This construction document set, prepared by the Iowa Department of Natural Resources (DNR) Engineering Section, details the plans and specifications for the Lower Equestrian Campground Pit Latrine project at Shimek State Forest in Lee County, Iowa (Project No. 27-06-56-01). The project scope includes demolition of existing pit latrines, installation of a prefabricated modular restroom building (Iowa Wood Duck model manufactured by HuffCutt Concrete Inc.), construction of a new ADA-compliant paved parking stall with reinforced concrete, minor grading, and site restoration with seeding. Key work items include mobilization, removal and disposal of existing facilities with coordination of vault pumping, placement of 6-inch reinforced Portland cement concrete (PCC) pavement on granular subbase with a maximum 1.8% slope, yellow pavement markings, installation of a 15-minute parking sign, and parking bumper installation. The bid closing date is October 1, 2026, at 3:00 PM, with electronic submission required. Contractors are required to visit the project site prior to bidding to verify actual site conditions, dimensions, and elevations, and to familiarize themselves with existing underground utilities and facilities.

The plans specify that all work shall conform to applicable codes and ordinances, with the contractor responsible for identifying and avoiding damage to existing utilities and for providing disposal sites for excess excavated material and broken concrete. The contractor must manage erosion control features including silt fencing, seeding, and silt basins throughout construction. Site conditions show proximity to existing stables and require maximization of distance from existing trees. The project is supervised by the Iowa DNR with Morgan Nordyke as Project Manager and Bruce Flippin as Engineering Bureau Chief. Professional engineer Michael D. Dufoe, License No. 17753, prepared these construction documents with a license renewal date of December 31, 2027. No pricing information, funding sources, or set-aside provisions are detailed within this plans document.

View the file

Other files

File Type Posted
27-06-56-01 - Bid Package.pdf PDF
27-06-56-01 - Addendum No 1.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Michael D. Dufoe Date License Number: 17753 My license renewal date is December 31, 2027 Pages or sheets covered by this seal:

All

Capital Manager Authorization - Parks

This project includes the demolition of existing facilities, installation of a new prefabrication pit vault restroom building, new paved ADA parking stall, minor grading, and seeding.

Iowa DNR

Morgan Nordyke

515-250-3711 morgan.nordyke@dnr.iowa.gov

6200 Park Ave. Ste 200

Des Moines, IA 50321

Iowa Department of Natural Resources Construction Documents for

Shimek State Forest Lee County, Iowa

Lower Equestrian Campground Pit Latrine Project No. 27-06-56-01

Project Location Map

N

Sheet Index

Cover Sheet Project Overview Quantities & General Information Plan View & Details

Iowa DNR

Bruce Flippin

515-689-8009 bruce.flippin@dnr.iowa.gov

6200 Park Avenue, Ste 200

Des Moines, IA 50321

Engineering Bureau Chief

Authorization to Bid

Date

Date

I hereby certify that this engineering document was prepared by me or under my direct personal supervision and that I am a duly licensed Professional Engineer under the laws of the State of Iowa.

Directory Project Manager

Organization

Contact

Phone

Email

Address

City, State, Zip

District Engineer Organization

Contact

Phone

Email

Address

City, State, Zip

Project Description

Project Number:

27-06-56-01

Bid Date:

mm/dd/yyyy

Iowa Department of Natural Resources Engineering Section - 6200 Park Ave., Suite 200 Des Moines, IA 50321-1270

Lower Equestrian Campground Pit Latrine Shimek State Forest, Lee County

Sheet No:Drawn by: MN

M

Sh ar ed d riv es

\D N

R

LW

B

EN

G Pr oj ec ts \5

6_ Le e\

-0 6-

-0

Sh im ek

C am pg ro un d

Pi t L at rin e\ 5_

De sig n\ A_

CA

D\

C3 D\

-0

6-

-0

Sh im ek C am pg ro un d Pi t L at rin e.

dw g

8/

/2

8:

A

M Pl ot D at e:

Revision Date Cover Sheet

Project Area

AutoCAD SHX Text

MICHAEL D. DUFOE 17753

AutoCAD SHX Text A

AutoCAD SHX Text N

AutoCAD SHX Text I

AutoCAD SHX Text O

AutoCAD SHX Text W

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text P

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text C

AutoCAD SHX Text I

AutoCAD SHX Text L

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text I

AutoCAD SHX Text G

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text L

AutoCAD SHX Text A

0' 500' 1000'

N

Project Number:

27-06-56-01

Bid Date:

mm/dd/yyyy

Iowa Department of Natural Resources Engineering Section - 6200 Park Ave., Suite 200 Des Moines, IA 50321-1270

