different fence components. The drawing provides a comprehensive cross-section and elevation view, ensuring clear instructions for precise fence construction.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 4-25-197-B Attachment C Zone Map.pdf | ||
| 2-25-197-B Bid Pricing Form.xlsx | XLSX spreadsheet | |
| 1-25-197-B Solicitation Packet 205-08-27.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment B
6 Foot Chain Link Fence Detail:
FLAG POLE DETAIL
PLAN VIEW
ELEVATION
GATE STOP DETAIL
TYPICAL ELEVATION OF GATE/SCREEN WALL
2'-0" DIA
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
Copyright Reserved
ORIGINAL SHEET - ARCH E1
Revision By Appd YYYY.MM.DD
Issued By Appd YYYY.MM.DD
Drawing No.Revision
Project No.
Title
Scale
Client/Project
Client/Project Logo
Permit/Seal
Consultant
Notes
ATS AH
/8
/2
: 3 :5
P
M
As indicated
P ic k lo c a ti o n in P ro je c t
In fo rm a ti o n
Stantec Architecture Inc.
6080 Tennyson Parkway Suite 200
Plano, 75024-6003
Tel: (214) 473-2400 • www.stantec.com
401 E. BROWN STREET
WYLIE, TX 75098
SITE DETAILS
214000865
ISSUED FOR BID, PERMIT, CONSTRUCTION
AS005
NTMWD
MULTIPLE SYSTEMS MAINTENANCE FACILITIES
CENTRAL REGION, PHASE II
2021.09.07
C4 DECORATIVE GATE DETAILS
C3 DECORATIVE FENCE DETAILS
A5 FLAG POLE DETAIL
A3 GATE STOP DETAIL
A1 AS51_SITE_GATE_SWING
C2 SPLASH BLOCK DETAIL
2 ADDENDUM #2 ATS AH 2021.09.29
5 ADDENDUM #5 ATS AH 2021.10.31
D1 CHAINLINK FENCE & GATE DETAILS
D5 MOW STRIP DETAIL
C1 PIPE BOLLARD DETAIL
cmetz Line cmetz Line cmetz Line cmetz Line
| 25-197-B Attachment B |
| 20-086-B Fence Map.pdf |
| Gates H Brace |
| L. Gate and Stretch Post Cut Sheet |
| L. Fence Detail Specs |
| L. 6 Ft Wood |
| L. 8 ft Wood |
| L. Chain Link 2 |
| Attachment B |
| Pages from MSMFCR_Phase_II-Conformed_Const_Set (3) |
File details come from the government source that posted it. Updated .