ENGINEERING DATA LIST

DATE:

06 FEB 2020

REVISION: 12 *HISTORY*

CAGE:

77445

PAGE:

NSN:

2840015042791NZ

DATA TECH:

Jones, Kenneth R

END ITEM:

F100/200/220 ENGINE

ORGANIZATION/OFFICE SYMBOL:

429 SCMS GUMAC/

MANUFACTURER NAME:

RAYTHEON TECHNOLOGIES CORPORATION

REFERENCE NUMBER:

4086297

NOUN:

DUCT,TURBINE,AIRCRA

LINE/

SUB CAGE

ENG DRAWING NUM/ ACCOMP

DOC NUM REV

NR

SHEETS

FURN

CODE

DIST

CODE NOUN REMARKS

L 77445 4086297 A 0000 S SUPPORT ASSY

L 77445 QAD4086297 0000 S QUALITY ASSURANCE DATA

L 77445 4086296 B 0000 S SUPPORT

L 77445 QAD4086296 0000 S QUALITY ASSURANCE DATA

L 77445 4072926 C 0000 S PIN

L 77445 QAD4072926 B 0000 S QUALITY ASSURANCE DATA

L 77445 FPMCODE2 B 0000 S FPI

L 77445 FPS-M U 0000 S FPI

L 77445 PWA97 P 0000 S FINISH SPEC.

L 77445 PWA119 M 0000 S FINISH

L 77445 PWA310 BG 0000 S IDENTIFICATION MARKING

L 77445 PWA322 F 0000 S FLOW

L 77445 PWA360 U 0000 S DRAWING INTERPRETATION

L 77445 PWA361 D 0000 S STAKE

L 77445 PWA362 P 0000 S SURFACE TEXTURE

L 77445 PWA367 R 0000 S ENGNRG PROCESSES

L 77445 PWA370 U 0000 S ENGNG PROCESSES

APPROVAL

L 77445 PWA397 J 0000 S CLASSIFICATION CLASS

L 77445 PWA1198 G 0000 S NI ALLOY

L 77445 VIS-MASTER K 0000 S VISUAL INSPECTION

L 00000 AMS5707 0000 O NI ALLOY

L 00000 AS478 O PART MARKING

L 00000 MIL-STD-130 0000 O PART MARKING

STANDARD ENGINEERING TEXT

Jones, Kenneth R 06 FEB 2020

RELEASE OF THIS DATA TO A FOREIGN-OWNED, CONTROLLED OR INFLUENCED COMPANY IS DEPENDENT UPON THE APPROVAL OF THE FOREIGN DISCLOSURE OFFICE.THE CONTRACTOR SHALL USE THE MOST CURRENT AMENDMENTS APPLICABLE TO EACH MIL SPEC,MIL STD,INDUSTRY SPEC OR INDUSTRY STD AS OF THE EFFECTIVE DATE OF THIS CONTRACT UNLESS OTHERWISE NOTED.

NAME: DATE:

C - CLASSIFIED DOCUMENT.

S - FURNISHED WITH SOLICITATION.

M - STABLE BASE DRAWING REQUIRED; FURNISHED WITH

CONTRACT AWARD.

X - DATA SUPPLIED (NOT IN JEDMICS).

R - FURNISHED BY PCO UPON REQUEST.

P - PARTIAL DOCUMENT FURNISHED.

V - VENDOR DRAWING; (NOT PROVIDED).

G - GOV'T DOCUMENT.

O - OTHERS, CONTRACTOR MUST ACQUIRE.

A- DATA NOT AVAILABLE.

FURNISHED METHOD CODE LEGEND:

Page 1 of 1EDL Version 12Generated by PRPS using Jasper Reports on 15 Jul 2022