Lower Equestrian Campground Pit Latrine Shimek State Forest, Lee County

Sheet No:Drawn by: MN

M

Sh ar ed d riv es

\D N

R

LW

B

EN

G Pr oj ec ts \5

6_ Le e\

-0 6-

-0

Sh im ek

C am pg ro un d

Pi t L at rin e\ 5_

De sig n\ A_

CA

D\

C3 D\

-0

6-

-0

Sh im ek C am pg ro un d Pi t L at rin e.

dw g

8/

/2

8:

A

M Pl ot D at e:

Revision Date 2Project Overview

State Highway 2

Lick Creek Rd

Lower Campground

230th St

235th St

Upper Campground

Estimate Reference Information 1.

2.

3.

4.

5.

6.

7.

8.

9.

Mobilization - Payment per SUDAS Specifications, Section 1090.

Removal of Existing Pit Latrines - Shall adequately dispose of all building materials. Coordinate with DNR Park Staff to schedule pumping out vault excrement. Backfilling the holes shall be incidental. Spoils from proposed building site can be used and installed in 6" lifts.

Reinforced 6" PCC - Use Iowa DOT Class C4-Mix. Shall be reinforced by #4 bars, 24" O.C., each way. Maximum 1.8% slope in all directions.

Grading necessary to meet plan elevations shall be incidental.

Expansion joints between paving and building shall be incidental.

Contractor shall submit a joint plan to the District Engineer for review and approval.

Granular Subbase - Meets Iowa DOT Specifications, Section 4121

Pavement Markings, Yellow - High Build Waterborne Paint, Pavement shall be power washed before painting. A minimum of a 7-day waiting period after paving shall be observed. Paint shall be 4" wide. Hatched ADA access areas shall have 2-foot spacing per MUTCD.

15 Minute Parking Sign - Shall be installed in front of the 20' parking space per the DNR sign detail.

Precast Modular Restroom - Shall be a prefabricated modular building, Model: Iowa Wood Duck, as manufactured by HuffCutt Concrete Inc. of Chippewa Falls, Wisconsin, or approved equal. The associated Class 10 excavation, dewatering, subgrade preparation, and complete building installation are incidental to this one line item.

Site Restoration - Site to be reestablished back to original condition including seeding and mulching all disturbed areas with Iowa DOT Urban Seeding Mix.

Parking Bumper - One parking bumper to be installed centered on the parking spot and 2' from the parking sign

Project Number:

27-06-56-01

Bid Date:

mm/dd/yyyy

Iowa Department of Natural Resources Engineering Section - 6200 Park Ave., Suite 200 Des Moines, IA 50321-1270

Lower Equestrian Campground Pit Latrine Shimek State Forest, Lee County

Sheet No:Drawn by: MN

M

Sh ar ed d riv es

\D N

R

LW

B

EN

G Pr oj ec ts \5

6_ Le e\

-0 6-

-0

Sh im ek

C am pg ro un d

Pi t L at rin e\ 5_

De sig n\ A_

CA

D\

C3 D\

-0

6-

-0

Sh im ek C am pg ro un d Pi t L at rin e.

dw g

8/

/2

8:

A

M Pl ot D at e:

Revision Date Quantities & General Information

General Information

1. Verify actual locations and elevations with District Engineer.

2. All work shall conform to and be performed in accordance with all applicable codes and ordinances.

3. The contractor shall visit the site and inspect the project area and thoroughly familiarize themselves with the actual job conditions prior to bidding and the start of work. Failure to visit the project site shall not relieve the contractor from performing the work in accordance to the plans, specification, special provisions and contract.

4. The contractor shall verify, at the site, all dimensions and conditions shown on the plans and shall notify the DNR Engineer of any discrepancies, omissions, and/or conflicts prior to proceeding with the work.

5. It shall be the contractor’s responsibility to provide waste areas or disposal sites for excess material (excavated material or broken concrete) which is not desirable to be incorporated into the work involved on this project. No payment for overhaul will be allowed for material hauled to these sites.

No material shall be placed within the right-of-way, unless specifically stated in the plans or approved by the DNR Engineer.

6. The contractor shall not disturb desirable grass areas and desirable trees outside the construction limits. The contractor will not be permitted to park or service vehicles and equipment or use these areas for storage of materials. Storage, parking and service areas will be subject to the approval of the DNR Engineer.

7. Where utilities and fixtures are shown as Existing on the plans or encountered within the construction area, it shall be the responsibility of the contractor to notify the DNR Engineer of those utilities prior to the beginning of any construction. The contractor shall be afforded access to these facilities for necessary modification of services. Underground facilities, structures and utilities have been plotted from available surveys and records and therefore their locations must be considered approximate only. It is possible there may be others, the existence of which is presently not known or shown. It is the contractor’s responsibility to determine their existence and exact location and to avoid damage thereto. No claims for additional compensation will be allowed to the contractor for any interference or delay caused by such work.

8. The contractor shall shape graded area to maintain surface drainage. All elevations are to finish grade.

9. The contractor is expected to have materials, equipment, and labor available on a daily basis to install and maintain erosion control features on the project. This may involve seeding, silt fence, rock ditch checks, silt basins or silt dikes.

6" Reinforced PCC

6" PCC Parking Lot Not To Scale

6" Granular Subbase

#4 Bar, 24" O.C., Each way

Notes:

1. Minimum Lap Splice Length shall be 12".

2. Granular Subbase - Maximum 6" lifts. Placement, compaction, and final elevation of subbase shall be per SUDAS 2010.

3. Control joints shall be cut to a depth of 1 4 of the slab thickness.

6"

3'

3'

7'

GROUND/PAVING

SURFACE

NOT TO SCALE

1'-6"

1'-6"

USE 6" PIPE BOLLARD

FILLED W/CONCRETE

AND PAINTED TRAFFIC

YELLOW ONLY WHEN

SIGN IS IN PAVED AREA

OR SIDEWALK

3500 P.S.I. P.C.

CONCRETE

(WHEN PIPE

BOLLARD IS NOT

INSTALLED,

FOUNDATION

NOT REQUIRED)

SLOPE TOP OF

CONCRETE

SQUARE POST 2-1/4 IN.

SQUARE ANCHOR BASE

2-1/2 IN. LOCATED AT TOP

OF BOLLARD (IF

EQUIPPED) OR TOP OF

GROUND SURFACE

NOTES

1. 12"x18" 15 MINUTE PARKING SIGN SHALL BE MOUNTED 7' FROM FINISH GRADE TO BOTTOM EDGE OF SIGN FACE. MOUNTING HEIGHT MAY BE REDUCED TO 5' IF PLACED IN A LANDSCAPE AREA IN

WHICH PEDESTRIANS ARE NOT EXPECTED TO USE.

2. BOLLARD MAY BE OMITTED IF INSTALLED IN LANDSCAPE AREAS. WHEN INSTALLED IN LANDSCAPE AREAS, MOUNTING POST SHALL BE DRIVEN A MINIMUM OF 3' BELOW FINISHED GRADE. ALTERNATE

MOUNTING POSTS MUST BE APPROVED BY THE FIELD INSPECTOR PRIOR TO CONSTRUCTION.

3. ALL SIGNAGE SHALL BE ENGINEER GRADE .080 ALUMINUM REFLECTIVE SIGN MEETING THE

REQUIREMENTS OF THE MUTCD AND ADAAG.

15 MIN PARKING DETAIL

MINUTE

PARKING

0' 16' 32'

N

Project Number:

27-06-56-01

Bid Date:

mm/dd/yyyy

Iowa Department of Natural Resources Engineering Section - 6200 Park Ave., Suite 200 Des Moines, IA 50321-1270

Lower Equestrian Campground Pit Latrine Shimek State Forest, Lee County

Sheet No:Drawn by: MN

M

Sh ar ed d riv es

\D N

R

LW

B

EN

G Pr oj ec ts \5

6_ Le e\

-0 6-

-0

Sh im ek

C am pg ro un d

Pi t L at rin e\ 5_

De sig n\ A_

CA

D\

C3 D\

-0

6-

-0

Sh im ek C am pg ro un d Pi t L at rin e.

dw g

8/

/2

8:

A

M Pl ot D at e:

Revision Date Plan View & Details

16'

11'

15'

30' 20'

5'

Remove Existing Latrines

Existing Stable

Existing Stable

12'

Maximize Distance From Trees

Existing Pit Latrines to be removed

Existing mounting block located between the pit latrines to be relocated by contractor in location directed by engineer (incidental)

Parking Bumper

Maximize Distance From Trees

Proposed Double Pit Vault Entrance facing west Elevation set by 1.8% max grade from edge of road

Install ADA Parking Space 53 SY of 6" reinforced PCC on 16 tons of granular subbase Max grade at 1.8% in all directions

Sheets and Views
27-06-56-01 Shimek Campground Pit Latrine-1
27-06-56-01 Shimek Campground Pit Latrine-2
27-06-56-01 Shimek Campground Pit Latrine-3
27-06-56-01 Shimek Campground Pit Latrine-4
2026-08-21T14:25:04-0500
Michael Dufoe

File details come from the government source that posted it. Updated .